    							Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1201 (DCI Setup):
    1. Enter the programming mode.
    2. 1201 + HOLD
    Type No?
    3. Enter the DCI sub-type you want to program (1-10) + HOLD
    You assign DCI software ports to sub-types in Program 1202.
    Item No?
    4. Select the register type you want to program (1 or 2) + HOLD
    1 = DCI S-Registers, 2 = DCI LAPB Registers
    Register No?
    5. Enter the number of the register you want to program + HOLD
    Refer to the charts above for the register numbers.
    The prompts you see depend on the register you select. Refer to the charts above.
    6. Enter data for the register you select + HOLD
    Certain registers (e.g., S-Register 65) require you to enter more than one field of data. You see
    the prompt below when you enter data for a register’s last field.
    Register No?
    7. Repeat from step 5 to program another register.
    OR
    HOLD + Repeat from step 4 to select another register type.
    OR
    HOLD + HOLD to repeat from step 3 and select another DCI sub-type.
    OR
    HOLD three times to exit.
    1200 - DCI Options
    1201 - DCI Setup
    92000SWG08   Issue 1-0 PROGRAMMING   935 
    						
    							1202 - DCI Port Type
     Sorts Data  Updates CEU
    ✔  Can be Copied
    Description
     124i Available — 72 DCI software ports. 384i Available — 288 DCI software ports.
    Additional port types are available in
    system software 3.04 and higher.
    SBFor each DCI software port (1-144 and 145-288 in 384i, 1-72 in 124i), use Program 1202 - DCI Port Type to
    assign the DCI port type (RS-232-C or Centronics) and the DCI sub-type. Available types are:
    •0 (None)
    •1 (DCI connected to RS-232 DTE port)
    •2 (DCI connected to Centronics port)
    •3 (Not used)
    •4 (DCI connected to RS-232 DCE port)
    Each sub-type is a unique DCI configuration, with unique register settings (Program 1201). When program-
    ming, assign DCIs with the same configuration to the same sub-type. In 384i, refer to the Order option in Pro-
    gram 0005 for the DCI software port number. In 124i, the DCI software port number is the same as the
    extension to which it is connected. 
    Conditions
    None
    Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1202 (DCI Port Type):
    1. Enter the programming mode.
    2. 1202 + HOLD
    DCI No?
    3. Enter the DCI software port you want to program.
    In 384i, DCI Module software ports are 1-144. 3-DCI software ports are 145-288.
    In 124i, DCI software ports are 1-72 (the same as the extension port to which the device is
    connected).
    4. HOLD
    DCI Type:
    5. Enter the DCI type for the software port selected in the previous step + HOLD
    0 = None, 1 = DCI connected to RS-232 DTE port, 2 = DCI connected to Centronics port, 3
    (Not used), 4 (DCI connected to RS-232 DCE port).
    Prior to system software 3.04, 0 = None, 1 = RS-232 and 2 = Centronics.
    DCI Sub Type:
    6. Enter the DCI’s subtype (1-10) + HOLD
    DCI No?
    7. Repeat from step 3 to program another DCI software port.
    OR
    HOLD to exit.
    1200 - DCI Options
    1202 - DCI Port Type
    936   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1203 - DCI Tenant Group
    ✔ Sorts Data  Updates CEU
    ✔  Can be Copied
    Description
     124i Not available. 384i Available — 288 DCI software ports
    and four Tenant Groups.
    INUse Program 1203 - DCI Tenant Group to assign a DCI software port (1-144, 145-288) to a Tenant Group (1-
    4). Refer to the Order option in Program 0005 for the DCI software port number.
    Conditions
    None
    Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1203 (DCI Tenant Group):
    1. Enter the programming mode.
    2. 1203 + HOLD
    DCI No?
    3. Enter the DCI software port number you want to program + HOLD
    DCI Module software ports are 1-144. 3-DCI software ports are 145-288.
    DCI_nnn:
    4. For the DCI software port selected, enter the Tenant Group (1-4) + HOLD
    DCI No?
    5. Repeat from step 3 to program another DCI software port.
    OR
    HOLD to begin sort.
    Sorting...
    Sort complete!
      Then HOLD to exit.
    1200 - DCI Options
    1203 - DCI Tenant Group
    92000SWG08   Issue 1-0 PROGRAMMING   937 
    						
