NEC Neax 2400 Ipx Office Data Specification
Have a look at the manual NEC Neax 2400 Ipx Office Data Specification online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
NDA-24298 CHAPTER 4 Page 307 Issue 1 AFRSN : Assignment of Flexible Route Selection Data for NDM 4. Data Sheet TENANT NUMBER (TN)LOGICAL ROUTE NUMBER (LGRT) 1-899NUMBER PATTERN CODE (NPC) MAX. 16 DIGITSOUTGOING ROUTE SELECTION NUMBER (OPR) 0 – 4000REMARKS
CHAPTER 4 NDA-24298 Page 308 Issue 1 AOPR : Assignment of Outgoing Pattern Routing Data AOPR: Assignment of Outgoing Pattern Routing Data 1. General This command assigns the LCR/LCRS routing pattern for each Outgoing Route Selection Pattern Routing (OPR) number. 2. Precautions 1. The OPR parameter corresponds to the one assigned by the AFRS command. 2. The TDPTN parameter is intermediate data to assign the ATCP command. The ATCP command is used to assign the time pattern. 3. The PNL parameter is intermediate data to assign the AADC command. The AADC command is used to assign the additional numbers to transmit. 4. The applicable number of additional digits (DC) by the AADC command varies depending on the PNL data. A maximum of 4 digits of DC is available when the PNL is assigned the range from 1 to 127, and the maximum of 24 digits of DC is available when the PNL is assigned the range from 128 to 999. 5. The E parameter is an indicator label of the RA. When E=1 is assigned, more RA assignments are required until E=0 has been assigned. 6. The overflow tone can be applied to the originating party if an alternate trunk route has been seized. The OVFT parameter designates whether the overflow tone is or is not provided. 7. The PRSC parameter is referred to as RSC2 of the AEFR command if the LCR-Controlled Alternate PRSC service is provided. Enter 0 (leave it blank) when the service is not required.
NDA-24298 CHAPTER 4 Page 309 Issue 1 AOPR : Assignment of Outgoing Pattern Routing Data 3. Data Entry Instructions Enter OPR assigned by the AFRS command.OPR Enter the trunk route seizure order.RA 0 = Route advance ends (Last route) 1 = -E Enter the number of digits to be skipped from dialed numbers.SKIP 0 = Overflow Tone is not provided 1 = Overflow Tone is provided 0 = LCR-Controlled Alternate PRSC service is not required 1-15 = The restriction class referred by the AEFR command.OVFT PRSC Enter data with a range from 0 to 7 if the Time Pattern assignment is required by the ATCP command, or the Clocked Manual Override data assigned by the ACMO command. Different TDPTN data can be assigned to a single OPR. 00 00 00 00 00 00 00 0 0 Enter data with a range from 1 to 999 if the digit addition is required by the AADC command. Otherwise, enter 0. A maximum of 4 digits of DC can be added when the PNL is assigned with a range from 1 to 127, and a maximum of 24 digits of DC can be added when the PNL data with a range from 128 to 999. TDPTN TIME OF DAY CHANGE PATTERN (TDPTN) 0-7OUTGOING ROUTE SELECTION PATTERN NUMBER (OPR) 0-4000ORDER OF ROUTE ADVANCING (RA) 0-7ROUTE ADVANCING END INDICATION (E) 0/1OUTSIDE ROUTE NUMBER (RT)NUMBER OF SKIPPED DIGITS (SKIP) 0-24PATTERN NUMBER LOCATION (PNL) 0-999OVERFLOW TONE (OVFT) 0/1PRIORITY RESTRICTION CLASS (PRSC) 0-15 PNLEnter the external trunk route number which is seized in the RA. The B-channel/voice channel route number should be entered in the case of ISDN/CCIS interface.RT REMARKS 111 1 112 21 1
