    							NDA-24298 CHAPTER 4
    Page 147
    Issue 1
    ASYD : Assignment of System Data
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1250
    b0 ~ b7
    SMDR output buffer usage rate (00~98%) at the time of output of 
    SMDR Buffer Overflow Alarm Clear message (System Message 
    6-P)
    Note:When this data has been set as specified below, the
    alarm message output value becomes 80% and the
    alarm message clear message output value becomes
    50% regardless of the data.
    When the data of INDEX 249 is smaller than or
    equal to the data of INDEX 250.
    When these data values are not valid.
    251 00
    Not used 252 0
    b0 ~ b7
    253 0b0 ~ b7
    254 0b0 ~ b7
    255 0b0 ~ b7
    2560
    b0
    0b1
    1b2HDD Mounted = 1 (fixed)
    0
    b3Not used
    b4IOC0
    0/1 = Not Mounted/Mounted
    b5IOC1
    0/1 = Not Mounted/Mounted
    0
    b6Not used
    0b7
    b7b6b5b4b3b2b1b0
    Unit
    Tens 
    						
    							CHAPTER 4 NDA-24298
    Page 148
    Issue 1
    ASYD : Assignment of System Data 
    1257
    b0DLKC Circuit Card for Attendant Console (ATTCON)
    0/1 = Not Exist in system/Exist in systemNote 1, Note 2
    0
    b1
    Not used 0
    b2
    0b3
    0b4
    0b5
    0b6
    0b7
    258 00 Not used
    260 00 Not used
    261
    b0
    Not used 0
    b1
    0b2
    0b3
    0b4
    0b5
    0b6
    0b7
    262 00 Not used
    287 00 Not used
    Note 1:Fixed to data “0” for 1-IMG system, whether the ATTCON is used or not .
    Note 2:This data won’t be valid unless it has been assigned before the system initialization.
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ~~~
    ~~~ 
    						
