Samsung Confidential Exynos 5250_UM 4 Pad Control 4-97 4.4.1.139 EXT_INT7CON Base Address: 0x1140_0000 Address = Base Address + 0x0718, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31:16] –=Reserved=0x0000= RSVD=[15]=–=Reserved=0x0= EXT_INT7= _CON[3]=[14:12]=RW= Setting the signaling method=of EXT_INT7[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT7= _CON[2]=[10:8]=RW= Setting the signaling method=of EXT_INT7[2]= 0x0 = Sets Low level= 0x1 = Sets=High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[7]=–=Reserved=0x0= EXT_INT7= _CON[1]=[6:4]=RW= Setting the signaling method=of EXT_INT7[1]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[3]=–=Reserved=0x0= EXT_INT7= _CON[0]=[2:0]=RW= Setting the signaling method=of EXT_INT7[0]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= = =
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-98 4.4.1.140 EXT_INT8CON Base Address: 0x1140_0000 Address = Base Address + 0x071C, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31:28] –=Reserved=0x0= RSVD=[27]=–=Reserved=0x0= EXT_INT8= _CON[6]=[26:24]=RW= Setting the signaling method=of EXT_INT8[6]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[23]=–=Reserved=0x0= EXT_INT8= _CON[5]=[22:20]=RW= Setting the signaling method=of EXT_INT8[5]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[19]=–=Reserved=0x0= EXT_INT8= _CON[4]=[18:16]=RW= Setting the signaling method=of EXT_INT8[4]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 ==Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[15]=–=Reserved=0x0= EXT_INT8= _CON[3]=[14:12]=RW= Setting the signaling method=of EXT_INT8[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT8= _CON[2]=[10:8]=RW= Setting the signaling method=of EXT_INT8[2]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[7]=–=Reserved=0x0=
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-99 Name Bit Type Description Reset Value EXT_INT8 _CON[1] [6:4] RW Setting the signaling method of EXT_INT8[1] 0x0 = Sets Low level 0x1 = Sets High level 0x2 = Triggers Falling edge 0x3 = Triggers Rising edge 0x4 = Triggers Both edge 0x5 to 0x7 = Reserved 0x0 RSVD [3] – Reserved 0x0 EXT_INT8 _CON[0] [2:0] RW Setting the signaling method of EXT_INT8[0] 0x0 = Sets Low level 0x1 = Sets High level 0x2 = Triggers Falling edge 0x3 = Triggers Rising edge 0x4 = Triggers Both edge 0x5 to 0x7 = Reserved 0x0
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-100 4.4.1.141 EXT_INT9CON Base Address: 0x1140_0000 Address = Base Address + 0x0720, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31:16] –=Reserved=0x0000= RSVD=[15]=–=Reserved=0x0= EXT_INT9= _CON[3]=[14:12]=RW= Setting the signaling method=of EXT_INT9[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT9= _CON[2]=[10:8]=RW= Setting the signaling method=of EXT_INT9[2]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[7]=–=Reserved=0x0= EXT_INT9= _CON[1]=[6:4]=RW= Setting the signaling method of EXT_INT9[1]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[3]=–=Reserved=0x0= EXT_INT9= _CON[0]=[2:0]=RW= Setting the signaling method of EXT_INT9[0]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= = =
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-101 4.4.1.142 EXT_INT10CON Base Address: 0x1140_0000 Address = Base Address + 0x0724, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31:28] –=Reserved=0x0= RSVD=[27]=–=Reserved=0x0= EXT_INT10= _CON[6]=[26:24]=RW= Setting the signaling method=of EXT_INT10[6]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[23]=–=Reserved=0x0= EXT_INT10= _CON[5]=[22:20]=RW= Setting the signaling method=of EXT_INT10[5]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[19]=–=Reserved=0x0= EXT_INT10= _CON[4]=[18:16]=RW= Setting the signaling method=of EXT_INT10[4]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[15]=–=Reserved=0x0= EXT_INT10= _CON[3]=[14:12]=RW= Setting the signaling method of EXT_INT10[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT10= _CON[2]=[10:8]=RW= Setting the signaling method of EXT_INT10[2]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[7]=–=Reserved=0x0=
