    							0005 - Extension Circuit Type
     Sorts Data Updates CEU Can be Copied
    Description
     124i Not available — circuit types auto-
    ID. This option is in the 124i PC
    Program for reference only. 384i Available
    INUse Program 0005 - Extension Circuit Type Setup to set the circuit type for the device at each extension port
    (1-256). The following table shows the available circuit types:
    This device . . .Use this circuit type . . .
    Not set 0
    Keyset 1
    Keyset with DCI Module 2
    500/2500 set 3
    3-DCI Module 4
    3-ACI Module 5
    VAU Module 8
    Assign Order 1 to the Main
    VAU Module
    Assign Order 2 to the Plug-in
    Expansion Board
    2-OPX Module 9
    Conditions
    None
    Feature Cross Reference
    For this feature . . .
    Use this option for . . .
    Analog Communications Interface Assigning circuit type 5 to an 3-ACI Module.
    Data Communications Assigning circuit type 2 to a keyset with a DCI
    Module and circuit type 4 to a 3-DCI Module.
    Telephone Programming Instructions
    To enter data for Program 0005 (Extension Circuit Type):
    1. Enter the programming mode.
    2. 0005 + HOLD.
    STA PORT No?
    3. Enter the extension port number you want to program and press HOLD.
    0000 - Maintenance Options
    0005 - Extension Circuit Type
    92000SWG08  Issue 1-0 PROGRAMMING   625 
    						
    							Type:
    4. Enter the circuit type for the port selected and press HOLD.
    Order:
    5. Refer to the Understanding Port Assignments table below and enter the Order Number.
    STA PORT No?
    6. Enter the extension port number you want to program and press HOLD.
    OR
    Press HOLD to exit program.
    Setting the Installation Order Number
    Use the following table when assigning the Order Number in step 5 above. Also keep the following in mind:
    •The system capacity is 384 physical ports
    •The total of extensions ports, trunk ports, 3-ACI units, 3-DCI units and 2-OPX ports cannot exceed
    384.
    •The system assigns a separate set of software ports to DCIs, 3-DCIs and 3-ACIs. The software port as-
    signments are for programming only. The ports do not overlap. For example, 3-ACI software port 150 is
    not the same as 3-DCI software port 150. 
    •Each 2-OPX uses up two physical ports - the one it is plugged into and the next consecutive physical
    port. All 2-OPX ports must be on the same DSTU PCB. If you use the last port on a DSTU PCB for a 2-
    OPX, the second 2-OPX port doesn’t work. 
    •Each trunk circuit uses one physical port. Software trunk ports are numbered 1-128.
    Understanding Port Assignments
    Device Physical Port Circuit Type Installation 
    Order NumberSoftware Port System Capacity
    Keyset 1-256 1 Not used 1-256
    Same as physical
    port number256
    DCI Module Same as keyset
    in which DCI is
    installed21-144
    11-144
    Used in Series
    1200 Programs144
    500/2500 Type
    Single Line17-256 3 Not used Not used 240
    3-DCI Module Same as station
    port into which
    3-DCI is plugged41
    1
    2
    through
    48145
    146
    147
    148
    149
    150
    286
    287
    288
    Used in Series
    1300 Programs48
    144 separate DCI
    ports, with 3
    ports on each
    3-DCI. The
    3-DCI software
    port numbering
    begins where
    DCI software
    port numbering
    ends
    0000 - Maintenance Options
    0005 - Extension Circuit Type
    626   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							Understanding Port Assignments
    Device Physical Port Circuit Type Installation 
    Order NumberSoftware Port System Capacity
    3-ACI Module Same as station
    port into which
    3-ACI is plugged511
    2
    through
    641
    2
    3
    4
    5
    6
    190
    191
    192
    Used in Series
    1300 Programs64
    192 separate ACI
    ports, with 3
    ports on each
    3-ACI
    VAU Module Same as station
    port into which
    VAU is plugged8 Assign Order 1
    to the Main VAU
    Module
    Assign Order 2
    to the Plug-in
    Expansion Board2-256 1 Main VAU
    Module and
    1 Plug-in
    Expansion Board
    2-OPX 2-256
    Each 2-OPX
    uses up two
    physical ports:
    the port into
    which it is
    plugged and the
    next adjacent port9 Not used 2-256
    Same as physical
    port number127
    3
    Trunk Uses 1 physical
    portSee Program
    0901N/A 1-128 128
    1  The Order Number in Program 0005 assigns the Software Port Number.
    2  If you plug a keyset into a physical port that was previously assigned as the second port of
     a 2-OPX, the 2-OPX port will work - the keyset will not.
    3   The system must have at least one display keyset for data entry, installed in port 1.
    0000 - Maintenance Options
    0005 - Extension Circuit Type
    92000SWG08  Issue 1-0 PROGRAMMING   627 
    						
    							0006 - Slot Control
     Sorts Data Updates CEU Can be Copied
    Description
     124i Not available 384i Available from telephone
    programming only.
    INUse Program 0006 - Slot Control to close (turn off) or delete (uninstall) circuit boards (slots 1-25). 
    Close lets you block a PCB (just like placing the PCB switch down). Once closed, none of the ports on the PCB
    can be used for new calls. Existing calls, however, are not torn down. You can cancel the close command by
    placing the PCB switch to the up position.
    Delete allows you to completely uninstall the PCB. You might want to do this if you want to remove a PCB and
    plug it into a different slot - and still retain the port assignments. If a PCB has an active call, you must first
    Close the PCB before you can delete it.
    Conditions
    When you uninstall a PCB, you must remove it from its slot and plug it in again (or into a different slot) before
    the system will use it again.
    Feature Cross Reference
    None
    Telephone Programming Instructions
    To enter data for Program 0006 (Slot Control):
    1. Enter the programming mode
    2. 0006 + HOLD
    Menu No?
    3. To Close a PCB, enter 1+ HOLD.
    OR
    To delete a PCB, enter 2 + HOLD.
    Target Slot?
    4. Enter the number of the slot you want to close or delete + HOLD
    If you are closing a slot, you see:
    Blocking Start!
    if the Close is successful. You see Not Used if the slot is vacant.
    If you are deleting a slot, you see:
    Delete!
    if the Delete is successful. You see Not Used if the slot is vacant.
    0000 - Maintenance Options
    0006 - Slot Control
    628   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							0007 - System Report Port Setup
      Sorts Data   Updates CEU   Can be Copied
    Description
     124i The 124i system has an enhanced
    system report. This program assigns
    the system report printer and
    additional report options. Items 2-6
    are available from telephone
    programming only. 384i Assigns only the system report
    printer.
    IN384i
    Use Program 0007 - System Report Port Setup to indicate to which DCI software port (1-288) you have connected
    the system printer. After selecting the DCI port, you can also use this program to print the system report. To view an
    abbreviated system report from within the PC program, refer to 0091 - View System Report. To upload the system
    report from the system to the PC program, use PC program option Main Menu -> Communication -> O/M
    Command -> 03 Read System Information.
    124i
    Use Program 0007 - System Report Port Setup to:
    •Assign the DCI software port (1-72) for the enhanced report printer (Item 1)
    •Print out the entire enhanced report (Item 2)
    OR
    Print out selected sections of the enhanced report (Items 3-6). 
    Program 0007 – 124i System Report Port Setup
    This menu item . . . Lets you . . .  With this data . . .
    1
    1 - Printer Output Port Assign the DCI software port the
    system uses for the system report
    printer. For DCI Modules, this is the
    same number as the DSTU station
    port. For 3DCI Units, the software
    port is either the DSTU station port or
    one of the next two consecutive ports
    (depending on the installation).DCI software port number + HOLD
    to assign
    OR
    HOLD to cancel without changing
    2 - Printout All Alarms Have the printer designated in Item 1
    output all the system reports.1 + HOLD for Yes
    OR
    HOLD to cancel without changing
    3 - Printout Only PCB
    Board InformationHave the printer designated in Item 1
    output just the PCB Board section of
    the system report (see below).1 + HOLD for Yes
    OR
    HOLD to cancel without changing
    This section shows:
    – CPRU type BASIC vs. EXPANDED) and software level.
