NDA-24298 CHAPTER 4 Page 107 Issue 1 ASYD : Assignment of System Data 1126 b0External Equipment Alarm Timer (0-127): If external equipment continues to send alarm information for the duration over this timer value, the system will regard it as a failure. Example: b6b5b4b3b2b1b0 0 011110=30 sec. 1 111000=120 sec. b1 b2 b3 b4 b5 b6 b7 When MFC Public Exchange requests one more digit (GA-I): 0/1 = PBX sends GI-15 (end of digit) and waits a Backward Sig- nal/PBX waits a Backward Signal 127 00 Not used 128 b0Miscellaneous Timer counter (MTC) is to be assigned a value from 0 Hex to F Hex (0–15).The interval from the time a register is accessed until it re- ceives the first digit. Timer Value Setting is MTC × 2 sec. Note:When this data is 00 Hex, default data is automatically set to 12 sec. b1 b2 b3 0b4 Not used 0b5 0b6 0b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ORT SEIZURE DIAL PULSE “3”
CHAPTER 4 NDA-24298 Page 108 Issue 1 ASYD : Assignment of System Data 1129 b0Register Inter Digit Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).The interval between dialed digits. Timer Value Setting is MTC × 2 sec. Note:When this data is 00 Hex, default data is automatically set to 6 sec. b1 b2 b3 0b4 Not used 0b5 0b6 0b7 130 b0Sender Connection Acknowledgment Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).For calls over senderized Tie Lines, the sender requires an ACK signal from the distant PBX before it can send digits. This timer specifies how long the sender must wait. Timer Value Setting is MTC × 2 sec. Note:When this data is 00 Hex, default data is automatically set to 4 sec. b1 b2 b3 0b4 Not used 0b5 0b6 0b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ORT SEIZURE DIAL PULSE“3”“2” OGT START WINK SIGNAL
NDA-24298 CHAPTER 4 Page 109 Issue 1 ASYD : Assignment of System Data 11310 b0 Not usedFor 2nd DT trunks, the sender waits until this timer expires before sending dialed digits. Timer Value Setting is MTC × 512 msec. Note:When this data is 00 Hex, the following default data is automatically set: DP=2.9 sec. PB=2.5 sec. 0 b1 0b2 0b3 b4 Sender Prepause Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).b5 b6 b7 1320 b0 Not usedThe interval between dialed digits. Timer Value Setting is: 10 pps; MTC × 1 sec. 20 pps; MTC × 1 sec. Note:When this data is 00 Hex, 700 msec./10 pps and 450 msec./20 pps are automatically set. 0 b1 0b2 0b3 b4 Sender Inter Digit Timer for DP: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).b5 b6 b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT OGT START DIAL PULSE “3” OGT START“3”“2” SENDING DIAL PULSE
CHAPTER 4 NDA-24298 Page 110 Issue 1 ASYD : Assignment of System Data 11330 b0 Not usedThe interval between dialed digits Timer Value Setting is 60 msec./120 msec. + MTC × 512 msec. Note 1:When this data is 00 Hex, timer value is 60 msec/120 msec. Note 2:60/120 msec. is decided by parameter ONSG of the ARTD command. 0 b1 0b2 0b3 b4 Sender Inter Digit Timer for PB: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).b5 b6 b7 134 b0ATT Sender Release Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).After connection to 2nd DT trunk. If this timer expires before the sender receives an answer from the 2nd DT trunk, the ATT display changes to RT/TRK and the sender is released (false answer). Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 4 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=– b5 b6 0b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 2 3 OGT START SENDING PB SIGNAL
NDA-24298 CHAPTER 4 Page 111 Issue 1 ASYD : Assignment of System Data 1135 b0Seizure Guard Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).After a trunk is seized, it cannot be dialed until this timer expires. This timer prevents bypassing of Toll Restriction. Timer Value Setting is MTC × TC msec. Note:When this data is 00 Hex, default data is automatically set to 1 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=64 sec. 101=– 0 10=–110=– 0 11=–111=– b5 b6 0b7Not used 136 b0Ground Button on Hold Timer for Special Common Battery Telephone: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).When a station with a ground button goes off-hook and depresses the button for the interval specified by this timer, the PBX recognizes it as being off-hook. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 4 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=– b5 b6 0b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 112 Issue 1 ASYD : Assignment of System Data 1137 b0Start Timer for Periodic Indication Tone: Miscellaneous Timer Counter (MTC) is assigned a value from 0 Hex to F Hex (0-15).This timer specifies the point in a conversation at which the first Periodic Indication Tone is to be sent. This timer is only valid for routes that have been assigned Periodic Indication Tone service via parameter TELP (CDN 29) of command ARTD. Timer Value Setting is MTC + 1 × TC. Note:When this data is 00 Hex, default data is automatically set to 3 min (±30 sec.). b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 000=–100=30 sec. 001=64 msec101=– 010=–110=– 011=2 sec. 111=– b5 b6 0b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT CALL WARNING TONESTART INDEX–138 INDEX –137
NDA-24298 CHAPTER 4 Page 113 Issue 1 ASYD : Assignment of System Data 1138 b0Periodic Indication Tone Interval Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).This timer assigns the interval between Periodic Indication Tones, after the first tone has been sent. Timer Value Setting is MTC + 1 × TC. Note:When this data is 00 Hex, default data is automatically set to 3 min (±30 sec.). b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 000=–100=30 sec. 001=64 msec101=– 010=–110=– 011=2 sec. 111=– b5 b6 0b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 114 Issue 1 ASYD : Assignment of System Data 1139 b0No Answer Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).No Answer Timer for Station to Station, DID, and Tie Line calls. This timer applies to C.F.-Don’t Answer, Call Back, and Call Hold. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=8 sec. b5 b6 0b7Not used 140 b0No Answer Timer for Recall on Call Transfer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).The duration for which a call will ring at the transfer destination before it will recall to the transferring party. The timer value is effective when INDEX 69, b 0 = “0”. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=8 sec. b5 b6 0b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 115 Issue 1 ASYD : Assignment of System Data 1141 b0No Answer Timer for Station Call from AT T : Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).This timer applies to stations for which C.F.-Don’t Answer has been set. This timer assigns the duration for which calls being transferred by the attendant will ring at the station before being forwarded. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 10 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=8 sec. b5 b6 0b7Not used 142 b0Automatic Recall Timer for Call Park service: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 450 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec111=8 sec. b5 b6 0b7Not used 143 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 116 Issue 1 ASYD : Assignment of System Data 1144 b0Automatic Hold Recall Timer for Dterm: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).This timer is used for Exclusive Hold and Non-Exclusive Hold. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=8 sec. 0 11=2 sec.111=– b5 b6 0b7Not used This timer assigns the duration for which a call being transferred to a station from the attendant will ring at the station before being recalled. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 32 sec. 145 b0Attendant Console Automatic Recall Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15). b1 b2 b3 1b4Timer Class (TC) must be assigned as “001” TC = 001 means 8 sec. 0 b5 0b6 b7 Attendant Console Automatic Recall Timer Va l u e 0/1 = Ineffective/Effective SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT