NDA-24298 CHAPTER 4 Page 177 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1531SDT card accommodation 0/1 = Not accommodated/Accommodated b1 → MG1, b3 → MG3, b5 → MG5, b7 → MG7 Note 1:The SDT card can be mounted in the odd MG only. 532Fusion Point Code (FPC) of the Center Node (CN) for the Centralized Management Report-Fusion 533 00 Not used 534 b0 Stop Network Data Memory Broadcasting to LCNs from NCN 0/1 = No/Yes Note:This bit stops the automatic broadcasting of Network Data Memory from NCN while network commands are being programmed. This does not stop the NCN from verifying data at the LCN, but stops the data automatically downloading to the LCNs. (For IPX-UMG system) 0 = No Retry (no data retransmission) for data copy error 1 =Retry in service (for dual LAN system) b 1 0 = Data broadcasting at every NDM command execution 1 = Broadcasting by CBCN command execution Note b20 = Data Broadcasting via CMP 1 = Data Broadcasting via SPNote b3 0 = System Message unnecessary for error during Periodic Refresh 1 = System message necessary for error during Periodic RefreshNote b4System Message Output 0/1 = Out of service/In serviceNote b5 b6 b7 0 = NDM Data en bloc broadcasting (from NCN to All LNs) 1 = NDM Data individual broadcasting (from NDN to the LN) 535-575 00 Not used Note: This data is valid for IPX-UMG system. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 178 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1576 b0Fusion Centralized SMDR Service (Polling Method) 0/1 = No/Yes b1 SMDR for Fusion Network station-to-station calls 0/1 = All Station Calls/Fusion Station Calls only Note:Data valid only when ASYDL Index 512 is set. Valid for IPX Version 2 software or higher. b2 SMDR Interface Type 0/1 = RS232C/LANI b3 Output the System Message related to connection down when the system changeover occurs on LAN Interface for SMDR. 0/1 = Invalid/Valid b4 ~ b7Not used 577 b0~ b7 FPC (Fusion Point Code) of the Center node (CN) for the Centralized SMDR (Centralized Billing-Fusion). FPC: 1-253 (01 Hex-FD Hex.) Note:Data 01 Hex-FD Hex should be assigned at the Local Node (LN) for the Centralized Billing-Fusion. Data “00” must be fixedly assigned at the Center Node (CN) of Centralized Billing-Fusion. 578 b0 Centralized Billing-Fusion output text format of SMDR A 0/1 = ICS format/IPX format b1 ~ b3Not used b40/1 = SMDR A Apparatus with LAN interface is not used/used. Note b5 ~ b7 Not used 579 b0 Centralized Billing-Fusion output text format of SMDR B 0/1 = ICS format/IPX format b1 ~ b3Not used b40/1= SMDR B Apparatus with LAN interface is not used/used. Note b5 ~ b7Not used Note: Assign “1” at the node to which SMDR with LAN interface is connected. If not connected, this data setting is fixed to “0.” SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 179 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1580 b0 Centralized Billing-Fusion output text format of SMDR C 0/1 = IMS (ICS) format/IPX format b1 ~ b3Not used b40/1 = SMDR C Apparatus with LAN interface is not used/used. Note b5 ~ b7Not used 581 b0 Centralized Billing-Fusion output text format of SMDR D 0/1 = ICS format/IPX format b1 ~ b3Not used b40/1 = SMDR D Apparatus with LAN interface is not used/used. Note b5 ~ b7Not used 582 b0 ~ b3 The number of the node to be polled in a polling 0000 = 1 0001 = 1 0010 = 2 0011 = 3 0100 = 4 0101 = 5 0110 = 6 0111 = 7 1000 = 8 ~ 1111 = 8 Note 1:For numbers more than 8, assign the data value as 8. b4 ~ b7Not used 583 b0 ~ b2 The timing for transmitting the billing data of SMDR- Netfusing from the node that accommodates the outgoing trunk to the node that accommodates the called station. b2b1b0b2b1b0 0 0 0 = 8 sec. 1 0 0 = 8 sec. 0 0 1 = 2 sec. 1 0 1 = 10 sec. 0 1 0 = 4 sec. 1 1 0 = 12 sec. 0 1 1 = 6 sec. 1 1 1 = 14 sec. b3 ~ b6Not used b7 The timing for transmitting the polled billing data assigned at b0 ~ b2 is 0= In Service Note: Assign “1” at the node to which SMDR with LAN interface is connected. If not connected, this data setting is fixed to “0”. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 180 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1584 b0 ~ b7 Designate the Polling cycle within the Self Node (for IPX- UMG system only) by the number of calls intended for Poll- ing of the system. Assign this data to default value “0” or “8” in case the number of calls is within 675,000 calls per a day. Actual setting is measured declining 30% of calls in the fol- lowing values on the list: 585b0 ~ b7 Designate the Polling cycle between the Nodes (for Center Node only). When a LN among multiple LNs is set as the Center Node of CCIS Centralized Billing, Polling cycle is to be changed to prevent from Buffer Overflow in LNs. Usual- ly assign the default value “0 (2 seconds cycle)” . 586 b0 ~ b7 Set the upper limit of polling buffer rate (01%-99%) at Centralized Billing Node. Example: Note:If the value exceeds the assigned limit, polling is not activated. In case 00Hex is assigned to b0 ~ b7, the data is to be assigned to the standard rate 50%. 587-607 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT Call/day System Data ~5,400,000 1 ~2,700,000 2 ~1,800,000 3 ~1,350,000 4 ~1,080,000 5 ~900,000 6 ~770,000 7 ~675,000 8 Call/day System Data ~600,000 9 ~540,000 10 ~490,000 11 ~450,000 12 ~400,000 13 ~385,000 14 ~360,000 15 ~337,000 16 Polling Cycle System Data 0.25s 1 0.50s 2 0.75s 3 1.00s 4 1.25s 5 1.50s 6 1.75s 7 2.00s 8 Polling Cycle System Data 2.25s 9 2.50s 10 2.75s 11 3.00s 12 3.25s 13 3.50s 14 3.75s 15 4.00s 16 b7b6b5b4b3b2b1b0 Unit Te n s 80 10 000 000 b 7b6b5b4b3b2b1b0
NDA-24298 CHAPTER 4 Page 181 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1608 The Fusion Point Code (FPC) of the polling destination. FPCs range from 1 to 253 as shown in the table below. Assign data “1 (Polling destination of Centralized Billing-Fusion)” for the corresponding FPC node. Note:This data should be assigned at the Center node for the Centralized Billing-Fusion. 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT INDEXb7b6b5b4b3b2b1b0 608 7654321 - 609 151413121110 9 8 610 2322212019181716 611 3130292827262524 612 3938373635343332 613 4746454443424140 614 5554535251504948 615 6362616059585756 616 7170696867666564 617 7978777675747372 618 8786858483828180 619 9594939291908988 620 103 102 101 100 99 98 97 96 621 111 110 109 108 107 106 105 104 622 119 118 117 116 115 114 113 112 623 127 126 125 124 123 122 121 120 624 135 134 133 132 131 130 129 128 625 143 142 141 140 139 138 137 136 626 151 150 149 148 147 146 145 144 627 159 158 157 156 155 154 153 152 628 167 166 165 164 163 162 161 160 629 175 174 173 172 171 170 169 168 630 183 182 181 180 179 178 177 176 631 191 190 189 188 187 186 185 184 632 199 198 197 196 195 194 193 192 633 207 206 205 204 203 202 201 200 634 215 214 213 212 211 210 209 208 635 223 222 221 220 219 218 217 216 636 231 230 229 228 227 226 225 224 637 239 238 237 236 235 234 233 232 638 247 246 245 244 243 242 241 240 639 - - 253 252 251 250 249 248
CHAPTER 4 NDA-24298 Page 182 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1640 b0Fusion Point Code (FPC) of the node providing ATT- CON. Assign FPC of a terminating node for operator calls from other nodes and Ring Down (IC) calls from PSTN. FPC: 1-253 (01 Hex-FD Hex) Note:This data is necessary at all nodes. Assign the self FPC at the terminating node.b1 b2 b3 b4 b5 b6 b7 641 b0 Designation of output numbers for SMDR ICS format. 0/1 = Physical (station) number/Telephone number Note:This data is valid when the text format of SMDR is “ICS format,” and the number of digits for Telephone number is 6 or less. b1 Designation of output numbers for MCI ICS format. 0/1=Physical (station) number/Telephone number Note:This data is valid when the text format of MCI is “ICS format,” and the number of digits for Telephone number is 6 or less. 0 b2Not used b3 Designation of output routes for SMDR ICS format. 0/1 = Physical route/Logical route Note:This data is valid when the text format of SMDR is “ICS format.” 0 b4~b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 183 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1642 Speech Path Memory of TONE ROM source selection for Voice Prompt Service. 0/1 = TONE ROM/Speech Path Memory 643 644 645 646 Speech Path Memory of MUSIC ROM source selections for Voice Prompt Service. 0/1 = MUSIC ROM/Speech Path Memory 647 648 649 650~671 Not used 672 b0 Telephone number display location on Dterm Note:See the example on the next page. b1 Not used b2 b3 b4 b5 b6 b7 673 - 703 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT INDEXb7b6b5b4b3b2b1b0 642 ch7 ch6 ch5 ch4 ch3 ch2 ch1 ch0 643 ch15 ch14 ch13 ch12 ch11 ch10 ch9 ch8 644 ch23 ch22 ch21 ch20 ch19 ch18 ch17 ch16 645 ch31 ch30 ch29 ch28 ch27 ch26 ch25 ch24 INDEXb7b6b5b4b3b2b1b0 646 ch7 ch6 ch5 ch4 ch3 ch2 ch1 ch0 647 ch15 ch14 ch13 ch12 ch11 ch10 ch9 ch8 648 ch23 ch22 ch21 ch20 ch19 ch18 ch17 ch16 649 ch29 ch28 ch27 ch26 ch25 ch24
CHAPTER 4 NDA-24298 Page 184 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) Example: When a call terminates on a Dterm from Telephone number 123456789, the Dterm displays as follows depending on the data settings. 23456789 11:20 AM WED 16 APR 1997 MIC DND >>> 123456789 MIC DND >>> ASYDL SYS1,INDEX672,Bit0=0 8 digits long maximum when Telephone Number is displayed on top line. ASYDL SYS1,INDEX672,Bit0=1
NDA-24298 CHAPTER 4 Page 185 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1704 Fusion Point Code (FPC) of the node to which ATT-CON transfers the Day/ Night changeover information. FPCs range from 1 to 253 as shown in the table below. Assign data “1 (D/N changeover information is transferred)” for the corresponding node. Note:This data is necessary at the node providing ATT-CON. 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 - 799 Not used INDEXb7b6b5b4b3b2b1b0 704 76543210 705 151413121110 9 8 706 2322212019181716 707 3130292827262524 708 3938373635343332 709 4746454443424140 710 5554535251504948 711 6362616059585756 712 7170696867666564 713 7978777675747372 714 8786858483828180 715 9594939291908988 716 103 102 101 100 99 98 97 96 717 111 110 109 108 107 106 105 104 718 119 118 117 116 115 114 113 112 719 127 126 125 124 123 122 121 120 720 135 134 133 132 131 130 129 128 721 143 142 141 140 139 138 137 136 722 151 150 149 148 147 146 145 144 723 159 158 157 156 155 154 153 152 724 167 166 165 164 163 162 161 160 725 175 174 173 172 171 170 169 168 726 183 182 181 180 179 178 177 176 727 191 190 189 188 187 186 185 184 728 199 198 197 196 195 194 193 192 729 207 206 205 204 203 202 201 200 730 215 214 213 212 211 210 209 208 731 223 222 221 220 219 218 217 216 732 231 230 229 228 227 226 225 224 733 239 238 237 236 235 234 233 232 734 247 246 245 244 243 242 241 240 735 - - 253 252 251 250 249 248
CHAPTER 4 NDA-24298 Page 186 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1800 b0 ALGNL/ALGSL command tenant User Group Number (UGN) table development of Local Data Memory (LDM) 0/1 = Separate/Common b1 ASPAL command tenant table development of Local Data Memory (LDM) 0/1 = Separate/Common b2 ANPDL command tenant data table development of Local Data Memory (LDM) 0/1 = Separate/Common b3 APCNL command tenant data table development of Local Data Memory (LDM) 0/1 = Separate/Common b4 AFRSL, ASTPL, AUNEL command tenant data table development of Local Data Memory (LDM) 0/1 = Separate/Common b5 ASTPL command tenant data table development of Local Data Memory (LDM) 0/1 = Separate/Common b6Not used b7 AAEDL command tenant data table development of Local Data Memory (LDM) 0/1 = Separate/Common 801-802 00Not used 803 b0Not used b1Consultation Hold Release 0/1 = Out of service/In service b2 Operation from the stations in Add On Conference - 8 Party Service 0/1 = Operation is invalid/Valid b3 - b7Not used 804 b0 Kind of tone when a call is transferred from Attendant Console in case all the stations in a UCD group are busy; 0/1 = BT/RBT b1Transferring the busy information of Logical Route 0/1 = Out of service/In service b2Not used b3The number of digit for Internal Zone Paging group ID 0/1 = 2 digits/3 digits b4 UCD Announcement Information 0 = Individual setting for each UCD group 1 = Common in all the UCD groups 0b5 ~ b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT