0005 - Extension Circuit Type Sorts Data Updates CEU Can be Copied Description 124i Not available — circuit types auto- ID. This option is in the 124i PC Program for reference only. 384i Available INUse Program 0005 - Extension Circuit Type Setup to set the circuit type for the device at each extension port (1-256). The following table shows the available circuit types: This device . . .Use this circuit type . . . Not set 0 Keyset 1 Keyset with DCI Module 2 500/2500 set 3 3-DCI Module 4 3-ACI Module 5 VAU Module 8 Assign Order 1 to the Main VAU Module Assign Order 2 to the Plug-in Expansion Board 2-OPX Module 9 Conditions None Feature Cross Reference For this feature . . . Use this option for . . . Analog Communications Interface Assigning circuit type 5 to an 3-ACI Module. Data Communications Assigning circuit type 2 to a keyset with a DCI Module and circuit type 4 to a 3-DCI Module. Telephone Programming Instructions To enter data for Program 0005 (Extension Circuit Type): 1. Enter the programming mode. 2. 0005 + HOLD. STA PORT No? 3. Enter the extension port number you want to program and press HOLD. 0000 - Maintenance Options 0005 - Extension Circuit Type 92000SWG08 Issue 1-0 PROGRAMMING 625
Type: 4. Enter the circuit type for the port selected and press HOLD. Order: 5. Refer to the Understanding Port Assignments table below and enter the Order Number. STA PORT No? 6. Enter the extension port number you want to program and press HOLD. OR Press HOLD to exit program. Setting the Installation Order Number Use the following table when assigning the Order Number in step 5 above. Also keep the following in mind: •The system capacity is 384 physical ports •The total of extensions ports, trunk ports, 3-ACI units, 3-DCI units and 2-OPX ports cannot exceed 384. •The system assigns a separate set of software ports to DCIs, 3-DCIs and 3-ACIs. The software port as- signments are for programming only. The ports do not overlap. For example, 3-ACI software port 150 is not the same as 3-DCI software port 150. •Each 2-OPX uses up two physical ports - the one it is plugged into and the next consecutive physical port. All 2-OPX ports must be on the same DSTU PCB. If you use the last port on a DSTU PCB for a 2- OPX, the second 2-OPX port doesn’t work. •Each trunk circuit uses one physical port. Software trunk ports are numbered 1-128. Understanding Port Assignments Device Physical Port Circuit Type Installation Order NumberSoftware Port System Capacity Keyset 1-256 1 Not used 1-256 Same as physical port number256 DCI Module Same as keyset in which DCI is installed21-144 11-144 Used in Series 1200 Programs144 500/2500 Type Single Line17-256 3 Not used Not used 240 3-DCI Module Same as station port into which 3-DCI is plugged41 1 2 through 48145 146 147 148 149 150 286 287 288 Used in Series 1300 Programs48 144 separate DCI ports, with 3 ports on each 3-DCI. The 3-DCI software port numbering begins where DCI software port numbering ends 0000 - Maintenance Options 0005 - Extension Circuit Type 626 PROGRAMMING 92000SWG08 Issue 1-0
Understanding Port Assignments Device Physical Port Circuit Type Installation Order NumberSoftware Port System Capacity 3-ACI Module Same as station port into which 3-ACI is plugged511 2 through 641 2 3 4 5 6 190 191 192 Used in Series 1300 Programs64 192 separate ACI ports, with 3 ports on each 3-ACI VAU Module Same as station port into which VAU is plugged8 Assign Order 1 to the Main VAU Module Assign Order 2 to the Plug-in Expansion Board2-256 1 Main VAU Module and 1 Plug-in Expansion Board 2-OPX 2-256 Each 2-OPX uses up two physical ports: the port into which it is plugged and the next adjacent port9 Not used 2-256 Same as physical port number127 3 Trunk Uses 1 physical portSee Program 0901N/A 1-128 128 1 The Order Number in Program 0005 assigns the Software Port Number. 2 If you plug a keyset into a physical port that was previously assigned as the second port of a 2-OPX, the 2-OPX port will work - the keyset will not. 3 The system must have at least one display keyset for data entry, installed in port 1. 0000 - Maintenance Options 0005 - Extension Circuit Type 92000SWG08 Issue 1-0 PROGRAMMING 627
0006 - Slot Control Sorts Data Updates CEU Can be Copied Description 124i Not available 384i Available from telephone programming only. INUse Program 0006 - Slot Control to close (turn off) or delete (uninstall) circuit boards (slots 1-25). Close lets you block a PCB (just like placing the PCB switch down). Once closed, none of the ports on the PCB can be used for new calls. Existing calls, however, are not torn down. You can cancel the close command by placing the PCB switch to the up position. Delete allows you to completely uninstall the PCB. You might want to do this if you want to remove a PCB and plug it into a different slot - and still retain the port assignments. If a PCB has an active call, you must first Close the PCB before you can delete it. Conditions When you uninstall a PCB, you must remove it from its slot and plug it in again (or into a different slot) before the system will use it again. Feature Cross Reference None Telephone Programming Instructions To enter data for Program 0006 (Slot Control): 1. Enter the programming mode 2. 0006 + HOLD Menu No? 3. To Close a PCB, enter 1+ HOLD. OR To delete a PCB, enter 2 + HOLD. Target Slot? 4. Enter the number of the slot you want to close or delete + HOLD If you are closing a slot, you see: Blocking Start! if the Close is successful. You see Not Used if the slot is vacant. If you are deleting a slot, you see: Delete! if the Delete is successful. You see Not Used if the slot is vacant. 0000 - Maintenance Options 0006 - Slot Control 628 PROGRAMMING 92000SWG08 Issue 1-0
0007 - System Report Port Setup Sorts Data Updates CEU Can be Copied Description 124i The 124i system has an enhanced system report. This program assigns the system report printer and additional report options. Items 2-6 are available from telephone programming only. 384i Assigns only the system report printer. IN384i Use Program 0007 - System Report Port Setup to indicate to which DCI software port (1-288) you have connected the system printer. After selecting the DCI port, you can also use this program to print the system report. To view an abbreviated system report from within the PC program, refer to 0091 - View System Report. To upload the system report from the system to the PC program, use PC program option Main Menu -> Communication -> O/M Command -> 03 Read System Information. 124i Use Program 0007 - System Report Port Setup to: •Assign the DCI software port (1-72) for the enhanced report printer (Item 1) •Print out the entire enhanced report (Item 2) OR Print out selected sections of the enhanced report (Items 3-6). Program 0007 – 124i System Report Port Setup This menu item . . . Lets you . . . With this data . . . 1 1 - Printer Output Port Assign the DCI software port the system uses for the system report printer. For DCI Modules, this is the same number as the DSTU station port. For 3DCI Units, the software port is either the DSTU station port or one of the next two consecutive ports (depending on the installation).DCI software port number + HOLD to assign OR HOLD to cancel without changing 2 - Printout All Alarms Have the printer designated in Item 1 output all the system reports.1 + HOLD for Yes OR HOLD to cancel without changing 3 - Printout Only PCB Board InformationHave the printer designated in Item 1 output just the PCB Board section of the system report (see below).1 + HOLD for Yes OR HOLD to cancel without changing This section shows: – CPRU type BASIC vs. EXPANDED) and software level. – The location (slot number) and software level of each board in each system cabinet. – The location (port number) and type of each telephone installed: KST = Keyset LCD = Two line alphanumeric display HP-LCD = Super Display KST + DCI = Keyset with DCI Unit DSS = DSS Console 0000 - Maintenance Options 0007 - System Report Port Setup 92000SWG08 Issue 1-0 PROGRAMMING 629
