    							NDA-24298 CHAPTER 4
    Page 77
    Issue 1
    ASYD : Assignment of System Data
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA) 
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    135b
    0
    Not used b
    1
    b2
    b3
    b4
    b5
    b6
    b7
    36 00Not used
    37 00
    Not used
    38b
    0Stand-Alone Fault Printer Accommodation Designation “1” is to 
    be assigned to each bit corresponding to the Port Number of the 
    IOC circuit card.
    b
    0 = Port 0 b1 = Port 1
    b
    2 = Port 2  b3 = Port 3
    b
    4 = Port 4 b5 = Port 5
    b
    6 = Port 6  b7 = Port 7
    Note:Usually, Port 1 is used for System Message Printer. b
    1
    b2
    b3
    b4
    b5
    b6
    b7
    39b
    0System Message Automatic Output Designation for Stand-Alone 
    Fault Printer
    “1” is to be assigned to each bit corresponding to the Port Number 
    of the IOC circuit card.
    b
    0 = Port 0 b1 = Port 1
    b
    2 = Port 2  b3 = Port 3
    b
    4 = Port 4 b5 = Port 5
    b
    6 = Port 6  b7 = Port 7
    Note:Usually, Port 1 is used for System Message Printer;
    assign the same data as INDEX 38. b
    1
    b2
    b3
    b4
    b5
    b6
    b7 
    						
    							CHAPTER 4 NDA-24298
    Page 78
    Issue 1
    ASYD : Assignment of System Data
    140 00b
    0~b4Not used
    b5
    SMDR Buffer Overflow Alarm
    0/1 = Fault @ 80%, Clear @ 50%/Use Indexes 249 and 250.
    b6Not used
    b7Not used
    41b
    0~b6
    OG Queuing Override – DDD Seizing Timer
    Timer Counter (TC) is to be assigned a value from 01 Hex to 7F 
    Hex.
    Timer Value Setting is (TC) 
    × 30 sec.
    Note:When this data (TC) is 00 Hex, default data of 3 minutes
    is set.
    0b
    7Not used
    42
    b0 ~ b1Not used
    b
    2
    System Message “5-Q”, ACD MIS Lock up, is to be output
    0/1 = Invalid/Valid
    b3Not used
    b
    4Not used
    b6Not used
    b
    7
    S S T,  S P D T  To n e
    0/1 = Continuous/Burst
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA) 
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 79
    Issue 1
    ASYD : Assignment of System Data
    143b
    0
    For Remote Access to System, is Forced Account (F/A) Code 
    Dialing required upon receiving RBT?
    0/1 = Required/Not Required
    0b
    1Not used
    b
    2
    Send SST after ACC Code dialing for Authorization Code or F/A 
    code is dialed using LCR Access
    0/1 = Out/In Service
    0b
    3Not used
    b
    4
    ATT Re-enters Loop on Serial Call
    0/1 = Restriction/Allowed
    b
    5
    Send DT to the distant Office upon receiving Terminated Office 
    Code (Tandem)
    0/1 = Not Required/Required
    0b
    6Not used
    b
    7
    Restriction for Dialing more than the max. of necessary digits (as 
    assigned via command AMND)
    0/1 = Not Required/Required
    Note:If a calling party dials more than the maximum
    necessary digits, the calling party receives reorder tone.
    44b
    0
    Automatic Circuit Assurance
    0/1 = Out/In Service
    0b
    1
    Not used 0b
    2
    0b3
    0b4
    0b5
    0b6
    0b7
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA) 
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 80
    Issue 1
    ASYD : Assignment of System Data
    145
    Abnormal Call, Short Duration Timer for Automatic Circuit 
    Assurance service (when INDEX = 44, b
    0 = 1)
    Timer counter (TC) is to be assigned a value from 02 Hex to FF 
    Hex. (2 - 255 sec.)
    Timer Value = TC × 1 sec.
    Note:When TC = 00 Hex, this timer is not set.
    46
    Abnormal Call, Long Duration Timer for Automatic Circuit 
    Assurance service
    (when INDEX = 44, b
    0 = 1)
    TC is to be assigned a value from 01 Hex to FF Hex. (1 - 255 
    min.)
    Timer Value = TC × 1 min.
    Note:When TC = 00 Hex, this timer is not set.
    47b
    0
    Traffic Measurement Indication
    0/1 = CCS Indication/Erlang Indication
    b
    2TCFI Timer (Timer Internal Between Messages)
    b
    2b1b2b1
    0 0 = 2 seconds 1 1 = Application Dependent 
    (Standard Assignment)
    0 1 = 4 seconds
    1 0 = 8 seconds
    Display for TCFD
    0/1 = MSG/Last input
    0 = Normal assignment b
    2
    0b3
    0b4
    SCF (FN = 127) Tone Control
    0/1 = Invalid/Valid
    0b
    5Not used
    0b
    6
    b7
    Traffic Measurement for Terminal and Route Traffic (ATRF)
    0/1 = Out/In Service
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA) 
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 81
    Issue 1
    ASYD : Assignment of System Data
    Note:
    When assigning data for INDEXes 56 and 57, be sure to assign data in such a way that the data value of
    INDEX 56 is larger than INDEX 57 (Value of INDEX 56>Value of INDEX57).
    148
    Do not assign these INDEXes.
    (INDEXes 48 ~ 55 are used for the Grade 1 Password Code.) 49
    50
    51
    52
    53
    54
    55
    56 FFb
    0Set Line Load Control (Automatic) Execution Occupancy Rate.
    Set execution of line load control (automatic) by the usage rate 
    (occupancy) rate of the CPU. 
    Example:
    For executing line load control by CPU usage rate 
    (occupancy rate) 90%, assign 5AH.
    To assign this Index, take the occupancy rate desired 
    and convert this value to Hex (e.g., 90 = 5AH). b
    1
    b2
    b3
    b4
    b5
    b6
    b7
    57 FFb
    0Set Line Load Control (Automatic) Execution Cancel Occupancy 
    Rate.
    Set cancellation of line load control (automatic) by the usage rate 
    (occupancy) rate of the CPU.
    Example:
    For cancelling line load control by CPU usage rate 
    (occupancy rate) 80%, assign 50H.
    To assign this Index, take the occupancy rate desired 
    and convert this value to Hex (e.g., 80 = 50H). b
    1
    b2
    b3
    b4
    b5
    b6
    b7
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA) 
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 82
    Issue 1
    ASYD : Assignment of System Data
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA)
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    158
    b0
    Configuration of CPU (for IPX)
    0/1 = Single/Dual
    For IPX, assign “0.”
    0
    b1Not used
    1
    b2Trunk Ineffective Hold Detect Processing Program Start 
    0/1 = Not Required/Required (Always assign “1.”)
    1
    b3Send Forced Off-Hook Supervisory Command
    0/1 = Not Required/Required (Always assign “1.”)
    0
    b4Not used
    0b5
    b6
    LP Residual Link Detect (for IPX-UMG system only)
    0 = All LP per a day
    1 = 1 LPG per a day (1LPG consists of four IMGs)
    Note:As related to the total necessary time of Routine
    Diagnosis, designate the number of LP to be executed
    the LP Residual Link Detect per a day. This data is
    effective when ASYD SYS1 INDEX90 bit3=1 (Residual
    Link Detect is to be executed) is assigned.
    0
    b7Not used
    59
    b0Incoming Call Restriction from TRK during Line Load Control
    0/1 = Not Required/Required
    b1
    LCR – Controlled Alternate PRSC (FRLs) service (urgent mode 
    via AUNE)
    0/1 = Out/In Service
    Note:When “1” is assigned, the FRL key on the Attendant
    Console is effective.
    b2DID Busy Condition
    0/1 = No Tone/Busy Tone
    0
    b3Not used
    0b4
    0b5Number of Tones sent for Override services
    0/1 = 2/3 Tones
    0
    b6Send Tones for Attendant and Override services
    0/1 = Yes/No
    b7Intercom service for Dterm
    0/1 = Out/In Service 
    						
    							NDA-24298 CHAPTER 4
    Page 83
    Issue 1
    ASYD : Assignment of System Data
    1600b
    0
    Not used 0b1
    0b2
    b3
    UCD Queuing
    0/1 = Required (RBT)/Not Required (BT)
    (Most = 0 when the MCI is in service.)
    b
    4
    Nailed Down Connection (Fixed Connection) service
    0/1 = Out/In service
    b
    5
    Send Warning Tone to interrupted parties when Attendant 
    Interruption service is operated.
    0/1 = Required/Not Required
    0b
    6Not used
    0b
    7
    610b
    0
    Not used 0b
    1
    0b2
    0b3
    0b4
    b5
    Call Waiting Display – UCD/ACD Service
    0/1 = Out/In Service
    0b
    6Not used
    0b
    7
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA)
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 84
    Issue 1
    ASYD : Assignment of System Data
    1620b
    0
    Not used 0b
    1
    0b2
    0b3
    0b4
    0b5
    b6AC T/ ST  – BY Change over at Routine Diagnosis
    00=Every time
    0 1 = Once a week (On Sunday)
    1 0 = Once a month (On the 1st Sunday of the month)
    11=–
    Note:Assign the Routine Diagnosis Program start time in
    SYS-1, INDEXes 87 and 88. b
    7
    63 00b
    0
    Blind Transfer for stations in service
    0/1 = No/Yes
    b1
    Not usedb2
    b3
    b4Not used
    b5
    Exclusive Hold for stations
    0/1 = Yes/No
    b6Not usedb7
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA)
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    b7 b6 
    						
    							NDA-24298 CHAPTER 4
    Page 85
    Issue 1
    ASYD : Assignment of System Data
    164b
    0
    µ law/A law for TDSW
    0 = µ law (Japan, North America, Canada, and Hong Kong)
    1 = A law (Europe, other nations)
    b
    1Display of Call Waiting Lamp (on Attendant Console) service
    0 0 = When PA lamp illuminates
    0 1 = When busy lamp field is not displayed
    10=Always
    11=– b
    2
    b3Howler Tone sending service
    00=Out of Service
    0 1 = Send one time only
    1 0 = Repeat every 30 sec.
    11=–
    Note:The Sending Timer may be changed to a value other
    than 30 sec. via SYS-1, INDEX = 146. b
    4
    0b5Not used
    0b
    6
    Type of Attendant Camp-On
    0/1 = Automatic/Semi-Auto (Normally Assign “0.”)
    b
    7
    Music On Hold service
    0/1 = Out/In Service
    65
    Maximum Number of Routes
    IPX 1 ~ 255 = 01 ~ FF Hex
    66 00
    Not used
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA)
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    b2 b1
    b4 b3 
    						
    							CHAPTER 4 NDA-24298
    Page 86
    Issue 1
    ASYD : Assignment of System Data
    167 000b
    0
    Not used 0b
    1
    0b2
    0b3
    0b4
    0b5
    0b6
    SMDR Control Circuit Card Designation
    0/1 = MRC/SMDC (Always assign “0.”)
    0b
    7
    SMDR Sending Designation
    0/1 = AP/SMDC (Always assign “0.”)
    68b
    0
    Operating method for busy station service (Call back, Executive 
    Right of Way, etc.)
    0/1 = SHF + Access Code/Last Digit + Access Code
    b
    1
    Operating method for Individual Trunk Access (ATT) service
    0 = Route No. + Trunk No.
    1 = C.O. Code (as assigned via command ACOC)
    b
    2
    Ringing Signal type for TAS indicator
    0/1 = Interval/Continuous
    b
    3
    OG Trunk Queuing (On-Hook) Automatic Cancel 
    0/1 = Out/In Service
    b
    4
    TKSL key on the Attendant Console (for Individual Trunk Ac-
    cess service)
    0/1 = Out/In service
    0b
    5Not used
    b
    6
    Ground Button (GB) used for SHF
    0/1 = Not Required/Required
    Used only for 
    Special 
    Common 
    Battery 
    Telephones b
    7
    OG call operation
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 511DATA 
    (DATA)
    00 – FF 
    (Hex)BIT 
    CORRESPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    via Attendant 
    ConsoleDirect Dial
    Access
    0Off-HookOff-Hook by 
    pressing GB
    1Off-Hook by 
    pressing GBOff-Hook
    –
    b7 
    						