    							NDA-24298 CHAPTER 4
    Page 687
    Issue 1
    AUCDN : Assignment of UCD Control Data for NDM
    AUCDN: Assignment of UCD Control Data for NDM
    1. General
    This command assigns the miscellaneous data related to the Uniform Call Distribution (UCD) for Fusion
    Service. The data assigned on this command is written in the Network Data Memory (NDM) of the Network
    Control Node (NCN), updating the NDM at each Local Node (LN).
    2. Precautions
    1. The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHUN
    command.
    2. This command can be specified using the following UCD related options: 
    (a) The number of calls in UCD queuing which is used for the UCD Peg Count.  
    (b) The threshold of the UCD Call Waiting Lamp (which is accommodated on a D
    term) starts to flash. 
    (c) Denial of the MCI call result text of the call terminated to the UCD group. 
    3. The following data should also be assigned for UCD - Call Waiting lamp flashing:
     ASYD command, SYS1, INDEX 61, b5 = 1 (Call Waiting Display-UCD in Service) 
     AKYD command, FKY = 47 (UCD Call Waiting Lamp)
    4. After the data assignment, the line circuit card which contains the UCD group stations must be initialized
    (turn the MB key ON/OFF). 
    						
    							CHAPTER 4 NDA-24298
    Page 688
    Issue 1
    AUCDN : Assignment of UCD Control Data for NDM
    3. Data Entry Instructions
    Enter the number of calls in the UCD queue.
    (This value is used for UCD Peg Count.)QTH
    Enter the number of calls in the UCD queue.
    (This value is used for UCD Call Waiting Lamp on Dterm) CWT
    UCD 
    QUEUING 
    PEG COUNT 
    VALUE 
    (QTH ACT) 0/1UCD 
    QUEUING 
    PEG COUNT 
    VALUE 
    (QTH ) 0-255THRESHOLD 
    VALUE OF 
    CALL WAITING 
    (CWT)
    1-255MCI DATA
    TRANSFER 
    (MCI)
    0/1 USER
    GROUP
    NUMBER
    (UGN)
    UGN and TELN
    QTH ACT
    UCD queuing value (used for Peg Count) is:
     0 = Invalid (QTH parameter is not assigned)
     1 = Valid (QTH parameter is assigned)MCI
    The call record to the UCD group 
    is transferred to MCI
     0 = Valid               1 = Invalid
    UGN and TELN (UCD pilot station number) parameters should be assigned with respect to the data assigned by the ASHUN
    command.
    TELEPHONE
    NUMBER
    (TELN)
    16 digits maximum 
    						
    							NDA-24298 CHAPTER 4
    Page 689
    Issue 1
    AUCDN : Assignment of UCD Control Data for NDM
    4. Data Sheet
    USER 
    GROUP
    NUMBER 
    (UGN)TELEPHONE NUMBER 
    (TELN)
    16 digits maximumUCD QUEUING 
    PEG COUNT 
    VA L U E
    (QTH ACT) 
    0/1UCD QUEUING 
    PEG COUNT 
    VA L U E  
    (QTH)
     0-255THRESHOLD 
    VALUE OF CALL 
    WAITING 
    (CWT)
    1-255MCI DATA 
    TRANSFER 
    (MCI)
    0/1 
    						
    							CHAPTER 4 NDA-24298
    Page 690
    Issue 1
    AUOG : Assignment of UCD Overflow Group
    AUOG: Assignment of UCD Overflow Group
    1. General
    This command assigns the data related to the Overflow - UCD service feature.
    2. Precautions
    1. The UCD member station and the UCD pilot (controlling station) station should be assigned by the ASHU
    command.
    2. The calls terminate to the designated group can overflow (forward) to another UCD group. They overflow
    from TN-A, STN-A to TN-B, STN-B.
    3. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8. 
    3. Data Entry Instructions
    STATION
    NUMBER
    (STN-A)STATION
    NUMBER
    (STN-B)REMARKS
    TENANT
    NUMBER
    (TN-A)TENANT
    NUMBER
    (TN-B)
    TN-B and STN-B
     TN-B and STN-B (UCD pilot station number) parameters should be assigned 
    with respect to the data assigned by the ASHU command.
    TN-A and STN-A
     TN-A and STN-A (UCD pilot station number) parameters should be assigned 
    with respect to the data assigned by the ASHU command.
    ORIGINAL UCD GROUP OVERFLOW UCD GROUP 
    						
    							NDA-24298 CHAPTER 4
    Page 691
    Issue 1
    AUOG : Assignment of UCD Overflow Group
    4. Data Sheet
    ORIGINAL UCD GROUP OVERFLOW UCD GROUP
    REMARKS TENANT
    NUMBER
    (TN-A)STATION
    NUMBER
    (STN-A)TENANT
    NUMBER
    (TN-B)STATION
    NUMBER
    (STN-B) 
    						
