    							NDA-24298 CHAPTER 4
    Page 767
    Issue 1
    ANCD : Assignment of Night Connection Data
    4. Data Sheet
    MODULE
    GROUP
    NUMBER
    (MG)
    00 - 31PFT
    CARD
    NUMBER
    (NCU
    PKG)
    0 - 3PORT
    NUMBER OF
    PFT CARD
    (PORT)
    0 - 11ROUTE 
    NUMBER
    (RT)
    1-255TRUNK 
    NUMBER
    (TK)REMARKS
    0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11 
    						
    							CHAPTER 4 NDA-24298
    Page 768
    Issue 1
    ANCD_LR : Assignment of Night Connection Data – Logical Route Number
    ANCD_LR: Assignment of Night Connection Data – Logical Route Number
    1. General
    This command is used when the Power Failure Transfer (PFT) circuit card is controlled by the external key.
    Route data of the ANCD command can be assigned by logical route number.
    2. Precautions
    1. Prior to this command, logical route data must be allocated by using the ALRTN command.
    2. Only when logging in to the NCN (Network Control Node), this command can be used to assign the
    logical route data of self-Node and the other Nodes in the Fusion Network. If logging in to a LN (Local
    Node), data setting only for the self-node is available. (Error message is indicated if you try to write the
    data of other Node.)
    3. When the “PFT control by the external key” is required, the following data assignments are needed:
    (a) AUNT command, TYPE = 2 (PFT)
    (b) AEKD command
    (c) ANCD/ANCD_LR command
    (d) ACSI command, CSI = 4 (Direct-in Termination (Night Mode))
    3. Data Entry Instructions
    FUSION
    POINT
    CODE
    (FPC)
    1-253MODULE 
    GROUP
    NUMBER
    (MG)PORT 
    NUMBER 
    OF PFT 
    CARD 
    (PORT)
     0-11 PFT CARD 
    NUMBER 
    (NCU PKG)
    0-3OUTSIDE 
    ROUTE
    NUMBER 
    (RT) LOGICAL
    ROUTE
    NUMBER 
    (LGRT)
    1-899REMARKS TRUNK
    NUMBER 
    (TK)
    1-255
    MG
    Enter the data of PFT card assigned by the AUNT 
    command.
    LGRT
    Enter the logical route number allocated to the 
    external route number.
    TK
    Enter the trunk number connected to the corresponding 
    circuit number of PFT card.FPC
    Enter the FPC of target Node only when logging 
    in to the NCN (Network Control Node).
    PORT
    The port parameter corresponds to the circuit 
    number of the PFT card. 
    						
    							NDA-24298 CHAPTER 4
    Page 769
    Issue 1
    ANCD_LR : Assignment of Night Connection Data – Logical Route Number
    4. Data Sheet
    FUSION 
    POINT 
    CODE 
    (FPC)
    1-253MODULE
    GROUP
    NUMBER
    (MG)PFT CARD
    NUMBER
    (NCU PKG)
    0 - 3PORT
    NUMBER 
    OF PFT 
    CARD
    (PORT)
    0 - 11LOGICAL 
    ROUTE 
    NUMBER
    (LGRT)
    1-899OUTSIDE 
    ROUTE 
    NUMBER
    (RT)TRUNK 
    NUMBER
    (TK)
    1-255REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 770
    Issue 1
    ATAS : Assignment TAS Service Data
    ATAS: Assignment TAS Service Data
    1. General
    This command assigns the data related to the Trunk Answer From Any Station (TAS) service feature.
    2. Precautions
    1. One tenant can be provided one TAS indicator.
    2. The TAS answer access code is assigned by the ASPA command, SRV = SSC, SID = 16.
    3. The TAS answering capability is assigned by the ASFC command, SFI=13 and the ACFR command,
    TSFI = 5. 
    4. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8. If
    data for this command is common for all tenants (ASYD command, SYS1, INDEX 93, bit2 = 1), assign
    TN parameter as data “1” for all tenants.
    3. Data Entry Instructions
    TENANT NUMBER 
    (TN)UNIT NUMBER 
    (UNIT) 
    0-3 MODULE GROUP 
    NUMBER 
    (MG)CIRCUIT NUMBER 
    (CN)
     0/1REMARKS
    TN
    Enter the tenant number to be applied to the TAS 
    service.
    UNIT
    Enter the Unit number of the TAS indicator. 
    CN MG
    Enter the circuit number of the TAS indicator .
    Enter the module Group number the TAS 
    indicator is mounted. 
    						
    							NDA-24298 CHAPTER 4
    Page 771
    Issue 1
    ATAS : Assignment TAS Service Data
    4. Data Sheet
    TENANT
    NUMBER 
    (TN)MODULE
    GROUP NUMBER
    (MG)MOUNTED UNIT
    NUMBER 
    (UNIT)
    0 - 3CIRCUIT
    NUMBER 
    (CN)
    0/1REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 772
    Issue 1
    AEKD : Assignment of External Key Data
    AEKD: Assignment of External Key Data
    1. General
    This command assigns the External Key related data, which allows a maintenance person to change the system
    over to the Day/Night mode by means of ON/OFF on the PFT circuit card.
    2. Precautions
    1. When the “PFT control by the external key” is required, the following data assignments are needed:
    (a) AUNT command, TYPE = 2 (PFT)
    (b) AEKD command
    (c) ANCD command
    (d) ACSI command, CSI = 4 (Direct-in Termination (Night Mode))
    2. A maximum of eight (0-7) external keys can be assigned, corresponding to each PFT circuit card. The
    external key can control two PFT circuit cards per MG (16 circuits).
    3. Data Entry Instructions
    MODULE
    GROUP
    (MG)
    0-7CIRCUIT
    CARD NO.
    (NCU PKG)
    0/1EXTERNAL
    KEY
    NUMBER
    (CTN)
    0-7CHANGE
    CONTROL
    PATTERN
    (CP)
    1-4TN
    NUMBER OF INPUT TN or RT/TK (CNT)
    1st
    0
    1
    2
    3
    4
    5
    62nd 3rd 4th 5th 6th 7th 8th
    CP
    1 = –
    2 = Day/Night Change
    3 = –
    4 = –TN
    One external key can manage 8 tenants at the 
    maximum 
    						
    							NDA-24298 CHAPTER 4
    Page 773
    Issue 1
    AEKD : Assignment of External Key Data
    4. Data Sheet
    MODULE
    GROUP
    NUMBER
    (MG)
    0-7NCU
    CARD
    NUMBER
    (NCU PKG)
    0/1EXTERNAL
    KEY
    NUMBER
    (CTN)
    0-7CHANGE
    CONTROL
    PAT T E R N
    (CP)
    1-4TENANT NUMBER
    (TN)
    1ST 2ND 3RD 4TH 5TH 6TH 7TH 8TH
    0
    1
    2
    3
    4
    5
    6
    7 
    						
    							CHAPTER 4 NDA-24298
    Page 774
    Issue 1
    AAND : Assignment of Automatic Number Identification Data
    AAND: Assignment of Automatic Number Identification Data
    1. General
    This command assigns ANI data for the number of digits of the calling station number and the office code on
    each route basis for the Automatic Number Identification (ANI) Service. (For E911 ANI)
    2. Precautions
    The route number set in parameter RT should have been designated in ARTD, ANI = 1.
    3. Data Entry Instructions
    STA/ATT
    OUTGOING
    (AT)
    0/1MAIN/
    SATELLITE 
    CENTRAL 
    (CC)
    0/1EXPAN-
    SION 
    OF STA 
    NUMBER 
    LENGTH
     (KT)
    0/1 OUT-
    GOING 
    ROUTE 
    NUMBER 
    (RT)
    AT
    0 = STA outgoing
    1 = ATT outgoing
    These parameters vary depending on 
    the assignment of the previous 
    parameter.
    CENTRAL 
    OFFICE 
    CODE 
    (COC) 
    MAX. 
    5 DIGITSSTA 
    NUMBER 
    LENGTH 
    (STNL) 
    1-8OFFICE
    CODE 
    TO BE 
    ADDED
    (ADD)
    1-10CALL 
    ORIGINA-
    TOR DIGIT 
    TO BE 
    SKIPPED 
    (SKIP)
    0-10OFFICE CODE (DC) 
    MAX. 10 DIGITS
    CC
    0 = Main Central
    1 = Satellite Central
    KT
    0 = OFF     1 = ON 
    						
    							NDA-24298 CHAPTER 4
    Page 775
    Issue 1
    AAND : Assignment of Automatic Number Identification Data
    4. Data Sheet
    (a) When STA/ATT, the Individual Attendant Number, is assigned. Outgoing and Main Central (AT = 0, 
    CC = 0)
     
    Note:This parameter can be assigned when KT = 1.
    ROUTE 
    NUMBER 
    (RT)STA
    OUTGOING/
    AT T
    OUTGOING
    (AT)MAIN
    CENTRAL/
    SATELLITE 
    CENTRAL
     (CC)EXPANSION
     OF STA
    NUMBER 
    LENGTHS 
    (KT)
    0/1STA
    NUMBER 
    LENGTH 
    (STNL)
    1 – 8
    NoteOFFICE 
    CODE TO 
    BE 
    ADDED 
    (ADD)
    1 – 10CALL
    ORIGINATOR
     DIGIT TO BE 
    SKIPPED 
    (SKIP)
    0 – 10OFFICE CODE 
    (DC)
    MAXIMUM 10 DIGITS
    00
    00
    00
    00
    00
    00
    00
    00
    00
    00
    00
    00
    00
    00
    00 
    						
    							CHAPTER 4 NDA-24298
    Page 776
    Issue 1
    AAND : Assignment of Automatic Number Identification Data
    (b) When STA/ATT, the Individual Attendant Number, is assigned. Outgoing and Satellite Central (AT = 
    0, CC = 1)
     
    ROUTE 
    NUMBER 
    (RT)STA
    OUTGOING/
    AT T
    OUTGOING
    (AT)MAIN
    CENTRAL/
    SATELLITE 
    CENTRAL
     (CC)CENTRAL OFFICE CODE 
    (COC)
    MAXIMUM 5 DIGITSOFFICE 
    CODE TO 
    BE 
    ADDED 
    (ADD)
    1 – 10CALL
    ORIGINATOR 
    DIGIT TO BE 
    SKIPPED 
    (SKIP)
    0 – 10OFFICE CODE 
    (DC)
    MAXIMUM 10 DIGITS
    01
    01
    01
    01
    01
    01
    01
    01
    01
    01
    01
    01
    01
    01
    01 
    						