NEC Neax 2400 Ipx Office Data Specification
Have a look at the manual NEC Neax 2400 Ipx Office Data Specification online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NDA-24298 CHAPTER 4 Page 867 Issue 1 ACTKC : Assignment of Connection Trunk Data for LDM ACTKC: Assignment of Connection Trunk Data for LDM 1. General This command assigns and deletes the connection trunk data for B-channel/D-channel route by designating the range of trunk numbers and LENS. 2. Precautions 1. This command can be used only when the PBX and the MAT are connected in on-line state. 3. Data Entry Instruction Note 1:When “Delete” is selected in “KIND” box, the data for “C_RT”, “C_TK” and “STEP” is required. Note 2:When the assignment/deletion is successful, “OK” displays in “STATUS” grid. Otherwise, related error message is provided. CONNECTION ROUTE NUMBER (C_RT) 1-1023CONNECTION TRUNK NUMBER (C_TK) 1-4095CONNECTION EQUIPMENT NUMBER (C_LENS)GROUP NUMBER (GROUP) 0-31LEVEL NUMBER (LEVEL) 0-7 COUNT UP STEP (STEP) 1-10COUNT UP TYPE (TYPE) 1-6STATUS STEP Specify the interval between the consecutive connection trunk numbers to be assigned/deleted. Ex. C_TK (START)=1, STEP=3 is entered, connection trunk number is assigned/deleted as follows; [1, 4, 7, 10, 13, 16, ......] LEVEL Enter the first/last level number. START ENDSTART ENDSTART ENDSTART END C_TK The connection trunk controlled by the connection route. Enter the range of trunk numbers to be assigned/deleted.TYPE This parameter determines how to arrange the trunk data. Refer to the next pages for more detail explanation. 1: LEVEL 2: LEVEL 3: GROUP 4: GROUP 5: UNIT 6: UNIT→ → → → → →GROUP UNIT UNIT LEVEL LEVEL GROUP→ → → → → →UNIT GROUP LEVEL UNIT GROUP LEVELC_LENS LENS of the trunk for B- channel and D-channel. C_RT The route assigned for B-channel and D-channel. Enter the first/last group number.GROUP
CHAPTER 4 NDA-24298 Page 868 Issue 1 ACTKC : Assignment of Connection Trunk Data for LDM [Details on Trunk Arrangement “TYPE”] When assigning the consecutive trunk data using the ACTKC command, you must select the trunk arrangement type (1-6) in the “TYPE” parameter. The following examples apply when the 16 COT circuit cards are accommodated: TYPE=1 (Level → Group → Unit) Trunk data is arranged in the following numerical order: U=2 00 PIM C/EU=3 05 10 15 20 16 C O PIM C/E U=0U=1 T 16 C O T 16 C O T16 C O T 16 C O T16 C O T LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 2 3 4 5 6 7 8 029 16 0325 32 0517 24 04 49 5657 64 05 06 U=2 U=0 03 02 33 40 00 41 48 01 73 8065 72 16 15 U=3 U=1 81 8889 96 Group No. Level No. 1MGSlot No.
NDA-24298 CHAPTER 4 Page 869 Issue 1 ACTKC : Assignment of Connection Trunk Data for LDM TYPE=2 (Level → Unit → Group) Trunk data is arranged in the following numerical order: TYPE=3 (Group → Level → Unit) Trunk data is arranged in the following numerical order: LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 2 3 4 5 6 7 8 0233 40 0381 88 0565 72 04 17 2449 56 05 06 U=2 U=0 03 02 9 16 00 41 48 01 57 6425 32 16 15 U=3 U=1 73 8089 96 Group No. Level No. 1MGSlot No. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 5 29 024 32 05 49 63 50 64 05 06 U=2 U=0 03 02 33 47 0034 48 01 65 93 16 15 U=3 U=1 68 96 Group No. Level No. 1MGSlot No. 83536 2 033 04 51 52 69 72
CHAPTER 4 NDA-24298 Page 870 Issue 1 ACTKC : Assignment of Connection Trunk Data for LDM TYPE=4 (Group → Unit → Level) Trunk data is arranged in the following numerical order: TYPE=5 (Unit → Level → Group) Trunk data is arranged in the following numerical order: LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 13 85 024 88 05 7 91 8 92 05 06 U=2 U=0 03 02 5 89 006 90 01 9 93 16 15 U=3 U=1 12 96 Group No. Level No. 1MGSlot No. 16 17 18 2 033 04 19 20 21 24 LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 5 29 0281 95 05 3 31 35 63 05 06 U=2 U=0 03 02 2 30 0034 62 01 4 32 16 15 U=3 U=1 82 96 Group No. Level No. 1MGSlot No. 83 6 38 33 0365 04739 8 84 64 80 40 68 36 66 37 67 61 79
NDA-24298 CHAPTER 4 Page 871 Issue 1 ACTKC : Assignment of Connection Trunk Data for LDM TYPE=6 (Unit → Group → Level) Trunk data is arranged in the following numerical order: LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 13 85 0211 95 05 3 87 7 91 05 06 U=2 U=0 03 02 2 86 006 90 01 4 89 16 15 U=3 U=1 12 96 Group No. Level No. 1MGSlot No. 23 14 18 5 039 04 15 19 16 24 92 94 20 22 810 17 21 89 93
