Home > Nitsuko > Communications System > Nitsuko 124i/384i Software Manual

Nitsuko 124i/384i Software Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Nitsuko 124i/384i Software Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 57 Nitsuko manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1195
    							1303 - ACI Department Calling Group
    ✔  Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — six ACI software ports
    (2 3-ACI Modules max.) and four
    ACI Department Calling Groups. 384i Available — 192 ACI software ports
    (64 3-ACI Modules max.) and 32
    ACI Department Calling Groups.
    INUse Program 1303 - ACI Department Calling Group to assign ACI software ports (1-192) to Department
    Groups. The 384i system has 32 ACI Department Groups; the 124i system has four. An ACI software port can
    only be in one group. ACIs in the same Department Group should also be in the same Tenant Group. In 384i, re-
    fer to the Order option in Program 0005 for the ACI software port number.  In 124i, the ACI software ports are
    the port into which the ACI is connected and the next two consecutive ports.
    Also use this program to set the ACI software port’s priority. When a call comes into the ACI Department
    Group, it connects to the ACI software port in order of their priority. A higher priority port (e.g., 1) receives calls
    before a lower priority port (e.g., 6).
    Conditions
    None
    Feature Cross Reference
    Analog Communications Interface (ACI)
    Telephone Programming Instructions
    To enter data for Program 1303 (ACI Department Group):
    1. Enter the programming mode.
    2. 1303 + HOLD
    ACI No?
    3. Enter the number of the ACI software port (1-192 in 384i, 1-6 in 124i) you want to program + HOLD
    ACG No:
    4. For the ACI software port selected, enter the number of that port’s ACI Department Group (1-32 in 384i,
    1-4 in 124i).
    5. HOLD
    Order No:
    6. For the ACI software port selected, enter that port’s priority (1-192 in 384i, 1-6 in 124i).
    7. HOLD
    ACI No?
    8. Repeat from step 3 to select another ACI software port.
    OR
    HOLD to begin sort.
    Sorting...
    Sort complete!
      Then HOLD to exit.
    1300 - ACI Options
    1303 - ACI Department Calling Group
    92000SWG08   Issue 1-0 PROGRAMMING   945 
    						
    							— For Your Notes —
    1300 - ACI Options
    1303 - ACI Department Calling Group
    946   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1500 - Door Box Options1501 - Door Box Tenant Assignment
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available — eight Door Boxes
    distributed among the four Tenant
    Groups.
    INUse Program 1501 - Door Box Tenant Assignment to assign a Tenant Group (1-4) to each Door Box. The sys-
    tem can have up to eight Door Boxes (four on each PGDU PCB).
    Conditions
    None
    Feature Cross Reference
    Door Box
    Telephone Programming Instructions
    To enter data for Program 1501 (Door Box Tenant Assignment):
    1. Enter the programming mode.
    2. 1501 + HOLD
    Door Phone No?
    3. Enter the number of the Door Box (1-8) you want to program + HOLD.
    Door Phone_n:
    4. For the Door Box you select, enter the Tenant Group assignment (1-4).
    5. HOLD
    Door Phone No?
    6. Repeat from step 3 to program another Door Box.
    OR
    HOLD to exit
    1500 - Door Box Options
    1501 - Door Box Tenant Assignment
    92000SWG08   Issue 1-0 PROGRAMMING   947 
    						
