    							2503 - PC Attendant Console Options
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available — Item 1 (Attendant
    Camp On) only.
    INUse Program 2503 - PC Attendant Console Options to assign various options for the PC Attendant Console.
    The entries you make in this program affect all the system’s consoles. Refer to the table below for the descrip-
    tion of each item, its data entry range and its default value.
    PC Attendant Console Options
    Item Description Range Default
    Item 1Attendant Camp On
    Use this option to enable or disable Attendant
    Camp On for the PC Attendant Consoles.0 (Disabled)
    1 (Enabled)0 (Disabled)
    Conditions
    None
    Feature Cross Reference
    PC Attendant Console
    Telephone Programming Instructions
    To enter data for Program 2503 (PC Attendant Console Options):
    1. Enter the programming mode.
    2. 2503 + HOLD
    Item 1:
    3. Enter 1 to enable Item 1; 0 to disable
    4. HOLD to exit.
    2500 - PC Attendant Options
    2503 - PC Attendant Console Options
    92000SWG08   Issue 1-0 PROGRAMMING   1045 
    						
    							— For Your Notes —
    2500 - PC Attendant Options
    2503 - PC Attendant Console Options
    1046   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							2600 - T1 Options2601 - T1 Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — 52 trunks. 384i Available — 128 trunks.
    INUse Program 2601 - T1 Setup to designate the trunks on the T1/PRI Interface PCB for loop start (0) or ground
    start (1) operation. You can make a different assignment for each trunk on each T1/PRI Interface PCB.
    Conditions
    None
    Feature Cross Reference
    T1 Trunking (with ANI/DNIS Compatibility)
    Telephone Programming Instructions
    To enter data for Program 2601 (T1 Setup):
    1. Enter the programming mode.
    2. 2601 + HOLD
    TRK No?
    3. Enter the number of the T1 Trunk you want to program (1-128 in 384i, 5-52 in 124i) + HOLD
    Type:
    The previously programmed value displays.
    4. Enter 0 to make the selected trunk loop start.
    OR
    Enter 1 to make the selected trunk ground start.
    5. HOLD
    TRK No?
    6. Return to step 3 and select another trunk.
    OR
    HOLD to exit.
    2600 - T1 Options
    2601 - T1 Setup
    92000SWG08   Issue 1-0 PROGRAMMING   1047 
    						
    							2602 - T1 Clock Source
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — three maximum PCBs
    per system. 384i Available — five maximum PCBs
    per system.
    INUse Program 2602 - T1 Clock Source to select the clock source for each T1/PRI Interface PCB. The clock
    source can be internal (1) or external (2). If set for internal, the PCB uses its own clock. If set for external, the
    PCB uses the clock provided by the telco.
    Conditions
    None
    Feature Cross Reference
    T1 Trunking (with ANI/DNIS Compatibility)
    Telephone Programming Instructions
    To enter data for Program 2602 (T1 Clock Source):
    1. Enter the programming mode.
    2. 2602 + HOLD
    (384i) SLOT No?
    (124i) UNIT No?
    3. In 384i, enter the T1 PCB slot number (1-25) + HOLD
    In 124i, enter the PCB number (1-3) + HOLD
    Type:
    The previously programmed value displays.
    4. Enter 1 to select the T1 PCB’s internal clock source.
    OR
    Enter 2 to select the external clock source from the telco.
    5. HOLD
    SLOT No?
    6. Return to step 3 and select another slot.
    OR
    HOLD to exit.
    2600 - T1 Options
    2602 - T1 Clock Source
    1048   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							3000 - Account Codes3001 - Account Code Setup
    Description
     124i Available with Base 4.02 or higher
    and EXCPRU 4.02 or higher. In
    earlier versions, use Program 0407
    instead. 384i Available with system software
    3.07.10 or higher. In earlier versions,
    use Program 0407 instead.
    INUse Program 3001 - Account Code Setup to set various Account Code options for an extension’s Class of Serv-
    ice. Assign Class of Service to extensions in Program 1005 - Class of Service. The 384i has 15 Classes of Serv-
    ice in each of four Tenant Groups. Refer to the following chart for a description of each Account Code option,
    its range and default setting. 
    Account Code Setup
    Item Description Range Default
    1Account Code Mode
    Use this option to select the Account
    Code Mode (0-3).0 (Account Codes disabled)
    1 (Account Codes optional)
    2 (Account Codes required but
    not verified)
    3 (Account Codes required and
    verified)0 (Disabled)
    2Forced Account Code Toll Call
    Setup
    Use this option enable Account Codes
    for all calls or just toll calls.0 (Account Codes for both toll
    and local calls)
    1 (Account Codes just for local
    calls)0 (Account Codes for
    both toll and local calls)
    3Account Codes for Incoming Calls
    Use this option to allow users to enter
    Account Codes for incoming calls. If
    disabled, any codes entered dial out
    on the connected trunk.0 (Account Codes for incoming
    calls disabled)
    1 (Account Codes for incoming
    calls enabled)0 (Account Codes for
    incoming calls
    disabled)
    4Hiding Account Codes
    Use this option to either hide or show
    the Account Codes on a telephone’s
    display.0 (Account Codes displayed)
    1 (Account Codes hidden)0 (Account Codes
    displayed)
    Conditions
    None
    Feature Cross Reference
    Account Codes
    Telephone Programming Instructions
    To enter data for Program 3001 (Account Code Setup:
    1. Enter the programming mode.
    2. 3001 + HOLD
    Tenant No?
    3. Enter the number of the Tenant Group you want to program (1-4) + HOLD
    Class No?
    3000 - Account Codes
    3001 - Account Code Setup
    92000SWG08   Issue 1-0 PROGRAMMING   1049 
    						
