    							NDA-24298 CHAPTER 4
    Page 197
    Issue 1
    AIOC : Assignment of IOC Port Data
    CHARACTER BIT0=8bits
    1=7bitsBUSY SIGNAL0=(+)1=(-)
    SYNC CHARACTER 0=Bi-sync
    1=Mono-sync
    PB SIGNAL
    0=No PB signal
    1=PB signal is required
    ENH
    (Extended block parameter)
    0=Invalid  Note
    1=Valid (Continue to following attribution data assignment.)
    Note: Standard data is 0.
    SYNC0=ST1
    1=ST2
    (SPEED)
    0-6 (PROTOCOL)
    0-2(PARITY BIT)
    0-3(STOP BIT)
    0-3(SYNC)
    0/1(CHARACTER 
    BIT) 0/1(SYNC CHAR-
    ACTER) 0/1(BUSY SIGNAL)
     0/1
    SPEED0=Default(4800bps)
    1=300bps
    3=1200bps
    5=4800bps2=600bps
    4=2400bps
    6=9600bps
    PARITY BIT0=Non Parity
    1=Odd Parity
    2=Even Parity
    3=Non Parity
    STOP BIT
    0=2bits
    1=1bit
    2=1+1/2bits
    3=2bits
    TERMINAL=7 (PMS) / 8 (Hotel Printer)
    PROTOCOL0=Free Wheeling
    1=BSC Pooling
    2=BSC Contention
    3=Level 2A
    4=Level 2B
    (ENH)
    0/1 (PB SIGNAL)
    0/1
    WR
    (Transmission method)
    0 Fixed. (RS ON always)
    ET
    (EOT on reset)
    0=Invalid
    1=Valid
    (PM)
    0/1 (CLASS)
    0-3(CN)
    0-3(FL)
    0/1(ET)
    0/1(KJ)
     0/1(WR) (DR)
     0/1
    PM
    (Priority Point specification)
    0=First Priority Point
    1=Second Priority Point
    CN
    (Continuous
    Transmission)
    0=Invalid
    1=Valid
    FL
    (Reception
    buffer shortage)
    0=NAK
    1=WABT
    KJ
    (Kanji Character code)
    0=Invalid
    1=Valid
    DR
    (DR signal disregard)
    0=Invalid
    1=Valid
    Following optional parameters appear when ENH (Extended block parameter) = 1.
    CLASS0=-CR/LF
    1=-CR
    2=STX-ETX
    3=STX-ETX/BCC 
    						
    							CHAPTER 4 NDA-24298
    Page 198
    Issue 1
    AIOC : Assignment of IOC Port Data
    Example: Standard data for PMS and Hotel printer.
    PMS (Level 2A): PROTOCOL = 3 (Level 2A)
    SPEED = 3 (1200bps)
    PARITY BIT = 2 (Even Parity)
    STOP BIT = 0 (2bits)
    SYNC = 0 (Not used)
    CHARACTER BIT = 0 (8bits)
    SYNC CHARACTER = 0 (Not used)
    BUSY SIGNAL = 0 (Not used)
    PB SIGNAL = 0 (No PB signal)
    ENH = 0 (Invalid)
    Hotel Printer: PROTOCOL = 0 (Free Wheeling)
    SPEED = 3 (1200bps)
    PARITY BIT = 0 (No Parity)
    STOP BIT = 0 (2bits)
    CHARACTER BIT = 0 (8bits)
    Others = 0 (Not used)
    (XO)
    0/1 (CD)
    0/1(SN)
    0/1(SA)
    20-7E Hex.(TUA)
    20-7E Hex.(RUA)
     20-7E Hex.
    X0
    (X-ON / OFF Control)
    0=Invalid
    1=Valid
    SN
    (Transmission address 
    number control)
    0=Invalid
    1=Valid
    CD
    (CD Signal disregard)
    0=Invalid
    1=Valid
    SA
    (Station address)
    20 Hex. - 7E Hex.
    RUA
    (Unit address for reception)
    20 Hex. - 7E Hex.
    TUA
    (Unit address for transmission)
    20 Hex. - 7E Hex. 
    						
