    ASYD : Assignment of System Data
    1126
    b0External Equipment Alarm Timer (0-127):
    If external equipment continues to send alarm information for the 
    duration over this timer value, the system will regard it as a failure.
    Example:
    b6b5b4b3b2b1b0
    0 011110=30 sec.
    1 111000=120 sec.
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    When MFC Public Exchange requests one more digit (GA-I):
    0/1 = PBX sends GI-15 (end of digit) and waits a Backward Sig-
    nal/PBX waits a Backward Signal
    127 00
    Not used
    128
    b0Miscellaneous Timer counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex
    (0–15).The interval from 
    the time a register is 
    accessed until it re-
    ceives the first digit.
    Timer Value Setting 
    is MTC 
    × 2 sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 12 sec.
    b1
    b2
    b3
    0b4
    Not used 0b5
    0b6
    0b7
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ORT SEIZURE
    DIAL PULSE
    “3” 
    						
    							CHAPTER 4 NDA-24298
    Page 108
    Issue 1
    ASYD : Assignment of System Data
    1129
    b0Register Inter Digit Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).The interval 
    between dialed 
    digits.
    Timer Value Setting 
    is MTC
     × 2 sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 6 sec.
    b1
    b2
    b3
    0b4
    Not used 0b5
    0b6
    0b7
    130
    b0Sender Connection Acknowledgment 
    Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).For calls over 
    senderized Tie 
    Lines, the sender 
    requires an ACK 
    signal from the 
    distant PBX before 
    it can send digits. 
    This timer specifies 
    how long the sender 
    must wait.
    Timer Value Setting 
    is MTC 
    × 2 sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 4 sec.
    b1
    b2
    b3
    0b4
    Not used 0b5
    0b6
    0b7
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ORT SEIZURE
    DIAL PULSE“3”“2”
    OGT START
    WINK SIGNAL 
    						
    							NDA-24298 CHAPTER 4
    Page 109
    Issue 1
    ASYD : Assignment of System Data
    11310
    b0
    Not usedFor 2nd DT trunks, 
    the sender waits 
    until this timer 
    expires before 
    sending dialed 
    digits.
    Timer Value Setting 
    is MTC 
    × 512 msec.
    Note:When this 
    data is 00 
    Hex, the 
    following 
    default data is 
    automatically 
    set:
    DP=2.9 sec.
    PB=2.5 sec. 0
    b1
    0b2
    0b3
    b4
    Sender Prepause Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).b5
    b6
    b7
    1320
    b0
    Not usedThe interval 
    between dialed 
    digits.
    Timer Value Setting 
    is:
    10 pps; MTC 
    × 1 
    sec.
    20 pps; MTC 
    × 1 
    sec.
    Note:When this 
    data is 00 
    Hex, 700 
    msec./10 pps 
    and 450 
    msec./20 pps 
    are 
    automatically 
    set. 0
    b1
    0b2
    0b3
    b4
    Sender Inter Digit Timer for DP:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).b5
    b6
    b7
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    OGT START
    DIAL PULSE
    “3”
    OGT START“3”“2”
    SENDING
    DIAL PULSE 
    						
    							CHAPTER 4 NDA-24298
    Page 110
    Issue 1
    ASYD : Assignment of System Data
    11330
    b0
    Not usedThe interval 
    between dialed 
    digits
    Timer Value Setting 
    is 60 msec./120 
    msec. + MTC 
    × 512 
    msec.
    Note 1:When this 
    data is 00 
    Hex, timer 
    value is 60 
    msec/120 
    msec.
    Note 2:60/120 
    msec. is 
    decided by 
    parameter 
    ONSG of 
    the ARTD 
    command. 0
    b1
    0b2
    0b3
    b4
    Sender Inter Digit Timer for PB:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).b5
    b6
    b7
    134
    b0ATT Sender Release Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).After connection to 
    2nd DT trunk. If this 
    timer expires before 
    the sender receives 
    an answer from the 
    2nd DT trunk, the 
    ATT display 
    changes to RT/TRK 
    and the sender is 
    released (false 
    answer).
    Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 4 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=–
    b5
    b6
    0b7Not used
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    2 3
    OGT START
    SENDING PB SIGNAL 
    						
    							NDA-24298 CHAPTER 4
    Page 111
    Issue 1
    ASYD : Assignment of System Data
    1135
    b0Seizure Guard Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).After a trunk is 
    seized, it cannot be 
    dialed until this 
    timer expires. This 
    timer prevents 
    bypassing of Toll 
    Restriction.
    Timer Value Setting 
    is MTC 
    × TC msec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 1 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=64 sec. 101=–
    0 10=–110=–
    0 11=–111=–
    b5
    b6
    0b7Not used
    136
    b0Ground Button on Hold Timer for Special 
    Common Battery Telephone:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).When a station with 
    a ground button goes 
    off-hook and 
    depresses the button 
    for the interval 
    specified by this 
    timer, the PBX 
    recognizes it as 
    being off-hook.
    Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 4 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=–
    b5
    b6
    0b7Not used
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 112
    Issue 1
    ASYD : Assignment of System Data
    1137
    b0Start Timer for Periodic Indication Tone:
    Miscellaneous Timer Counter (MTC) is 
    assigned a value from 0 Hex to F Hex 
    (0-15).This timer specifies 
    the point in a 
    conversation at 
    which the first 
    Periodic Indication 
    Tone is to be sent. 
    This timer is only 
    valid for routes that 
    have been assigned 
    Periodic Indication 
    Tone service via 
    parameter TELP 
    (CDN 29) of 
    command ARTD.
    Timer Value Setting 
    is MTC + 1 
    × TC.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 3 min 
    (±30 sec.).
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    000=–100=30 sec.
    001=64 msec101=–
    010=–110=–
    011=2 sec. 111=–
    b5
    b6
    0b7Not used
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    CALL
    WARNING TONESTART
    INDEX–138 INDEX
    –137 
    						
    							NDA-24298 CHAPTER 4
    Page 113
    Issue 1
    ASYD : Assignment of System Data
    1138
    b0Periodic Indication Tone Interval Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).This timer assigns 
    the interval between 
    Periodic Indication 
    Tones, after the first 
    tone has been sent.
    Timer Value Setting 
    is MTC 
    + 1 × TC.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 3 min 
    (±30 sec.).
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    000=–100=30 sec.
    001=64 msec101=–
    010=–110=–
    011=2 sec. 111=–
    b5
    b6
    0b7Not used
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 114
    Issue 1
    ASYD : Assignment of System Data
    1139
    b0No Answer Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).No Answer Timer 
    for Station to 
    Station, DID, and 
    Tie Line calls.
    This timer applies to 
    C.F.-Don’t Answer, 
    Call Back, and Call 
    Hold.
    Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 30 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=8 sec.
    b5
    b6
    0b7Not used
    140
    b0No Answer Timer for Recall on Call 
    Transfer: 
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).The duration for 
    which a call will 
    ring at the transfer 
    destination before it 
    will recall to the 
    transferring party. 
    The timer value is 
    effective when 
    INDEX 69, b
    0 = “0”.
    Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 30 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=8 sec.
    b5
    b6
    0b7Not used
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 115
    Issue 1
    ASYD : Assignment of System Data
    1141
    b0No Answer Timer for Station Call from 
    AT T :
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).This timer applies to 
    stations for which 
    C.F.-Don’t Answer 
    has been set. This 
    timer assigns the 
    duration for which 
    calls being 
    transferred by the 
    attendant will ring at 
    the station before 
    being forwarded. 
    Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 10 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=8 sec.
    b5
    b6
    0b7Not used
    142
    b0Automatic Recall Timer for Call Park 
    service:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 450 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec111=8 sec.
    b5
    b6
    0b7Not used
    143 00
    Not used
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 116
    Issue 1
    ASYD : Assignment of System Data
    1144
    b0Automatic Hold Recall Timer for Dterm:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).This timer is used 
    for Exclusive Hold 
    and Non-Exclusive 
    Hold. Timer Value 
    Setting is MTC 
    × 
    TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 30 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of 
    the following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=8 sec.
    0 11=2 sec.111=–
    b5
    b6
    0b7Not used This timer assigns 
    the duration for 
    which a call being 
    transferred to a 
    station from the 
    attendant will ring at 
    the station before 
    being recalled.
    Timer Value Setting 
    is MTC 
    × TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is 
    automatically 
    set to 32 sec. 145
    b0Attendant Console Automatic Recall 
    Timer:
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0-15).
    b1
    b2
    b3
    1b4Timer Class (TC) must be assigned as 
    “001”
    TC = 001 means 8 sec. 0
    b5
    0b6
    b7
    Attendant Console Automatic Recall Timer 
    Va l u e
    0/1 = Ineffective/Effective
    SYSTEM 
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						