    of 1195
    							10. Repeat from step 6 to program another timer.
    OR
    HOLD to return to the Class No? prompt.
    0400 - Extension Options (For Tenant Groups)
    0419 - Class of Service Options (Part B)
    92000SWG08  Issue 1-0 PROGRAMMING   775 
    						
    							0420 - E911 Options
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — requires Base and
    EXCPRU 4.02 or higher. 384i Available — requires system
    software 3.07.14 or higher.
    INUse Program 0420 - E911 Options to set various E911 options. Refer to the following chart for a description of
    each option, its range and default setting.
    Tenant Group Options (Part A)
    Item Description Feature Range Default
    Item 1Dial 911 Routing Without Trunk Access
    If enabled (1),an extension user can
    dial 911 without first dialing a trunk
    access code or pressing a line key. If
    disabled (0), an extension user must
    dial a trunk access code (e.g., 9) or
    press a line key before dialing 911. E911
    Compatibility0 = Trunk access
    code required
    1 = Trunk access
    code not required1 (trunk
    access code
    not required)
    Conditions
    None
    Feature Cross Reference
    Refer to the chart above.
    Telephone Programming Instructions
    To enter data for Program 0420 (E911 Options):
    1. Enter the programming mode.
    2. 0420 + HOLD
    Tenant No?
    3. Enter the number of the Tenant Group you want to program (1-4) + HOLD
    Item No?
    4. Enter the number of the item you want to program + HOLD
    Item_nn:
    The previously programmed value displays.
    5. Enter data (see the chart above) for the item selected + HOLD
    Item No?
    6. Repeat from step 4 to select another item.
    OR
    HOLD + Repeat from step 3 to select another Tenant Group.
    OR
    HOLD + HOLD to exit.
    0400 - Extension Options (For Tenant Groups)
    0420 - E911 Options
    776   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							0500 - System Numbering0501 - System Numbering
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available in Base 2.13, EXCPRU
    2.18 or higher. 384i Available. Each Tenant Group can
    have unique system numbering.
    - Setting up single digit Service Codes
    in Program 0501 requires Base 3.04,
    EXCPRU 3.04 or higher.- Setting up single digit Service Codes
    in Program 0501 available in all
    software levels.
    INUse Program 0501 - System Numbering to set the system’s internal (Intercom) numbering plan. The numbering
    plan includes the digits an extension user must dial to access features and other extensions. If the default numbering
    plan does not meet the site requirements, use this program to tailor the system numbering to the site.
    CAUTION
    Improperly programming this option can adversely affect system operation. Make
    sure you thoroughly understand the default numbering plan before proceeding. If you
    must change the standard numbering, use the table beginning on page 779 to keep
    careful and accurate records of your changes.
    Before changing your numbering plan, make a backup copy of your system’s data.
    Use the extra disk shipped with your system to make the backup copy.
    Changing the numbering plan consists of three steps:
    1. Enter the digits you want to change.
    2. Specify the length of the code you select to change.
    3. Assign a function to the code selected.
    Step 1: Enter the digit(s) you want to change
    You can make either single or two digit entries. In the Dialed Number column in the table beginning on
    page 779, the nX rows (e.g., 1X) are for single digit codes. The remaining rows (e.g., 11, 12, etc.) are for
    two digit codes.
    •Entering a single digit affects all the Dialed Number entries beginning with that digit. For exam-
    ple, entering 6 affects all number plan entries beginning with 6. The entries you make in step 2
    and step 3 below affect the entire range of numbers beginning  with  6. (For example, if you enter
    3 in step 2 the entries affected would be 600-699. If you enter 4 in step 2 below, the entries af-
    fected would be 6000-6999.)
    •Entering two digits lets you define codes based on the first two digits a user dials. For example,
    entering 60 allows you to define the function of all codes beginning with 60. In the default pro-
    gram, only * and # use two-digit codes. All the other codes are single digit. If you enter a two
    digit code between 0 and 9, be sure to make separate entries for all the other two digit codes
    within the range as well. This is because in the default program all the two digit codes between 0
    and 9 are undefined.
    •In the PC Program, the nX entry is for single digit codes. For example, 6X is for all codes be-
    tween 600 and 699.
    Step 2: Specify the length of the code you want to change
    After you specify a single or two digit code, you must tell the system how many digits comprise the
    code. This is the Number of Digits Required column in the table beginning on page 779. In the default
    program, all codes from 100-899 are three digits long. Codes beginning with 9 or 0 are one digit long.
    Codes beginning with * and # and 2-4 digits long, depending on the function.
    •If you are programming two digit codes in the PC Program, make sure the nX entry for Number
    of Digits Required is the maximum allowed by any of the two digit codes in the range. This is
    why the default Number of Digits Required entry for #X is four digits long. Even though #1-#9,
    0500 - System Numbering
    0501 - System Numbering
    92000SWG08  Issue 1-0 PROGRAMMING   777 
    						
