0124 - ISDN Layer 2 Timer Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0124 - ISDN Layer 2 Timer Setup 92000SWG08 Issue 1-0 PROGRAMMING 685
0125 - ISDN Layer 3 Operation Mode Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0125 - ISDN Layer 3 Operation Mode Setup 686 PROGRAMMING 92000SWG08 Issue 1-0
0126 - ISDN Layer 3 Timer Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0126 - ISDN Layer 3 Timer Setup 92000SWG08 Issue 1-0 PROGRAMMING 687
0127 - ITSU Operation Mode Setup Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INRefer to the system PRI (P/N 92000PRI**) or BRI (P/N 92000BRI**) Manual. 0100 - Basic Hardware Setup (Part A) 0127 - ITSU Operation Mode Setup 688 PROGRAMMING 92000SWG08 Issue 1-0
0128 - Analog Station (ASTU PCB) Sidetone Level Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INUse Program 0128 - Analog Station (ASTU PCB) Sidetone Level to set the sidetone level for single line tele- phones connected to ASTU PCBs. In Program 0128 Item 1, you can choose among the four preset sidetone lev- els or up to eight additional levels calibrated to specific telephones. Use Program 0128 Item 2 to calibrate levels for individual phones. 0128 Item 1 Entry Description 0 Highest preset sidetone level 1 Upper mid range preset sidetone level 2 Lower mid range preset sidetone level 3 Lowest mid range preset sidetone level 4-7 Not used (Same level as entry 0) 8-15 Eight additional levels calibrated to certain telephones Conditions None Feature Cross Reference Single Line Telephones Telephone Programming Instructions To assign a sidetone level in Program 0128 Item 1: To create calibrated sidetone levels, turn to the procedure for Item 2 that follows. 1. Enter the programming mode. 2. 0128 + HOLD STA PORT No? 3. Enter the number of ASTU single line station port you want to program + HOLD Item No? 4. 1 + HOLD DSP Type: 5. Enter the desired sidetone level (03, 8-15). The preset sidetone levels are 0-3. The calibrated sidetone levels are 8-15. 6. HOLD Item No? 7. Return to step 4 to assign another sidetone level OR HOLD + Return to step 2 to select another station port OR HOLD + HOLD to exit 0100 - Basic Hardware Setup (Part A) 0128 - Analog Station (ASTU PCB) Sidetone Level 92000SWG08 Issue 1-0 PROGRAMMING 689
To calibrate the sidetone for a specific single line extension in Program 0128 Item 2: 1. Enter the programming mode. 2. 0128 + HOLD STA PORT No? 3. Enter the number of the ASTU single line station port you want to program +HOLD Item No? 4. 2 + HOLD ADF DSP Type 5. Lift the handset on the single line telephone that you want to automatically calibrate. 6. Remove the handset modular line cord. If the handset doesn’t have a modular line cord, disassemble the handset earpiece and remove the wires connected to the receiver element. 7. Enter the number that the system will use to store your calibrated sidetone level (8-15). The number you select will store the calibrated levels that this procedure generates. You can as- sign this number to extensions in the procedure for Item 1. 8. HOLD Testing. . . DSP ADF Complete If you see Error, hand up the handset and repeat from step 5. You must be listening to dial tone at the single line set when the test begins. 9. HOLD to repeat from step 4 OR HOLD + HOLD to repeat from step 3 OR HOLD three times to exit 0100 - Basic Hardware Setup (Part A) 0128 - Analog Station (ASTU PCB) Sidetone Level 690 PROGRAMMING 92000SWG08 Issue 1-0
0129 - Analog Trunk (ATRU PCB) Sidetone Setting Sorts Data Updates CEU Can be Copied Description 124i Not available. 384i Available. INUse Program 0129 - Analog Trunk (ATRU PCB) Sidetone Setting to set the sidetone level for analog trunks con- nected to ATRU PCB ports. In Program 0129, you can choose among the four preset sidetone levels or up to eight ad- ditional levels calibrated to specific trunks. Use Program 0129 Item 2 to calibrate levels for individual trunks. 0129 Item 1 Entry Description Loss 0 Highest preset sidetone level 0 dB 1 Upper mid range preset sidetone level 3 dB 2 Lower mid range preset sidetone level 5 dB 3 Lowest mid range preset sidetone level 7 dB 4-7 Not used (Same level as entry 0) 8-15 Eight additional levels calibrated to certain trunks Conditions None Feature Cross Reference Central Office Calls, Placing Central Office Calls, Answering Telephone Programming Instructions To assign a sidetone level in Program 0129 Item 1: To create calibrated sidetone levels, turn to the procedure for Item 2 that follows. 