    							NDA-24298 CHAPTER 4
    Page 199
    Issue 1
    AIOC : Assignment of IOC Port Data
    4. Data Sheet
    (a) TERMINAL=1 (Printer/MCI)
    (b) TERMINAL=2 (MAT)
    (c) TERMINAL=3 (CMAT)
    IOC PORT 
    NUMBER 
    (IOC)TERMINAL KIND 
    (TERMINAL)
    1
    (SPEED) (PARITY BIT) (STOP BIT) (CHARACTER BIT) REMARKS
    IOC PORT 
    NUMBER 
    (IOC)TERMINAL KIND 
    (TERMINAL)
    2
    (SYMSCAN) (SPEED) (MTYPE) REMARKS
    IOC PORT 
    NUMBER 
    (IOC)TERMINAL KIND 
    (TERMINAL)
    3
    (SYMSCAN) (SPEED) (MTYPE) REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 200
    Issue 1
    AIOC : Assignment of IOC Port Data
    (d) TERMINAL=4 (SMDR FREE WHEELING)
    (e) TERMINAL=5 (SMDR BSC)
    (f) TERMINAL=6 (ATM Module)
    IOC PORT 
    NUMBER 
    (IOC)TERMINAL KIND 
    (TERMINAL)
    4
    (PROTOCOL) (SPEED) (PARITY BIT) (STOP BIT) (CHARACTER BIT)
    00 0
    IOC PORT 
    NUMBER 
    (IOC)TERMINAL
    KIND
    (TERMINAL)
    5
    (PROTOCOL) (SPEED)(PARITY 
    BIT)(STOP 
    BIT)(SYNC) (CHARACTER BIT)(SYNC 
    CHARACTER)(BUSY 
    SIGNAL)
    IOC PORT 
    NUMBER 
    (IOC)TERMINAL KIND 
    (TERMINAL)
    6
    (SPEED) (PARITY BIT) (STOP BIT) (CHARACTER BIT) (ATM) 
    						
    							NDA-24298 CHAPTER 4
    Page 201
    Issue 1
    AIOC : Assignment of IOC Port Data
    (g) TERMINAL=7 (PMS)
    When ENH=1 (Option),
    IOC
    PORT NUMBER 
    (IOC)TERMINAL
    KIND
    (TERMINAL)
    7
    (PROTOCOL) (SPEED) (PARITY BIT) (STOP BIT) (SYNC) (CHARACTER BIT)(SYNC 
    CHARACTER)(BUSY 
    SIGNAL)
    (PB SIGNAL)
    0/1(ENH)
    0/1
    (CLASS)
    0-3(PM)
    0/1(CN)
    0-3(FL)
    0/1(ET)
    0/1(KJ)
    0/1(WR) (DR)
    0/1
    (CD)
    0/1(XO)
    0/1(SN)
    0/1(SA)
    20-7E Hex.(TUA)
    20-7E Hex.(RUA)
    20-7E Hex. 
    						
    							CHAPTER 4 NDA-24298
    Page 202
    Issue 1
    AIOC : Assignment of IOC Port Data
    (h) TERMINAL=8 (Hotel Printer)
    IOC
    PORT NUMBER 
    (IOC)TERMINAL
    KIND
    (TERMINAL)
    10
    (PROTOCOL) (SPEED) (PARITY BIT) (STOP BIT) (SYNC) (CHARACTER BIT)(SYNC 
    CHARACTER)(BUSY 
    SIGNAL)
    (PB SIGNAL)
    0/1(ENH)
    0/1 
    						