    – The location (slot number) and software level of each board in each system cabinet.
    – The location (port number) and type of each telephone installed:
    KST = Keyset
      LCD = Two line alphanumeric display
      HP-LCD = Super Display
    KST + DCI = Keyset with DCI Unit
    DSS = DSS Console
    0000 - Maintenance Options
    0007 - System Report Port Setup
    92000SWG08  Issue 1-0 PROGRAMMING   629 
    						
    							PCB Board Information (Item 3)
    >     03/16/94 00:41
    Main Software Version : 1.1F
    ------------------------------------------------------------------------------
    CPRU type is BASIC. Backup battery O.K.
    - Board install condition -
                1       2       3       4       5       6       7       8
    Unit 1  +--DSTU-+-------+-------+--ASTA-+-------+--ATRU-+--PGDU-+--DTDU-+
    Version                            0.05            1.00            0.00
    Option                                                     DDDD
    Unit 2  +-------+-------+-------+-------+-------+-------+-------+-------+
    Version
    Option
    Unit 3  +-------+-------+-------+-------+-------+-------+-------+-------+
    Version
    Option
    - DSTU Terminals -
    Unit-Slot                          Port
       1-1  +---1---+---2---+---3---+---4---+---5---+---6---+---7---+---8---+
             KST+DCI   ---     KST     ---     ---     ---     ---     ---
              HP-LCD           LCD
               DSS
    Program 0007 – 124i System Report Port Setup (Cont’d)
    This menu item . . . Lets you . . .  With this data . . .
    1
    4 - Printout Only Trunk
    InformationHave the printer designated in Item 1
    output just the Trunk section of the
    system report (see below).1 + HOLD for Yes
    OR
    HOLD to cancel without changing
    This section shows (for each trunk port [1-52]):
    – The cabinet number, slot and trunk location on PCB  (e.g., 1-6-1 is the Main
      cabinet, slot six, first trunk on the PCB).
    – Trunk dialing type (e.g., PB for DTMF from Program 0901 Item 1).
    – Trunk Service Type for each Night Service Mode (from Program 0901
     Items 14-17)
    Trunk Information (Item 4)
    >     03/16/94 00:41
    Software assignment
    ------------------------------------------------------------------------------
    - Trunk port -
     No. Port Type   Day    Night  Mid    Rest
      1 1-6-1 PB     Normal Normal Normal Normal
      2 1-6-2 PB     Normal Normal Normal Normal
      3 1-6-3 PB     Normal Normal Normal Normal
      4 1-6-4 PB     Normal Normal Normal Normal
      5  none PB     Normal Normal Normal Normal
      6  none PB     Normal Normal Normal Normal
    0000 - Maintenance Options
    0007 - System Report Port Setup
    630   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							Program 0007 – 124i System Report Port Setup (Cont’d)
    This menu item . . . Lets you . . .  With this data . . .
    1
    5 - Printout Only
    Station and DCI
    InformationHave the printer designated in Item 1
    output just the Station and DCI section
    of the system report (see below).1 + HOLD for Yes
    OR
    HOLD to cancel without changing
    For each station port (1-72), this section shows:
    – The cabinet number, slot and station location on PCB  (e.g., 1-1-1 is the Main
      cabinet, slot one, first station on the PCB).
    – Extension number and name
    For each DCI software port (1-72), this section shows:
    – The cabinet number, slot and station location on PCB  (e.g., 1-1-1 is the Main
      cabinet, slot one, first station on the PCB).
    – DCI type (e.g., built-in = DCI Module)
    – DCI extension number
    Station Information (Item 5)
    >     03/16/94 00:41
    Software assignment
    ------------------------------------------------------------------------------
    - Station port -
     No. Port Dial Name        No. Port Dial Name        No. Port Dial Name
      1 1-1-1 301  STA 301     25  none 325  STA 325     49  none 349  STA 349
    * 2 1-1-2 302  STA 302     26  none 326  STA 326     50  none 350  STA 350
      3 1-1-3 303  STA 303     27  none 327  STA 327     51  none 351  STA 351
    * 4 1-1-4 304  STA 304     28  none 328  STA 328     52  none 352  STA 352
    * 5 1-1-5 305  STA 305     29  none 329  STA 329     53  none 353  STA 353
    * 6 1-1-6 306  STA 306     30  none 330  STA 330     54  none 354  STA 354
    * 7 1-1-7 307  STA 307     31  none 331  STA 331     55  none 355  STA 355
    * 8 1-1-8 308  STA 308     32  none 332  STA 332     56  none 356  STA 356
      9 1-4-1 309  STA 309     33  none 333  STA 333     57  none 357  STA 357
     10 1-4-2 310  STA 310     34  none 334  STA 334     58  none 358  STA 358
     11 1-4-3 311  STA 311     35  none 335  STA 335     59  none 359  STA 359
     12 1-4-4 312  STA 312     36  none 336  STA 336     60  none 360  STA 360
     13  none 313  STA 313     37  none 337  STA 337     61  none 361  STA 361
     14  none 314  STA 314     38  none 338  STA 338     62  none 362  STA 362
     15  none 315  STA 315     39  none 339  STA 339     63  none 363  STA 363
     16  none 316  STA 316     40  none 340  STA 340     64  none 364  STA 364
     17  none 317  STA 317     41  none 341  STA 341     65  none 365  STA 365
     18  none 318  STA 318     42  none 342  STA 342     66  none 366  STA 366
     19  none 319  STA 319     43  none 343  STA 343     67  none 367  STA 367
     20  none 320  STA 320     44  none 344  STA 344     68  none 368  STA 368
     21  none 321  STA 321     45  none 345  STA 345     69  none 369  STA 369
     22  none 322  STA 322     46  none 346  STA 346     70  none 370  STA 370
     23  none 323  STA 323     47  none 347  STA 347     71  none 371  STA 371
     24  none 324  STA 324     48  none 348  STA 348     72  none 372  STA 372  
    0000 - Maintenance Options
    0007 - System Report Port Setup
    92000SWG08  Issue 1-0 PROGRAMMING   631 
    						
    							- DCI port -
     No. Port Kind     Dial    No. Port Kind     Dial    No. Port Kind     Dial
      1 1-1-1 built-in 601     25 Not assigned           49 Not assigned
      2 Not assigned           26 Not assigned           50 Not assigned
      3 Not assigned           27 Not assigned           51 Not assigned
      4 Not assigned           28 Not assigned           52 Not assigned
      5 Not assigned           29 Not assigned           53 Not assigned
      6 Not assigned           30 Not assigned           54 Not assigned
      7 Not assigned           31 Not assigned           55 Not assigned
      8 Not assigned           32 Not assigned           56 Not assigned
      9 Not assigned           33 Not assigned           57 Not assigned
     10 Not assigned           34 Not assigned           58 Not assigned
     11 Not assigned           35 Not assigned           59 Not assigned
     12 Not assigned           36 Not assigned           60 Not assigned
     13 Not assigned           37 Not assigned           61 Not assigned
     14 Not assigned           38 Not assigned           62 Not assigned
     15 Not assigned           39 Not assigned           63 Not assigned
     16 Not assigned           40 Not assigned           64 Not assigned
     17 Not assigned           41 Not assigned           65 Not assigned
     18 Not assigned           42 Not assigned           66 Not assigned
     19 Not assigned           43 Not assigned           67 Not assigned
     20 Not assigned           44 Not assigned           68 Not assigned
     21 Not assigned           45 Not assigned           69 Not assigned
     22 Not assigned           46 Not assigned           70 Not assigned
     23 Not assigned           47 Not assigned           71 Not assigned
     24 Not assigned           48 Not assigned           72 Not assigned       
    Program 0007 – 124i System Report Port Setup (Cont’d)
    This menu item . . . Lets you . . .  With this data . . .
    1
    6 - Printout Only Other
    InformationHave the printer designated in Item 1
    output just the Other Information section
    of the system report (see below).1 + HOLD for Yes
    OR
    HOLD to cancel without changing
    For each 3ACI Unit (1-6), this section shows:
    – The cabinet number, slot and location on station PCB  (e.g., 1-1-4 is the Main
      cabinet, slot one, fourth station on the PCB).
    – The extension number and type (1=input, 2=output) for each channel on the
     3ACI Unit.
    For each VAU Module, Door Box, External Paging port, alarm sensor and DSS
    Console, this section shows:
    – The cabinet number, slot and station location on PCB  (e.g., 1-1-5 is the Main
      cabinet, slot one, fifth station on the PCB).
    Other Information (Item 6)
    >     03/16/94 00:41
    Software assignment
    ------------------------------------------------------------------------------
    - ACI port -
    No.Port  CH  Dial Kind
     1 Not assigned   No setting
     2 Not assigned   No setting
     3 Not assigned   No setting
     4 Not assigned   No setting
     5 Not assigned   No setting
     6 Not assigned   No setting
    0000 - Maintenance Options
    0007 - System Report Port Setup
    632   PROGRAMMING 92000SWG08  Issue 1-0 
    						
    							- VAU port -
           Unit Slot Port
    Master   Not assigned
    Slave    Not assigned
    - Door phone port -    - Speaker port -       - Sensor port -
    No.Unit Slot Port      No.Unit Slot Port      No.Unit Slot Port Kind
     1    1    7    1      *1    1    7    1       1    1    7    5  Alarm
     2    1    7    2      *2    1    7    2       2    1    7    6  Alarm
     3    1    7    3      *3    1    7    3       3    1    7    7  Alarm
     4    1    7    4      *4    1    7    4       4    1    7    8  Alarm
     5  Not assigned        5  Not assigned        5  Not assigned   FAX
     6  Not assigned        6  Not assigned        6  Not assigned   FAX
     7  Not assigned        7  Not assigned        7  Not assigned   FAX
     8  Not assigned        8  Not assigned        8  Not assigned   FAX
    - DSS console port -
    No.      1       2       3       4
    Port   1-1-1   -----   -----   -----
    Conditions
    You cannot place a data call to a DCI port dedicated to the system report, alarm report or SMDR.
    Feature Cross Reference
    None
    0000 - Maintenance Options
    0007 - System Report Port Setup
    92000SWG08  Issue 1-0 PROGRAMMING   633 
    						
    							Telephone Programming Instructions
    To enter data for Program 0007 (System Report Port Setup):
    (384i Only)
    1. Enter the programming mode.
    2. 0007 + HOLD
    Print Port:
    3. Enter the system report printer DCI port number (System Report Port )
    Print?(Yes:1)
    4. Press 1 + HOLD to print the report.
    OR
    Press HOLD to skip printing.
    (124i Only)
    1. Enter the programming mode.
    2. 0007 + HOLD
    Menu No?
    3. Enter the menu number you want to program (1-6) + HOLD
    4.For Item 1
    Enter the system report printer DCI port number + HOLD.
    For Items 2-6
    Press 1 + HOLD to activate the option.
    OR
    Press HOLD to cancel without implementing the option.
    5. When you see Menu NO?,
    Repeat from step 5 to select another menu number
    OR
    HOLD exit.
    0000 - Maintenance Options
    0007 - System Report Port Setup
    634   PROGRAMMING 92000SWG08  Issue 1-0 
    						