1. Enter the programming mode. 2. 0129 + HOLD TRK No? 3. Enter the number of ATRU trunk port you want to program + HOLD Item No? 4. 1 + HOLD DSP Type: 5. Enter the desired sidetone level (0-3, 8-15). The preset sidetone levels are 0-3. The calibrated sidetone levels are 8-15. 6. HOLD Item No? 7. Return to step 4 to assign another sidetone level OR HOLD + Return to step 2 to select another station port OR HOLD + HOLD to exit 0100 - Basic Hardware Setup (Part A) 0129 - Analog Trunk (ATRU PCB) Sidetone Setting 92000SWG08 Issue 1-0 PROGRAMMING 691
To calibrate the sidetone for a specific trunk in Program 0129 Item 2: 1. Enter the programming mode. 2. 0129 + HOLD TRK No? 3. Enter the number of the ATRU trunk port you want to program + HOLD Item No? 4. 2 + HOLD ADF DSP Type 5. At a different telephone, use Handsfree (i.e., press SPK) to place or answer a call on the trunk you want to automatically calibrate. 6. Press the MIC key to enable Microphone Mute. The microphone must be muted before going to the next step. For an accurate calibration, the trunk should be on a call and not listening to dial tone. 7. Enter the number that the system will use to store your calibrated sidetone level (8-15). The number you select will store the calibrated levels that this procedure generates. You can as- sign this number to trunks in the procedure for Item 1. 8. HOLD Testing. . . DSP ADF Complete If you see Error, hand up the handset and repeat from step 5. You must be listening to dial tone at the single line set when the test begins. 9. HOLD to repeat from step 4 OR HOLD + HOLD to repeat from step 3 OR HOLD three times to exit 0100 - Basic Hardware Setup (Part A) 0129 - Analog Trunk (ATRU PCB) Sidetone Setting 692 PROGRAMMING 92000SWG08 Issue 1-0
0130 - Date Format for SMDR and System Reports Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0130 - Date Format for SMDR and System Reports to set the date format that appears on the SMDR printout and various system reports. The options are: 0 (U.S.A. format - month/date/year) 1 (Japanese format - year/month/date) 2 (European format - date/month/year) Conditions None Feature Cross Reference Station Message Detail Recording Time and Date Telephone Programming Instructions To enter data for Program 0130 (Date Format for SMDR and System Reports): 1. Enter the programming mode. 2. 0130 + HOLD Format: 3. Enter the desired date format (0=U.S.A., 1 = Japanese and 2 = European) 4. HOLD 0100 - Basic Hardware Setup (Part A) 0130 - Date Format for SMDR and System Reports 92000SWG08 Issue 1-0 PROGRAMMING 693
0131 - Unsupervised Conf. CODEC Gain Setup Sorts Data Updates CEU Can be Copied Description 124i Available. 384i Available. INUse Program 0131 - Unsupervised Conference CODEC Gain Setup to set up the five CODEC gain types for trunk circuits in an Unsupervised Conference. Each type has a unique CODEC transmit and receive level (called the gain value). You assign CODEC gain types to trunks for Unsupervised Conference in Program 0901, Item 23. The following chart shows the relative gain (in dB) for each gain value. Enter this gain value . . . For this gain level . . . 0-31 0 dB to +15.5 dB, increasing in .5 dB steps 32-63 0 dB to -15.5 dB, decreasing in .5 dB steps Following are the default settings for this option: Type Setting Type 1: Transmit and Receive 0 (0 dB) Type 2: Transmit and Receive 42 (-5 dB) Type 3: Transmit and Receive 38 (-3 dB) Type 4: Transmit and Receive 6 (+3 dB) Type 5: Transmit and Receive 10 (+5 dB) Conditions First condition Default Setting Feature Cross Reference Tandem Trunking (Unsupervised Conference) Telephone Programming Instructions To enter data for Program 0131 (Unsupervised Conference Call CODEC Gain Type Settings): 1. Enter the programming mode. 2. 0131 + HOLD Type No. 3. Enter the CODEC Type No. you want to change (1-5). 4. HOLD Transmit: 5. Enter the CODEC transmit gain value (0-31 or 32-63). 6. HOLD Receive: 7. Enter the CODEC receive gain value (0-31 or 32-63). 8. HOLD 0100 - Basic Hardware Setup (Part A) 0131 - Unsupervised Conf. CODEC Gain Setup 694 PROGRAMMING 92000SWG08 Issue 1-0