    							Tie Lines (Items 1-10)
    Voice Mail (Items 1-10 and 19-32)
    Telephone Programming Instructions
    To enter data for Program 0116 (Tone Detection Setup):
    Items 1-18
    1. Enter the programming mode.
    2. 0116 + HOLD
    Item No?
    3. Enter the number of the item you want to program (1-18) + HOLD
    4. Enter the value for the selected item from the table above + HOLD
    Item No?
    5. Repeat from step 3 to select another item (1-18).
    OR
    HOLD to exit.
    Items 19-32
    1. Enter the programming mode.
    2. 0116 + HOLD
    Item No?
    3. Enter the number of the item (19-32) you want to program + HOLD
    Tone Type No?
    4. For the item selected, enter the Tone Type (1-3) you want to program + HOLD
    Tone 1 = Ringback (RBT), Tone 2 = Busy Tone (BT), and Tone 3 = Standard Dial Tone (SDT)
    5. Enter the value for the item selected from the table above + HOLD
    Tone Type No?
    6. Repeat from step 4 to select another tone type (1-3).
    OR
    HOLD + Repeat from step 3 to select another item (19-32).
    OR
    HOLD + HOLD to exit.
    0100 - Basic Hardware Setup (Part A)
    0116 - Tone Detection Setup
    92000SWG08  Issue 1-0 PROGRAMMING   675 
    						
    							0117 - Trunk CODEC Gain Type Settings
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available. 384i Available.
    - Requires Base 2.13, EXCPRU 2.18
    or higher.- Requires system software 3.04 or
    higher.
    INUse this program to customize the five CODEC gain types for trunks. Each type has a unique CODEC transmit
    and receive level. Use Program 0901 Item 3 to assign gain types to trunk circuits. Available entries are:
    0-31 = 0 to + 15.5 dB in .5 dB steps
    32-63 = 0 to -15.5 dB in .5 dB steps
    Following are the default settings for this option:
    Type 384i 124i
    Type 1: Transmit and Receive 0 (0 dB) 0 (0 dB)
    Type 2: Transmit and Receive 42 (-5 dB) 10 (+5 dB)
    Type 3: Transmit and Receive 38 (-3 dB) 6 (+3 dB)
    Type 4: Transmit and Receive 6 (+3 dB) 38 (-3 dB)
    Type 5: Transmit and Receive 10 (+5 dB) 42 (-5 dB)
    Conditions
    None
    Feature Cross Reference
    Central Office Calls, Answering
    Central Office Calls, Placing
    Direct Inward System Access (DISA)
    T1 Trunking
    Tie Lines
    Telephone Programming Instructions
    To enter data for Program 0117 (Trunk CODEC Gain Type Settings):
    1. Enter the programming mode.
    2. 0117 + HOLD
    Type No?
    3. Enter the number of the CODEC gain type you want to customize + HOLD
    Transmit:n
    The previously programmed value displays.
    4. Enter the desired transmit gain (0-63) + HOLD
    Receive:nn
    The previously programmed value displays.
    5. Enter the desired receive gain (0-63) + HOLD
    Type No?
    6. Repeat from step 3 to program another CODEC gain type
    OR
    HOLD to exit.
    0100 - Basic Hardware Setup (Part A)
    0117 - Trunk CODEC Gain Type Settings
    676   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							0118 - Extension CODEC Gain Type Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available. 384i Available.
    INUse Program 0118 - Extension Codec Gain Type Setup to set the five CODEC gain types for 500/2500 type
    extensions. Each type has a unique CODEC transmit (from system to phone) and receive (from phone to sys-
    tem) level (called the gain value). You’ll assign CODEC gain types to extensions in Program 1001.  The follow-
    ing chart shows the relative gain (in dB) for each gain value.
    Enter this gain value . . . For this gain level . . .
    0-31 0 dB to +15.5 dB, increasing in .5 dB
    steps
    32-63 0 dB to -15.5 dB, decreasing in .5 dB
    steps
    Following are the default settings for this option:
    Type Setting
    Type 1: Transmit and Receive 0 (0 dB)
    Type 2: Transmit and Receive 42 (-5 dB)
    Type 3: Transmit and Receive 38 (-3 dB)
    Type 4: Transmit and Receive 6 (+3 dB)
    Type 5: Transmit and Receive 10 (+5 dB)
    Conditions
    None
    Feature Cross Reference
    Single Line Telephones
    Telephone Programming Instructions
    To enter data for Program 0118 (Extension CODEC Gain Type Setup):
    1. Enter the programming mode.
    2. 0118 + HOLD
    Type No.
    3. Enter the CODEC Type No. you want to change (1-5).
    4. HOLD
    Transmit:
    5. Enter the CODEC transmit gain value (0-31 or 32-63).
    6. HOLD
    Receive:
    7. Enter the CODEC receive gain value (0-31 or 32-63).
    8. HOLD
    0100 - Basic Hardware Setup (Part A)
    0118 - Extension CODEC Gain Type Setup
    92000SWG08  Issue 1-0 PROGRAMMING   677 
    						
