    							NDA-24298 CHAPTER 4
    Page 867
    Issue 1
    ACTKC : Assignment of Connection Trunk Data for LDM
    ACTKC: Assignment of Connection Trunk Data for LDM
    1. General
    This command assigns and deletes the connection trunk data for B-channel/D-channel route by designating the
    range of trunk numbers and LENS.
    2. Precautions
    1. This command can be used only when the PBX and the MAT are connected in on-line state.
    3. Data Entry Instruction
    Note 1:When “Delete” is selected in “KIND” box, the data for “C_RT”, “C_TK” and “STEP” is required.
    Note 2:When the assignment/deletion is successful, “OK” displays in “STATUS” grid. Otherwise, related error
    message is provided.
    CONNECTION
    ROUTE
    NUMBER
    (C_RT)
    1-1023CONNECTION
    TRUNK NUMBER
    (C_TK)
    1-4095CONNECTION
    EQUIPMENT
    NUMBER
    (C_LENS)GROUP 
    NUMBER
    (GROUP)
    0-31LEVEL
    NUMBER
    (LEVEL)
    0-7 COUNT
    UP
    STEP
    (STEP)
    1-10COUNT
    UP
    TYPE
    (TYPE)
    1-6STATUS
    STEP
    Specify the interval between the consecutive connection 
    trunk numbers to be assigned/deleted.
    Ex.  C_TK (START)=1, STEP=3 is entered, connection 
    trunk number is assigned/deleted as follows;
            [1, 4, 7, 10, 13, 16, ......]
    LEVEL
    Enter the first/last 
    level number.
    START ENDSTART ENDSTART ENDSTART END
    C_TK
    The connection trunk controlled 
    by the connection route. Enter the 
    range of trunk numbers to be 
    assigned/deleted.TYPE
    This parameter determines how to 
    arrange the trunk data. Refer to the 
    next pages for more detail 
    explanation.
    1:  LEVEL
    2:  LEVEL
    3:  GROUP
    4:  GROUP
    5:  UNIT
    6:  UNIT→
    →
    →
    →
    →
    →GROUP
    UNIT
    UNIT
    LEVEL
    LEVEL
    GROUP→
    →
    →
    →
    →
    →UNIT
    GROUP
    LEVEL
    UNIT
    GROUP
    LEVELC_LENS
    LENS of the trunk for B- 
    channel and D-channel.
    C_RT
    The route assigned for 
    B-channel and D-channel.
    Enter the first/last 
    group number.GROUP 
    						
    							CHAPTER 4 NDA-24298
    Page 868
    Issue 1
    ACTKC : Assignment of Connection Trunk Data for LDM
    [Details on Trunk Arrangement “TYPE”]
    When assigning the consecutive trunk data using the ACTKC command, you must select the trunk arrangement
    type (1-6) in the “TYPE” parameter.
    The following examples apply when the 16 COT circuit cards are accommodated:
    TYPE=1 (Level → Group → Unit)
    Trunk data is arranged in the following numerical order:
    U=2
    00
    PIM C/EU=3
    05 10 15 20
    16
    C
    O
    PIM C/E
    U=0U=1
    T
    16
    C
    O
    T 16
    C
    O
    T16
    C
    O
    T 16
    C
    O
    T16
    C
    O
    T
    LV 7
    LV 6
    LV 5
    LV 4
    LV 3
    LV 2
    LV 1
    LV 0
    LV 0 LV 1
    LV 2 LV 3 LV 4
    LV 5
    LV 6
    LV 71
    2
    3 4 5
    6
    7
    8
    029 16
    0325 32
    0517 24
    04
    49 5657
    64
    05 06
    U=2
    U=0
    03 02 33 40
    00
    41 48
    01
    73 8065
    72
    16 15
    U=3
    U=1
    81 8889
    96
    Group No. Level No.
    1MGSlot No. 
    						
