NDA-24298 CHAPTER 4 Page 677 Issue 1 ASHUL : Assignment of Station Hunting Group-UCD for LDM 4. Data Sheet USER GROUP NUMBER (UGN)TELEPHONE NUMBER (TELN) NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN)NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN)NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN)NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN) 2 275277 3 285378 4 295479 5 305580 6 315681 7 325782 8 335883 9 345984 10 35 60 85 11 36 61 86 12 37 62 87 13 38 63 88 14 39 64 89 15 40 65 90 16 41 66 91 17 42 67 92 18 43 68 93 19 44 69 94 20 45 70 95 21 46 71 96 22 47 72 97 23 48 73 98 24 49 74 99 25 50 75 100 26 51 76
CHAPTER 4 NDA-24298 Page 678 Issue 1 ASHUN : Assignment of Station Hunting Group-UCD for NDM ASHUN: Assignment of Station Hunting Group-UCD for NDM 1. General This command assigns the data related to the Uniform Call Distribution (UCD) for Fusion Service. The data assigned by this command is written in the Network Data Memory (NDM) of the Network Control Node (NCN), updating the NDM at each Local Node (LN). 2. Precautions 1. This command is also used to modify and delete the UCD service related data. 2. The maximum number of stations within a UCD group is 100. 3. The UCD pilot station (controlling station) is assigned at the TELN parameter. 4. Press ESC to skip forward to the WRT? text box when all the desired stations have been entered. 5. Assign the AUADN command if the Delay Announcement-UCD service feature is required. 6. Assign the AUCDN command if the peripheral threshold listed below is required: (a) The number of call in UCD queuing which is used for the UCD Peg Count (b) The threshold of the UCD Call Waiting Lamp (which can be accommodated on a D term) starts to flash (c) Denial of the MCI call result text of the call terminated to the UCD group 7. Assign AUOGN command if the Overflow-UCD service feature is required. 8. When assigning the AUADN/AUCDN/AUOGN commands, the User Group Number (UGN) and the UCD Pilot station (controlling station) number (TELN) assigned in this command are used to specify the UCD group.
NDA-24298 CHAPTER 4 Page 679 Issue 1 ASHUN : Assignment of Station Hunting Group-UCD for NDM 3. Data Entry Instructions Note:Enter the Telephone Number to be assigned in “EDIT TELN” box on the display. NUMBER OF STATIONS (CNT)NUMBER OF STATIONS (CNT) USER GROUP NUMBER (UGN)TELEPHONE NUMBER (TELN) Max.16 digits TELN TELN TELN TELNNUMBER OF STATIONS (CNT)NUMBER OF STATIONS (CNT) TELEPHONE NUMBER (TELN) Fixed to 1UGN 2 3 4 527 28 29 3052 53 54 5577 78 79 80 TELN Enter UCD pilot station (controlling station). 1
CHAPTER 4 NDA-24298 Page 680 Issue 1 ASHUN : Assignment of Station Hunting Group-UCD for NDM 4. Data Sheet USER GROUP NUMBER (UGN)TELEPHONE NUMBER (TELN) NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN)NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN)NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN)NUMBER OF STATIONS (CNT)TELEPHONE NUMBER (TELN) 2 275277 3 285378 4 295479 5 305580 6 315681 7 325782 8 335883 9 345984 10 35 60 85 11 36 61 86 12 37 62 87 13 38 63 88 14 39 64 89 15 40 65 90 16 41 66 91 17 42 67 92 18 43 68 93 19 44 69 94 20 45 70 95 21 46 71 96 22 47 72 97 23 48 73 98 24 49 74 99 25 50 75 100 26 51 76
NDA-24298 CHAPTER 4 Page 681 Issue 1 AUCD : Assignment of UCD Control Data AUCD: Assignment of UCD Control Data 1. General This command assigns the miscellaneous data related to the Uniform Call Distribution (UCD) service feature. 2. Precautions 1. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8. 2. The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHU command. 3. This command can be specified using the following UCD related options: (a) The number of calls in UCD queuing which is used for the UCD Peg Count (b) The threshold of the UCD Call Waiting Lamp (which is accommodated on a D term) starts to flash (c) Denial of the MCI call result text of the call terminated to the UCD group 4. The following data should also be assigned for UCD - Call Waiting lamp flashing: ASYD command, SYS1, INDEX 61, b5 = 1 (Call Waiting Display-UCD in Service) AKYD command, FKY=47 (UCD Call Waiting Lamp) 5. After the data assignment, the line circuit card which contains the UCD group stations must be initialized (turn the MB key ON/OFF).