CHAPTER 4 NDA-24298 Page 310 Issue 1 AOPR : Assignment of Outgoing Pattern Routing Data 4. Data Sheet TIME OF DAY CHANGE PATTERN (TDPTN) 0 – 7OUTGOING ROUTE SELECTION PATTERN NUMBER (OPR) 0 – 4000ORDER OF ROUTE ADVANCING (RA)ROUTE ADVANCING END INDICATION (E) 0/1OUTSIDE ROUTE NUMBER (RT) NUMBER OF SKIPPED DIGITS (SKIP) 0 – 24PATTERN NUMBER LOCATION (PNL) 0 – 999OV E R FL OW TONE (OVFT) 0/1PRIORITY RESTRICTION CLASS (PRSC) 0 – 15REMARKS 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
NDA-24298 CHAPTER 4 Page 311 Issue 1 AOPRL : Assignment of Outgoing Pattern Routing Data for LDM AOPRL: Assignment of Outgoing Pattern Routing Data for LDM 1. General This command assigns the LCR/LCRS routing pattern for each Outgoing Route Selection Pattern Routing (OPR) number. This command is required when LCR/LCRS activates via Fusion Link. 2. Precautions 1. The OPR parameter corresponds to the one assigned by the AFRSL command. 2. The TDPTN parameter is intermediate data to assign the ATCP command. The ATCP command is used to assign the time pattern. 3. The PNL parameter is intermediate data to assign the AADCL command. The AADCL command is used to assign the additional numbers to transmit. 4. The applicable number of additional digits (DC) by the AADCL command varies depending on the PNL data. A maximum of 4 digits of DC is available when the PNL is assigned the range from 1 to 127, and a maximum of 24 digits of DC is available when the PNL is assigned the range from 128 to 999. 5. The E parameter is an indicator label of the RA. When E=1 is assigned, more RA assignments are required until E=0 has been assigned. 6. The overflow tone can be applied to the originating party if an alternate trunk route has been seized. The OVFT parameter designates whether the overflow tone is or is not provided. 7. The PRSC parameter is referred to as RSC2 of the AEFR command if the LCR-Controlled Alternate PRSC service is provided. Enter 0 (leave it blank) when the service is not required.
CHAPTER 4 NDA-24298 Page 312 Issue 1 AOPRL : Assignment of Outgoing Pattern Routing Data for LDM 3. Data Entry Instructions Enter OPR assigned by the AFRSL command.OPR Enter the trunk route seizure order.RA 0 = Route advance ends (Last route) 1 = -EEnter the number of digits to be skipped from dialed numbers.SKIP 0 = Overflow Tone is not provided 1 = Overflow Tone is provided 0 = LCR-Controlled Alternate PRSC service is not required 1-15 = The restriction class referred by the AEFR commandOVFT PRSC Enter the Point Code of Destination Node only when data “1” is set in IPTRK parameter.PC Enter data with a range from 0 to 7 if the Time Pattern assignment is required by the ATCP command, or the Clocked Manual Override data assigned by the ACMO command. Different TDPTN data can be assigned to a single OPR. 00 00 00 00 00 00 00 0 0 Enter data with a range from 1 to 999 if the digit addition is required by the AADCL command. Otherwise, enter 0. A maximum of 4 digits of DC can be added when the PNL is assigned with a range from 1 to 127, and a maximum of 24 digits of DC can be added when the PNL data with a range from 128 to 999. TDPTN TIME OF DAY CHANGE PATTERN (TDPTN) 0-7OUTGOING ROUTE SELECTION PATTERN NUMBER (OPR) 0-4000ORDER OF ROUTE ADVANCING (RA) 0-7ROUTE ADVANCING END INDICATION (E) 0/1LOGICAL ROUTE NUMBER (LGRT) 1-899NUMBER OF SKIPPED DIGITS (SKIP) 0-24IP TRUNK (IPTRK) 0/1 NotePOINT CODE (PC) 1-16367 Note PATTERN NUMBER LOCATION (PNL) 0-999OVERFLOW TONE (OVFT) 0/1PRIORITY RESTRICTION CLASS (PRSC) 0-15 PNLEnter the Logical Route number which is seized in the RA. The B-channel/voice channel route number should be entered in the case of ISDN/CCIS interface.LGRT 111 1 112 21 1 0 = IP network is not used 1 = IP network is usedIPTRK Note:Parameters IPTRK and PC are available since Release 9 software enhancement.