    							NDA-24298 CHAPTER 4
    Page 203
    Issue 1
    ASTD : Assignment of State Translation Data
    ASTD:  Assignment of State Translation Data
    1. General
    This command translates the system attributes.
    2. Precautions
    One STM contains multiple numbers of STS(s), and the combination of the STM”n” and STS”n” has one kind
    of (or multiple kinds of) purpose(s) to be designated. The data zero (0) or one (1) assigned in ST designates how
    the system works. See Table 4-3 for Assignment of ASTD.
    3. Data Assignment Instructions
    See Table 4-3.
    Table 4-3 List for Assignment of ASTD
    STM STSST
    * = standard settings
    00Processing at the time of originating an outgoing 
    C.O. line call0If the calling station is that of RSC = 1, 3, the call 
    is outgoing via LCR
    1* The call is processed by second dial tone system.
    Processing for an override from a station into a 
    connection between COT and another station0 Override not allowed
    1* Override allowed
    Passing dial tone0 Invalid
    1* Valid
    Processing for warning tone sending at the 
    moment when ATT has overridden into a 
    connection between COT and a station (Busy 
    Verification)0Warning tone is sent out to both the ATT and the 
    station.
    1*Warning tone is sent out to both the station, ATT, 
    and C.O. side.
    Processing for a warning tone sending at the 
    moment when ATT has overridden into busy 
    COT (Attendant Override)0 Warning tone is not sent out the C.O. side.
    1* Warning tone is also sent out to the C.O. side.
    1Kind of trunk to be seized for an outgoing C.O. 
    line call from ATT0BWT only
    1* Either BWT or OGT as the case may be
    2 Tandem connection with COT included0 Restricted
    1* Allowed (depending on ARRC)
    3 Enable Passing Dial Tone 0*
    4 Busy Verification Tone for Att. and Sta. only 0* 
    						
    							CHAPTER 4 NDA-24298
    Page 204
    Issue 1
    ASTD : Assignment of State Translation Data
    10 Trunk Release0 Station (Calling Party Release)
    1 Trunk  Note 1
    1
    2
    3
    4
    * = standard settings
    Note 2:One setting applies to five items. (STM=0, STS 0)
    20 Three-way calling with COT included0 Restricted
    1* Allowed
    1Three-way calling with COT included in Execu-
    tive Right of Way service0 Restricted
    1* Allowed
    2Outgoing call to a C.O. Line or a Tie Line after 
    holding the COT0 Restricted
    1* Allowed
    3Outgoing call to a C.O. Line after holding a sta-
    tion or a Tie Line0 Restricted
    1* Allowed
    4Processing for calling a fully-restricted station 
    after holding the COT0 Restricted
    1*Allowed
    Note:The call can be transferred.
    5Processing in which ATT overrides to the con-
    nection between the COT and a station (Busy 
    Verification) and then the Busy Verification 
    Warning Tone is sent out periodically0*Warning tone is sent out to both the station and 
    the ATT
    1Warning tone is sent out to the station, ATT, and 
    C.O. side.
    6Step call when a Tie Line incoming call encoun-
    ters busy0Allowed
    1 Restricted
    4 0 Remote Access to PBX/Automated Attendant0 Not provided
    1* In service
    60 DAY/NIGHT mode changeover system0 Not used.
    1* Fixed to “1”.
    10*
    20*
    30*
    Note 1:
    Valid when C.O. line has a release signal.
    (Standard Setting is “1”.)
    Table 4-3 List for Assignment of ASTD (Continued)
    STM STSST
    * = standard settings 
    						
    							NDA-24298 CHAPTER 4
    Page 205
    Issue 1
    ASTD : Assignment of State Translation Data
    4. Data Assignment Sheet
    STATE TRANSLATION
    MAIN CATEGORY NUMBER
    (STM)
    0 - 31STATE TRANSLATION
    CATEGORY NUMBER
    (STS)
    0 - 31STATE TRANSLATION
    INFORMATION
    (ST)
    0/1REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 206
    Issue 1
    AOFC : Assignment of Office Name
    AOFC:  Assignment of Office Name
    1. General
    This command assigns the office name.
    2. Precautions
    1. The data assignment of this command is the same as the ASYD command SYS1, INDEX96 through 115.
    2. The office name is also included in the dump files of LIST UP, Traffic Measurement, and System
    Message.
    3. Data Entry Instructions
    Maximum 20 characters of office name.OFFICE NAME
    MAXIMUM 20 CHARACTERS(OFFICE NAME)
    REMARKS 
    						