    							1204 - DCI Department Group
    ✔  Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — 72 DCI software ports
    and eight DCI Department Groups. 384i Available — 288 DCI software ports
    and 32 DCI Department Groups.
    INUse Program 1204 - DCI Department Group to set up DCI Department Groups. The system allows up to 32 DCI
    Department Groups in 384i and eight in 124i. This program also lets you assign the priority of each DCI software
    port within a DCI Department Group. When calling a DCI Department Group, DCIs with a higher priority number
    (e.g., 1) are connected before DCIs with a lower priority number (e.g., 72). In 384i, refer to the Order option in Pro-
    gram 0005 for the DCI software port number. In 124i, the DCI software port number is the same as the extension
    to which it is connected. 
    Be sure to also assign pilot numbers to the DCI Departments in Program 0507. 
    Conditions
    None
    Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1204 (DCI Department Group):
    1. Enter the programming mode.
    2. 1204 + HOLD
    DCI No?
    3. Enter the DCI software port number you want to program + HOLD
    In 384i, DCI Module software ports are 1-144. 3-DCI software ports are 145-288.
    IN 124i, DCI software ports are 1-72.
    DCG No:
    4. For the DCI software port selected, enter the DCI Department Group number (1-32 in 384i, 1-8 in 124i).
    5. HOLD
    Order No
    6. Enter the DCI software port’s priority within the DCI Department Group (1-288 in 384i, 1-72 in 124i).
    7. HOLD
    DCI No?
    8. Repeat from step 3 to program another DCI software port.
    OR
    HOLD to begin sort.
    Sorting...
    Sort complete!
      Then HOLD to exit.
    1200 - DCI Options
    1204 - DCI Department Group
    938   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1205 - DCI Toll Restriction Class
     Sorts Data  Updates CEU
    ✔  Can be Copied
    Description
     124i Available — eight DCI Toll
    Restriction classes. 384i Available — 15 DCI Toll Restriction
    Classes.
    INUse Program 1205 - DCI Toll Restriction Class to set the Toll Restriction Class (1-15 in 384i, 1-eight in 124i)
    for each DCI software port. The system uses Toll Restriction Class for outgoing (trunk) data calls. Toll Restric-
    tion Class does not affect internal data calls. For each DCI software port, you make one entry for each Night
    Service mode and the Power Failure mode:
    DAY = Day Mode
    NIT = Night Mode
    MID = Midnight Mode
    REST = Rest Mode
    BACKUP = Power Failure Mode
    In 384i, refer to the Order option in Program 0005 for the DCI software port number.
    Conditions
    None
    Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1205 (DCI Toll Restriction Class):
    1. Enter the programming mode.
    2. 1205 + HOLD
    DCI No?
    3. Enter the DCI software port number you want to program + HOLD
    In 384i, DCI Module software ports are 1-144. 3-DCI software ports are 145-288.
    In 124i, DCI software ports are 1-72.
    CLS(DAY)
    4. For the DCI software port selected, enter the Day Mode Toll Restriction Class (1-15 in 384i, 1-8 in 124i).
    5. HOLD
    CLS(NIT)
    6. For the DCI software port selected, enter the Night Mode Toll Restriction Class (1-15 in 384i, 1-8 in 124i).
    7. HOLD
    CLS(MID)
    8. For the DCI software port selected, enter the Midnight Mode Toll Restriction Class (1-15 in 384i, 1-8 in
    124i).
    9. HOLD
    CLS(REST)
    10. For the DCI software port selected, enter the Rest Mode Toll Restriction Class (1-15 in 384i, 1-8 in 124i).
    11. HOLD
    CLS(BACKUP)
    12. For the DCI software port selected, enter the Backup Mode Toll Restriction Class (1-15 in 384i, 1-8 in
    124i).
    1200 - DCI Options
    1205 - DCI Toll Restriction Class
    92000SWG08   Issue 1-0 PROGRAMMING   939 
    						
    							13. HOLD
    DCI No?
    14. Repeat from step 3 to program another DCI software port.
    OR
    HOLD to exit.
    1200 - DCI Options
    1205 - DCI Toll Restriction Class
    940   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1206 - Initialize DCI
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — 72 DCI software ports . 384i Available — 288 DCI software ports
    INAfter changing the register values in Program 1201, use Program 1206 - Initialize DCI  to initialize the DCI
    software port changed. You must initialize a DCI software port before the changes you made in Program 1201
    will take effect. In 384i, refer to the Order option in Program 0005 for the DCI software port number. In 124i,
    the DCI software port number is the same as the extension to which it is connected. 
    Conditions
    None
    Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1206 (Initialize DCI):
    1. Enter the programming mode.
    2. 1206 + HOLD
    DCI No?
    3. Enter the DCI software port number you want to program + HOLD
    In 384i, DCI Module software ports are 1-144. 3-DCI software ports are 145-288.
    In 124i, DCI software ports are 1-72.
    DCI_nnn Initial!
    This indicates that the DCI software port has been successfully initialized.
    4. HOLD
    DCI No?
    5. Repeat from step 3 to program another DCI software port.
    OR
    HOLD to exit.
    1200 - DCI Options
    1206 - Initialize DCI
    92000SWG08   Issue 1-0 PROGRAMMING   941 
    						
    							1207 - DCI Hotline Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — 24 Hotline pairs. 384i Available — 50 Hotline pairs in each
    of four Tenant Groups.
    INUse Program 1207 - DCI Hotline Setup to set up a DCI Hotline (nailed-up connection) between an exten-
    sion with a DCI Module and a destination DCI. When the user at the DCI Hotline originator presses the data
    key, the system automatically calls the programmed destination. In 384i, each Tenant Group has 50 Hotline pairs
    that you can assign. The 124i has 24 Hotline pairs. When assigning Hotline pairs, use the DCI extension num-
    bers set in Program 0503.
    Conditions
    None
    Feature Cross Reference
    Data Communications Interface (DCI)
    Telephone Programming Instructions
    To enter data for Program 1207 (DCI Hotline Setup):
    1. Enter the programming mode.
    2. 1207 + HOLD
    Tenant No?
    3. Enter the number of the Tenant Group (1-4) you want to program + HOLD
    Hotline No?
    4. For the Tenant Group you select, enter the Hotline number (1-50 in 384i, 1-24 in 124i) you want to pro-
    gram.
    5. HOLD
    Origin:
    6. Enter the DCI extension number of the Hotline originator (457-799 in 384i, 373-799 in 124i) + HOLD
    The originator is the extension placing the Hotline call.
    Make sure the extension number you select is part of the Tenant Group you specified in step 3.
    Target:
    7. Enter the DCI extension number of the Hotline target (457-799 in 384i, 373-799 in 124i) + HOLD
    The Hotline target is the DCI extension called when the originator presses their data key.
    Make sure the extension number you select is part of the Tenant Group you specified in step 3.
    Hotline No?
    8. Repeat from step 4 to program another Hotline.
    OR
    HOLD to repeat from step 3 and select another Tenant Group.
    OR
    HOLD + HOLD to exit.
    1200 - DCI Options
    1207 - DCI Hotline Setup
    942   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							1300 - ACI Options1301 - ACI Port Function
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i Available — six ACI software ports
    (2 3-ACI Modules max.). 384i Available — 192 ACI software ports
    (64 3-ACI Modules max.).
    INUse Program 1301 - ACI Port Function to set the function of each software port on an Analog Communica-
    tions Interface. Each ACI software port can have only one function (input, output or none). In 384i, refer to the
    Order option in Program 0005 for the ACI software port number. In 124i, the ACI software ports are the port
    into which the ACI is connected and the next two consecutive ports.
    Conditions
    Feature Cross Reference
    Analog Communications Interface (ACI)
    Telephone Programming Instructions
    To enter data for Program 1301 (ACI Port Function):
    1. Enter the programming mode.
    2. 1301 + HOLD
    ACI No?
    3. Enter the number of the ACI software port (1-192 in 384i, 1-6 in 124i) you want to program + HOLD
    ACI_nnn:
    4. Enter the ACI software port function (0-2).
    0 = No function assigned, 1 = Input (for music source), 2 = Output (for External Paging or
    tape recording)
    5. HOLD
    ACI No?
    6. Repeat from step 3 to enter another ACI software port number.
    OR
    HOLD to exit.
    1300 - ACI Options
    1301 - ACI Port Function
    92000SWG08   Issue 1-0 PROGRAMMING   943 
    						
    							1302 - ACI Tenant Group
    ✔  Sorts Data   Updates CEU   Can be Copied
    Description
     124i Not available. 384i Available — 192 ACI software ports
    (64 3-ACI Modules max.).
    INUse Program 1302 - ACI Tenant Group to assign an ACI software port (1-192) to a Tenant Group (1-4). Refer
    to the Order option in Program 0005 for the ACI software port number.
    Conditions
    None
    Feature Cross Reference
    Analog Communications Interface (ACI)
    Telephone Programming Instructions
    To enter data for Program 1302 (ACI Tenant Group):
    1. Enter the programming mode.
    2. 1302 + HOLD
    ACI No?
    3. Enter the number of the ACI software port (1-192) you want to program + HOLD
    ACI_nnn:
    4. For the ACI software port selected, enter the number of the Tenant Group (1-4)
    5. HOLD
    ACI No?
    6. Repeat from step 3 to program another ACI software port.
    OR
    HOLD to begin sort.
    Sorting...
    Sort complete!
      Then HOLD to exit.
    1300 - ACI Options
    1302 - ACI Tenant Group
    944   PROGRAMMING 92000SWG08  Issue 1-0 
    						