    							CHAPTER 4 NDA-24298
    Page 692
    Issue 1
    AUOGL : Assignment of UCD Overflow Group for LDM
    AUOGL: Assignment of UCD Overflow Group for LDM
    1. General
    This command assigns the data related to the Overflow - UCD service feature for each Node by using Telephone
    Number. The data is written in Local Data Memory (LDM).
    2. Precautions
    1. The UCD member station and the UCD pilot (controlling station) station should be assigned by the
    ASHUL command.
    2. The calls terminate to the designated group can overflow (forward) to another UCD group. They overflow
    from UGN-A, TELN-A to UGN-B, TELN-B.
    3. Data Entry Instructions
    TELEPHONE
    NUMBER
    (TELN-A)TELEPHONE
    NUMBER
    (TELN-B) USER 
    GROUP
    NUMBER
    (UGN-A)USER 
    GROUP
    NUMBER
    (UGN-B)
    UGN-B and TELN-B
     UGN-B and TELN-B (UCD pilot station number) parameters should be assigned 
    with respect to the data assigned by the ASHUL command.
    UGN-A and TELN-A
     UGN-A and TELN-A (UCD pilot station number) parameters should be 
    assigned with respect to the data assigned by the ASHUL command.
    ORIGINAL UCD GROUP OVERFLOW UCD GROUP 
    						
    							NDA-24298 CHAPTER 4
    Page 693
    Issue 1
    AUOGL : Assignment of UCD Overflow Group for LDM
    4. Data Sheet
    ORIGINAL UCD GROUP OVERFLOW UCD GROUP
    USER 
    GROUP
    NUMBER
    (UGN-A)TELEPHONE
    NUMBER
    (TELN-A)USER 
    GROUP
    NUMBER
    (UGN-B)TELEPHONE
    NUMBER
    (TELN-B) 
    						
    							CHAPTER 4 NDA-24298
    Page 694
    Issue 1
    AUOGN : Assignment of UCD Overflow Group for NDM
    AUOGN: Assignment of UCD Overflow Group for NDM
    1. General
    This command assigns the data related to the Overflow - UCD for Fusion Service. The data assigned by this
    command is written in the Network Data Memory (NDM) of the Network Control Node (NCN), updating the
    NDM at each Local Node (LN).
    2. Precautions
    1. The UCD member station and the UCD pilot (controlling station) station should be assigned by the
    ASHUN command.
    2. The calls terminate to the designated group can overflow (forward) to another UCD group. They overflow
    from UGN-A, TELN-A to UGN-B, TELN-B.
    3. Data Entry Instructions
    TELEPHONE
    NUMBER
    (TELN-A)TELEPHONE
    NUMBER
    (TELN-B) USER 
    GROUP
    NUMBER
    (UGN-A)USER 
    GROUP
    NUMBER
    (UGN-B)
    UGN-B and TELN-B
     UGN-B and TELN-B (UCD pilot station number) parameters should be assigned 
    with respect to the data assigned by the ASHUN command.
    UGN-A and TELN-A
     UGN-A and TELN-A (UCD pilot station number) parameters should be 
    assigned with respect to the data assigned by the ASHUN command.
    ORIGINAL UCD GROUP OVERFLOW UCD GROUP 
    						
    							NDA-24298 CHAPTER 4
    Page 695
    Issue 1
    AUOGN : Assignment of UCD Overflow Group for NDM
    4. Data Sheet
    ORIGINAL UCD GROUP OVERFLOW UCD GROUP
    USER 
    GROUP
    NUMBER
    (UGN-A)TELEPHONE
    NUMBER
    (TELN-A)USER 
    GROUP
    NUMBER
    (UGN-B)TELEPHONE
    NUMBER
    (TELN-B) 
    						
    							CHAPTER 4 NDA-24298
    Page 696
    Issue 1
    AUAD : Assignment of UCD Delayed Announcement Data
    AUAD:  Assignment of UCD Delayed Announcement Data
    1. General
    This command assigns the data related to the Delay Announcement - UCD service feature.
    2. Precautions
    1. The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHU
    command.
    2. A maximum of eight (8) external announcement machines can be assigned per UCD group.
    3. As to the designation of sharing the UCD Announcement Information (ASYD SYS 1, INDEX 70, bit 6 :
    0/1 = Common/per UCD group), be sure to follow as mentioned below; 
    In case the system data (ASYD, SYS 1, INDEX 70, bit 6) shall be modified after the UCD
    Announcement Information has already been assigned, first clear all the data assigned by this command
    (AUAD), then the new data is to be reassigned.
    4. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.  
    						
    All NEC manuals Comments (0)