NEC Neax 2400 Ipx Office Data Specification
Have a look at the manual NEC Neax 2400 Ipx Office Data Specification online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NDA-24298 CHAPTER 4 Page 167 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)TENANT NUMBERSYSTEM DATA INDEX (INDEX) 1 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 214 b0CW Lamp on Attendant Console - Threshold CW Lamp flashes when the number of Calls Waiting is greater than or equal to this data. b3b2b1b0b3b2b1b0 0 000=No flash1000=8 calls 0 001=1 call 1001=9 calls 0 010=2 calls 1010=10 calls 0 011=3 calls 1011=11 calls 0 100=4 calls 1100=12 calls 0 101=5 calls 1101=13 calls 0 110=6 calls 1110=14 calls 0 111=7 calls 1111=15 calls b1 b2 b3 b4 Calls that activate CW Lamp Flash 0/1 = All Calls/Only the types of Calls specified in SYS-2, INDEXes 8 and 9 0 b5 Not used 0b6 0b7 SYSTEM TN IPX 1 - 63
CHAPTER 4 NDA-24298 Page 168 Issue 1 ASYD : Assignment of System Data Note: When the numbering plans within the CCIS Network are unified, assign “0” to this data; otherwise assign “1.” SYSTEM DATA TYPE (SYS)TENANT NUMBER (TN) 1 - 63SYSTEM DATA INDEX (INDEX) 0 - 15DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATASYSTEM DATA CONTENTS DATA 0/1BIT 2150 b0Not used 0 b1Attendant Overflow Service 0/1 = No/Yes 0 b2Not used b3 Destination restriction for an outgoing trunk call originated by Passing Dial Tone service 0/1 = Effective/Ineffective b4 The office that determines the transfer destination number in Call Forwarding Assignment-Attendant Service. 0/1 = Office that sets this service/Office in which the t ra n s f e r ri n g s t a t i o n i s l o c a t e d . Note 0 b5 Not used 0b6 0b7 SYSTEM TN IPX 1 ~ 63
NDA-24298 CHAPTER 4 Page 169 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 31DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 30 b0 ON Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Second.)Timer Value for Ringer used for Incoming Trunk Calls (Ringer Pattern 0) Note:Normally, this Index is assigned data 21 Hex. (1 sec.-ON, 2 sec.-OFF)b1 b2 b3 b4 OFF Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Second.)b5 b6 b7 1 b0 ON Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Second.)Timer Value for Ringer used for Station Calls (Ringer Pattern 1) Note:Normally, this Index is assigned data 42 Hex. (2 sec.-ON, 4 sec.-OFF)b1 b2 b3 b4 OFF Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Second.)b5 b6 b7 2 b0Station Release Timer (TS) is to be assigned a value from 1 Hex to F Hex (1~15). (Release timing when connected to an ORT) Timer Value Setting is (TS) × 120 msec.Note:Normally, this Index is assigned data 91 Hex. (TS = 120 msec., TL = 1080 msec.) b1 b2 b3 b4Hooking Timer (TL) is to be assigned a value from 1 Hex to F Hex (1~15). (SHF maximum timing) Timer Value Setting is (TL) × 120 msec. b5 b6 b7
CHAPTER 4 NDA-24298 Page 170 Issue 1 ASYD : Assignment of System Data 33 b0 2 Burst (0.4 sec.–ON, 0.2 sec.-OFF, 0.4 sec.–ON) on the ON Time for Ringer Pattern 0 0/1 = Not Required/Required b1 2 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.4 sec.–ON) on the ON Time for Ringer Pattern 1 0/1 = Not Required/Required 0 b2 Not used 0b3 0b4 b5 3 Burst (0.4 sec.–ON, 0.2 sec.–OFF, 0.8 sec.–ON, 0.2 sec.–OFF, 0.4 sec.-ON) on the ON Time for Ringer Pattern 5 0/1 = Not Required/Required 0 b6Not used 0 b7Allow Bit 0 to be reset to 0 0/1 = No/Yes 400 Not used 500 Not used 600 Not used 7 b0 ON time is to be assigned a value from 1 Hex to F Hex (1–15). (Unit of Time is Second.)Timer Value for Ringer used for Call Back, OG Trunk Queuing, Call Waiting, and Auto/Dial Intercom (Ringer Pattern 5). Note:When this data is 00 Hex, ROM data (2 sec.-ON, 4 sec.-OFF) is automatically set.b1 b2 b3 b4 OFF time is to be assigned a value from 1 Hex to F Hex (1–15). (Unit of Time is Second.) b5 b6 b7 800 Not used 900 Not used 10 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 31DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 171 Issue 1 ASYD : Assignment of System Data 311 b0 PBST: PB signal (DTMF) timer for Dterm and desk console. This data is to be assigned from 0 Hex to F Hex (0~15). Timer Value setting is (PBST + 1) × 128 msec. b1 b2 b3 0b4 Not used 0b5 0b6 0b7 12 b0 ON Time is to be assigned a value from 1 Hex to F Hex (1~15). (Unit of Time is Seconds.)Timer Value for Data Communication RS-232C CI (Call Indicator; same as RI: Ring Indicator) Signal Note: When this data is 00 Hex, Default data is automatically set to 2 sec.–ON, 4 sec.–OFFb1 b2 b3 b4 OFF Time is to be assigned a value from 1 Hex to F Hex (1-15). (Unit of Time is Seconds.) b5 b6 b7 13 00 Not used 14 00 Not used 15 00 Not used 16 00 Not used 17 00 Not used 18 00 Not used 19 00 Not used 20 00 Not used 21 00 Not used 22 00 Not used 23 00 Not used 24 00 Not used 25 00 Not used 26 00 Not used 27 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 31DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ON TIMEOFF TIME CI SIGNAL
