1303 - ACI Department Calling Group ✔ Sorts Data Updates CEU Can be Copied Description 124i Available — six ACI software ports (2 3-ACI Modules max.) and four ACI Department Calling Groups. 384i Available — 192 ACI software ports (64 3-ACI Modules max.) and 32 ACI Department Calling Groups. INUse Program 1303 - ACI Department Calling Group to assign ACI software ports (1-192) to Department Groups. The 384i system has 32 ACI Department Groups; the 124i system has four. An ACI software port can only be in one group. ACIs in the same Department Group should also be in the same Tenant Group. In 384i, re- fer to the Order option in Program 0005 for the ACI software port number. In 124i, the ACI software ports are the port into which the ACI is connected and the next two consecutive ports. Also use this program to set the ACI software port’s priority. When a call comes into the ACI Department Group, it connects to the ACI software port in order of their priority. A higher priority port (e.g., 1) receives calls before a lower priority port (e.g., 6). Conditions None Feature Cross Reference Analog Communications Interface (ACI) Telephone Programming Instructions To enter data for Program 1303 (ACI Department Group): 1. Enter the programming mode. 2. 1303 + HOLD ACI No? 3. Enter the number of the ACI software port (1-192 in 384i, 1-6 in 124i) you want to program + HOLD ACG No: 4. For the ACI software port selected, enter the number of that port’s ACI Department Group (1-32 in 384i, 1-4 in 124i). 5. HOLD Order No: 6. For the ACI software port selected, enter that port’s priority (1-192 in 384i, 1-6 in 124i). 7. HOLD ACI No? 8. Repeat from step 3 to select another ACI software port. OR HOLD to begin sort. Sorting... Sort complete! Then HOLD to exit. 1300 - ACI Options 1303 - ACI Department Calling Group 92000SWG08 Issue 1-0 PROGRAMMING 945
— For Your Notes — 1300 - ACI Options 1303 - ACI Department Calling Group 946 PROGRAMMING 92000SWG08 Issue 1-0
1500 - Door Box Options1501 - Door Box Tenant Assignment Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available — eight Door Boxes distributed among the four Tenant Groups. INUse Program 1501 - Door Box Tenant Assignment to assign a Tenant Group (1-4) to each Door Box. The sys- tem can have up to eight Door Boxes (four on each PGDU PCB). Conditions None Feature Cross Reference Door Box Telephone Programming Instructions To enter data for Program 1501 (Door Box Tenant Assignment): 1. Enter the programming mode. 2. 1501 + HOLD Door Phone No? 3. Enter the number of the Door Box (1-8) you want to program + HOLD. Door Phone_n: 4. For the Door Box you select, enter the Tenant Group assignment (1-4). 5. HOLD Door Phone No? 6. Repeat from step 3 to program another Door Box. OR HOLD to exit 1500 - Door Box Options 1501 - Door Box Tenant Assignment 92000SWG08 Issue 1-0 PROGRAMMING 947
1502 - Door Box Ring Assignments Sorts Data Updates CEU ✔ Can be Copied Description 124i Available — 72 extensions and eight Door Boxes. 384i Available — 256 extensions and eight Door Boxes. INUse Program 1502 - Door Box Ring Assignments to assign Door Box ringing to extensions. If enabled (1), an extension rings when a caller presses the associated Door Box’s call button. If disabled (0), the extension does not ring. You make a separate entry for each extension and for each Door Box. A Door Box can ring any number of extensions. Conditions None Feature Cross Reference Door Box Telephone Programming Instructions To enter data for Program 1502 (Door Box Ring Assignments): 1. Enter the programming mode. 2. 1502 + HOLD STA PORT No? 3. Enter the number of the extension port (1-256 in 384i, 1-72 in 124i) you want to program + HOLD Door Phone No? 4. For the extension selected, enter the number of the Door Box (1-8) for which you want to program ringing. 5. HOLD Door Phone_n: 6. Enter 1 to have the Door Box ring the extension; 0 to prevent the Door Box from ringing. 7. HOLD Door Phone No? 8. Repeat from step 4 to program another Door Box. OR HOLD + repeat from step 3 to select another extension port to program. OR HOLD + HOLD to exit. 1500 - Door Box Options 1502 - Door Box Ring Assignments 948 PROGRAMMING 92000SWG08 Issue 1-0
1503 - Door Box Chime Pattern Sorts Data Updates CEU Can be Copied Description 124i Available — eight Door Boxes and one Chime Tone. 384i Available — eight Door Boxes and three Chime Tones. INUse Program 1503 - Door Box Chime Pattern to select the chime pattern for each Door Box. In 384i, there are three distinctive chime patterns. In 124i, there is only one chime pattern. Conditions None Default Setting Feature Cross Reference Door Box Telephone Programming Instructions To enter data for Program 1503 (Door Box Chime Pattern): 1. Enter the programming mode. 2. 1503 + HOLD Door Phone No? 3. Enter the number of the Door Box you want to program (1-8) + HOLD The first Door Box you install in 1; the last is 8. Door Phone_n: 4. For the Door Box selected, assign the chime pattern (1-3 in 384i, 1 in 124i) + HOLD Door Phone No? 5. Repeat from step 3 to program another Door Box. OR HOLD to exit. 1500 - Door Box Options 1503 - Door Box Chime Pattern 92000SWG08 Issue 1-0 PROGRAMMING 949
— For Your Notes — 1500 - Door Box Options 1503 - Door Box Chime Pattern 950 PROGRAMMING 92000SWG08 Issue 1-0
