Nitsuko 124i/384i Software Manual
Have a look at the manual Nitsuko 124i/384i Software Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 57 Nitsuko manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
9. Repeat from step 3 to make additional entries OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0131 - Unsupervised Conf. CODEC Gain Setup 92000SWG08 Issue 1-0 PROGRAMMING 695
0132 - DID Trunk Timers Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0132 - DID Trunk Timers to set the Direct Inward Dialing (DID) Trunk Timers. The settings you make in this program affect all DID trunks in all Tenant Groups. Make sure the DID Trunk Timers are compatible with you local telco. Refer to the following chart for a description of each timer, its range and default setting. DID Trunk Timers Item Description Range Default Item 1Loop Current/Polarity Detection Time1-255 (8-2040 mS in 8 mS steps)3 (24 mS) Item 2Clear Signal (Open Loop) Detection1-255 (100-2550 mS in 100 mS steps)6 (600 mS) Item 3Release Hold Time1-255 (100-2550 mS in 100 mS steps)30 (3000 mS) Item 4Wink Duration Time1-255 (8-2040 mS in 8 mS steps)25 (200 mS) Item 5Incoming Wink Send Time1-255 (100-2550 mS in 100 mS steps)3 (300 mS) Conditions None Feature Cross Reference Direct Inward Dialing (DID) 0100 - Basic Hardware Setup (Part A) 0132 - DID Trunk Timers 696 PROGRAMMING 92000SWG08 Issue 1-0
Telephone Programming Instructions To enter data for Program 0132 (DID Trunk Timers): 1. Enter the programming mode. 2. 0132 + HOLD Item No? 3. Enter the number of the timer you want to program (1-5) + HOLD (timer): 4. Enter data for the timer selected + HOLD Refer to the chart above for the timer settings. Item No? 5. Return to step 3 to program another timer. OR HOLD to exit. 0100 - Basic Hardware Setup (Part A) 0132 - DID Trunk Timers 92000SWG08 Issue 1-0 PROGRAMMING 697
0133 - Tie Line Timers Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INProgram 0133 - Tie Line Timers sets various timers for Tie Lines. The settings you make in this program af- fect all tie lines in all Tenant Groups. Be sure to set the Tie Line Timers for compatibility with the local telco. Re- fer to the following chart for a description of each timer, its range and default setting. Tie Line Timers Timer Description Range Default Item 1Answer Signal Time1-255 (4-1020 mS in 4 mS steps) 15 (60 mS) Item 2Clear Signal (Open Loop) Detection Time 1-255 (100-25500 mS in 100 mS steps7 (700 mS) Item 3Ringing Signal Detection Minimum Time1-255 (8-2040 mS in 8 mS steps)20 (160 mS) Item 4Ringing Signal Stop Detection Time1-255 (100-25500 mS in 100 mS steps) 7 (700 mS) Item 5Dial Pulse Break Time (10 pps)1-255 (4-1020 mS in 4 mS steps)15 (60 mS) Item 6Dial Pulse Make Time (10 pps)1-255 (4-1020 mS in 4 mS steps)10 (40 mS) Item 7Dial Pulse Interdigit Time (10 pps)1-255 (100-25500 mS in 100 mS steps)8 (800 mS) Item 8Dial Pulse Break Time (20 pps)1-255 (4-1020 mS in 4 mS steps)8 (32mS) Item 9Dial Pulse Make Time (20 pps)1-255 (4-1020 mS in 4 mS steps)4 (16 mS) Item 10Dial Pulse Interdigit Time (20 pps)1-255 (100-25500 mS in 100 mS steps) 5 (500 mS) Item 11Flash Hook Time 11-255 (8-2040 mS in 8 mS steps)25 (200 mS) Item 12Pause Time 1-255 (1-255 seconds)3 (3 seconds) 0100 - Basic Hardware Setup (Part A) 0133 - Tie Line Timers 698 PROGRAMMING 92000SWG08 Issue 1-0
