    							NDA-24298 CHAPTER 4
    Page 127
    Issue 1
    ASYD : Assignment of System Data
    1166 000
    b0
    Assign 00 for business 
    systems. 0
    b1
    0b2
    0b3
    0b4
    0b5
    0b6
    0b7
    167 000
    b0
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex.)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATAea
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 128
    Issue 1
    ASYD : Assignment of System Data
    11680
    b0Assign 00 for business 
    systems.
    0
    b1
    0b2Not used
    0b3
    b4
    Off-hook Alarm (service)
    0/1 = Out/In Service
    b5
    Destination for Off-Hook 
    Alarm Termination
    0/1 = Attendant Console/
    Station
    b6
    Destination for Priority Call 
    Termination
    0/1 = Attendant Console/
    Station
    0
    b7Not used
    169 000
    b0
    Assign 00 for business 
    systems. 0
    b1
    0b2
    0b3
    0b4
    0b5
    0b6
    0b7
    1700
    b0
    0b1
    0b2
    0b3
    b4
    Timing Start
    0/1 = Not Required/Required
    0
    b5
    0b6
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex.)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATAea
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 129
    Issue 1
    ASYD : Assignment of System Data
    1171 00
    b0
    Assign 00 for business 
    systems.
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    172 00
    b0
    b1
    b3
    b4
    b5
    b6
    0b7
    173 00
    b0
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    174 00Not used
    175 000
    b0
    Assign 00 for business 
    systems. 0
    b1
    0b2
    0b3
    0b4
    0b5
    0b6
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex.)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATAea
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 130
    Issue 1
    ASYD : Assignment of System Data
    1176 000
    b0
    Assign 00 for business 
    systems. 0
    b1
    0b2
    0b3
    Not used 0b4
    0b5
    0b6
    0b7Not used
    177 000
    b0 ~ b5Not used
    0
    b6
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1178
    Not used
    1790
    b0(for Hotel 
    System)
    0
    b1
    b2
    Automatic Message Waiting Lamp Off service (for HP 
    types)
    0/1 = Out/In Service
    0
    b3Not used
    0
    b4
    Attendant Console Monitor Function
    0/1 = Out/In Service
    0
    b5
    Not used 0b6
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex.)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATAea
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 131
    Issue 1
    ASYD : Assignment of System Data
    1180
    b01
    b12
    b24
    b38
    b416
    b532
    b664
    b7128
    181
    b0256Note:OPC value is expressed by all bits. For example,
    if OPC value is 16, bit values are entered as
    shown below.
    Enter the data into the DATA column in hexadecimal 
    numbers.
    b1512
    b21024
    b32048
    b44096
    b58192
    0
    b6
    0b7
    182
    b01
    Note:DPC0 value is expressed using all 14 bits. For
    example, if DPC0 value is 12, bit values are
    entered as shown below.
    Enter the data into the DATA column in hexadecimal 
    numbers.
    b12
    b24
    b38
    b416
    b532
    b664
    b7128
    183
    b0256
    b1512
    b21024
    b32048
    b44096
    b58192
    0
    b6
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    0 SI180
    SI181b
    7b6b5b4b3b2b1b0
    00010 000
    000000= 10 hex
    = 00 hex
    0 SI182
    SI183b
    7b6b5b4b3b2b1b0
    00001 00
    000000= 0C hex
    = 00 hex 1 
    						
    							CHAPTER 4 NDA-24298
    Page 132
    Issue 1
    ASYD : Assignment of System Data
    1184
    b01
    Note:DPC1 value is expressed using all 14 bits. For
    example, if DPC1 value is 10, bit values are
    entered as shown below.
    Enter the data into the DATA column in hexadecimal 
    numbers.
    b12
    b24
    b38
    b416
    b532
    b664
    b7128
    185
    b0256
    b1512
    b21024
    b32048
    b44096
    b58192
    0
    b6
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    0DPC 1 SI184
    SI185b
    7b6b5b4b3b2b1b0
    DPC 1: Centralized management report Point Code 1
    0 SI184
    SI185b
    7b6b5b4b3b2b1b0
    00001 10
    000000= 0A hex
    = 00 hex 0 
    						
    							NDA-24298 CHAPTER 4
    Page 133
    Issue 1
    ASYD : Assignment of System Data
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1186
    b0
    0/1 = Link Reconnection Not In Service/Link Reconnection In 
    Service
    Note:An Interoffice transfer service is available. For example,
    with No. 7 CCIS, a caller has called outside their own
    office but is actually talking with somebody in their own
    office. This bit is used to reconfigure links so they are not
    wasted in call transfer service.
    b1
    Restriction check based on the caller’s restriction class when the 
    outgoing trunk is using the No. 7 CCIS in a tandem connection.
    0/1 = No Check/Check
    b2Not used
    b3Not used
    b4Serial Call-Loop Release
    0/1 = Out/In Service
    b5
    Clearing of the buffer memory for use in the centralized 
    management report (for CCIS).
    0/1 = Not Necessary/Necessary
    b6CCIS or ISDN
    0/1 = Out/In Service
    b7Centralized Billing Office Code
    0/1 = Ineffective/Effective
    187 00
    Data Bus used for CCH/DCH cards
    0/1 = PM Bus/ISDN Bus 
    						
