    of 1020
    							NDA-24298 CHAPTER 4
    Page 167
    Issue 1
    ASYD : Assignment of System Data
    SYSTEM
    DATA
    TYPE
    (SYS)TENANT
    NUMBERSYSTEM
    DATA
    INDEX
    (INDEX)
    1 - 15DATA
    (DATA)
    00 - FF
    (Hex)BIT 
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    214
    b0CW Lamp on Attendant Console - Threshold CW Lamp flashes 
    when the number of Calls Waiting is greater than or equal to 
    this data.
    b3b2b1b0b3b2b1b0
    0 000=No flash1000=8 calls
    0 001=1 call 1001=9 calls
    0 010=2 calls 1010=10 calls
    0 011=3 calls 1011=11 calls
    0 100=4 calls 1100=12 calls
    0 101=5 calls 1101=13 calls
    0 110=6 calls 1110=14 calls
    0 111=7 calls 1111=15 calls
    b1
    b2
    b3
    b4
    Calls that activate CW Lamp Flash
    0/1 = All Calls/Only the types of Calls specified in SYS-2, 
    INDEXes 8 and 9
    0
    b5
    Not used 0b6
    0b7
    SYSTEM TN
    IPX 1 - 63 
    						
    							CHAPTER 4 NDA-24298
    Page 168
    Issue 1
    ASYD : Assignment of System Data 
    Note:
    When the numbering plans within the CCIS Network are unified, assign “0” to this data; otherwise assign
    “1.”
    SYSTEM
    DATA
    TYPE
    (SYS)TENANT
    NUMBER
    (TN)
    1 - 63SYSTEM 
    DATA
    INDEX
    (INDEX)
    0 - 15DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATASYSTEM DATA CONTENTS
    DATA
    0/1BIT
    2150
    b0Not used
    0
    b1Attendant Overflow Service
    0/1 = No/Yes
    0
    b2Not used
    b3
    Destination restriction for an outgoing trunk call originated 
    by Passing Dial Tone service
    0/1 = Effective/Ineffective
    b4
    The office that determines the transfer destination number 
    in Call Forwarding Assignment-Attendant Service.
    0/1 = Office that sets this service/Office in which the 
    t ra n s f e r ri n g  s t a t i o n  i s  l o c a t e d .                                  Note 
    0
    b5
    Not used 0b6
    0b7
    SYSTEM TN
    IPX 1 ~ 63 
    						
    							NDA-24298 CHAPTER 4
    Page 169
    Issue 1
    ASYD : Assignment of System Data
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 31DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    30
    b0
    ON Time is to be assigned a value from 
    1 Hex to F Hex (1~15). (Unit of Time is 
    Second.)Timer Value for Ringer 
    used for Incoming Trunk 
    Calls (Ringer Pattern 0)
    Note:Normally, this 
    Index is assigned 
    data 21 Hex. 
    (1 sec.-ON, 
    2 sec.-OFF)b1
    b2
    b3
    b4
    OFF Time is to be assigned a value 
    from 1 Hex to F Hex (1~15). (Unit of 
    Time is Second.)b5
    b6
    b7
    1
    b0
    ON Time is to be assigned a value from 
    1 Hex to F Hex (1~15). (Unit of Time is 
    Second.)Timer Value for Ringer 
    used for Station Calls 
    (Ringer Pattern 1)
    Note:Normally, this 
    Index is assigned 
    data 42 Hex. 
    (2 sec.-ON, 
    4 sec.-OFF)b1
    b2
    b3
    b4
    OFF Time is to be assigned a value 
    from 1 Hex to F Hex (1~15). (Unit of 
    Time is Second.)b5
    b6
    b7
    2
    b0Station Release Timer (TS) is to be 
    assigned a value from 1 Hex to F Hex 
    (1~15). (Release timing when 
    connected to an ORT)
    Timer Value Setting is (TS) 
    × 120 msec.Note:Normally, this 
    Index is assigned 
    data 91 Hex. 
    (TS = 120 msec., 
    TL = 1080 msec.)
    b1
    b2
    b3
    b4Hooking Timer (TL) is to be assigned a 
    value from 1 Hex to F Hex (1~15). 
    (SHF maximum timing)
    Timer Value Setting is (TL) 
    × 120 
    msec.
    b5
    b6
    b7 
    						
    							CHAPTER 4 NDA-24298
    Page 170
    Issue 1
    ASYD : Assignment of System Data 
    33
    b0
    2 Burst (0.4 sec.–ON, 0.2 sec.-OFF, 0.4 sec.–ON) on the ON Time for 
    Ringer Pattern 0
    0/1 = Not Required/Required
    b1
    2 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.4 sec.–ON) on the ON Time 
    for Ringer Pattern 1
    0/1 = Not Required/Required
    0
    b2
    Not used 0b3
    0b4
    b5
    3 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.8 sec.–ON, 0.2 sec.–OFF, 0.4 
    sec.-ON) on the ON Time for Ringer Pattern 5
    0/1 = Not Required/Required
    0
    b6Not used
    0
    b7Allow Bit 0 to be reset to 0
    0/1 = No/Yes
    400 Not used
    500 Not used
    600 Not used
    7
    b0
    ON time is to be assigned a value from 
    1 Hex to F Hex (1–15). (Unit of Time is 
    Second.)Timer Value for Ringer 
    used for Call Back, OG 
    Trunk Queuing, Call 
    Waiting, and Auto/Dial 
    Intercom (Ringer Pattern 
    5).
    Note:When this data is
    00 Hex, ROM
    data (2 sec.-ON,
    4 sec.-OFF) is
    automatically set.b1
    b2
    b3
    b4
    OFF time is to be assigned a value from 
    1 Hex to F Hex (1–15). (Unit of Time is 
    Second.)
    b5
    b6
    b7
    800 Not used
    900 Not used
    10 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 31DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 171
    Issue 1
    ASYD : Assignment of System Data
    311
    b0
    PBST: PB signal (DTMF) timer for Dterm and desk console.
    This data is to be assigned from 0 Hex to F Hex (0~15).
    Timer Value setting is (PBST + 1) 
    × 128 msec.
    b1
    b2
    b3
    0b4
    Not used 0b5
    0b6
    0b7
    12
    b0
    ON Time is to be assigned a value from 
    1 Hex to F Hex (1~15). (Unit of Time is 
    Seconds.)Timer Value for Data 
    Communication RS-232C 
    CI (Call Indicator; same as 
    RI: Ring Indicator) Signal
    Note: When this data is 
    00 Hex, Default 
    data is 
    automatically set 
    to 2 sec.–ON, 4 
    sec.–OFFb1
    b2
    b3
    b4
    OFF Time is to be assigned a value 
    from 1 Hex to F Hex (1-15). (Unit of 
    Time is Seconds.)
    b5
    b6
    b7
    13 00 Not used
    14 00 Not used
    15 00 Not used
    16 00 Not used
    17 00 Not used
    18 00 Not used
    19 00 Not used
    20 00 Not used
    21 00 Not used
    22 00 Not used
    23 00 Not used
    24 00 Not used
    25 00 Not used
    26 00 Not used
    27 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 31DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ON
    TIMEOFF
    TIME
    CI
    SIGNAL 
    						
    							CHAPTER 4 NDA-24298
    Page 172
    Issue 1
    ASYD : Assignment of System Data 
    328 00 Not used
    29 00 Not used
    30 00 Not used
    31 00 Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 31DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 173
    Issue 1
    ASYDL : Assignment of System Data into Local DM (LDM)
    ASYDL: Assignment of System Data into Local DM (LDM)
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    512 - 1535DATA
    (DATA)
    00 - FF
    (Hex)BIT 
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1512
    b0
    Fusion Point Code (FPC) of self node in hexadecimal.
    FPC 1-253 (01 Hex-FD Hex)
    Note:After assigning/changing the FPC, System
    Initialization (Non-Load Initialization) is
    required. Assign only for Fusion Network.
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    513 01
    b0Local Data Memory (LDM) usage. Assign “1 (the 
    memory block is used)” to the corresponding bit.b1
    b2
    b3
    b4
    b5
    b6
    b7
    514 01
    b0Network Data Memory (NDM) usage. Assign “1 (the 
    memory block is used)” to the corresponding bit.
    b1
    b2
    b3
    b4
    b5
    b6
    b7
    Note 1:Necessary data for the programming using commands for LDM. Usually 01H is assigned.
    When the Local Data Memory is not enough, change the value from 03H to 07H.
    Note 2:Necessary data for the programming commands for NDM. Usually 01H is assigned.
    When the Network Data Memory is not enough, change the value from 03H 
    → 07H → 0FH → 1F.
    bit Memory
    b0Memory Block #0
    b1Memory Block #1
    b2Memory Block #2
    bit Memory
    b0Memory Block #0
    b1Memory Block #1
    b2Memory Block #2
    b3Memory Block #3
    b4Memory Block #4
    b5Memory Block #5
    b6Memory Block #6 
    						