PCB Board Information (Item 3) > 03/16/94 00:41 Main Software Version : 1.1F ------------------------------------------------------------------------------ CPRU type is BASIC. Backup battery O.K. - Board install condition - 1 2 3 4 5 6 7 8 Unit 1 +--DSTU-+-------+-------+--ASTA-+-------+--ATRU-+--PGDU-+--DTDU-+ Version 0.05 1.00 0.00 Option DDDD Unit 2 +-------+-------+-------+-------+-------+-------+-------+-------+ Version Option Unit 3 +-------+-------+-------+-------+-------+-------+-------+-------+ Version Option - DSTU Terminals - Unit-Slot Port 1-1 +---1---+---2---+---3---+---4---+---5---+---6---+---7---+---8---+ KST+DCI --- KST --- --- --- --- --- HP-LCD LCD DSS Program 0007 – 124i System Report Port Setup (Cont’d) This menu item . . . Lets you . . . With this data . . . 1 4 - Printout Only Trunk InformationHave the printer designated in Item 1 output just the Trunk section of the system report (see below).1 + HOLD for Yes OR HOLD to cancel without changing This section shows (for each trunk port [1-52]): – The cabinet number, slot and trunk location on PCB (e.g., 1-6-1 is the Main cabinet, slot six, first trunk on the PCB). – Trunk dialing type (e.g., PB for DTMF from Program 0901 Item 1). – Trunk Service Type for each Night Service Mode (from Program 0901 Items 14-17) Trunk Information (Item 4) > 03/16/94 00:41 Software assignment ------------------------------------------------------------------------------ - Trunk port - No. Port Type Day Night Mid Rest 1 1-6-1 PB Normal Normal Normal Normal 2 1-6-2 PB Normal Normal Normal Normal 3 1-6-3 PB Normal Normal Normal Normal 4 1-6-4 PB Normal Normal Normal Normal 5 none PB Normal Normal Normal Normal 6 none PB Normal Normal Normal Normal 0000 - Maintenance Options 0007 - System Report Port Setup 630 PROGRAMMING 92000SWG08 Issue 1-0
Program 0007 – 124i System Report Port Setup (Cont’d) This menu item . . . Lets you . . . With this data . . . 1 5 - Printout Only Station and DCI InformationHave the printer designated in Item 1 output just the Station and DCI section of the system report (see below).1 + HOLD for Yes OR HOLD to cancel without changing For each station port (1-72), this section shows: – The cabinet number, slot and station location on PCB (e.g., 1-1-1 is the Main cabinet, slot one, first station on the PCB). – Extension number and name For each DCI software port (1-72), this section shows: – The cabinet number, slot and station location on PCB (e.g., 1-1-1 is the Main cabinet, slot one, first station on the PCB). – DCI type (e.g., built-in = DCI Module) – DCI extension number Station Information (Item 5) > 03/16/94 00:41 Software assignment ------------------------------------------------------------------------------ - Station port - No. Port Dial Name No. Port Dial Name No. Port Dial Name 1 1-1-1 301 STA 301 25 none 325 STA 325 49 none 349 STA 349 * 2 1-1-2 302 STA 302 26 none 326 STA 326 50 none 350 STA 350 3 1-1-3 303 STA 303 27 none 327 STA 327 51 none 351 STA 351 * 4 1-1-4 304 STA 304 28 none 328 STA 328 52 none 352 STA 352 * 5 1-1-5 305 STA 305 29 none 329 STA 329 53 none 353 STA 353 * 6 1-1-6 306 STA 306 30 none 330 STA 330 54 none 354 STA 354 * 7 1-1-7 307 STA 307 31 none 331 STA 331 55 none 355 STA 355 * 8 1-1-8 308 STA 308 32 none 332 STA 332 56 none 356 STA 356 9 1-4-1 309 STA 309 33 none 333 STA 333 57 none 357 STA 357 10 1-4-2 310 STA 310 34 none 334 STA 334 58 none 358 STA 358 11 1-4-3 311 STA 311 35 none 335 STA 335 59 none 359 STA 359 12 1-4-4 312 STA 312 36 none 336 STA 336 60 none 360 STA 360 13 none 313 STA 313 37 none 337 STA 337 61 none 361 STA 361 14 none 314 STA 314 38 none 338 STA 338 62 none 362 STA 362 15 none 315 STA 315 39 none 339 STA 339 63 none 363 STA 363 16 none 316 STA 316 40 none 340 STA 340 64 none 364 STA 364 17 none 317 STA 317 41 none 341 STA 341 65 none 365 STA 365 18 none 318 STA 318 42 none 342 STA 342 66 none 366 STA 366 19 none 319 STA 319 43 none 343 STA 343 67 none 367 STA 367 20 none 320 STA 320 44 none 344 STA 344 68 none 368 STA 368 21 none 321 STA 321 45 none 345 STA 345 69 none 369 STA 369 22 none 322 STA 322 46 none 346 STA 346 70 none 370 STA 370 23 none 323 STA 323 47 none 347 STA 347 71 none 371 STA 371 24 none 324 STA 324 48 none 348 STA 348 72 none 372 STA 372 0000 - Maintenance Options 0007 - System Report Port Setup 92000SWG08 Issue 1-0 PROGRAMMING 631
- DCI port - No. Port Kind Dial No. Port Kind Dial No. Port Kind Dial 1 1-1-1 built-in 601 25 Not assigned 49 Not assigned 2 Not assigned 26 Not assigned 50 Not assigned 3 Not assigned 27 Not assigned 51 Not assigned 4 Not assigned 28 Not assigned 52 Not assigned 5 Not assigned 29 Not assigned 53 Not assigned 6 Not assigned 30 Not assigned 54 Not assigned 7 Not assigned 31 Not assigned 55 Not assigned 8 Not assigned 32 Not assigned 56 Not assigned 9 Not assigned 33 Not assigned 57 Not assigned 10 Not assigned 34 Not assigned 58 Not assigned 11 Not assigned 35 Not assigned 59 Not assigned 12 Not assigned 36 Not assigned 60 Not assigned 13 Not assigned 37 Not assigned 61 Not assigned 14 Not assigned 38 Not assigned 62 Not assigned 15 Not assigned 39 Not assigned 63 Not assigned 16 Not assigned 40 Not assigned 64 Not assigned 17 Not assigned 41 Not assigned 65 Not assigned 18 Not assigned 42 Not assigned 66 Not assigned 19 Not assigned 43 Not assigned 67 Not assigned 20 Not assigned 44 Not assigned 68 Not assigned 21 Not assigned 45 Not assigned 69 Not assigned 22 Not assigned 46 Not assigned 70 Not assigned 23 Not assigned 47 Not assigned 71 Not assigned 24 Not assigned 48 Not assigned 72 Not assigned Program 0007 – 124i System Report Port Setup (Cont’d) This menu item . . . Lets you . . . With this data . . . 1 6 - Printout Only Other InformationHave the printer designated in Item 1 output just the Other Information section of the system report (see below).1 + HOLD for Yes OR HOLD to cancel without changing For each 3ACI Unit (1-6), this section shows: – The cabinet number, slot and location on station PCB (e.g., 1-1-4 is the Main cabinet, slot one, fourth station on the PCB). – The extension number and type (1=input, 2=output) for each channel on the 3ACI Unit. For each VAU Module, Door Box, External Paging port, alarm sensor and DSS Console, this section shows: – The cabinet number, slot and station location on PCB (e.g., 1-1-5 is the Main cabinet, slot one, fifth station on the PCB). Other Information (Item 6) > 03/16/94 00:41 Software assignment ------------------------------------------------------------------------------ - ACI port - No.Port CH Dial Kind 1 Not assigned No setting 2 Not assigned No setting 3 Not assigned No setting 4 Not assigned No setting 5 Not assigned No setting 6 Not assigned No setting 0000 - Maintenance Options 0007 - System Report Port Setup 632 PROGRAMMING 92000SWG08 Issue 1-0
- VAU port - Unit Slot Port Master Not assigned Slave Not assigned - Door phone port - - Speaker port - - Sensor port - No.Unit Slot Port No.Unit Slot Port No.Unit Slot Port Kind 1 1 7 1 *1 1 7 1 1 1 7 5 Alarm 2 1 7 2 *2 1 7 2 2 1 7 6 Alarm 3 1 7 3 *3 1 7 3 3 1 7 7 Alarm 4 1 7 4 *4 1 7 4 4 1 7 8 Alarm 5 Not assigned 5 Not assigned 5 Not assigned FAX 6 Not assigned 6 Not assigned 6 Not assigned FAX 7 Not assigned 7 Not assigned 7 Not assigned FAX 8 Not assigned 8 Not assigned 8 Not assigned FAX - DSS console port - No. 1 2 3 4 Port 1-1-1 ----- ----- ----- Conditions You cannot place a data call to a DCI port dedicated to the system report, alarm report or SMDR. Feature Cross Reference None 0000 - Maintenance Options 0007 - System Report Port Setup 92000SWG08 Issue 1-0 PROGRAMMING 633
Telephone Programming Instructions To enter data for Program 0007 (System Report Port Setup): (384i Only) 1. Enter the programming mode. 2. 0007 + HOLD Print Port: 3. Enter the system report printer DCI port number (System Report Port ) Print?(Yes:1) 4. Press 1 + HOLD to print the report. OR Press HOLD to skip printing. (124i Only) 1. Enter the programming mode. 2. 0007 + HOLD Menu No? 3. Enter the menu number you want to program (1-6) + HOLD 4.For Item 1 Enter the system report printer DCI port number + HOLD. For Items 2-6 Press 1 + HOLD to activate the option. OR Press HOLD to cancel without implementing the option. 5. When you see Menu NO?, Repeat from step 5 to select another menu number OR HOLD exit. 0000 - Maintenance Options 0007 - System Report Port Setup 634 PROGRAMMING 92000SWG08 Issue 1-0