Home > Samsung > Processor > Samsung Exynos 5 User Manual

Samsung Exynos 5 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Samsung Exynos 5 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1705 Samsung manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 881
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-97  
    4.4.1.139 EXT_INT7CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x0718, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:16] –=Reserved=0x0000=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT7=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT7[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT7=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT7[2]=
    0x0 = Sets Low level=
    0x1 = Sets=High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT7=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT7[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT7=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT7[0]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-98  
    4.4.1.140 EXT_INT8CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x071C, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:28] –=Reserved=0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT8=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT8[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT8=
    _CON[5]=[22:20]=RW=
    Setting the signaling method=of EXT_INT8[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT8=
    _CON[4]=[18:16]=RW=
    Setting the signaling method=of EXT_INT8[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 ==Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT8=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT8[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT8=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT8[2]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0= 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-99  
    Name Bit Type Description Reset Value 
    EXT_INT8 
    _CON[1] [6:4] RW 
    Setting the signaling method of EXT_INT8[1] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
    RSVD [3] – Reserved 0x0 
    EXT_INT8 
    _CON[0] [2:0] RW 
    Setting the signaling method of EXT_INT8[0] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
     
      
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-100  
    4.4.1.141 EXT_INT9CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x0720, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:16] –=Reserved=0x0000=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT9=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT9[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT9=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT9[2]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT9=
    _CON[1]=[6:4]=RW=
    Setting the signaling method of EXT_INT9[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT9=
    _CON[0]=[2:0]=RW=
    Setting the signaling method of EXT_INT9[0]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-101  
    4.4.1.142 EXT_INT10CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x0724, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:28] –=Reserved=0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT10=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT10[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT10=
    _CON[5]=[22:20]=RW=
    Setting the signaling method=of EXT_INT10[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT10=
    _CON[4]=[18:16]=RW=
    Setting the signaling method=of EXT_INT10[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT10=
    _CON[3]=[14:12]=RW=
    Setting the signaling method of EXT_INT10[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT10=
    _CON[2]=[10:8]=RW=
    Setting the signaling method of EXT_INT10[2]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0= 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-102  
    Name Bit Type Description Reset Value 
    EXT_INT10 
    _CON[1] [6:4] RW 
    Setting the signaling method of EXT_INT10[1] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
    RSVD [3] – Reserved 0x0 
    EXT_INT10 
    _CON[0] [2:0] RW 
    Setting the signaling method of EXT_INT10[0] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
     
      
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-103  
    4.4.1.143 EXT_INT11CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x0728, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:28] –=Reserved=0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT11=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT11[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT11=
    _CON[5]=[22:20]=RW=
    Setting the signaling method=of EXT_INT11[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT11=
    _CON[4]=[18:16]=RW=
    Setting the signaling method of EXT_INT11[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT11=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT11[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT11=
    _CON[2]=[10:8]=RW=
    Setting the signaling method of EXT_INT11[2]=
    0x0 = Sets=Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0= 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-104  
    Name Bit Type Description Reset Value 
    EXT_INT11 
    _CON[1] [6:4] RW 
    Setting the signaling method of EXT_INT11[1] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
    RSVD [3] – Reserved 0x0 
    EXT_INT11 
    _CON[0] [2:0] RW 
    Setting the signaling method of EXT_INT11[0] 
    0x0 = Sets Low level 
    0x1 = Sets High level 
    0x2 = Triggers Falling edge  
    0x3 = Triggers Rising edge  
    0x4 = Triggers Both edge  
    0x5 to 0x7 = Reserved 
    0x0 
     
      
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-105  
    4.4.1.144 EXT_INT12CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x072C, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31:16] –=Reserved=0x0000=
    RSVD=[15]=–=Reserved=0x0=
    EXT_INT12=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT12[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT12=
    _CON[2]=[10:8]=RW=
    Setting the signaling method=of EXT_INT12[2]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[7]=–=Reserved=0x0=
    EXT_INT12=
    _CON[1]=[6:4]=RW=
    Setting the signaling method=of EXT_INT12[1]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[3]=–=Reserved=0x0=
    EXT_INT12=
    _CON[0]=[2:0]=RW=
    Setting the signaling method=of EXT_INT12[0]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    =
    = 
    						
    							Samsung Confidential  
    Exynos 5250_UM 4 Pad Control 
     4-106  
    4.4.1.145 EXT_INT13CON 
     Base Address: 0x1140_0000 
     Address = Base Address + 0x0730, Reset Value = 0x0000_0000 
    Name Bit Type Description Reset Value 
    RSVD [31] –=Reserved=0x0=
    EXT_INT13=
    _CON[7]=[30:28]=RW=
    Setting the signaling method=of EXT_INT13[7]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[27]=–=Reserved=0x0=
    EXT_INT13=
    _CON[6]=[26:24]=RW=
    Setting the signaling method=of EXT_INT13[6]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[23]=–=Reserved=0x0=
    EXT_INT13=
    _CON[5]=[22:20]=RW=
    Setting the signaling method=of EXT_INT13[5]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[19]=–=Reserved=0x0=
    EXT_INT13=
    _CON[4]=[18:16]=RW=
    Setting the signaling method=of EXT_INT13[4]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSsa=[15]=–=Reserved=0x0=
    EXT_INT13=
    _CON[3]=[14:12]=RW=
    Setting the signaling method=of EXT_INT13[3]=
    0x0 = Sets Low level=
    0x1 = Sets High level=
    0x2 = Triggers Falling edge =
    0x3 = Triggers Rising edge==
    0x4 = Triggers Both edge==
    0x5 to 0x7 = Reserved=
    0x0=
    RSVD=[11]=–=Reserved=0x0=
    EXT_INT13=[10:8]=RW=Setting the signaling method=of EXT_INT13[2]=0x0= 
    						
    All Samsung manuals Comments (0)