    							NDA-24298 CHAPTER 4
    Page 869
    Issue 1
    ACTKC : Assignment of Connection Trunk Data for LDM
    TYPE=2 (Level → Unit → Group)
    Trunk data is arranged in the following numerical order:
    TYPE=3 (Group → Level → Unit)
    Trunk data is arranged in the following numerical order:
    LV 7
    LV 6
    LV 5
    LV 4
    LV 3
    LV 2
    LV 1
    LV 0
    LV 0 LV 1 LV 2 LV 3
    LV 4
    LV 5
    LV 6
    LV 71
    2 3 4
    5
    6
    7
    8
    0233 40
    0381 88
    0565 72
    04
    17 2449
    56
    05 06
    U=2
    U=0
    03 02 9 16
    00
    41 48
    01
    57 6425
    32
    16 15
    U=3
    U=1
    73 8089
    96
    Group No. Level No.
    1MGSlot No.
    LV 7
    LV 6
    LV 5
    LV 4
    LV 3
    LV 2
    LV 1
    LV 0
    LV 0 LV 1
    LV 2
    LV 3
    LV 4
    LV 5
    LV 6
    LV 71
    5 29
    024 32
    05 49 63
    50 64
    05 06
    U=2
    U=0
    03 02 33 47
    0034 48
    01 65 93
    16 15
    U=3
    U=1
    68 96
    Group No. Level No.
    1MGSlot No.
    83536
    2
    033
    04 51 52 69 72 
    						
    							CHAPTER 4 NDA-24298
    Page 870
    Issue 1
    ACTKC : Assignment of Connection Trunk Data for LDM
    TYPE=4 (Group → Unit → Level)
    Trunk data is arranged in the following numerical order:
    TYPE=5 (Unit → Level → Group)
    Trunk data is arranged in the following numerical order:
    LV 7
    LV 6
    LV 5
    LV 4
    LV 3
    LV 2
    LV 1
    LV 0
    LV 0 LV 1
    LV 2
    LV 3
    LV 4
    LV 5
    LV 6
    LV 71 13 85
    024 88
    05 7 91
    8 92
    05 06
    U=2
    U=0
    03 02 5 89
    006 90
    01 9 93
    16 15
    U=3
    U=1
    12 96
    Group No. Level No.
    1MGSlot No.
    16 17 18
    2
    033
    04 19 20 21 24
    LV 7
    LV 6
    LV 5
    LV 4
    LV 3
    LV 2
    LV 1
    LV 0
    LV 0 LV 1
    LV 2
    LV 3
    LV 4
    LV 5
    LV 6
    LV 71
    5 29
    0281 95
    05 3 31
    35 63
    05 06
    U=2
    U=0
    03 02 2 30
    0034 62
    01 4 32
    16 15
    U=3
    U=1
    82 96
    Group No. Level No.
    1MGSlot No.
    83 6 38
    33
    0365
    04739 8 84
    64 80
    40 68
    36 66
    37 67 61 79 
    						
    							NDA-24298 CHAPTER 4
    Page 871
    Issue 1
    ACTKC : Assignment of Connection Trunk Data for LDM
    TYPE=6 (Unit → Group → Level)
    Trunk data is arranged in the following numerical order:
    LV 7
    LV 6
    LV 5
    LV 4
    LV 3
    LV 2
    LV 1
    LV 0
    LV 0 LV 1
    LV 2
    LV 3
    LV 4
    LV 5
    LV 6
    LV 71 13 85
    0211 95
    05 3 87
    7 91
    05 06
    U=2
    U=0
    03 02 2 86
    006 90
    01 4 89
    16 15
    U=3
    U=1
    12 96
    Group No. Level No.
    1MGSlot No.
    23 14 18
    5
    039
    04 15 19 16 24
    92 94
    20 22
    810
    17 21 89 93 
    						
    							CHAPTER 4 NDA-24298
    Page 872
    Issue 1
    ACTKC : Assignment of Connection Trunk Data for LDM
    4. Data Sheet
    CONNECTION 
    ROUTE
    NUMBER 
    (C_RT) 
    1-1023CONNECTION 
    TRUNK 
    NUMBER
     (C_TK) 1-4095COUNT 
    UP 
    STEP 
    (STEP) 
    1-10CONNECTION
    EQUIPMENT
    NUMBER
    (C_LENS)GROUP
    NUMBER 
    (GROUP) 
    0-31LEVEL
    NUMBER 
    (LEVEL)
     0-7COUNT 
    UP 
    TYPE 
    (TYPE) 
    1-6STATUS
    START END START END
    START END START END 
    						