CHAPTER 4 NDA-24298 Page 682 Issue 1 AUCD : Assignment of UCD Control Data 3. Data Entry Instructions Enter the number of calls in the UCD queue. (This value is used for UCD Peg Count.)QTH Enter the number of calls in the UCD queue. (This value is used for UCD Call Waiting Lamp on Dterm). CWT STATION NUMBER (STN)UCD QUEUING PEG COUNT VALUE (QTH ACT) 0/1UCD QUEUING PEG COUNT VALUE (QTH ) 0-255THRESHOLD VALUE OF CALL WAITING (CWT) 1-255MCI DATA TRANSFER (MCI) 0/1REMARKS TENANT NUMBER (TN) TN and STN QTH ACT UCD queuing value (used for Peg Count) is: 0 = Invalid (QTH parameter is not assigned) 1 = Valid (QTH parameter is assigned)MCI The call record to the UCD group is transferred to MCI 0 = Valid 1 = Invalid TN and STN (UCD pilot station number) parameter should be assigned with respect to the data assigned by the ASHU command.
NDA-24298 CHAPTER 4 Page 683 Issue 1 AUCD : Assignment of UCD Control Data 4. Data Sheet TENANT NUMBER (TN)STATION NUMBER (STN)UCD QUEUING PEG COUNT VALUE (QTH ACT) 0/1UCD QUEUING PEG COUNT VALUE (QTH) 0-255THRESHOLD VALUE OF CALL WAITING (CWT) 1-255MCI DATA TRANSFER (MCI) 0/1REMARKS
CHAPTER 4 NDA-24298 Page 684 Issue 1 AUCDL : Assignment of UCD Control Data for LDM AUCDL: Assignment of UCD Control Data for LDM 1. General This command assigns the miscellaneous data related to the Uniform Call Distribution (UCD) service feature for each Node by using Telephone Number. The data is written in Local Data Memory (LDM). 2. Precautions 1. The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHUL command. 2. This command is used to specify the following UCD related options: (a) The number of calls in UCD queuing which is used for the UCD Peg Count. (b) The threshold of the UCD Call Waiting Lamp (which is accommodated on a D term) starts to flash. (c) Denial of the MCI call result text of the call terminated to the UCD group. 3. The following data should also be assigned for UCD - Call Waiting lamp flashing: ASYD command, SYS1, INDEX 61, b5 = 1 (Call Waiting Display-UCD in Service) AKYD command, FKY = 47 (UCD Call Waiting Lamp) 4. After the data assignment, the line circuit card which contains the UCD group stations must be initialized (turn the MB key ON/OFF).
NDA-24298 CHAPTER 4 Page 685 Issue 1 AUCDL : Assignment of UCD Control Data for LDM 3. Data Entry Instructions Enter the number of calls in the UCD queue. (This value is used for UCD Peg Count.)QTH Enter the number of calls in the UCD queue. (This value is used for UCD Call Waiting Lamp on Dterm) CWT UCD QUEUING PEG COUNT VALUE (QTH ACT) 0/1UCD QUEUING PEG COUNT VALUE (QTH ) 0-255THRESHOLD VALUE OF CALL WAITING (CWT) 1-255MCI DATA TRANSFER (MCI) 0/1 USER GROUP NUMBER (UGN) UGN and TELN QTH ACT UCD queuing value (used for Peg Count) is: 0 = Invalid (QTH parameter is not assigned) 1 = Valid (QTH parameter is assigned)MCI The call record to the UCD group is transferred to MCI 0 = Valid 1 = Invalid UGN and TELN (UCD pilot station number) parameters should be assigned with respect to the data assigned by the ASHUL command. TELEPHONE NUMBER (TELN) 16 digits maximum
CHAPTER 4 NDA-24298 Page 686 Issue 1 AUCDL : Assignment of UCD Control Data for LDM 4. Data Sheet USER GROUP NUMBER (UGN)TELEPHONE NUMBER (TELN) 16 digits maximumUCD QUEUING PEG COUNT VA L U E (QTH ACT) 0/1UCD QUEUING PEG COUNT VA L U E (QTH) 0-255THRESHOLD VALUE OF CALL WAITING (CWT) 1-255MCI DATA TRANSFER (MCI) 0/1