    							NDA-24298 CHAPTER 4
    Page 149
    Issue 1
    ASYD : Assignment of System Data
    1288
    b0Output Port for SMDR A Apparatus
    When b
    4 = 0 (IOC equipment No. 0)
    b
    0 = Port 0 b1 = Port 1  b2 = Port 2b3 = Port 3
    When b
    4 = 1 (IOC equipment No. 1)
    b
    0 = Port 4 b1 = Port 5 b2 = Port 6 b3 = Port 7
    “1” is to be assigned to each bit corresponding to the Port No.
    Note 1, Note 2, Note 3
    b1
    b2
    b3
    b4
    0b5Expanded SMDR for “A” apparatus.
    0
    b6Not used
    0b7
    289
    b0Fault detection timer of SMDR A 
    Value for the first digit (min):
    (0~9) Hex
    A~F Hex: Not usedTimer value ranges 
    from 1 to 99 min-
    utes.
    00 Hex: Without 
    fault detection
    Normally, Assign 00 
    Hex.
    b1
    b2
    b3
    b4Fault detection timer of SMDR A 
    Value for the second digit (min):
    (0~9) Hex
    A~F Hex: Not used
    b5
    b6
    b7
    290
    b0Output Port for SMDR B Apparatus
    When b
    4 = 0 (IOC equipment No. 0)
    b
    0 = Port 0 b1 = Port 1 b2 = Port 2 b3 = Port 3
    When b
    4 = 1 (IOC equipment No. 1)
    b
    0 = Port 4 b1 = Port 5 b2 = Port 6b3 = Port 7
    “1” is to be assigned to each bit corresponding to the Port No.
    Note 1, Note 2, Note 3
    b1
    b2
    b3
    b4
    b5Expanded SMDR for “B” apparatus.
    b6Not usedb7
    Note 1:Among the SMDR equipment that has the same IOC equipment number, double assignment of the port is
    rejected.
    Note 2:The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as
    SMDR by AIOC.
    Note 3:This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not connected
    to the node, this data setting is fixed to “0”.
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 150
    Issue 1
    ASYD : Assignment of System Data 
    1291
    b0Fault detection timer of SMDR B 
    Value for the first digit (min):
    (0~9) Hex
    A~F Hex: Not usedTimer value ranges 
    from 1 to 99 min-
    utes.
    00 Hex: Without 
    fault detection
    Normally, Assign 00 
    Hex.
    b1
    b2
    b3
    b4Fault Detection timer of SMDR B 
    Value for the second digit (min):
    (0~9) Hex
    A~F Hex: Not used
    b5
    b6
    b7
    292
    b0Output Port for SMDR C Apparatus
    When b
    4 = 0 (IOC equipment No. 0)
    b
    0 = Port 0 b1 = Port 1 b2 = Port 2 b3 = Port 3
    When b
    4 = 1 (IOC equipment No. 1)
    b
    0 = Port 4 b1 = Port 5 b2 = Port 6b3 = Port 7
    “1” is to be assigned to each bit corresponding to the Port No.
    Note 1:Among the SMDR equipment that has the same IOC
    equipment number, double assignment of port is
    rejected.
    Note 2:The ports to be designated by SYS-1, INDEX 288, 290,
    292, and 294 are limited to those designated as SMDR
    by AIOC.
    Note 3:This data is assigned at the node to which SMDR with
    IOC interface is connected. In case SMDR is not
    connected to the node, this data setting is fixed to “0”.
    b1
    b2
    b3
    b4
    b5Expanded SMDR for “C” apparatus.
    b6Not usedb7
    293
    b0Fault detection timer of SMDR C 
    Value for the first digit (min):
    (0~9) Hex
    A~F Hex: Not usedTimer value ranges 
    from 1 to 99 min-
    utes.
    00 Hex: Without 
    fault detection
    Normally, Assign 00 
    Hex.
    b1
    b2
    b3
    b4Fault detection timer of SMDR C 
    Value for the second digit (min):
    (0~9) Hex
    A~F Hex: Not used
    b5
    b6
    b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 151
    Issue 1
    ASYD : Assignment of System Data
    1294
    b0Output Port for SMDR D Apparatus
    When b
    4 = 0 (IOC equipment No. 0)
    b
    0 = Port 0 b1 = Port 1 b2 = Port 2  b3 = Port 3
    When b
    4 = 1 (IOC equipment No. 1)
    b
    0 = Port 4 b1 = Port 5 b2 = Port 6 b3 = Port 7
    “1” is to be assigned to each bit corresponding to the Port No.
    Note 1:Among the SMDR equipment that has the same IOC
    equipment number, double assignment of port is
    rejected.
    Note 2:The ports to be designated by SYS-1, INDEX 288, 290,
    292, and 294 are limited to those designated as SMDR
    by AIOC.
    Note 3:This data is assigned at the node to which SMDR with
    IOC interface is connected. In case SMDR is not
    connected to the node, this data setting is fixed to “0”.
    b1
    b2
    b3
    b4
    b5Expanded SMDR for “D” apparatus.
    b6Not usedb7
    295
    b0Fault detection timer of SMDR D 
    Value for the first digit (min):
    (0~9) Hex
    A~F Hex: Not usedTimer value ranges 
    from 1 to 99 min-
    utes.
    00 Hex: Without 
    fault detection
    Normally, Assign 00 
    Hex.
    b1
    b2
    b3
    b4Fault detection timer of SMDR D 
    Value for the second digit (min):
    (0~9) Hex
    A~F Hex: Not used
    b5
    b6
    b7
    296 00 Not used
    303 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ~~~ 
    						
    							CHAPTER 4 NDA-24298
    Page 152
    Issue 1
    ASYD : Assignment of System Data 
    1304
    b0
    Individual Speed Calling Data Save
    0/1 = Out/In Service
    (This data is valid when SYS1, INDEX 90, b
    1 = 1)
    b1
    Call Forwarding Data Save
    0/1 = Out/In Service
    (This data is valid when SYS1, INDEX 90, b
    1 = 1)
    b2PCS Data Save
    0/1 = Out/In Service
    b3
    Name Display Data Save
    0/1 = Out/In Service
    (This data is valid when SYS1, INDEX 90, b
    1 = 1)
    b4
    User Assign Soft Key Data Save
    0/1 = Out/In Service
    (This data is valid when SYS1, INDEX 90, b
    1 = 1)
    b5
    Number Sharing Data Save
    0/1 = Out/In Service
    (This data is valid when SYS1, INDEX 90, b
    1 = 1)
    b6
    Call Block Data Save
    0/1 = Out/In Service
    (This data is valid when SYS1, INDEX 90, b
    1 = 1)
    0
    b7Not used
    305 00 Not used
    320 00 Not used
    321
    b0Inter-Module Group Key Data
    0/1 = No/Yes
    b1Step Call While Transfer to Busy Station
    0/1 = No/Yes
    b2Termination on My Line
    0/1: Not Restricted/Restricted
    0
    b3
    Not used 0b4
    0b5
    0b6
    b7Voice Call Chime
    0/1 = 4/1 Chime
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ~~~ 
    						
    							NDA-24298 CHAPTER 4
    Page 153
    Issue 1
    ASYD : Assignment of System Data
    1322
    b0Timing start to dial Attendant 
    Console Assign digit used
    Note:When SYS-1, INDEX 92, 
    b
    0 = “0” (Individual SYS-2 
    Table Development), prepare 
    separate SYS-2 Programming 
    Sheets for each Tenant (TN).Note:Digits 0-9 are
    used with Index
    17, 
    b5b1
    0b2
    0b3
    0b4Not used
    b5
    Tone to be sent when the handset has been lifted via the Station 
    on which CALL BLOCK service is set.
    0/1 = DT/SPDT
    Note:Valid since the release 5 software.
    b6
    Tone to be heard after the access code for Tone Block is dialed
    0/1 = SPDT/DT
    Note:Valid since release 5 software.
    b7Call Return in case of station-to-station call
    0/1 = Out/In Service
    323 00 Not used
    369 00 Not used
    370
    b0Expanded SMFN service
    0/1 = No/Yes
    b1Delete ARNP RTO on MCI
    0/1 = No/Yes
    b2Non-CCIS originated RT/TK number in SMDR
    0/1 = No/Yes
    b3Att. outbound loop to loop
    0/1 = No/Yes
    b4Release guard timer for S/L
    b5MTC = 0 × 15 milliseconds
    b6MTC × 64 milliseconds
    b7Default 384 milliseconds
    371 00 Not used
    387 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ~~~
    ~~~ 
    						
    							CHAPTER 4 NDA-24298
    Page 154
    Issue 1
    ASYD : Assignment of System Data 
    13880
    b0 - b3Not used
    b4
    The way to answer the Internal Zone Paging call;
    0 = Press the Prime Line key after Off-Hook
    1 = Off-Hook
    Note:Valid for software Release 9 or later.
    0
    b5 - b7Not used
    389
    b0 - b4
    Display Language on Dterm LCD     Note 
    0: English
    1: Portuguese
    2: Spanish
    3: French (For Release 9 software)
    4-31: Not used
    Note:When assigning language, data “0” must be set in
    INDEX78, b4.
    0
    b5 - b7Not used
    390
    b0Caller ID display pattern on the LCD
    0/1 = Calling Name/Calling Number has priority.
    b1Displayed information on the Top line of the LCD of the Dterm 
    0/1 = Caller ID/Call type or sub address
    b2
    Display the Caller ID information on the Dterm that assigned the 
    called number as a sub line. 
    0/1 = Out/In Service
    b3Display of Soft key to be pressed when the station is idle or is in 
    DT connection.
    b4b3
    00:blink
    0 1 : steady-lights
    1 0 : Displays the assigned code on 1st column (*1)
    1 1 : No Indicationb4
    b5Display of Soft key to be pressed when the station is in 
    communication.
    b6b5
    00:blink
    01:–
    1 0 : Displays the assigned code on 1st column (*1)
    1 1 : No Indicationb6
    0b7Not used
    391Assign the first character to indicate the soft key in use. (See 
    Ta b l e  4 - 2.)
    392 - 438 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 155
    Issue 1
    ASYD : Assignment of System Data
    1439
    b0 - b6Not used
    b7
    Station Hunting by call kind
    0/1 = Invalid/Valid
    Note:Available for software Release 9 or later.
    440-485 00 Not used
    486
    b0 ~ b2
    Maximum number of transfer for Multiple Call Forwarding - 
    CCIS occurrences
    b2b1b0b2b1b0
    0 00=This service is invalid100=four times
    0 01=once101=five times
    0 10=twice110=six times
    0 11=three times111=seven times
    Note:Valid when the node is “Call Forwarding-CCIS” start
    node. The number of call forwarding within a node is
    not counted.
    b3 ~ b7Not used
    487 - 511 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
     (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 156
    Issue 1
    ASYD : Assignment of System Data 
    Table 4-2 Assigned Code in 1st Column
    0      1      2      3      4      5      6      7      8      9
    0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    A
    B
    C
    D
    E
    FA      B      C      D      E      F
    *
    Upper 4bit
    Lower 4bit 
    						