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-102 Name Bit Type Description Reset Value EXT_INT10 _CON[1] [6:4] RW Setting the signaling method of EXT_INT10[1] 0x0 = Sets Low level 0x1 = Sets High level 0x2 = Triggers Falling edge 0x3 = Triggers Rising edge 0x4 = Triggers Both edge 0x5 to 0x7 = Reserved 0x0 RSVD [3] – Reserved 0x0 EXT_INT10 _CON[0] [2:0] RW Setting the signaling method of EXT_INT10[0] 0x0 = Sets Low level 0x1 = Sets High level 0x2 = Triggers Falling edge 0x3 = Triggers Rising edge 0x4 = Triggers Both edge 0x5 to 0x7 = Reserved 0x0
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-103 4.4.1.143 EXT_INT11CON Base Address: 0x1140_0000 Address = Base Address + 0x0728, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31:28] –=Reserved=0x0= RSVD=[27]=–=Reserved=0x0= EXT_INT11= _CON[6]=[26:24]=RW= Setting the signaling method=of EXT_INT11[6]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[23]=–=Reserved=0x0= EXT_INT11= _CON[5]=[22:20]=RW= Setting the signaling method=of EXT_INT11[5]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[19]=–=Reserved=0x0= EXT_INT11= _CON[4]=[18:16]=RW= Setting the signaling method of EXT_INT11[4]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[15]=–=Reserved=0x0= EXT_INT11= _CON[3]=[14:12]=RW= Setting the signaling method=of EXT_INT11[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT11= _CON[2]=[10:8]=RW= Setting the signaling method of EXT_INT11[2]= 0x0 = Sets=Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[7]=–=Reserved=0x0=
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-104 Name Bit Type Description Reset Value EXT_INT11 _CON[1] [6:4] RW Setting the signaling method of EXT_INT11[1] 0x0 = Sets Low level 0x1 = Sets High level 0x2 = Triggers Falling edge 0x3 = Triggers Rising edge 0x4 = Triggers Both edge 0x5 to 0x7 = Reserved 0x0 RSVD [3] – Reserved 0x0 EXT_INT11 _CON[0] [2:0] RW Setting the signaling method of EXT_INT11[0] 0x0 = Sets Low level 0x1 = Sets High level 0x2 = Triggers Falling edge 0x3 = Triggers Rising edge 0x4 = Triggers Both edge 0x5 to 0x7 = Reserved 0x0
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-105 4.4.1.144 EXT_INT12CON Base Address: 0x1140_0000 Address = Base Address + 0x072C, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31:16] –=Reserved=0x0000= RSVD=[15]=–=Reserved=0x0= EXT_INT12= _CON[3]=[14:12]=RW= Setting the signaling method=of EXT_INT12[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT12= _CON[2]=[10:8]=RW= Setting the signaling method=of EXT_INT12[2]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[7]=–=Reserved=0x0= EXT_INT12= _CON[1]=[6:4]=RW= Setting the signaling method=of EXT_INT12[1]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[3]=–=Reserved=0x0= EXT_INT12= _CON[0]=[2:0]=RW= Setting the signaling method=of EXT_INT12[0]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= = =
Samsung Confidential Exynos 5250_UM 4 Pad Control 4-106 4.4.1.145 EXT_INT13CON Base Address: 0x1140_0000 Address = Base Address + 0x0730, Reset Value = 0x0000_0000 Name Bit Type Description Reset Value RSVD [31] –=Reserved=0x0= EXT_INT13= _CON[7]=[30:28]=RW= Setting the signaling method=of EXT_INT13[7]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[27]=–=Reserved=0x0= EXT_INT13= _CON[6]=[26:24]=RW= Setting the signaling method=of EXT_INT13[6]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[23]=–=Reserved=0x0= EXT_INT13= _CON[5]=[22:20]=RW= Setting the signaling method=of EXT_INT13[5]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[19]=–=Reserved=0x0= EXT_INT13= _CON[4]=[18:16]=RW= Setting the signaling method=of EXT_INT13[4]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSsa=[15]=–=Reserved=0x0= EXT_INT13= _CON[3]=[14:12]=RW= Setting the signaling method=of EXT_INT13[3]= 0x0 = Sets Low level= 0x1 = Sets High level= 0x2 = Triggers Falling edge = 0x3 = Triggers Rising edge== 0x4 = Triggers Both edge== 0x5 to 0x7 = Reserved= 0x0= RSVD=[11]=–=Reserved=0x0= EXT_INT13=[10:8]=RW=Setting the signaling method=of EXT_INT13[2]=0x0=