    							CHAPTER 4 NDA-24298
    Page 134
    Issue 1
    ASYD : Assignment of System Data 
    1188
    b0
    No. 7 CCIS Control System Interoffice Audit Test
    0/1 = Required/Not Required
    Note 1:This system data becomes valid only when activating
    TRK Ineffective Hold Check function of the periodic test.
    Note 2:In No. 7 CCIS service, IAI signal is sent out to the called
    side office in an outgoing connection.
    b1
    MJ/MN lamp on a display panel in the Main office is controlled by 
    error information from Satellite office.
    0/1 = Not Required/Required
    b2
    Not used
    b3
    b4
    b5
    b6
    b7
    1890
    b0
    Not used 0b1
    0b2
    0b3
    b4AC M,  UMB Si gn al “No-Receiving” Timer
    MTC: MISC TIMER COUNTER
    Timer Value = 2 sec 
    × MTC
    (The timer value is the default value 4 seconds when MTC = 0.)
    Note 3:If the IAI signal reaches the called side office, the ACM
    signal is received from the called side office. This timer is
    to be set when the arrival of the ACM signal may be
    delayed in a tandem connection, etc. (Standard
    Assignment = “50 HEX”)
    b5
    b6
    b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    b7b6b5b4b3b2b1b0
    MTCSY189 
    						
    							NDA-24298 CHAPTER 4
    Page 135
    Issue 1
    ASYD : Assignment of System Data
    1190
    b0I/O = Port designation to Host Computer
    AT T 0  P o r t
    (for Hotel
    system)
    b1
    b2
    0b3
    Not used 0b4
    0b5
    0b6b7b6
    0 0 : Port is not used.
    0 1 : Port is used. 0b7
    1910
    b0I/O = Port designation to Host Computer
    AT T 1  P o r t
    (for Hotel system) 0
    b1
    0b2
    0b3
    Not used 0b4
    0b5
    0b6
    0b7
    1920
    b0Not used
    0b1
    b20/1 = -/SP #0 is mounted on the CMG for IPX-UMG system
    b30/1 = -/SP #1 is mounted on the CMG for IPX-UMG system
    b40/1 = -/CMP #0 is mounted on the CMG for IPX-UMG system
    b50/1 = -/CMP #1 is mounted on the CMG for IPX-UMG system
    0
    b6Not used
    0b7
    193 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    b2b1b0b2b1b0
    0 0 0 = Port 0 0 1 1 = Port 3
    0 0 1 = Port 1 1 0 0 = Port 4
    0 1 0 = Port 2 1 0 1 = Port 5
    110 =Port 6
    111 =Port 7
    b2b1b0b2b1b0
    0 0 0 = Port 0 0 1 1 = Port 3
    0 0 1 = Port 1 1 0 0 = Port 4
    0 1 0 = Port 2 1 0 1 = Port 5
    110 =Port 6
    111 =Port 7
    b7b6
    0 0 = Port is not used.
    0 1 = Port is used. 
    						
    							CHAPTER 4 NDA-24298
    Page 136
    Issue 1
    ASYD : Assignment of System Data 
    1194 011
    b0For IPX, assign 01 Hex.
    0
    b1Not used
    0
    b2Not used
    0
    b3Not used
    0
    b4Not used
    0
    b5Not used
    0
    b6Not used
    0
    b7Not used
    195 00
    Not used
    196 00
    Not used
    197 00
    Not used
    1981
    b0
    For IPX, Module Group 0 Side 0.
    (For IPX-UMG system)
    LP00 #0 is mounted on PBI 30 Module (fixed to “1”)
    b1
    For IPX, Module Group 0 Side 1.
    (For IPX-UMG system)
    LP00 #1 is mounted on PBI 30 Module
    0
    b2Not used
    0b3
    b4
    For IPX, Module Group 2 Side 0.
    (For IPX-UMG system)
    LP02 #0 is mounted on PBI 34 Module
    0
    b5
    For IPX, Module Group 2 Side 1.
    (For IPX-UMG system)
    LP02 #1 is mounted on PBI 34 Module
    0
    b6Not used
    0b7
    199
    b0
    For IPX, Module Group 4 Side 0.
    (For IPX-UMG system)
    LP04 #0 is mounted on PBI 38 Module
    b1
    For IPX, Module Group 4 Side 1.
    (For IPX-UMG system)
    LP04 #1 is mounted on PBI 38 Module
    0
    b2Not used
    0b3
    b4
    For IPX, Module Group 6 Side 0.
    (For IPX-UMG system)
    LP06 #0 is mounted on PBI 3C Module
    b5
    For IPX, Module Group 6 Side 1.
    (For IPX-UMG system)
    LP06 #1 is mounted on PBI 3C Module
    0
    b6Not used
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						