CHAPTER 4 NDA-24298 Page 872 Issue 1 ACTKC : Assignment of Connection Trunk Data for LDM 4. Data Sheet CONNECTION ROUTE NUMBER (C_RT) 1-1023CONNECTION TRUNK NUMBER (C_TK) 1-4095COUNT UP STEP (STEP) 1-10CONNECTION EQUIPMENT NUMBER (C_LENS)GROUP NUMBER (GROUP) 0-31LEVEL NUMBER (LEVEL) 0-7COUNT UP TYPE (TYPE) 1-6STATUS START END START END START END START END
NDA-24298 CHAPTER 4 Page 873 Issue 1 AFCH : Assignment of FCCH Number for Local Data Memory AFCH: Assignment of FCCH Number for Local Data Memory 1. General This command assigns the FCCH card that provides the D-channel in the Fusion Network link. 2. Precautions 1. Before executing this command, the trunk for D-channel should be assigned by the ACRD/ACTK commands. 2. Use sequential numbers starting from 1 at each node. 3. Assign odd numbers for Group and 0 (zero) for Level in the parameter FCHEN. 4. For detailed information, see the NEAX2400 IPX Fusion Network System Manual. 3. Data Entry Instructions FCCH NUMBER (FCHN) 1-255REMARKS FCHN The unique number allocated to the FCH card at each node.FCHEN LENS of the FCH card. 1 2 3LENS OF FCCH (FCHEN) MG U GL 0 0 00 0 00 0 02 2 37 9 10 0 0 Note: FCCH can use Expanded LENS (Group 24 - 31) as well as Physical LENS.
CHAPTER 4 NDA-24298 Page 874 Issue 1 AFCH : Assignment of FCCH Number for Local Data Memory 4. Data Sheet FCCH NUMBER (FCHN) 1-255LENS OF FCCH (FCHEN) REMARKS MG U G L 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NDA-24298 CHAPTER 4 Page 875 Issue 1 AFPC : Assignment of FCCH Routing Data for Local Data Memory AFPC: Assignment of FCCH Routing Data for Local Data Memory 1. General This command assigns the B-channel and the D-channel data for each FPC. 2. Precautions 1. The maximum number of alternative connection trunks is 8 for 1 FPC. 2. The maximum number of the alternative FCH cards is 8 for 1 destination FPC. (In Fusion Link using the FCH card.) 3. The maximum number of the alternative FPCs is 8 for 1 destination FPC. (In Fusion Link using the LANI card.) 4. When FCCH = 0 (The FCH card is not used), assign the Fusion Point Code Number of the final destination to the parameter FPCN. 5. When FCCH = 1 (The FCH card is used), assign the FCCH number to the parameter FCHN. 6. For more detailed information, see the NEAX2400 IPX Fusion Network System Manual.
CHAPTER 4 NDA-24298 Page 876 Issue 1 AFPC : Assignment of FCCH Routing Data for Local Data Memory 3. Data Entry Instructions Note 1:“USE_GATE” data is automatically set and this parameter won’t appear on the MAT display. Note 2:It depends on the assignment on P_ROUTE parameter, whether the direct connection or FCH connection routing is selected. In redundant configuration of internal LAN, #A/#B system changeover is to be activated in case all the routes, both for direct connection and FCH connection, are unable to communicate. According to the P_ROUTE assignment, the route is selected in the following order; When “0=FCCH” is selected, #A direct connection → FCH #A → #B direct connection → FCH #B or #B direct connection → FCH #B → #A direct connection → FCH #A When “1=FGH” is selected, FCH #A → #A direct connection → FCH #B → #B direct connection or FCH #B → #B direct connection → FCH #A → #A direct connection 123 45 678 10 10 10 10 10 10 10 10 11 11 11 11 11 11 11 11 CONNECTION ROUTE (C_RT) 1-1023 FCCH NUMBER/FUSION POINT CODE NUMBER (FCHN/FPCN) 1-255/1-253CNT FUSION POINT CODE (FPC) 1-253 FCCH USE OR NOT USE (FCCH) 0/1GATEWAY FUNCTION USE (USE_GATE) 0/1PRIORITY ROUTE (P_ROUTE) 0/1 91 FPC C_RTFCCH FCHN/FPCN The Connection Route (B-channel)If FCCH = 0 (FCH card is not used.), assign Fusion Point Code Number of the final destination node. If FCCH = 1(FCH card is used), assign the FCCH number FPC is the unique number allocated to each node. Assign FPC of the final destination node in this parameter.0 = The FCH card is not used 1 = The FCH card is used USE_GATE 0 = Gateway Function is not used 1 = Gateway Function is used Note 1P_ROUTE 0 = FCCH 1 = FGH Note 2