NDA-24298 CHAPTER 4 Page 137 Issue 1 ASYD : Assignment of System Data 1200 b0LP08 #0 is mounted on PBI40 Module for IPX-UMG system b1LP08 #1 is mounted on PBI40 Module for IPX-UMG system 0 b2Not used 0b3 b4LP10 #0 is mounted on PBI44 Module for IPX-UMG system b5LP10 #1 is mounted on PBI44 Module for IPX-UMG system 0 b6Not used 0b7 201 b0LP12 #0 is mounted on PBI48 Module for IPX-UMG system b1LP12 #1 is mounted on PBI48 Module for IPX-UMG system 0 b2Not used 0b3 b4LP14 #0 is mounted on PBI4C Module for IPX-UMG system b5LP14 #1 is mounted on PBI4C Module for IPX-UMG system 0 b6Not used 0b7 202 b0LP16 #0 is mounted on PBI50 Module for IPX-UMG system b1LP16 #1 is mounted on PBI50 Module for IPX-UMG system 0 b2Not used 0b3 b4LP18 #0 is mounted on PBI54 Module for IPX-UMG system b5LP18 #1 is mounted on PBI54 Module for IPX-UMG system 0 b6Not used 0b7 203 b0LP20 #0 is mounted on PBI58 Module for IPX-UMG system b1LP20 #1 is mounted on PBI58 Module for IPX-UMG system 0 b2Not used 0b3 b4LP22 #0 is mounted on PBI5C Module for IPX-UMG system b5LP22 #1 is mounted on PBI5C Module for IPX-UMG system 0 b6Not used 0b7 204 b0LP24 #0 is mounted on PBI60 Module for IPX-UMG system b1LP24 #1 is mounted on PBI60 Module for IPX-UMG system 0 b2Not used 0b3 b4LP26 #0 is mounted on PBI64 Module for IPX-UMG system b5LP26 #1 is mounted on PBI64 Module for IPX-UMG system 0 b6Not used 0b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 138 Issue 1 ASYD : Assignment of System Data 1205 b0LP28 #0 is mounted on PBI68 Module for IPX-UMG system b1LP28 #1 is mounted on PBI68 Module for IPX-UMG system 0 b2Not used 0b3 b4LP30 #0 is mounted on PBI6C Module for IPX-UMG system b5LP30 #1 is mounted on PBI6C Module for IPX-UMG system 0 b6Not used 0b7 206 00Not used 207 b0IP00 System #0 0/1 = Not mounted/Mounted b1IP00 System #1 0/1 = Not mounted/Mounted b2IP01 System #0 0/1 = Not mounted/Mounted b3IP01 System #1 0/1 = Not mounted/Mounted b4IP02 System #0 0/1 = Not mounted/Mounted b5IP02 System #1 0/1 = Not mounted/Mounted b6Not used b7Not used 208 00 Not used 209 b0Processor Bus No. 0 (Usually assign as “1”.)Processor Bus Indication (for IPX-UMG system). 0 = Not Mounted 1 = Mounted b1Processor Bus No. 1 (Usually assign as “1”.) 0 b2~b6Not used 1 b7 If both TSWs in MG are defective, the following functions are activated: PFT service TSW Fault Message Output Automatic Recover of TSW 0/1 = Not Required/Required SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 139 Issue 1 ASYD : Assignment of System Data 1210 00 Not used 213 00 Not used 214 00 b0 Not used b1 b2 b3 b4 b5Node Suppression - Centralized Billing CCIS 0/1 = Out/In Service b6Not usedb7 215 00Not used 219 00Not used 220 b0Protocol of ISDN Terminal (BRI station) 0:Japan (INS64) 1:U.S.A. (5ESS) 2:Australia (TPH 1962) 3:Not used 4:Not used 5:N-ISDN1 6-15:Not used b1 b2 b3 b4Rate Adaption (RA) for ISDN Terminal 0: RA designated by ADA2 command 1: V.110/X.30 2: Not used 3: Not used b5 0b6ISDN service (When Index 186 bit6 = 1) 0/1 = In Service/Out of Service b7 ISDN Trunk Layer3 Timer 0/1 = Stop/Activate Note:Normally assign “0. (Only specific service needs data “1” in this bit.) Related Layer3 Timer: T303, T310, T313. 221 00 Not used 228 00Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT ~ ~ ~ ~ ~ ~ ~ ~ ~
CHAPTER 4 NDA-24298 Page 140 Issue 1 ASYD : Assignment of System Data 1229 000 b0 Disable Attendant Console Loop keys when that console is in Night Mode (Nite Key engaged) 0/1 = No/Yes 0 b1Not used b2 With the key pad pressed by the Attendant while talking with the incoming call, DTMF (PB) signal is sent out to the incoming call. 0/1 = Not Required/Required b3Day/Night Change Message Automatic Output. 0/1 = Out/In Service 0 b4 Not usedb5 b6 b7 230b0~b6Not used b7Receive/Send timing for ISDN/CCIS message 0/1 = 32ms/128ms 231 00 Not used 232 b0Call Forward All Clear 0/1 = No/Yes Used in conjunction with Indexes 89 and 90 b1Call Forward Busy Clear 0/1 = No/Yes b2Call Forward No Answer Clear 0/1 = No/Yes b3 Not used b4 b5 b6 b7 233 00Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
