    							NDA-24298 CHAPTER 4
    Page 797
    Issue 1
    AARS : Assignment of Alternative Route Service Restriction
    AARS: Assignment of Alternative Route Service Restriction
    1. General
    This command assigns various service connections between the outgoing route and the incoming route when
    they are to be restricted, or to assign the existing restrictions when such service connections are to be canceled.
    2. Precautions
    If the data is not assigned, the specified connections are to be restricted.
    3. Data Entry Instructions
    INCOMING ROUTE
     NUMBER (ICRT)OUTGOING ROUTE
            NUMBER
             (OGRT)RESTRICTION
      DATA (RES)
             0-2ROUTE SERVICE
              (RSV)
                0/1REMARKS
    120
    0
     RSVRES
     0 = Not used              1 = AMP Pool  When RSV = 1 (AMP Pool)
       0 = Restriction                    1 = OGT
       2 = ICT 
    						
    							CHAPTER 4 NDA-24298
    Page 798
    Issue 1
    AARS : Assignment of Alternative Route Service Restriction
    4. Data Sheet
    INCOMING
    ROUTE
     NUMBER
    (ICRT)OUTGOING ROUTE
     NUMBER 
    (OGRT)ROUTE SERVICE
     (RSV)
    0/1RESTRICTION DATA
     (RES)
     0 – 2REMARKS 
    						
    							NDA-24298 CHAPTER 4
    Page 799
    Issue 1
    AARSN : Assignment of Alternative Route Service Restriction for NDM
    AARSN: Assignment of Alternative Route Service Restriction for NDM
    1. General
    This command assigns various service connections between the outgoing route and the incoming route when
    they are to be restricted, or to assign the existing restrictions when such service connections are to be canceled.
    The data assigned by this command is written in the Network Data Memory (NDM) of the Network Control
    Node (NCN), updating the NDM at each Local Node (LN).
    2. Precautions
    1. This command can be used only when logging in to NCN.
    2. If the data is not assigned, the specified connections are to be restricted.
    3. Data Entry Instructions
    INCOMING
    LOGICAL 
    ROUTE 
    NUMBER
    (IC_LGRT)
    1-899OUTGOING
    LOGICAL 
    ROUTE 
    NUMBER
    (OG_LGRT)
    1-899
    ROUTE
    SERVICE
    (RSV)
    0/1RESTRICTION
    DATA
    (RES)
    0-2
    RES
    When RSV = 1 (AMP Pool)
    0 = Restriction
    1 = OGT
    2 = ICT
    RSV
    0 = Not used
    1 = AMP Pool
    REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 800
    Issue 1
    AARSN : Assignment of Alternative Route Service Restriction for NDM
    4. Data Sheet
    INCOMING LOGICAL
    ROUTE NUMBER
    (IC_LGRT)
    1-899OUTGOING LOGICAL
    ROUTE NUMBER
    (OG-LGRT)
    1-899ROUTE SERVICE
    (RSV)
    0/1RESTRICTION
    DATA
    (RES)
    0-2REMARKS 
    						
    							NDA-24298 CHAPTER 4
    Page 801
    Issue 1
    ALPE: Assignment of Line Privacy Expansion Data
    ALPE:Assignment of Line Privacy Expansion Data
    1. General
    This command assigns the eight-party Conference Trunk (CFT card), which is seized in Line Privacy Expansion
    Service on a per-tenant basis.
    2. Precautions
    1. Enter the data “1” at the TN parameter when “1” is entered at the TNF parameter.
    2. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.
    3. The Station Number entered in the STN parameter must correspond to the one assigned at the first circuit
    (No. 0 circuit) of the CFT card.
    3. Data Entry Instructions
    TENANT FLAG
           (TNF)
             0/1TENANT NUMBER
                (TN)
       STATION NUMBER
               (STN)REMARKS
    11311
    2
    TNF
    0 = Separate
    1 = Common 
    						
    							CHAPTER 4 NDA-24298
    Page 802
    Issue 1
    ALPE: Assignment of Line Privacy Expansion Data
    4. Data Sheet
    TENANT FLAG
    (TNF)
    0/1TENANT 
    NUMBER
     (TN)STATION NUMBER 
    (STN)
    MAX. 6 DIGITSREMARKS 
    						
    							NDA-24298 CHAPTER 4
    Page 803
    Issue 1
    ARPC : Assignment of Remote Point Code for Centralized Service
    ARPC: Assignment of Remote Point Code for Centralized Service
    1. General
    This command assigns the data related to the Message Center Interface - CCIS service feature. 
    2. Precautions
    1. This command is used only at the main office of the Message Center Interface - CCIS service feature.
    2. The MCI is installed at the main office of the CCIS network, and the MCI text is transmitted (or received)
    to (from) the external VMS when an event treated by the MCI service feature has occurred at the satellite
    office.
    3. Data Entry Instructions
    REMOTE POINT CODE COUNTER                    (CNT) 
                         1-32CENTRALIZED SERVICE NUMBER
                             (CSN)
                                1-7REMOTE POINT CODE
                   (RPC)
                 1-16383REMARKS
    11
    2
    3
    CSN
    RPC
    1 = Message Center
    2-7 = Not usedEnter the PC of the satellite office.
          
    						
    							CHAPTER 4 NDA-24298
    Page 804
    Issue 1
    ARPC : Assignment of Remote Point Code for Centralized Service
    4. Data Sheet
    CENTRALIZED SERVICE 
    NUMBER
    (CSN)
    1-7REMOTE POINT CODE 
    COUNTER 
    (CNT)
    1-32REMOTE POINT CODE
    (RPC)
    1-16383REMARKS
    11
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32 
    						
    							NDA-24298 CHAPTER 4
    Page 805
    Issue 1
    ARDN : Assignment of Remote Control Day/Night
    ARDN: Assignment of Remote Control Day/Night 
    1. General
    This command assigns the data related to the Centralized Day/Night Mode Change service feature.
    2. Precautions
    1. This command is used only at the Main office which controls the Day/Night mode for the satellite office
    via the CCIS link. 
    2. When there are multiple satellite offices created by grouping tenant numbers, the mode can be changed on
    all the satellite offices or on a per tenant basis.
    3.  For the Main office, the related indexes of the ASYD command are as follows:
    SYS1, INDEX18, bit6 (Day/Night change of satellite office) 0/1 = Out/In service 
    SYS1, INDEX75, bit0 (ARSC command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit1 (ASFC command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit2 (ATNR command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit3 (ATDP command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit4 (AEFR command Day/Night table) 0/1 = common/separate
     For the Satellite office, the related indexes of the ASYD command are as follows:
    SYS1, INDEX18, bit7 (Day/Night change is executed by the Main Office) 0/1 = Out/In service
    SYS1, INDEX19, bit0-3 (Tenant (TN=1-15) of the main office to which the satellite office belongs)
    SYS1, INDEX75, bit0 (ARSC command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit1 (ASFC command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit2 (ATNR command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit3 (ATDP command Day/Night table) 0/1 = common/separate
    SYS1, INDEX75, bit4 (AEFR command Day/Night table) 0/1 = common/separate 
    						
    							CHAPTER 4 NDA-24298
    Page 806
    Issue 1
    ARDN : Assignment of Remote Control Day/Night
    3. Data Entry Instructions
    4. Data Sheet
    POINT CODE INDEX
     (INDEX)
    0 – 15POINT CODE 
    (PC)
    1 – 16383REMARKS
    0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    POINT CODE INDEX
              (INDEX)
                 0-15POINT CODE
            (PC)
        1-16383REMARKS
    INDEX
    Enter an arbitrary unique number within
    the range from 0 to 15.PC
    Enter the PC of satellite office. 
    						