    							#0 and ## entries require only two digits, #* requires four. If you inadvertently change #* to 2,
    you will no longer be able to enter #*#* to enter the programming mode.
    Step 3: Assign a function to the code selected
    After entering a code and specifying its length, you must assign its function. This is the Dial Type col-
    umn in the table beginning on page 779. The choices are:
    Dial Type Entry Dial Type Description
    0 Not used
    1 Service Code
    2 Extension number
    3-5 Not used
    6 Trunk access
    7 Operator access
    8 Alternate Trunk Access code
    15 (Telephone Program)
    OR
    F (PC Program)Block programming enabled
    (Use only with single digit entries in the Telephone
    Program or X entries in the PC Program.)
    •Changing the Dial Type for a range of codes can have a dramatic affect on how your system operates.
    Assume, for example, the site is a hotel that has room numbers from 100-399. In order to make exten-
    sion numbers correspond to room numbers, you should:
    - Change the Dial Type for the digit 1 from 1 (Service Code) to 2 (extension number).
    - Change the Dial Type for the digit 7 from 3 (not used) to 1 (Service Code).
    - In Program 0502, reassign extension numbers on each floor from 100 to 399).
    - In Program 0514, reassign the Service Codes from the 100 series (e.g., 116) to the 700 series (e.g.,
    716). (Other applications might also require you to change entries in Program 0511.)
    - Check Program 0512 to be sure that the Single Digit Service Code 04 (digit 7) does not affect
    any post dial Service Codes codes in 0514. (Unless you changed codes from their default as-
    signments, this would not be the case.)
    - In Program 0416, disable (0) Item 1. This disables Voice Mail Call Screening. If you left
    screening enabled, Voice Mail ports could call the wrong extensions. For example, a Voice
    Mail port trying to call screen extension 130 would outdial 1130. This would call extension
    113 instead.
    Extension numbers now will correspond to room numbers, and all the Service Codes in the 100
    series will be in the 700 series. 
    •If you are programming two digit codes in the PC Program, make sure the Dial Type entry for nX is F.
    This unlocks the two digit entries. This step is not necessary when using the Telephone Program
    (which automatically enters 15).
    For default settings, refer to the chart beginning on page 779.
    Conditions
    None
    0500 - System Numbering
    0501 - System Numbering
    778   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							System Numbering
    Dial Types:1=Service Code, 2=Extension Number, 6=Trunk Access,
    7=Operator Access, 8=Alternate Trunk Access, 0, 3-5=Not Used
    Dialed
    NumberNumber of Digits RequiredDial Type
    Default NewDefault New
    1X 3 1
    11 0 0
    12 0 0
    13 0 0
    14 0 0
    15 0 0
    16 0 0
    17 0 0
    18 0 0
    19 0 0
    10 0 0
    1* 0 0
    1# 0 0
    2X 3 2
    21 0 0
    22 0 0
    23 0 0
    24 0 0
    25 0 0
    26 0 0
    27 0 0
    28 0 0
    29 0 0
    20 0 0
    2* 0 0
    2# 0 0
    For Your Notes
    0500 - System Numbering
    0501 - System Numbering
    92000SWG08  Issue 1-0 PROGRAMMING   779 
    						
    							System Numbering
    Dial Types:1=Service Code, 2=Extension Number, 6=Trunk Access,
    7=Operator Access, 8=Alternate Trunk Access, 0, 3-5=Not Used
    Dialed
    NumberNumber of Digits RequiredDial Type
    Default NewDefault New
    3X 3 2
    31 0 0
    32 0 0
    33 0 0
    34 0 0
    35 0 0
    36 0 0
    37 0 0
    38 0 0
    39 0 0
    30 0 0
    3* 0 0
    3# 0 0
    4X 3 2
    41 0 0
    42 0 0
    43 0 0
    44 0 0
    45 0 0
    46 0 0
    47 0 0
    48 0 0
    49 0 0
    40 0 0
    4* 0 0
    4# 0 0
    For Your Notes
    0500 - System Numbering
    0501 - System Numbering
    780   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							System Numbering
    Dial Types:1=Service Code, 2=Extension Number, 6=Trunk Access,
    7=Operator Access, 8=Alternate Trunk Access, 0, 3-5=Not Used
    Dialed
    NumberNumber of Digits RequiredDial Type
    Default NewDefault New
    5X 3 2
    51 0 0
    52 0 0
    53 0 0
    54 0 0
    55 0 0
    56 0 0
    57 0 0
    58 0 0
    59 0 0
    50 0 0
    5* 0 0
    5# 0 0
    6X 3 2
    61 0 0
    62 0 0
    63 0 0
    64 0 0
    65 0 0
    66 0 0
    67 0 0
    68 0 0
    69 0 0
    60 0 0
    6* 0 0
    6# 0 0
    For Your Notes
    0500 - System Numbering
    0501 - System Numbering
    92000SWG08  Issue 1-0 PROGRAMMING   781 
    						
    							System Numbering
    Dial Types:1=Service Code, 2=Extension Number, 6=Trunk Access,
    7=Operator Access, 8=Alternate Trunk Access, 0, 3-5=Not Used
    Dialed
    NumberNumber of Digits RequiredDial Type
    Default NewDefault New
    7X 3 2
    71 0 0
    72 0 0
    73 0 0
    74 0 0
    75 0 0
    76 0 0
    77 0 0
    78 0 0
    79 0 0
    70 0 0
    7* 0 0
    7# 0 0
    8X 3 1
    81 0 0
    82 0 0
    83 0 0
    84 0 0
    85 0 0
    86 0 0
    87 0 0
    88 0 0
    89 0 0
    80 0 0
    8* 0 0
    8# 0 0
    For Your Notes
    0500 - System Numbering
    0501 - System Numbering
    782   PROGRAMMING 92000SWG08   Issue 1-0 
    						
    							System Numbering
    Dial Types:1=Service Code, 2=Extension Number, 6=Trunk Access,
    7=Operator Access, 8=Alternate Trunk Access, 0, 3-5=Not Used
    Dialed
    NumberNumber of Digits RequiredDial Type
    Default NewDefault New
    9X 1 6
    91 0 0
    92 0 0
    93 0 0
    94 0 0
    95 0 0
    96 0 0
    97 0 0
    98 0 0
    99 0 0
    90 0 0
    9* 0 0
    9# 0 0
    0X 1 7
    01 0 0
    02 0 0
    03 0 0
    04 0 0
    05 0 0
    06 0 0
    07 0 0
    08 0 0
    09 0 0
    00 0 0
    0* 0 0
    0# 0 0
    For Your Notes
    0500 - System Numbering
    0501 - System Numbering
    92000SWG08  Issue 1-0 PROGRAMMING   783 
    						
    							System Numbering
    Dial Types:1=Service Code, 2=Extension Number, 6=Trunk Access,
    7=Operator Access, 8=Alternate Trunk Access, 0, 3-5=Not Used
    Dialed
    NumberNumber of Digits RequiredDial Type
    Default NewDefault New
    *X 2 1
    *1 0 0
    *2 0 0
    *3 0 0
    *4 0 0
    *5 0 0
    *6 0 0
    *7 0 0
    *8 0 0
    *9 0 0
    *0 0 0
    ** 0 0
    *# 0 0
    #X 4 F
    #1 2 1
    #2 2 1
    #3 2 1
    #4 2 1
    #5 2 1
    #6 2 1
    #7 2 1
    #8 2 1
    #9 2 1
    #0 2 1
    #* 4 1
    ## 2 1
    0500 - System Numbering
    0501 - System Numbering
    784   PROGRAMMING 92000SWG08   Issue 1-0 
    						