NDA-24298 CHAPTER 4 Page 157 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 20 b0Restriction Data of Station Busy Services can be designated as in the table below: R: RestrictedA: Allowed b1 0b2Not used b3Attendant Override service 0/1 = Out/In Service b4Busy Verification for Attendant Console service 0/1 = Out/In Service 0 b5 Not used 0b6 0b7 SYSTEM TN IPX 1 ~ 63 b1b0Call BackExecutive Right of WayCall Waiting- OriginatingVo i c e call (D term)Message Reminder (Dterm) 00 R R R R R 01 A R A A A 10 R A A A A 11 A A A A A
CHAPTER 4 NDA-24298 Page 158 Issue 1 ASYD : Assignment of System Data Note:b 0, b1, and b7 designate the type of sender signal for outgoing calls placed over routes programmed as “DP/PB” via parameter ONSG (CDN: 2) of command ARTD (Route Class Data). SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FFBIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 21 b0Call Transfer service b1b0 0 0 = Out of service 0 1 = In service - except Tandem Connection 1 0 = In service - only Terminating calls 11=In serviceb1 0b2Not used b3Toll Restriction for Speed Calling Station/Group services 0/1 = Required/Not Required b4Toll Restriction (disposition of Restricted Call) b5b4 0 0=Toll Denial (ROT connection) 0 1=Toll Diversion (Terminated to Attendant Console) 10=– 11=– b5 b6Speed Calling Override Service via (AABD) 0/1 = Out/In Service b7Speed Calling Override Service (System basis) 0/1 = Follow RSC of Phone/Allowed 2 b0S end er Sig n al to DP /PB R ou te (St ation ) Note 0/1 = DP/PB b1Sender Signal to DP/PB Route (Attendant Console) Note 0/1 = DP/PB b2Attendant Console Day/Night Mode Change b3b2 0 0 = Not Required (External Switch effective) 0 1 = Master Attendant Console 1 0 = All Attendant Consoles 11=– b3 0b4Not used b5Attendant Loop Release service 0/1 = Out/In Service 0 b6Not used b7Kind of DP sender (when b0 = 0) Note 0/1 = 10 PPS/20 PPS SYSTEM TN IPX 1 ~ 63
NDA-24298 CHAPTER 4 Page 159 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 23 b0SMDR service 0/1 = Out/In Service 0 b1 Not used 0b2 0b3 b4Account Code when Authorization Code is in service 0/1 = Not Required/Required b5Code type 0/1 = Authorization Code/Forced Account Code 0 b6Not used b7Output of SMDR Station-to-Station Connection Data 0/1 = Not Required/Required SYSTEM TN IPX 1 ~ 63
CHAPTER 4 NDA-24298 Page 160 Issue 1 ASYD : Assignment of System Data Note: When data “1” is assigned, either SID = 3 or 19 may be assigned via command ASPA. SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 0 - 63SYSTEM DATA INDEX (INDEX)DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 24 b0Call Back and OG Trunk Queuing Access Code Note 0/1 = Separate/Common b1 Automatic setting of OG Trunk Queuing service Note When receiving BT, OG Trunk Queuing is set automatically by going on-hook. 0/1 = Not Required/Required b2Off-Hook Queuing service for Attendant Console 0/1 = Out/In Service 0 b3 Not used 0 b4 0b5 0b6 0b7 50 b0, b1Not used b2 When the destination station is busy, Call Back is automatically set after the operating station is released from the connection in Call Transfer - All Calls procedure. 0 = Recall to the mediate station 1 = Camp On Service is set Note:Available for software Release 9 or later. 0 b3 - b7Not used SYSTEM TN IPX 1 ~ 63
NDA-24298 CHAPTER 4 Page 161 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 -15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 26 b0 Message Center Interface service when terminating to a UCD Group 0/1 = Out/In Service 0 b1 Not used 0b2 0b3 b4 Call Origination Restriction of Station upon Setting C.F.- All Calls 0/1 = Required/Not Required b5Inter-Position Transfer service 0/1 = Out/In Service 0 b6Not used b7 C.F.-Don’t Answer service when Attendant Console transfers call before called station answers 0/1 = Out Service (Recall to Attendant Console)/In Service SYSTEM TN IPX 1 ~ 63
CHAPTER 4 NDA-24298 Page 162 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX)DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 27 b0Busy Lamp Field-Flexible service 0/1 = Out/In Service b1 Message Center Interface service when terminating Attendant Console 0/1 = Out/In Service b2Serial Call service 0/1 = Out/In Service b3Supervisory Call service 0/1 = Out/In Service b4 First Digit of Phantom Station Number for Privacy Expansionb5 b6 b7 SYSTEM TN IPX 1 ~ 63
NDA-24298 CHAPTER 4 Page 163 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA (INDEX) INDEX 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 28 b0Listed Directory Number (LDN) 0/1 = Exclude/Include Waiting Call Display (Attendant Console) 0/1 = Exclude/Include Note 1:When an Attendant Console is shared by multiple tenants, Waiting calls are displayed according to the SYS-2 data (INDEXES 8, 9) of the Tenant – accesses the Attendant Console first. (Refer to command ATRK). Note 2:When FCCS Service is applied to the system, the common SYS-2 data (INDEX 8, 9) must be assigned to all the Nodes. b1Operator Call (ATND) 0/1 = Exclude/Include b2Attendant Recall (RCL) 0/1 = Exclude/Include b3 Not usedb4 b5 b6Tie Line (TIE) 0/1 = Exclude/Include b7Call Forwarding-Busy Line (BUSY) 0/1 = Exclude/Include 9 b0 Call Forwarding – Don’t Answer (NANS) 0/1 = Exclude/Include b1Call Forwarding-Intercept (ICPT) 0/1 = Exclude/Include b2Interposition Transfer (TF) 0/1 = Exclude/Include b3Supervisory Call (SP) 0/1 = Exclude/Include b4Do Not Disturb (DND) 0/1 = Exclude/Include b5Guest Call (GST) 0/1 = Exclude/Include b6Emergency Call (EMG) 0/1 = Exclude/Include b7Overtime Call (OT) 0/1 = Exclude/Include SYSTEM TN IPX 1 ~ 63
CHAPTER 4 NDA-24298 Page 164 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 2100 b0 Not used 0b1 0b2 0b3 b4 Procedure for activating Call Waiting – Originating 0 = After hearing BT (SHF + ACC Code) only. 1 = After hearing BT (SHF + ACC Code) and upon going Off-Hook (ACC Code + Station No.) When activating this feature via dialing ACC Code + Station No., assign the access code of Call waiting - Originating by ASPA, CI = N. 0 b5Not used b6 Call Waiting-Terminating service (Automatic setting of Call Waiting) 0/1 = Out/In Service b7 Call Waiting Tone 0/1 = Once/At Intervals Note:When “1” is assigned, the interval of this tone is assigned in SYS-1, INDEX 152. SYSTEM TN IPX 1 ~ 63
NDA-24298 CHAPTER 4 Page 165 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 2110 b0 Not used 0b1 0b2 0b3 0b4Method of Day/Night mode change b5b4 0 0 = Via ATT Mode change 01=– 1 0 = Via External Switch 11=– (Usually assign “00”) 0b5 0b6Not used 0 b7 Disposition of DIT Call when the Station is Busy 0/1 = To Attendant Console/Waiting Note:In Direct-In Termination – CCIS service, the disposition of DIT call is not when the terminated station is busy but when the connected CCIS trunk is busy. When tandem connection is established during the CCIS trunk is in idle state, the call is not terminated to Attendant Console even if the destination station is busy. In this case, the call shall wait until the target station becomes idle. (The C.O. Line call terminated via ISDN network is to be released.) SYSTEM TN IPX 1 ~ 63
CHAPTER 4 NDA-24298 Page 166 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 212 b0Automatic Recall Ringer (Dterm)-Non-Exclusive Hold 0/1 = Required/Not Required b1Automatic Recall Ringer (Dterm)-Exclusive Hold 0/1 = Required/Not Required 0 b2 Not used 0 b3 0b4 0b5 0b6 0b7 13 b0 Sending SHF Signal from CAS Attendant Console to Satellite office 0/1 = SHF key/SHF key, 1st key Pad, or START key b1 ATT Status check when Day/Night Mode is changed via External Switch. 0/1 = Required/Not Required Note:When Day/Night Mode is changed via CAS- Satellite, assign data “1”. 0 b2 Not used 0 b3 0b4 0b5 0b6 0b7 SYSTEM TN IPX 1 ~ 63