    							4. For the Tenant Group selected, enter the number of the Class of Service (1-15) you want to program +
    HOLD
    Item No?
    5. Enter the number of the item you want to program + HOLD
    Item_nnn:n
    The previously programmed value displays.
    6. Enter data (see the chart above) for the item selected + HOLD
    7. Return to step 5 and select another item number.
    OR
    HOLD + Return to step 4 and select another Class of Service
    OR
    HOLD + HOLD to return to step 3 and select another Tenant Group.
    OR
    HOLD three times to exit.
    3000 - Account Codes
    3001 - Account Code Setup
    1050   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							3002 - Verified Account Code Table
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — requires Base 4.02 or
    higher and EXCPRU or higher. 384i Available — requires system
    software 3.07.10 or higher.
    INUse Program 3002 - Verified Account Code Table to enter Account Codes into the Verified Account Code list.
    You can enter up to 1000 codes from 3-16 digits long, using the characters 0-9 or #. Use the FLASH key to enter
    a wild card. For example, the entry FLASH234 means the user can enter 0234-9234.
    Conditions
    None
    Feature Cross Reference
    Account Codes
    Telephone Programming Instructions
    To enter data for Program 3002 (Verified Account Code Table):
    1. Enter the programming mode.
    2. 3002 + HOLD
    Bin No?
    3. Enter the number of the Verified Account Code bin (0-999) you want to program + HOLD
    nnnn-
    The previously programmed Verified Account Code displays.
    4. Enter the Verified Account Code + HOLD
    Verified Account Codes are from 3-16 digits long using the characters 0-9 and #. Press the
    FLASH key to enter a wild card.
    Bin No?
    5. Return to step 3 and select another bin number.
    OR
    HOLD to exit.
    3000 - Account Codes
    3002 - Verified Account Code Table
    92000SWG08   Issue 1-0 PROGRAMMING   1051 
    						
    							– For Your Notes –
    3000 - Account Codes
    3002 - Verified Account Code Table
    1052   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							        
    Using the Default Settings Table
    A few simple rules . . .
    1. If a cell is blank, it uses the entry in the cell to the left. For example, the default Program 0101 Duration
    interval is 10 for all columns.
    2. If an entry had a different value in a prior software level, the historical entry is shown in a row just be-
    low the current entry. Look at Program 0401 Item 2 as an example.
    •In software levels prior to 124i EXCPRU 2.18, the entry was 0.
    •The remainder of the row is shaded in gray to indicate that the change only applies to 124i EXCPRU.
    Program Item/Prompt 124i Base
    3.04384i
    3.07.34124i
    EXCPRU124i PC
    Program384i PC
    Program
     0100
       0101 Duration: 10
    Pause: 10
       0102 Type: 2 N/A
       0103 Type: 3
    Program Item/Prompt 124i Base
    3.04384i
    3.07.34124i
    EXCPRU124i PC
    Program384i PC
    Program
    0400
       0401 Item 1 1
    Item 2 1 0
    < 2.18=0
    Item 3 0
       
         
    92000SWG08   Issue 1-0 PROGRAMMING   1053 
    						
    							   
         
    1054   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    All Nitsuko manuals Comments (0)