NDA-24298 CHAPTER 4 Page 313 Issue 1 AOPRL : Assignment of Outgoing Pattern Routing Data for LDM 4. Data Sheet TIME OF DAY CHANGE PATTERN (TDPTN) 0 – 7OUTGOING ROUTE SELECTION PATTERN NUMBER (OPR) 0 – 4000ORDER OF ROUTE ADVANCING (RA)ROUTE ADVANCING END INDICATION (E) 0/1LOGICAL ROUTE NUMBER (LGRT) 1-899NUMBER OF SKIPPED DIGITS (SKIP) 0 – 24PATTERN NUMBER LOCATION (PNL) 0 – 999OVERFLOW TO NE (OVFT) 0/1PRIORITY RESTRICTION CLASS (PRSC) 0 – 15IP TRUNK (IPTRK) 0/1POINT CODE (PC) 1-16367 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
CHAPTER 4 NDA-24298 Page 314 Issue 1 AOPRN : Assignment of Outgoing Pattern Routing Data for NDM AOPRN: Assignment of Outgoing Pattern Routing Data for NDM 1. General This command assigns the LCR/LCRS routing pattern for each Outgoing Route Selection Pattern Routing (OPR) number. This command is required when LCR/LCRS activates via Fusion Networking link. The data as- signed by this command is written in the Network Data Memory (NDM) of the Network Control Node (NCN), updating the NDM at each Local Node (LN). 2. Precautions 1. The OPR parameter corresponds to the one assigned by the AFRSN command. 2. The TDPTN parameter is intermediate data to assign the ATCP command. The ATCP command is used to assign the time pattern. 3. The PNL parameter is intermediate data to assign the AADCN command. The AADCN command is used to assign the additional numbers to transmit. 4. The applicable number of additional digits (DC) by the AADCN command varies depending on the PNL data. A maximum of 4 digits of DC is available when the PNL is assigned the range from 1 to127, and a maximum of 24 digits of DC is available when the PNL is assigned the range from 128 to 999. 5. The E parameter is an indicator label of the RA. When E=1 is assigned, more RA assignments are required until E=0 has assigned. 6. The overflow tone can be applied to the originating party if an alternate trunk route has been seized. The OVFT parameter designates whether the overflow tone is or is not provided. 7. The PRSC parameter is referred to as RSC2 of the AEFR command if the “LCR-Controlled Alternate PRSC service is provided. Enter 0 (leave it blank) when the service is not required.
NDA-24298 CHAPTER 4 Page 315 Issue 1 AOPRN : Assignment of Outgoing Pattern Routing Data for NDM 3. Data Entry Instructions Enter OPR assigned by the AFRSN command.OPR Enter the trunk route seizure order.RA 0 = Route advance ends (Last route) 1 = -EEnter the number of digits to be skipped from dialed numbers.SKIP 0 = Overflow Tone is not provided 1 = Overflow Tone is provided 0 = LCR-Controlled Alternate PRSC service is not required 1-15 = The restriction class referred by the AEFR commandOVFT PRSC Enter the Point Code of Destination Node only when data “1” is set in IPTRK parameter.PC Enter data with a range from 0 to 7 if the Time Pattern assignment is required by the ATCP command, or the Clocked Manual Override data assigned by the ACMO command. 00 00 00 00 00 00 00 0 0 Enter data with a range from 1 to 999 if the digits addition is required by the AADCN command. Otherwise, enter 0. A maximum of 4 digits of DC can be added when the PNL is assigned with a range from 1 to 127, and a maximum of 24 digits of DC can be added when the PNL data with a range from 128 to 999. TDPTN TIME OF DAY CHANGE PATTERN (TDPTN) 0-7OUTGOING ROUTE SELECTION PATTERN NUMBER (OPR) 0-4000ORDER OF ROUTE ADVANCING (RA) 0-7ROUTE ADVANCING END INDICATION (E) 0/1LOGICAL ROUTE NUMBER (LGRT) 1-899NUMBER OF SKIPPED DIGITS (SKIP) 0-24IP TRUNK (IPTRK) 0/1 NotePOINT CODE (PC) 1-16367 PATTERN NUMBER LOCATION (PNL) 0-999OVERFLOW TONE (OVFT) 0/1PRIORITYRESTRICTIONCLASS (PRSC) 0-15 PNLEnter the Logical Route number which is seized in the RA. The B-channel/voice channel route number should be entered in the case of ISDN/CCIS interface.LGRT 111 1 112 21 1 0 = IP network is not used 1 = IP network is usedIPTRK Note:Parameters IPTRK and PC are available since Release 9 software enhancement. Note
CHAPTER 4 NDA-24298 Page 316 Issue 1 AOPRN : Assignment of Outgoing Pattern Routing Data for NDM 4. Data Sheet TIME OF DAY CHANGE PATTERN (TDPTN) 0 – 7OUTGOING ROUTE SELECTION PATTERN NUMBER (OPR) 0 – 4000ORDER OF ROUTE ADVANCING (RA)ROUTE ADVANCING END INDICATION (E) 0/1LOGICAL ROUTE NUMBER (LGRT) 1-899NUMBER OF SKIPPED DIGITS (SKIP) 0 – 24PATTERN NUMBER LOCATION (PNL) 0 – 999OVERFLOW TO NE (OVFT) 0/1PRIORITY RESTRICTION CLASS (PRSC) 0 – 15IP TRUNK (IPTRK) 0/1POINT CODE (PC) 1-16367 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7