NDA-24298 CHAPTER 4 Page 147 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1250 b0 ~ b7 SMDR output buffer usage rate (00~98%) at the time of output of SMDR Buffer Overflow Alarm Clear message (System Message 6-P) Note:When this data has been set as specified below, the alarm message output value becomes 80% and the alarm message clear message output value becomes 50% regardless of the data. When the data of INDEX 249 is smaller than or equal to the data of INDEX 250. When these data values are not valid. 251 00 Not used 252 0 b0 ~ b7 253 0b0 ~ b7 254 0b0 ~ b7 255 0b0 ~ b7 2560 b0 0b1 1b2HDD Mounted = 1 (fixed) 0 b3Not used b4IOC0 0/1 = Not Mounted/Mounted b5IOC1 0/1 = Not Mounted/Mounted 0 b6Not used 0b7 b7b6b5b4b3b2b1b0 Unit Tens
CHAPTER 4 NDA-24298 Page 148 Issue 1 ASYD : Assignment of System Data 1257 b0DLKC Circuit Card for Attendant Console (ATTCON) 0/1 = Not Exist in system/Exist in systemNote 1, Note 2 0 b1 Not used 0 b2 0b3 0b4 0b5 0b6 0b7 258 00 Not used 260 00 Not used 261 b0 Not used 0 b1 0b2 0b3 0b4 0b5 0b6 0b7 262 00 Not used 287 00 Not used Note 1:Fixed to data “0” for 1-IMG system, whether the ATTCON is used or not . Note 2:This data won’t be valid unless it has been assigned before the system initialization. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ~~~ ~~~
NDA-24298 CHAPTER 4 Page 149 Issue 1 ASYD : Assignment of System Data 1288 b0Output Port for SMDR A Apparatus When b 4 = 0 (IOC equipment No. 0) b 0 = Port 0 b1 = Port 1 b2 = Port 2b3 = Port 3 When b 4 = 1 (IOC equipment No. 1) b 0 = Port 4 b1 = Port 5 b2 = Port 6 b3 = Port 7 “1” is to be assigned to each bit corresponding to the Port No. Note 1, Note 2, Note 3 b1 b2 b3 b4 0b5Expanded SMDR for “A” apparatus. 0 b6Not used 0b7 289 b0Fault detection timer of SMDR A Value for the first digit (min): (0~9) Hex A~F Hex: Not usedTimer value ranges from 1 to 99 min- utes. 00 Hex: Without fault detection Normally, Assign 00 Hex. b1 b2 b3 b4Fault detection timer of SMDR A Value for the second digit (min): (0~9) Hex A~F Hex: Not used b5 b6 b7 290 b0Output Port for SMDR B Apparatus When b 4 = 0 (IOC equipment No. 0) b 0 = Port 0 b1 = Port 1 b2 = Port 2 b3 = Port 3 When b 4 = 1 (IOC equipment No. 1) b 0 = Port 4 b1 = Port 5 b2 = Port 6b3 = Port 7 “1” is to be assigned to each bit corresponding to the Port No. Note 1, Note 2, Note 3 b1 b2 b3 b4 b5Expanded SMDR for “B” apparatus. b6Not usedb7 Note 1:Among the SMDR equipment that has the same IOC equipment number, double assignment of the port is rejected. Note 2:The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as SMDR by AIOC. Note 3:This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not connected to the node, this data setting is fixed to “0”. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 150 Issue 1 ASYD : Assignment of System Data 1291 b0Fault detection timer of SMDR B Value for the first digit (min): (0~9) Hex A~F Hex: Not usedTimer value ranges from 1 to 99 min- utes. 00 Hex: Without fault detection Normally, Assign 00 Hex. b1 b2 b3 b4Fault Detection timer of SMDR B Value for the second digit (min): (0~9) Hex A~F Hex: Not used b5 b6 b7 292 b0Output Port for SMDR C Apparatus When b 4 = 0 (IOC equipment No. 0) b 0 = Port 0 b1 = Port 1 b2 = Port 2 b3 = Port 3 When b 4 = 1 (IOC equipment No. 1) b 0 = Port 4 b1 = Port 5 b2 = Port 6b3 = Port 7 “1” is to be assigned to each bit corresponding to the Port No. Note 1:Among the SMDR equipment that has the same IOC equipment number, double assignment of port is rejected. Note 2:The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as SMDR by AIOC. Note 3:This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not connected to the node, this data setting is fixed to “0”. b1 b2 b3 b4 b5Expanded SMDR for “C” apparatus. b6Not usedb7 293 b0Fault detection timer of SMDR C Value for the first digit (min): (0~9) Hex A~F Hex: Not usedTimer value ranges from 1 to 99 min- utes. 00 Hex: Without fault detection Normally, Assign 00 Hex. b1 b2 b3 b4Fault detection timer of SMDR C Value for the second digit (min): (0~9) Hex A~F Hex: Not used b5 b6 b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 151 Issue 1 ASYD : Assignment of System Data 1294 b0Output Port for SMDR D Apparatus When b 4 = 0 (IOC equipment No. 0) b 0 = Port 0 b1 = Port 1 b2 = Port 2 b3 = Port 3 When b 4 = 1 (IOC equipment No. 1) b 0 = Port 4 b1 = Port 5 b2 = Port 6 b3 = Port 7 “1” is to be assigned to each bit corresponding to the Port No. Note 1:Among the SMDR equipment that has the same IOC equipment number, double assignment of port is rejected. Note 2:The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as SMDR by AIOC. Note 3:This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not connected to the node, this data setting is fixed to “0”. b1 b2 b3 b4 b5Expanded SMDR for “D” apparatus. b6Not usedb7 295 b0Fault detection timer of SMDR D Value for the first digit (min): (0~9) Hex A~F Hex: Not usedTimer value ranges from 1 to 99 min- utes. 00 Hex: Without fault detection Normally, Assign 00 Hex. b1 b2 b3 b4Fault detection timer of SMDR D Value for the second digit (min): (0~9) Hex A~F Hex: Not used b5 b6 b7 296 00 Not used 303 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ~~~
CHAPTER 4 NDA-24298 Page 152 Issue 1 ASYD : Assignment of System Data 1304 b0 Individual Speed Calling Data Save 0/1 = Out/In Service (This data is valid when SYS1, INDEX 90, b 1 = 1) b1 Call Forwarding Data Save 0/1 = Out/In Service (This data is valid when SYS1, INDEX 90, b 1 = 1) b2PCS Data Save 0/1 = Out/In Service b3 Name Display Data Save 0/1 = Out/In Service (This data is valid when SYS1, INDEX 90, b 1 = 1) b4 User Assign Soft Key Data Save 0/1 = Out/In Service (This data is valid when SYS1, INDEX 90, b 1 = 1) b5 Number Sharing Data Save 0/1 = Out/In Service (This data is valid when SYS1, INDEX 90, b 1 = 1) b6 Call Block Data Save 0/1 = Out/In Service (This data is valid when SYS1, INDEX 90, b 1 = 1) 0 b7Not used 305 00 Not used 320 00 Not used 321 b0Inter-Module Group Key Data 0/1 = No/Yes b1Step Call While Transfer to Busy Station 0/1 = No/Yes b2Termination on My Line 0/1: Not Restricted/Restricted 0 b3 Not used 0b4 0b5 0b6 b7Voice Call Chime 0/1 = 4/1 Chime SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ~~~
NDA-24298 CHAPTER 4 Page 153 Issue 1 ASYD : Assignment of System Data 1322 b0Timing start to dial Attendant Console Assign digit used Note:When SYS-1, INDEX 92, b 0 = “0” (Individual SYS-2 Table Development), prepare separate SYS-2 Programming Sheets for each Tenant (TN).Note:Digits 0-9 are used with Index 17, b5b1 0b2 0b3 0b4Not used b5 Tone to be sent when the handset has been lifted via the Station on which CALL BLOCK service is set. 0/1 = DT/SPDT Note:Valid since the release 5 software. b6 Tone to be heard after the access code for Tone Block is dialed 0/1 = SPDT/DT Note:Valid since release 5 software. b7Call Return in case of station-to-station call 0/1 = Out/In Service 323 00 Not used 369 00 Not used 370 b0Expanded SMFN service 0/1 = No/Yes b1Delete ARNP RTO on MCI 0/1 = No/Yes b2Non-CCIS originated RT/TK number in SMDR 0/1 = No/Yes b3Att. outbound loop to loop 0/1 = No/Yes b4Release guard timer for S/L b5MTC = 0 × 15 milliseconds b6MTC × 64 milliseconds b7Default 384 milliseconds 371 00 Not used 387 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ~~~ ~~~
CHAPTER 4 NDA-24298 Page 154 Issue 1 ASYD : Assignment of System Data 13880 b0 - b3Not used b4 The way to answer the Internal Zone Paging call; 0 = Press the Prime Line key after Off-Hook 1 = Off-Hook Note:Valid for software Release 9 or later. 0 b5 - b7Not used 389 b0 - b4 Display Language on Dterm LCD Note 0: English 1: Portuguese 2: Spanish 3: French (For Release 9 software) 4-31: Not used Note:When assigning language, data “0” must be set in INDEX78, b4. 0 b5 - b7Not used 390 b0Caller ID display pattern on the LCD 0/1 = Calling Name/Calling Number has priority. b1Displayed information on the Top line of the LCD of the Dterm 0/1 = Caller ID/Call type or sub address b2 Display the Caller ID information on the Dterm that assigned the called number as a sub line. 0/1 = Out/In Service b3Display of Soft key to be pressed when the station is idle or is in DT connection. b4b3 00:blink 0 1 : steady-lights 1 0 : Displays the assigned code on 1st column (*1) 1 1 : No Indicationb4 b5Display of Soft key to be pressed when the station is in communication. b6b5 00:blink 01:– 1 0 : Displays the assigned code on 1st column (*1) 1 1 : No Indicationb6 0b7Not used 391Assign the first character to indicate the soft key in use. (See Ta b l e 4 - 2.) 392 - 438 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 155 Issue 1 ASYD : Assignment of System Data 1439 b0 - b6Not used b7 Station Hunting by call kind 0/1 = Invalid/Valid Note:Available for software Release 9 or later. 440-485 00 Not used 486 b0 ~ b2 Maximum number of transfer for Multiple Call Forwarding - CCIS occurrences b2b1b0b2b1b0 0 00=This service is invalid100=four times 0 01=once101=five times 0 10=twice110=six times 0 11=three times111=seven times Note:Valid when the node is “Call Forwarding-CCIS” start node. The number of call forwarding within a node is not counted. b3 ~ b7Not used 487 - 511 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 156 Issue 1 ASYD : Assignment of System Data Table 4-2 Assigned Code in 1st Column 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 A B C D E FA B C D E F * Upper 4bit Lower 4bit