CHAPTER 4 NDA-24298 Page 172 Issue 1 ASYD : Assignment of System Data 328 00 Not used 29 00 Not used 30 00 Not used 31 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 31DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 173 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) ASYDL: Assignment of System Data into Local DM (LDM) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1512 b0 Fusion Point Code (FPC) of self node in hexadecimal. FPC 1-253 (01 Hex-FD Hex) Note:After assigning/changing the FPC, System Initialization (Non-Load Initialization) is required. Assign only for Fusion Network. b1 b2 b3 b4 b5 b6 b7 513 01 b0Local Data Memory (LDM) usage. Assign “1 (the memory block is used)” to the corresponding bit.b1 b2 b3 b4 b5 b6 b7 514 01 b0Network Data Memory (NDM) usage. Assign “1 (the memory block is used)” to the corresponding bit. b1 b2 b3 b4 b5 b6 b7 Note 1:Necessary data for the programming using commands for LDM. Usually 01H is assigned. When the Local Data Memory is not enough, change the value from 03H to 07H. Note 2:Necessary data for the programming commands for NDM. Usually 01H is assigned. When the Network Data Memory is not enough, change the value from 03H → 07H → 0FH → 1F. bit Memory b0Memory Block #0 b1Memory Block #1 b2Memory Block #2 bit Memory b0Memory Block #0 b1Memory Block #1 b2Memory Block #2 b3Memory Block #3 b4Memory Block #4 b5Memory Block #5 b6Memory Block #6
CHAPTER 4 NDA-24298 Page 174 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1515 IP Address (Hex) for PBX over External LAN Note:This data is valid when the PBX is connected to the external PC. When default IP address (172. 16. 253. 0) for the PBX is used, this data setting is not necessary. Example:IP Address: 133. 206. 8. 1 516 517 518 519 Subnet Mask (Hex) for PBX over External LAN Note:This data is valid when the PBX is connected to the external PC. When default IP address (172. 16. 253. 0) for the PBX is used, this data setting is not necessary. Example:Subnet Mask: 255.255.0.0 520 521 522 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT INDEX Set Hex 515 85 516 CE 517 08 518 01 INDEX Set Hex 519 FF 520 FF 521 00 522 00
NDA-24298 CHAPTER 4 Page 175 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1523 Default Gateway Address of External LAN Gateway Address (IP address of Router) of Network connecting PBX. Note:This data is valid when the PBX is connected to the external PC LAN. In the case of no Network Gateway, assignment data is 00 Hex. in Index 523 through 526. Example:Default Gateway Address: 133. 206. 8. 254 524 525 526 527 b0 ~ b3 Designate the maximum number of the tandem node for Fusion connection. b4 DP (Dial Pulse) relay broadcasting to Fusion Link 0/1 = Invalid/Valid b5 ~ b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT INDEX Set Hex 523 85 524 CE 525 08 526 FE xample:FCCS to B : 2 (two) tandem nodes to C : 3 (three) tandem nodes 1 ABC23
CHAPTER 4 NDA-24298 Page 176 Issue 1 ASYDL : Assignment of System Data into Local DM (LDM) 1528 b0Voice Recognition Services Timer MTC = 0 - 15 (0h to Fh) seconds Timer value = MTC × TC This timer defaults to 30 seconds when 00h is assigned. b1 b2 b3 b4Timer Class (TC) b6b5b4b6b5b4b6b5b4 0 0 0= -----011=2 sec.110=----- 0 0 1 1 00 =30 sec.111=----- 0 1 0= -----101=------ b5 b6 b7 529 b0Parity Check Method for SMDR/MCI with LAN Interface b0b1 0 0 = Non-Parity Check 1 0 = Odd Parity Check 0 1 = Even Parity Checkb1 b2 ~ b7Not used 530 b0FCCS Health Check Timer MTC = 0 - 15 (0h to Fh) Seconds Timer Value = MTC × TC This timer defaults to 30 seconds when 00h is assigned. b1 b2 b3 b4Timer Class (TC) b6b5b4b6b5b4b6b5b4 0 0 0 = -----011=2 sec.110=----- 0 0 1 = 1 00 =30 sec.111=8 sec. 0 1 0 = -----101=5 sec. b5 b6 b7 Is this timer in service? 0/1 = No/Yes SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 512 - 1535DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT