NDA-24298 CHAPTER 4 Page 77 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 135b 0 Not used b 1 b2 b3 b4 b5 b6 b7 36 00Not used 37 00 Not used 38b 0Stand-Alone Fault Printer Accommodation Designation “1” is to be assigned to each bit corresponding to the Port Number of the IOC circuit card. b 0 = Port 0 b1 = Port 1 b 2 = Port 2 b3 = Port 3 b 4 = Port 4 b5 = Port 5 b 6 = Port 6 b7 = Port 7 Note:Usually, Port 1 is used for System Message Printer. b 1 b2 b3 b4 b5 b6 b7 39b 0System Message Automatic Output Designation for Stand-Alone Fault Printer “1” is to be assigned to each bit corresponding to the Port Number of the IOC circuit card. b 0 = Port 0 b1 = Port 1 b 2 = Port 2 b3 = Port 3 b 4 = Port 4 b5 = Port 5 b 6 = Port 6 b7 = Port 7 Note:Usually, Port 1 is used for System Message Printer; assign the same data as INDEX 38. b 1 b2 b3 b4 b5 b6 b7
CHAPTER 4 NDA-24298 Page 78 Issue 1 ASYD : Assignment of System Data 140 00b 0~b4Not used b5 SMDR Buffer Overflow Alarm 0/1 = Fault @ 80%, Clear @ 50%/Use Indexes 249 and 250. b6Not used b7Not used 41b 0~b6 OG Queuing Override – DDD Seizing Timer Timer Counter (TC) is to be assigned a value from 01 Hex to 7F Hex. Timer Value Setting is (TC) × 30 sec. Note:When this data (TC) is 00 Hex, default data of 3 minutes is set. 0b 7Not used 42 b0 ~ b1Not used b 2 System Message “5-Q”, ACD MIS Lock up, is to be output 0/1 = Invalid/Valid b3Not used b 4Not used b6Not used b 7 S S T, S P D T To n e 0/1 = Continuous/Burst SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 79 Issue 1 ASYD : Assignment of System Data 143b 0 For Remote Access to System, is Forced Account (F/A) Code Dialing required upon receiving RBT? 0/1 = Required/Not Required 0b 1Not used b 2 Send SST after ACC Code dialing for Authorization Code or F/A code is dialed using LCR Access 0/1 = Out/In Service 0b 3Not used b 4 ATT Re-enters Loop on Serial Call 0/1 = Restriction/Allowed b 5 Send DT to the distant Office upon receiving Terminated Office Code (Tandem) 0/1 = Not Required/Required 0b 6Not used b 7 Restriction for Dialing more than the max. of necessary digits (as assigned via command AMND) 0/1 = Not Required/Required Note:If a calling party dials more than the maximum necessary digits, the calling party receives reorder tone. 44b 0 Automatic Circuit Assurance 0/1 = Out/In Service 0b 1 Not used 0b 2 0b3 0b4 0b5 0b6 0b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 80 Issue 1 ASYD : Assignment of System Data 145 Abnormal Call, Short Duration Timer for Automatic Circuit Assurance service (when INDEX = 44, b 0 = 1) Timer counter (TC) is to be assigned a value from 02 Hex to FF Hex. (2 - 255 sec.) Timer Value = TC × 1 sec. Note:When TC = 00 Hex, this timer is not set. 46 Abnormal Call, Long Duration Timer for Automatic Circuit Assurance service (when INDEX = 44, b 0 = 1) TC is to be assigned a value from 01 Hex to FF Hex. (1 - 255 min.) Timer Value = TC × 1 min. Note:When TC = 00 Hex, this timer is not set. 47b 0 Traffic Measurement Indication 0/1 = CCS Indication/Erlang Indication b 2TCFI Timer (Timer Internal Between Messages) b 2b1b2b1 0 0 = 2 seconds 1 1 = Application Dependent (Standard Assignment) 0 1 = 4 seconds 1 0 = 8 seconds Display for TCFD 0/1 = MSG/Last input 0 = Normal assignment b 2 0b3 0b4 SCF (FN = 127) Tone Control 0/1 = Invalid/Valid 0b 5Not used 0b 6 b7 Traffic Measurement for Terminal and Route Traffic (ATRF) 0/1 = Out/In Service SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 81 Issue 1 ASYD : Assignment of System Data Note: When assigning data for INDEXes 56 and 57, be sure to assign data in such a way that the data value of INDEX 56 is larger than INDEX 57 (Value of INDEX 56>Value of INDEX57). 148 Do not assign these INDEXes. (INDEXes 48 ~ 55 are used for the Grade 1 Password Code.) 49 50 51 52 53 54 55 56 FFb 0Set Line Load Control (Automatic) Execution Occupancy Rate. Set execution of line load control (automatic) by the usage rate (occupancy) rate of the CPU. Example: For executing line load control by CPU usage rate (occupancy rate) 90%, assign 5AH. To assign this Index, take the occupancy rate desired and convert this value to Hex (e.g., 90 = 5AH). b 1 b2 b3 b4 b5 b6 b7 57 FFb 0Set Line Load Control (Automatic) Execution Cancel Occupancy Rate. Set cancellation of line load control (automatic) by the usage rate (occupancy) rate of the CPU. Example: For cancelling line load control by CPU usage rate (occupancy rate) 80%, assign 50H. To assign this Index, take the occupancy rate desired and convert this value to Hex (e.g., 80 = 50H). b 1 b2 b3 b4 b5 b6 b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 82 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 158 b0 Configuration of CPU (for IPX) 0/1 = Single/Dual For IPX, assign “0.” 0 b1Not used 1 b2Trunk Ineffective Hold Detect Processing Program Start 0/1 = Not Required/Required (Always assign “1.”) 1 b3Send Forced Off-Hook Supervisory Command 0/1 = Not Required/Required (Always assign “1.”) 0 b4Not used 0b5 b6 LP Residual Link Detect (for IPX-UMG system only) 0 = All LP per a day 1 = 1 LPG per a day (1LPG consists of four IMGs) Note:As related to the total necessary time of Routine Diagnosis, designate the number of LP to be executed the LP Residual Link Detect per a day. This data is effective when ASYD SYS1 INDEX90 bit3=1 (Residual Link Detect is to be executed) is assigned. 0 b7Not used 59 b0Incoming Call Restriction from TRK during Line Load Control 0/1 = Not Required/Required b1 LCR – Controlled Alternate PRSC (FRLs) service (urgent mode via AUNE) 0/1 = Out/In Service Note:When “1” is assigned, the FRL key on the Attendant Console is effective. b2DID Busy Condition 0/1 = No Tone/Busy Tone 0 b3Not used 0b4 0b5Number of Tones sent for Override services 0/1 = 2/3 Tones 0 b6Send Tones for Attendant and Override services 0/1 = Yes/No b7Intercom service for Dterm 0/1 = Out/In Service
NDA-24298 CHAPTER 4 Page 83 Issue 1 ASYD : Assignment of System Data 1600b 0 Not used 0b1 0b2 b3 UCD Queuing 0/1 = Required (RBT)/Not Required (BT) (Most = 0 when the MCI is in service.) b 4 Nailed Down Connection (Fixed Connection) service 0/1 = Out/In service b 5 Send Warning Tone to interrupted parties when Attendant Interruption service is operated. 0/1 = Required/Not Required 0b 6Not used 0b 7 610b 0 Not used 0b 1 0b2 0b3 0b4 b5 Call Waiting Display – UCD/ACD Service 0/1 = Out/In Service 0b 6Not used 0b 7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 84 Issue 1 ASYD : Assignment of System Data 1620b 0 Not used 0b 1 0b2 0b3 0b4 0b5 b6AC T/ ST – BY Change over at Routine Diagnosis 00=Every time 0 1 = Once a week (On Sunday) 1 0 = Once a month (On the 1st Sunday of the month) 11=– Note:Assign the Routine Diagnosis Program start time in SYS-1, INDEXes 87 and 88. b 7 63 00b 0 Blind Transfer for stations in service 0/1 = No/Yes b1 Not usedb2 b3 b4Not used b5 Exclusive Hold for stations 0/1 = Yes/No b6Not usedb7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT b7 b6
NDA-24298 CHAPTER 4 Page 85 Issue 1 ASYD : Assignment of System Data 164b 0 µ law/A law for TDSW 0 = µ law (Japan, North America, Canada, and Hong Kong) 1 = A law (Europe, other nations) b 1Display of Call Waiting Lamp (on Attendant Console) service 0 0 = When PA lamp illuminates 0 1 = When busy lamp field is not displayed 10=Always 11=– b 2 b3Howler Tone sending service 00=Out of Service 0 1 = Send one time only 1 0 = Repeat every 30 sec. 11=– Note:The Sending Timer may be changed to a value other than 30 sec. via SYS-1, INDEX = 146. b 4 0b5Not used 0b 6 Type of Attendant Camp-On 0/1 = Automatic/Semi-Auto (Normally Assign “0.”) b 7 Music On Hold service 0/1 = Out/In Service 65 Maximum Number of Routes IPX 1 ~ 255 = 01 ~ FF Hex 66 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT b2 b1 b4 b3
CHAPTER 4 NDA-24298 Page 86 Issue 1 ASYD : Assignment of System Data 167 000b 0 Not used 0b 1 0b2 0b3 0b4 0b5 0b6 SMDR Control Circuit Card Designation 0/1 = MRC/SMDC (Always assign “0.”) 0b 7 SMDR Sending Designation 0/1 = AP/SMDC (Always assign “0.”) 68b 0 Operating method for busy station service (Call back, Executive Right of Way, etc.) 0/1 = SHF + Access Code/Last Digit + Access Code b 1 Operating method for Individual Trunk Access (ATT) service 0 = Route No. + Trunk No. 1 = C.O. Code (as assigned via command ACOC) b 2 Ringing Signal type for TAS indicator 0/1 = Interval/Continuous b 3 OG Trunk Queuing (On-Hook) Automatic Cancel 0/1 = Out/In Service b 4 TKSL key on the Attendant Console (for Individual Trunk Ac- cess service) 0/1 = Out/In service 0b 5Not used b 6 Ground Button (GB) used for SHF 0/1 = Not Required/Required Used only for Special Common Battery Telephones b 7 OG call operation SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT via Attendant ConsoleDirect Dial Access 0Off-HookOff-Hook by pressing GB 1Off-Hook by pressing GBOff-Hook – b7