Tie Lines (Items 1-10) Voice Mail (Items 1-10 and 19-32) Telephone Programming Instructions To enter data for Program 0116 (Tone Detection Setup): Items 1-18 1. Enter the programming mode. 2. 0116 + HOLD Item No? 3. Enter the number of the item you want to program (1-18) + HOLD 4. Enter the value for the selected item from the table above + HOLD Item No? 5. Repeat from step 3 to select another item (1-18). OR HOLD to exit. Items 19-32 1. Enter the programming mode. 2. 0116 + HOLD Item No? 3. Enter the number of the item (19-32) you want to program + HOLD Tone Type No? 4. For the item selected, enter the Tone Type (1-3) you want to program + HOLD Tone 1 = Ringback (RBT), Tone 2 = Busy Tone (BT), and Tone 3 = Standard Dial Tone (SDT) 5. Enter the value for the item selected from the table above + HOLD Tone Type No? 6. Repeat from step 4 to select another tone type (1-3). OR HOLD + Repeat from step 3 to select another item (19-32). OR HOLD + HOLD to exit. 0100 - Basic Hardware Setup (Part A) 0116 - Tone Detection Setup 92000SWG08 Issue 1-0 PROGRAMMING 675
0117 - Trunk CODEC Gain Type Settings Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. - Requires Base 2.13, EXCPRU 2.18 or higher.- Requires system software 3.04 or higher. INUse this program to customize the five CODEC gain types for trunks. Each type has a unique CODEC transmit and receive level. Use Program 0901 Item 3 to assign gain types to trunk circuits. Available entries are: 0-31 = 0 to + 15.5 dB in .5 dB steps 32-63 = 0 to -15.5 dB in .5 dB steps Following are the default settings for this option: Type 384i 124i Type 1: Transmit and Receive 0 (0 dB) 0 (0 dB) Type 2: Transmit and Receive 42 (-5 dB) 10 (+5 dB) Type 3: Transmit and Receive 38 (-3 dB) 6 (+3 dB) Type 4: Transmit and Receive 6 (+3 dB) 38 (-3 dB) Type 5: Transmit and Receive 10 (+5 dB) 42 (-5 dB) Conditions None Feature Cross Reference Central Office Calls, Answering Central Office Calls, Placing Direct Inward System Access (DISA) T1 Trunking Tie Lines Telephone Programming Instructions To enter data for Program 0117 (Trunk CODEC Gain Type Settings): 1. Enter the programming mode. 2. 0117 + HOLD Type No? 3. Enter the number of the CODEC gain type you want to customize + HOLD Transmit:n The previously programmed value displays. 4. Enter the desired transmit gain (0-63) + HOLD Receive:nn The previously programmed value displays. 5. Enter the desired receive gain (0-63) + HOLD Type No? 6. Repeat from step 3 to program another CODEC gain type OR HOLD to exit. 0100 - Basic Hardware Setup (Part A) 0117 - Trunk CODEC Gain Type Settings 676 PROGRAMMING 92000SWG08 Issue 1-0
0118 - Extension CODEC Gain Type Setup Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0118 - Extension Codec Gain Type Setup to set the five CODEC gain types for 500/2500 type extensions. Each type has a unique CODEC transmit (from system to phone) and receive (from phone to sys- tem) level (called the gain value). You’ll assign CODEC gain types to extensions in Program 1001. The follow- ing chart shows the relative gain (in dB) for each gain value. Enter this gain value . . . For this gain level . . . 0-31 0 dB to +15.5 dB, increasing in .5 dB steps 32-63 0 dB to -15.5 dB, decreasing in .5 dB steps Following are the default settings for this option: Type Setting Type 1: Transmit and Receive 0 (0 dB) Type 2: Transmit and Receive 42 (-5 dB) Type 3: Transmit and Receive 38 (-3 dB) Type 4: Transmit and Receive 6 (+3 dB) Type 5: Transmit and Receive 10 (+5 dB) Conditions None Feature Cross Reference Single Line Telephones Telephone Programming Instructions To enter data for Program 0118 (Extension CODEC Gain Type Setup): 1. Enter the programming mode. 2. 0118 + HOLD Type No. 3. Enter the CODEC Type No. you want to change (1-5). 4. HOLD Transmit: 5. Enter the CODEC transmit gain value (0-31 or 32-63). 6. HOLD Receive: 7. Enter the CODEC receive gain value (0-31 or 32-63). 8. HOLD 0100 - Basic Hardware Setup (Part A) 0118 - Extension CODEC Gain Type Setup 92000SWG08 Issue 1-0 PROGRAMMING 677
9. Repeat from step 3 to make additional entries OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0118 - Extension CODEC Gain Type Setup 678 PROGRAMMING 92000SWG08 Issue 1-0
0119 - External Page/Door Box CODEC Gain Types Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0119 - External Page/Door Box CODEC Gain Types to set up the five CODEC gain types for External Paging and Door Box ports. Each type has a unique CODEC transmit and receive level (called the gain value). You’ll assign CODEC gain types to External Paging and Door Box ports in Program 0120. The fol- lowing chart shows the relative gain (in dB) for each gain value. Enter this gain value . . . For this gain level . . . 0-31 0 dB to +15.5 dB, increasing in .5 dB steps 32-63 0 dB to -15.5 dB, decreasing in .5 dB steps Following are the default settings for this option: Type Setting Type 1: Transmit and Receive 0 (0 dB) Type 2: Transmit and Receive 42 (-5 dB) Type 3: Transmit and Receive 38 (-3 dB) Type 4: Transmit and Receive 6 (+3 dB) Type 5: Transmit and Receive 10 (+5 dB) Conditions None Feature Cross Reference Door Box Paging (External) Telephone Programming Instructions To enter data for Program 0119 (Page/Door Box CODEC Gain Types): 1. Enter the programming mode. 2. 0119 + HOLD Type No. 3. Enter the CODEC Type No. you want to change (1-5). 4. HOLD Transmit: 5. Enter the CODEC transmit gain value (0-31 or 32-63). 6. HOLD Receive: 7. Enter the CODEC receive gain value (0-31 or 32-63). 0100 - Basic Hardware Setup (Part A) 0119 - External Page/Door Box CODEC Gain Types 92000SWG08 Issue 1-0 PROGRAMMING 679
8. Repeat from step 3 to make additional entries. OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0119 - External Page/Door Box CODEC Gain Types 680 PROGRAMMING 92000SWG08 Issue 1-0
0120 - External Page/Door Box CODEC Gain Setup Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0120 - External Page/Door Box CODEC Gain Setup to assign a CODEC gain type (set in Program 0119) to the External Paging and Door Box ports. Assign a gain number to each Paging/Door Box PCB port. Conditions None Feature Cross Reference Door Box Paging (External) Telephone Programming Instructions To enter data for Program 0120 (External Page and Door Box CODEC Setup): 1. Enter the programming mode. 2. 0120 + HOLD PGDU Port No? 3. Enter the number of the port you want to program (1-8). 4. HOLD Port_nn: - 5. Enter the gain value (1-5 from Program 0119). 6. HOLD 7. Repeat from step 3 to make additional entries. OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0120 - External Page/Door Box CODEC Gain Setup 92000SWG08 Issue 1-0 PROGRAMMING 681
0121 - ISDN Layer 1 Operation Mode Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0121 - ISDN Layer 1 Operation Mode Setup 682 PROGRAMMING 92000SWG08 Issue 1-0
0122 - ISDN Layer 1 Timer Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0122 - ISDN Layer 1 Timer Setup 92000SWG08 Issue 1-0 PROGRAMMING 683
0123 - ISDN Layer 2 Operation Mode Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0123 - ISDN Layer 2 Operation Mode Setup 684 PROGRAMMING 92000SWG08 Issue 1-0