    							1502 - Door Box Ring Assignments
     Sorts Data  Updates CEU
    ✔  Can be Copied
    Description
     124i Available — 72 extensions and eight
    Door Boxes. 384i Available — 256 extensions and
    eight Door Boxes.
    INUse Program 1502 - Door Box Ring Assignments to assign Door Box ringing to extensions. If enabled (1), an
    extension rings when a caller presses the associated Door Box’s call button. If disabled (0), the extension does
    not ring. You make a separate entry for each extension and for each Door Box. A Door Box can ring any number
    of extensions.
    Conditions
    None
    Feature Cross Reference
    Door Box
    Telephone Programming Instructions
    To enter data for Program 1502 (Door Box Ring Assignments):
    1. Enter the programming mode.
    2. 1502 + HOLD
    STA PORT No?
    3. Enter the number of the extension port (1-256 in 384i, 1-72 in 124i) you want to program + HOLD
    Door Phone No?
    4. For the extension selected, enter the number of the Door Box (1-8) for which you want to program ringing.
    5. HOLD
    Door Phone_n:
    6. Enter 1 to have the Door Box ring the extension; 0 to prevent the Door Box from ringing.
    7. HOLD
    Door Phone No?
    8. Repeat from step 4 to program another Door Box.
    OR
    HOLD + repeat from step 3 to select another extension port to program.
    OR
    HOLD + HOLD to exit.
    1500 - Door Box Options
    1502 - Door Box Ring Assignments
    948   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1503 - Door Box Chime Pattern
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — eight Door Boxes and
    one Chime Tone. 384i Available — eight Door Boxes and
    three Chime Tones.
    INUse Program 1503 - Door Box Chime Pattern to select the chime pattern for each Door Box. In 384i, there are
    three distinctive chime patterns. In 124i, there is only one chime pattern. 
    Conditions
    None
    Default Setting
    Feature Cross Reference
    Door Box
    Telephone Programming Instructions
    To enter data for Program 1503 (Door Box Chime Pattern):
    1. Enter the programming mode.
    2. 1503 + HOLD
    Door Phone No?
    3. Enter the number of the Door Box you want to program (1-8) + HOLD
    The first Door Box you install in 1; the last is 8.
    Door Phone_n:
    4. For the Door Box selected, assign the chime pattern (1-3 in 384i, 1 in 124i) + HOLD
    Door Phone No?
    5. Repeat from step 3 to program another Door Box.
    OR
    HOLD to exit.
    1500 - Door Box Options
    1503 - Door Box Chime Pattern
    92000SWG08   Issue 1-0 PROGRAMMING   949 
    						
    							— For Your Notes —
    1500 - Door Box Options
    1503 - Door Box Chime Pattern
    950   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1600 - Paging Options1601 - Internal Paging Groups
    ✔ Sorts Data  Updates CEU
    ✔  Can be Copied
    Description
     124i Available — 72 extensions and eight
    Internal Paging Groups; extensions
    not assigned to a group by default. 384i Available — 32 Internal Paging
    Groups and 256 extensions; extensions
    assigned to group 1 by default.
    INUse Program 1601 - Internal Paging Groups to assign extensions to Internal Paging Groups (i.e., Page
    Zones). In 384i, each of the four Tenant Groups can have up to 32 Internal Paging Groups. The 124i can have up
    to eight Internal Paging Groups. An extension can be in only one Internal Paging Group.
    Conditions
    None
    Feature Cross Reference
    Paging (Internal)
    Telephone Programming Instructions
    To enter data for Program 1601 (Internal Paging Groups):
    1. Enter the programming mode.
    2. 1601 + HOLD
    STA PORT No?
    3. Enter the extension port (1-256 in 384i, 1-72 in 124i) you want to program + HOLD
    STA PORT_nnn:
    4. Assign the extension port selected to an Internal Paging Group (1-32 in 384i, 1-8 in 124i).
    5. HOLD
    STA PORT No?
    6. Repeat from step 3 to program another extension port.
    OR
    OR
    HOLD to begin sort.
    Sorting...
    Sort complete!
      Then HOLD to exit.
    1600 - Paging Options
    1601 - Internal Paging Groups
    92000SWG08   Issue 1-0 PROGRAMMING   951 
    						
    							1602 - Internal Paging Group Names
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — eight Internal Paging
    Groups. 384i Available — 32 Internal Paging
    Groups.
    INUse Program 1602 - Internal Paging Group Names to assign names to Internal Paging Groups (i.e., Page
    Zones). The system shows the names you program on the telephone displays. Use the following chart when en-
    tering and editing text. When using the DSS keys, press the key once for the first character, twice for the second
    character, etc. For example, to enter a C, press DSS1 three times. Press DND to toggle between upper and lower
    case letters.
    Keys for Entering Names
    Use this key . . . When you want to . . .
    DSS1 Enter characters A-D. After selecting your entry, press
    check to have system accept it.
    DSS2 Enter characters E-H. After selecting your entry, press
    check to have system accept it.
    DSS3 Enter characters I-L. After selecting your entry, press check
    to have system accept it.
    DSS4 Enter characters M-P. After selecting your entry, press
    check to have system accept it.
    DSS5 Enter characters Q-T. After selecting your entry, press
    check to have system accept it.
    DSS6 Enter characters U-Z. After selecting your entry, press
    check to have system accept it.
    DSS7 Enter a hyphen (-). After selecting your entry, press check
    to have system accept it.
    DSS8 Enter a blank space. After selecting your entry, press check
    to have system accept it.
    DSS9 Enter extended ASCII characters. Press repeatedly to scroll
    through the list. After selecting your entry, press check to
    have system accept it.
    DSS10 Enter punctuation marks. Press repeatedly to scroll through
    the list. After selecting your entry, press check to have
    system accept it.
    CLEAR Save text entry as part of name after you select it. You need
    to press CHECK after selecting characters from DSS keys
    1-10. You don’t need to press CHECK after dialing a dial
    pad digit (0-9, # or *).
    CLEAR
    Clear the text entry if you want to start over.
    Dialpad digits 0-9, #
    and *.Enter numbers, # and * as part of the name. You don’t need
    to press CHECK after entering these characters.
    1600 - Paging Options
    1602 - Internal Paging Group Names
    952   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							Conditions
    None
    Feature Cross Reference
    Paging (Internal)
    Telephone Programming Instructions
    To enter data for Program 1602 (Internal Paging Group Names):
    1. Enter the programming mode.
    2. 1602 + HOLD
    Tenant No?
    3. Select the Tenant Group (1-4) you want to program + HOLD
    IPG No?
    4. For the Tenant Group selected, select the Internal Paging Group (1-32 in 384i, 1-8 in 124i) you want to
    program.
    5. HOLD
    (Previous Name) -
    The previously programmed name displays.
    6. Enter the Internal Paging Group name.
    Refer to the chart above when programming names.
    IPG No?
    7. Repeat from step four to program a name for another Internal Paging Group.
    OR
    HOLD + Repeat from step 3 to select another Tenant Group.
    OR
    HOLD + HOLD to exit.
    1600 - Paging Options
    1602 - Internal Paging Group Names
    92000SWG08   Issue 1-0 PROGRAMMING   953 
    						
    							1603 - External Paging Zone Tenant
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available — eight External Paging
    Zones allocated among four Tenant
    Groups.
    INUse Program 1603 - External Paging Zone Tenant to assign a Tenant Group to each External Paging zone.
    The system has eight External Paging zones that you can assign to one of four Tenant Groups. Each PGDU PCB
    can have four External Paging outputs (2 PCBs max. per system). When programming, the first zone used (on
    the first PGDU PCB) is zone 1; the last zone used (on the second PGDU PCB) is zone 8. If the system has Door
    Boxes, you lose one External Paging zone to each Door Box.
    Conditions
    None
    Feature Cross Reference
    Paging (External)
    Telephone Programming Instructions
    To enter data for Program 1603 (External Paging Zone Tenant):
    1. Enter the programming mode.
    2. 1603 + HOLD
    Speaker No?
    3. Select the External Paging Zone (1-8) you want to program.
    The first zone used (on the first PGDU PCB) is zone 1; the last zone used (on the second PGDU
    PCB) is zone 8. If the system has Door Boxes, you lose one External Paging zone to each Door Box.
    4. HOLD
    SPK_n:
    5. Assign the Tenant Group (1-4) to the External Paging Zone selected in step 3.
    6. HOLD
    Speaker No?
    7. Repeat from step 3 to select another External Paging Zone.
    OR
    HOLD to exit.
    1600 - Paging Options
    1603 - External Paging Zone Tenant
    954   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    All Nitsuko manuals Comments (0)

    Related Manuals for Nitsuko 124i/384i Software Manual