    							9. Repeat from step 3 to make additional entries
    OR
    HOLD to exit
    0100 - Basic Hardware Setup (Part A)
    0118 - Extension CODEC Gain Type Setup
    678   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							0119 - External Page/Door Box CODEC Gain Types
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available. 384i Available.
    INUse Program 0119 - External Page/Door Box CODEC Gain Types to set up the five CODEC gain types for
    External Paging and Door Box ports.  Each type has a unique CODEC transmit and receive level (called the
    gain value). You’ll assign CODEC gain types to External Paging and Door Box ports in Program 0120.  The fol-
    lowing chart shows the relative gain (in dB) for each gain value.
    Enter this gain value . . . For this gain level . . .
    0-31 0 dB to +15.5 dB, increasing in .5 dB
    steps
    32-63 0 dB to -15.5 dB, decreasing in .5 dB
    steps
    Following are the default settings for this option:
    Type Setting
    Type 1: Transmit and Receive 0 (0 dB)
    Type 2: Transmit and Receive 42 (-5 dB)
    Type 3: Transmit and Receive 38 (-3 dB)
    Type 4: Transmit and Receive 6 (+3 dB)
    Type 5: Transmit and Receive 10 (+5 dB)
    Conditions
    None
    Feature Cross Reference
    Door Box
    Paging (External)
    Telephone Programming Instructions
    To enter data for Program 0119 (Page/Door Box CODEC Gain Types):
    1. Enter the programming mode.
    2. 0119 + HOLD
    Type No.
    3. Enter the CODEC Type No. you want to change (1-5).
    4. HOLD
    Transmit:
    5. Enter the CODEC transmit gain value (0-31 or 32-63).
    6. HOLD
    Receive:
    7. Enter the CODEC receive gain value (0-31 or 32-63).
    0100 - Basic Hardware Setup (Part A)
    0119 - External Page/Door Box CODEC Gain Types
    92000SWG08  Issue 1-0 PROGRAMMING   679 
    						
    							8. Repeat from step 3 to make additional entries.
    OR
    HOLD to exit
    0100 - Basic Hardware Setup (Part A)
    0119 - External Page/Door Box CODEC Gain Types
    680   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							0120 - External Page/Door Box CODEC Gain Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available. 384i Available.
    INUse Program 0120 - External Page/Door Box CODEC Gain Setup to assign a CODEC gain type (set in Program
    0119) to the External Paging and Door Box ports. Assign a gain number to each Paging/Door Box PCB port.
    Conditions
    None
    Feature Cross Reference
    Door Box
    Paging (External)
    Telephone Programming Instructions
    To enter data for Program 0120 (External Page and Door Box CODEC Setup):
    1. Enter the programming mode.
    2. 0120 + HOLD
    PGDU Port No?
    3. Enter the number of the port you want to program (1-8).
    4. HOLD
    Port_nn: -
    5. Enter the gain value (1-5 from Program 0119).
    6. HOLD
    7. Repeat from step 3 to make additional entries.
    OR
    HOLD to exit
    0100 - Basic Hardware Setup (Part A)
    0120 - External Page/Door Box CODEC Gain Setup
    92000SWG08  Issue 1-0 PROGRAMMING   681 
    						
    							0121 - ISDN Layer 1 Operation Mode Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available.
    INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual.
    0100 - Basic Hardware Setup (Part A)
    0121 - ISDN Layer 1 Operation Mode Setup
    682   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							0122 - ISDN Layer 1 Timer Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available.
    INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual.
    0100 - Basic Hardware Setup (Part A)
    0122 - ISDN Layer 1 Timer Setup
    92000SWG08  Issue 1-0 PROGRAMMING   683 
    						
    							0123 - ISDN Layer 2 Operation Mode Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available.
    INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual.
    0100 - Basic Hardware Setup (Part A)
    0123 - ISDN Layer 2 Operation Mode Setup
    684   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    All Nitsuko manuals Comments (0)