    							NDA-24298 CHAPTER 4
    Page 873
    Issue 1
    AFCH : Assignment of FCCH Number for Local Data Memory
    AFCH: Assignment of FCCH Number for Local Data Memory
    1. General
    This command assigns the FCCH card that provides the D-channel in the Fusion Network link.
    2. Precautions
    1. Before executing this command, the trunk for D-channel should be assigned by the ACRD/ACTK
    commands.
    2. Use sequential numbers starting from 1 at each node.
    3. Assign odd numbers for Group and 0 (zero) for Level in the parameter FCHEN.
    4. For detailed information, see the NEAX2400 IPX Fusion Network System Manual. 
    3. Data Entry Instructions
    FCCH NUMBER (FCHN)
                  1-255REMARKS
    FCHN
    The unique number allocated to
    the FCH card at each node.FCHEN
    LENS of the FCH card.
    1
    2
    3LENS OF FCCH  (FCHEN)
    MG U
    GL
    0
    0
    00
    0
    00
    0
    02
    2
    37
    9
    10
    0
    0
    Note:    FCCH can use Expanded LENS (Group 24 - 31)  as well as Physical LENS. 
    						
    							CHAPTER 4 NDA-24298
    Page 874
    Issue 1
    AFCH : Assignment of FCCH Number for Local Data Memory
    4. Data Sheet
    FCCH NUMBER (FCHN)
    1-255LENS OF FCCH (FCHEN)
    REMARKS
    MG U G L
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0
    0 
    						
    							NDA-24298 CHAPTER 4
    Page 875
    Issue 1
    AFPC : Assignment of FCCH Routing Data for Local Data Memory
    AFPC: Assignment of FCCH Routing Data for Local Data Memory
    1. General
    This command assigns the B-channel and the D-channel data for each FPC.
    2. Precautions
    1. The maximum number of alternative connection trunks is 8 for 1 FPC.
    2. The maximum number of the alternative FCH cards is 8 for 1 destination FPC.  (In Fusion Link using the
    FCH card.)
    3. The maximum number of the alternative FPCs is 8 for 1 destination FPC.  (In Fusion Link using the LANI
    card.)
    4. When FCCH = 0 (The FCH card is not used), assign the Fusion Point Code Number of the final
    destination to the parameter FPCN. 
    5. When FCCH = 1 (The FCH card is used), assign the FCCH number to the parameter FCHN.
    6. For more detailed information, see the NEAX2400 IPX Fusion Network System Manual.  
    						
    							CHAPTER 4 NDA-24298
    Page 876
    Issue 1
    AFPC : Assignment of FCCH Routing Data for Local Data Memory
    3. Data Entry Instructions
    Note 1:“USE_GATE” data is automatically set and this parameter won’t appear on the MAT display.
    Note 2:It depends on the assignment on P_ROUTE parameter, whether the direct connection or FCH connection
    routing is selected.
    In redundant configuration of internal LAN, #A/#B system changeover is to be activated in case all the
    routes, both for direct connection and FCH connection, are unable to communicate.
    According to the P_ROUTE assignment, the route is selected in the following order;
    When “0=FCCH” is selected,
    #A direct connection 
    → FCH #A → #B direct connection → FCH #B
    or
    #B direct connection 
    → FCH #B → #A direct connection → FCH #A
    When “1=FGH” is selected,
    FCH #A 
    → #A direct connection → FCH #B → #B direct connection
    or
    FCH #B 
    → #B direct connection → FCH #A → #A direct connection
    123
    45 678
    10           10            10           10            10           10            10            10 
    11            11            11           11           11           11            11            11 CONNECTION ROUTE
                (C_RT)
                1-1023 
    FCCH NUMBER/FUSION
     POINT CODE NUMBER
    (FCHN/FPCN) 1-255/1-253CNT FUSION POINT
      CODE (FPC)
          1-253 FCCH USE OR
    NOT USE (FCCH)
              0/1GATEWAY FUNCTION
    USE
    (USE_GATE)
    0/1PRIORITY ROUTE
    (P_ROUTE)
    0/1
    91
    FPC
    C_RTFCCH
    FCHN/FPCN
    The Connection Route
    (B-channel)If FCCH = 0 (FCH card is not used.),
    assign Fusion Point Code Number of the final 
    destination node.
    If FCCH = 1(FCH card is used),
    assign the FCCH number FPC is the unique number allocated 
    to each node.
    Assign FPC of the final destination
    node in this parameter.0 = The FCH card is not used
    1 = The FCH card is used
    USE_GATE
    0 = Gateway Function is not used
    1 = Gateway Function is used
    Note 1P_ROUTE
    0 = FCCH
    1 = FGH
    Note 2 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Ipx Office Data Specification