    							CHAPTER 4 NDA-24298
    Page 174
    Issue 1
    ASYDL : Assignment of System Data into Local DM (LDM)
    1515 IP Address (Hex) for PBX over External LAN
    Note:This data is valid when the PBX is connected
    to the external PC.
    When default IP address (172. 16. 253. 0) for the PBX 
    is used, this data setting is not necessary.
    Example:IP Address: 133. 206. 8. 1 516
    517
    518
    519 Subnet Mask (Hex) for PBX over External LAN
    Note:This data is valid when the PBX is connected
    to the external PC.
    When default IP address (172. 16. 253. 0) for the PBX 
    is used, this data setting is not necessary.
    Example:Subnet Mask: 255.255.0.0 520
    521
    522
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    512 - 1535DATA
    (DATA)
    00 - FF
    (Hex)BIT 
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    INDEX Set Hex
    515 85
    516 CE
    517 08
    518 01
    INDEX Set Hex
    519 FF
    520 FF
    521 00
    522 00 
    						
    							NDA-24298 CHAPTER 4
    Page 175
    Issue 1
    ASYDL : Assignment of System Data into Local DM (LDM)
    1523
    Default Gateway Address of External LAN 
    Gateway Address (IP address of Router) of Network 
    connecting PBX.
    Note:This data is valid when the PBX is connected
    to the external PC LAN.
    In the case of no Network Gateway,
    assignment data is 00 Hex. in Index 523
    through 526.
    Example:Default Gateway Address:
     133. 206. 8. 254
    524
    525
    526
    527
    b0 ~ b3
    Designate the maximum number of the tandem node 
    for Fusion connection.
    b4
    DP (Dial Pulse) relay broadcasting to Fusion Link
    0/1 = Invalid/Valid
    b5 ~ b7Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    512 - 1535DATA
    (DATA)
    00 - FF
    (Hex)BIT 
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    INDEX Set Hex
    523 85
    524 CE
    525 08
    526 FE
    xample:FCCS
     to B : 2 (two) tandem nodes
     to C : 3 (three) tandem nodes
    1
    ABC23 
    						
    							CHAPTER 4 NDA-24298
    Page 176
    Issue 1
    ASYDL : Assignment of System Data into Local DM (LDM)
    1528
    b0Voice Recognition Services Timer
    MTC = 0 - 15 (0h to Fh) seconds
    Timer value = MTC × TC
    This timer defaults to 30 seconds when 00h is 
    assigned.
    b1
    b2
    b3
    b4Timer Class (TC)
    b6b5b4b6b5b4b6b5b4
    0 0 0= -----011=2 sec.110=-----
    0 0 1 1 00 =30 sec.111=-----
    0 1 0= -----101=------
    b5
    b6
    b7
    529
    b0Parity Check Method for SMDR/MCI with LAN 
    Interface
    b0b1
    0 0 = Non-Parity Check
    1 0 = Odd Parity Check
    0 1 = Even Parity Checkb1
    b2 ~ b7Not used
    530
    b0FCCS Health Check Timer
    MTC = 0 - 15 (0h to Fh) Seconds
    Timer Value = MTC × TC
    This timer defaults to 30 seconds when 00h is 
    assigned.
    b1
    b2
    b3
    b4Timer Class (TC)
    b6b5b4b6b5b4b6b5b4
    0 0 0 = -----011=2 sec.110=-----
    0 0 1 = 1 00 =30 sec.111=8 sec.
    0 1 0 = -----101=5 sec.
    b5
    b6
    b7
    Is this timer in service?
    0/1 = No/Yes
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    512 - 1535DATA
    (DATA)
    00 - FF
    (Hex)BIT 
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    All NEC manuals Comments (0)