1600 - Paging Options1601 - Internal Paging Groups ✔ Sorts Data Updates CEU ✔ Can be Copied Description 124i Available — 72 extensions and eight Internal Paging Groups; extensions not assigned to a group by default. 384i Available — 32 Internal Paging Groups and 256 extensions; extensions assigned to group 1 by default. INUse Program 1601 - Internal Paging Groups to assign extensions to Internal Paging Groups (i.e., Page Zones). In 384i, each of the four Tenant Groups can have up to 32 Internal Paging Groups. The 124i can have up to eight Internal Paging Groups. An extension can be in only one Internal Paging Group. Conditions None Feature Cross Reference Paging (Internal) Telephone Programming Instructions To enter data for Program 1601 (Internal Paging Groups): 1. Enter the programming mode. 2. 1601 + HOLD STA PORT No? 3. Enter the extension port (1-256 in 384i, 1-72 in 124i) you want to program + HOLD STA PORT_nnn: 4. Assign the extension port selected to an Internal Paging Group (1-32 in 384i, 1-8 in 124i). 5. HOLD STA PORT No? 6. Repeat from step 3 to program another extension port. OR OR HOLD to begin sort. Sorting... Sort complete! Then HOLD to exit. 1600 - Paging Options 1601 - Internal Paging Groups 92000SWG08 Issue 1-0 PROGRAMMING 951
1602 - Internal Paging Group Names Sorts Data Updates CEU Can be Copied Description 124i Available — eight Internal Paging Groups. 384i Available — 32 Internal Paging Groups. INUse Program 1602 - Internal Paging Group Names to assign names to Internal Paging Groups (i.e., Page Zones). The system shows the names you program on the telephone displays. Use the following chart when en- tering and editing text. When using the DSS keys, press the key once for the first character, twice for the second character, etc. For example, to enter a C, press DSS1 three times. Press DND to toggle between upper and lower case letters. Keys for Entering Names Use this key . . . When you want to . . . DSS1 Enter characters A-D. After selecting your entry, press check to have system accept it. DSS2 Enter characters E-H. After selecting your entry, press check to have system accept it. DSS3 Enter characters I-L. After selecting your entry, press check to have system accept it. DSS4 Enter characters M-P. After selecting your entry, press check to have system accept it. DSS5 Enter characters Q-T. After selecting your entry, press check to have system accept it. DSS6 Enter characters U-Z. After selecting your entry, press check to have system accept it. DSS7 Enter a hyphen (-). After selecting your entry, press check to have system accept it. DSS8 Enter a blank space. After selecting your entry, press check to have system accept it. DSS9 Enter extended ASCII characters. Press repeatedly to scroll through the list. After selecting your entry, press check to have system accept it. DSS10 Enter punctuation marks. Press repeatedly to scroll through the list. After selecting your entry, press check to have system accept it. CLEAR Save text entry as part of name after you select it. You need to press CHECK after selecting characters from DSS keys 1-10. You don’t need to press CHECK after dialing a dial pad digit (0-9, # or *). CLEAR Clear the text entry if you want to start over. Dialpad digits 0-9, # and *.Enter numbers, # and * as part of the name. You don’t need to press CHECK after entering these characters. 1600 - Paging Options 1602 - Internal Paging Group Names 952 PROGRAMMING 92000SWG08 Issue 1-0
Conditions None Feature Cross Reference Paging (Internal) Telephone Programming Instructions To enter data for Program 1602 (Internal Paging Group Names): 1. Enter the programming mode. 2. 1602 + HOLD Tenant No? 3. Select the Tenant Group (1-4) you want to program + HOLD IPG No? 4. For the Tenant Group selected, select the Internal Paging Group (1-32 in 384i, 1-8 in 124i) you want to program. 5. HOLD (Previous Name) - The previously programmed name displays. 6. Enter the Internal Paging Group name. Refer to the chart above when programming names. IPG No? 7. Repeat from step four to program a name for another Internal Paging Group. OR HOLD + Repeat from step 3 to select another Tenant Group. OR HOLD + HOLD to exit. 1600 - Paging Options 1602 - Internal Paging Group Names 92000SWG08 Issue 1-0 PROGRAMMING 953
1603 - External Paging Zone Tenant Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available — eight External Paging Zones allocated among four Tenant Groups. INUse Program 1603 - External Paging Zone Tenant to assign a Tenant Group to each External Paging zone. The system has eight External Paging zones that you can assign to one of four Tenant Groups. Each PGDU PCB can have four External Paging outputs (2 PCBs max. per system). When programming, the first zone used (on the first PGDU PCB) is zone 1; the last zone used (on the second PGDU PCB) is zone 8. If the system has Door Boxes, you lose one External Paging zone to each Door Box. Conditions None Feature Cross Reference Paging (External) Telephone Programming Instructions To enter data for Program 1603 (External Paging Zone Tenant): 1. Enter the programming mode. 2. 1603 + HOLD Speaker No? 3. Select the External Paging Zone (1-8) you want to program. The first zone used (on the first PGDU PCB) is zone 1; the last zone used (on the second PGDU PCB) is zone 8. If the system has Door Boxes, you lose one External Paging zone to each Door Box. 4. HOLD SPK_n: 5. Assign the Tenant Group (1-4) to the External Paging Zone selected in step 3. 6. HOLD Speaker No? 7. Repeat from step 3 to select another External Paging Zone. OR HOLD to exit. 1600 - Paging Options 1603 - External Paging Zone Tenant 954 PROGRAMMING 92000SWG08 Issue 1-0