NDA-24298 CHAPTER 4 Page 587 Issue 1 ARTKN : Assignment of Route Trunk Data for NDM 4. Data Sheet LOGICAL ROUTE NUMBER (LGRT)FUSION POINT CODE (FPC) 1-253ROUTE NUMBER (RT)TRUNK NUMBER (TK)LINE EQUIPMENT NUMBER (LENS)TENANT NUMBER (TN) MG U G LV
CHAPTER 4 NDA-24298 Page 588 Issue 1 AMAT : Assignment of Master Attendant Data AMAT: Assignment of Master Attendant Data 1. General When more than one Attendant Console has been installed for one tenant, this command assigns a Master Console for controlling the Day/Night function of all the Attendant Consoles on a tenant basis. 2. Precautions 1. This assignment is necessary when Day/Night changeover is controlled by a Master Console (the ASYD command, SYS 2, INDEX 2, bit2=1 & bit3=0). 2. If this Master Console is placed in the Night mode, all incoming calls will be directed to TAS or a Night Connection Fixed station. 3. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8. 4. The maximum number of Attendant Consoles (Attendant Consoles) should be assigned by the ASYD command, SYS 1, INDEX 9. 3. Data Entry Instructions Enter the desired Attendant Console to be operated as a master. 1 = Attendant Console which is assigned as RT = 901(ATT) by the ATRK command. (MATN) 2 = Attendant Console which is assigned as RT = 915 (NATT) by the ATRK command. (NATN) MODE (MODE) 1/2TENANT NUMBER (TN)ATTENDANT NUMBER (ATN) 1-16REMARKS Enter desired Attendant Console number assigned by the ATRK command. ATN
NDA-24298 CHAPTER 4 Page 589 Issue 1 AMAT : Assignment of Master Attendant Data 4. Data Sheet MODE 1/2TENANT NUMBER (TN) ATTENDANT NUMBER (ATN) 1-16REMARKS
CHAPTER 4 NDA-24298 Page 590 Issue 1 ASAT : Assignment of Specific Attendant Number Data ASAT: Assignment of Specific Attendant Number Data 1. General This command assigns a specific Attendant Number that allows a station user to access the desired operator. 2. Precautions 1. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8. If data for this command is common for all tenants (ASYD command, SYS1, INDEX 92, bit3=1), assign TN parameter as data “1” for all tenants. 2. The specific Attendant Number cannot be a station number or LDN already being used. 3. The maximum number of Attendant Consoles should be assigned by the ASYD command, SYS 1, INDEX 9. 3. Data Entry Instructions Enter the tenant number which affects the special attendant number TN TENANT NUMBER (TN)ACCESS CODE (ACC) MAXIMUM 5 DIGITSATTENDANT NUMBER (ATN)REMARKS Enter the special attendant number according to the station numbering plan. ACC Enter the ATN which corresponds to the TK parameter assigned by the ATRK command1 6 0 0 1 1 ATN
NDA-24298 CHAPTER 4 Page 591 Issue 1 ASAT : Assignment of Specific Attendant Number Data 4. Data Sheet TENANT NUMBER (TN) ACCESS CODE (ACC) MAXIMUM 5 DIGITSATTENDANT NUMBER (ATN)REMARKS
CHAPTER 4 NDA-24298 Page 592 Issue 1 ASATN : Assignment of Specific Attendant Number Data for NDM ASATN: Assignment of Specific Attendant Number Data for NDM 1. General This command assigns a specific Attendant Number that allows a station user to access the desired operator. The data assigned by this command is written in the Network Data Memory (NDM) of the Network Control Node (NCN), updating the NDM at each Local Node (LN). 2. Precautions 1. The specific attendant number cannot be a station number or LDN already being used. 2. The maximum number of Attendant Consoles should be assigned by the ASYD command, SYS 1, INDEX 9. 3. The telephone number for specifying the attendant console must be assigned by the ALGNN command prior to this command. 3. Data Entry Instructions USER GROUP NUMBER (UGN)ACCESS CODE (ACC) MAXIMUM 16 DIGITSFUSION POINT CODE (FPC) 1-253TENANT NUMBER (TN)ATTENDANT NUMBER (ATN) UGN Fixed to “1.”FPC Enter the PC of the node containing the specified attendant console.AT N Enter the ATN that corresponds to the TK parameter for the attendant console assigned by the ATRK command. ACC Enter the telephone number for special attendant number assigned by the ALGNN command. TN Enter the tenant number that affects the special number.
NDA-24298 CHAPTER 4 Page 593 Issue 1 ASATN : Assignment of Specific Attendant Number Data for NDM 4. Data Sheet USER GROUP NUMBER (UGN) ACCESS CODE (ACC) MAXIMUM 16 DIGITSFUSION POINT CODE (FPC) 1-253TENANT NUMBER (TN) ATTENDANT NUMBER (ATN) 1
CHAPTER 4 NDA-24298 Page 594 Issue 1 ATGL : Assignment of Trunk Group Busy Lamp Data ATGL: Assignment of Trunk Group Busy Lamp Data 1. General This command assigns the data related to the Trunk Group Busy Lamp which is accommodated on the Attendant Console. 2. Precautions 1. The maximum number of Attendant Consoles should be assigned by the ASYD command, SYS 1, INDEX 9. 2. The Trunk Group Busy Lamp is lit when the trunk routes specified by the RT parameter of this command are engaged. 3. The number of Trunk Group Busy Lamps to be applied (available TGN data range) is designated by the ASYD command, SYS1, INDEX15, bit0-3. 3. Data Entry Instructions Attendant Console number assigned by the ATRK command. ATN REMARK ROUTE NUMBER (RT) TRUNK GROUP (TGN) 1-10 ATTENDANT NUMBER (ATN) Enter the route number composed of the TGN. RT
NDA-24298 CHAPTER 4 Page 595 Issue 1 ATGL : Assignment of Trunk Group Busy Lamp Data 4. Data Sheet ATTENDANT NUMBER (ATN)TRUNK GROUP NUMBER (TGN) 1-10ROUTE NUMBER (RT)REMARKS
CHAPTER 4 NDA-24298 Page 596 Issue 1 ATGLL : Assignment of Trunk Group Busy Lamp Data for LDM ATGLL : Assignment of Trunk Group Busy Lamp Data for LDM 1. General This command is used to readout/assign/delete the controlling data of Trunk Group Busy Lamp which is accommodated on the Attendant Console. This data is written in Local Data Memory (LDM). 2. Precautions 1. The number of Attendant Consoles should be assigned by the ASYD command, SYS1, INDEX9. 2. The Trunk Group Busy Lamp lit when the trunk routes specified by the LGRT parameter of this command are engaged. 3. The number of Trunk Group Busy Lamps to be applied (capable TGN data range) is assigned by the ASYD command, SYS1, INDEX15, bit0-3. 3. Data Entry Instructions ATTTENDANT NUMBER (ATN) 1-30LOGICAL ROUTE NUMBER (LGRT) 1-899 TRUNK GROUP BUSY LAMP NUMBER (TGN) 1-10LGRT DATA (DATA) 0/1 REMARKS ATN Enter the Attendant Console Number assigned by the ATRK command. LGRT Enter the logical route number composed the Trunk Group (TGN).TGN Enter the Trunk Group Busy Lamp Number on the Attendant Console. DATA 0 = Not registration 1= Registration