Tie Line Timers Timer Description Range Default Item 13Wink Duration Time1-255 (8-2040 mS in 8 mS steps) 25 (200 mS) Item 14Incoming Wink Send Time1-255 (100-25500 mS in 100mS steps)10 (1000mS) Item 15Wink Receive Maximum Time (Seizure)1-255 (100-25500 mS in 100mS steps) 48 (4800 mS) Item 16Wink Receive Minimum Time (Receive)1-255 (8-2040 mS in 8 mS steps)12 (96 mS) Item 17Wink Receive Maximum Time (Receive)1-255 (8-2040 mS in 8 mS steps)44 (352mS) Item 18Dial Pulse Make Minimum Time (Receive)1-255 (4-1020 mS in 4 mS steps)3 (12 mS) Item 19Dial Pulse Make Maximum Time (Receive)1-255 (4-1020 mS in 4 mS steps)19 (76 mS) Item 20Dial Pulse Break Minimum Time (Receive)1-255 (4-1020 mS in 4 mS steps)8 (32 mS) Item 21Dial Pulse Break Maximum Time (Receive)1-255 (4-1020 mS in 4 mS steps)27 (108 mS) Item 22Pause Time after Wink Receive1-255 (8-2040 mS in 8 mS steps)13 (104 mS) Conditions None Feature Cross Reference Tie Lines Telephone Programming Instructions To enter data for Program 0133 (Tie Line Timers): 1. Enter the programming mode. 2. 0133 + HOLD 3. Enter the number of the timer you want to program (1-22) + HOLD (timer): 4. Enter data for the timer selected + HOLD 0100 - Basic Hardware Setup (Part A) 0133 - Tie Line Timers 92000SWG08 Issue 1-0 PROGRAMMING 699
Refer to the chart above for the timer settings. Item No? 5. Return to step 3 to program another timer. OR HOLD to exit. 0100 - Basic Hardware Setup (Part A) 0133 - Tie Line Timers 700 PROGRAMMING 92000SWG08 Issue 1-0
0135 - Analog Trunk (ATRU PCB) Timers (Part B) Sorts Data ✔ Updates CEU Can be Copied Description 124i Available. System has 52 trunk ports (1-52). 384i Available. System has 128 trunk ports (1-128). INUse Program 0135 - Analog Trunk (ATRU PCB) Timers (Part A) to set critical timing for the Analog Trunk (ATRU) PCB. The system uses the entries you make in this program for all ATRU PCBs. Refer to the following chart for a description of each timer, its range and default setting. For additional ATRU PCB timers, also see 0114 - Analog Trunk (ATRU PCB) Timers (Part A) on page 666. Analog Trunk (ATRU PCB) Timers (Part B) Item (Timer No.)Description Range Default Item 1Caller ID Ring Timer0-15 (0-1.5 secs in 100 mS steps)2 (200 mS) Item 2Caller ID No Signal Timer0-15 (0-750 mS in 50 mS steps)7 (350 mS) Item 3Caller ID Carrier Detect Timer0-15 0-10=500-1000 mS in 50 mS steps) 11=1200 mS 12=1400 mS 13=1600 mS 14=1800 mS 15=3000 mS6 (800 mS) Conditions None Feature Cross Reference Caller ID 0100 - Basic Hardware Setup (Part A) 0135 - Analog Trunk (ATRU PCB) Timers (Part B) 92000SWG08 Issue 1-0 PROGRAMMING 701
Telephone Programming Instructions To enter data for Program 0135 (Analog Trunk Timers [Part B]): 1. Enter the programming mode. 2. 0135 + HOLD Item No? 3. Enter the number of the timer (Item) you want to program + HOLD 4. Enter the desired timer duration + HOLD 5. Repeat from step 3 to make additional entries OR HOLD to exit 0100 - Basic Hardware Setup (Part A) 0135 - Analog Trunk (ATRU PCB) Timers (Part B) 702 PROGRAMMING 92000SWG08 Issue 1-0
0136 - T1 Trunk Timers Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0136 - T1 Trunk Timers to set various timers for T1 Trunks. Refer to the following chart for a description of each timer, its range and default setting. T1 Trunk Timers Timer Description Range Default Item 1Tie Line Answer Signal Time1-255 (4-1020 mS in 4 mS steps) 15 (60 mS) Item 2OPX Trunk Answer Signal Time1-255 (4-1020 mS in 4 mS steps15 (60 mS) Item 3Clear Signal (Open Loop) Detection Time for Loop Start Trunks)1-255 (100-25500 mS in 100 mS steps)6 (600 mS) Item 4Clear Signal (Open Loop) Detection Time for Ground Start Trunks1-255 (100-25500 mS in 100 mS steps)6 (600 mS) Item 5Clear Signal (Open Loop) Detection Time for DID Trunks1-255 (100-25500 mS in 100 mS steps)6 (600 mS) Item 6Clear Signal (Open Loop) Detection Time for Tie Trunks1-255 (100-25500 mS in 100 mS steps)6 (600 mS) Item 7Clear Signal (Open Loop) Detection Time for OPX Trunks1-255 (100-25500 mS in 100 mS steps)6 (600 mS) Item 8Ringing Signal Detection Minimum Time for Loop Start Trunks1-255 (8-2040 mS in 8 mS steps)10 (80 mS) Item 9Ringing Signal Detection Minimum Time for Ground Start Trunks1-255 (8-2040 mS in 8 mS steps)10 (80 mS) Item 10Ringing Signal Detection Minimum Time for DID Trunks1-255 (8-2040 mS in 8 mS steps)7 (56 mS) Item 11Ringing Signal Detection Minimum Time for Tie Trunks1-255 (8-2040 mS in 8 mS steps)7 (56 mS) Item 12Ringing Signal Detection Minimum Time for OPX Trunks1-255 (8-2040 mS in 8 mS steps)10 (80 mS) 0100 - Basic Hardware Setup (Part A) 0136 - T1 Trunk Timers 92000SWG08 Issue 1-0 PROGRAMMING 703
T1 Trunk Timers Timer Description Range Default Item 13Ringing Signal Stop Detection Minimum Time for Loop Start Trunks1-255 (100-25500 mS in 100mS steps)50 (5 S) Item 14Ringing Signal Stop Detection Minimum Time for Ground Start Trunks1-255 (100-25500 mS in 100mS steps)10 (1 S) Item 15Open Loop Time for DID Trunks1-255 (100-25500 mS in 100mS steps) 6 (600 mS) Item 16Close Loop Time for Loop Start Trunks1-255 (4-1020 mS in 4 mS steps)18 (72 mS) Item 17Close Loop Time for DID Trunks1-255 (4-1020 mS in 4 mS steps)18 (72 mS) Item 18Ring Ground Time for Ground Start Trunks1-255 (4-1020 mS in 4 mS steps)13 (52 mS) Item 19Dial Pulse Break Time1-255 (4-1020 mS in 4 mS steps)15 (60 mS) Item 20Dial Pulse Make Time1-255 (4-1020 mS in 4 mS steps)10 (40 mS) Item 21Dial Pulse Interdigit Time1-255 (100-25500 mS in 100mS steps)7 (700 mS) Item 22Pause Time1-255 (8-2040 mS in 8 mS steps)3 (24 mS) Item 23Wink Duration Time for DID Trunks1-255 (8-2040 mS in 8 mS steps)25 (200 mS) Item 24Wink Duration Time for Tie Trunks1-255 (8-2040 mS in 8 mS steps)25 (200 mS) Item 25Incoming Wink Send Time for DID Trunks1-255 (100-25500 mS in 100mS steps)3 (300 mS) Item 26Incoming Wink Send Time for Tie Trunks1-255 (100-25500 mS in 100mS steps)3 (300 mS) 0100 - Basic Hardware Setup (Part A) 0136 - T1 Trunk Timers 704 PROGRAMMING 92000SWG08 Issue 1-0