NDA-24298 CHAPTER 4 Page 141 Issue 1 ASYD : Assignment of System Data 1234 b0Connection acknowledge polarity reversal signal 0/1 = Not Required/Required (Multi-Frequency) 0 b1 Not used b2 b3 b4 b5 b6 b7 235 00Not used 236 00 Not used 2370 b0-b6Not used b7When a call terminated to vacant number by Direct Inward Dialing 0/1 = Send Busy Tone/Reorder Tone 238 00 Not used 239 00 Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 142 Issue 1 ASYD : Assignment of System Data 1 2400 b0 Not used 0b1 0b2 0b3 b4 This bit defines the meaning of the “Station Information” in the office that has VMS/Host Computer within the CCIS No. 7 Network. 0 = Station Information = Office Code + Station Number 1 = Station Information = Station Number Note:Station Information corresponds to Mail Box in VMS Office Code indicates the self office code assigned by ARNP. Example: Pattern 1STAMail Box Number 1000 2000 3000 In case of pattern 1, b 4 is 1 Pattern 2STAMail Box Number 61000 72000 83000 In case of pattern 2, b 4 is 0. b5-b6Not used b7 The Kind of tone after dialing Remote Access number for Remote Access to System 0/1: SST /SPDT SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT Office Code: 8 Office Code: 6 Office Code: 7PBX PBXPBXVMS CCIS CCIS STN 3000 STN 2000STN 1000
NDA-24298 CHAPTER 4 Page 143 Issue 1 ASYD : Assignment of System Data 1241 b0Data Port Chime Control by SCF 0/1 = To be controlled/Not to be controlled b1The number of digits displayed in Name Display Service 0/1 = 8 digits/16 digits b2OAI Call Event Process 0/1 = No/Yes b3Detail Information on SCG error 0/1 = No/Yes b4MF ANI on SMDR 0/1 = No/Yes b5Privacy Release for single line 0/1 = No/Yes b6When the length of Caller ID exceeds the limit: 0/1 = Only the former/latter part of data appears on the LCD b7Not used 242 b0Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0 – 15).Timer for Delay Announcement – Attendant (Duration of RBT) Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is auto- matically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec. 111=– b5 b6 b7Not used 243 00 Ans. timer for transfer trunk. Same format as 242. The default is 64 sec SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 144 Issue 1 ASYD : Assignment of System Data 1244 b0 Answer by Radio Paging answer code. 0/1 = Out/In Service Note:This bit is valid when SYS-1, INDEX 73, Bit 4 is 1 (= Station Number is Automatically sent). 0 b1 Not used b2MCI-CCIS output packet change when the last digit is “*.” 0/1 = -/route number and trunk number are output 0 b3 , b4Not used b5 Timing of providing the announcement for Delay Announcement -Attendant 0 = immediately after the call termination 1 = after the ring back tone (SYS1, INDEX242) b6 Hooking operation during 3-party conference call; 0 = - 1 = Hooking operation is invalid Note:This data is available since Release 9 software. 0 b7Not used 245 b0Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0– 15). Timer for Delay Announcement – Attendant (Duration of Music on Hold) Note:When this data is 00 Hex, default data is auto- matically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=– b5 b6 b7Not used SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1ST. 2ND. ONE
NDA-24298 CHAPTER 4 Page 145 Issue 1 ASYD : Assignment of System Data 1246 b0 While engaging in a two-party call with a station/trunk, the Attendant places the call on hold by pressing either the ANSWER key or the Incoming Call Identification (ICI) key and answers the next call. 0/1 = Not Available/Available b1 While engaging in a three-way call with station/trunks, the Attendant exits from the call by depressing either ANSWER key or ICI key and answers an incoming call terminated next. 0/1 = Not Available/Available 0 b2Attendant Delay Announcement 0/1= Multiple Playback/Single Playback b3MCI Expansion 0/1 = Normal/Expanded b4 Process of incoming calls (Ring Down), after they encounter their 1st and 2nd receiver time-out, in a sequence of Automated Attendant 0/1 = Forced Release/Transfer to ATT b5Expanded 911 service 0/1 = No/Yes b6OAS Message Type 0/1 = Normal/IBM Call Path b7 247 b0 ~ b3 Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0~15)No Answer Timer for Blind Transfer- station Timer Value Setting is MTC × TC sec. Note:When this data is 00 hex, default data is auto- matically set to 30 sec. b4 ~ b7 Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=8 sec. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 NDA-24298 Page 146 Issue 1 ASYD : Assignment of System Data Note 1:When this data has been set as specified below, the alarm message output value becomes 80% and the alarm message output clear message output value becomes 50% regardless of the data. When the data of INDEX 249 is smaller than or equal to the data of INDEX 250 When these data values are not valid. 12480 b0 ~ b3Not used b4Call Forward Don’t Answer After Attendant Camp-On 0/1 = No/Yes b5Not used b6 When the destination station has been set Call Forwarding - Don’t Answer 0 = Recall to the station 1 = C.F. – Don’t Answer is activated. Note:Available for software Release 9 or later. b7 Tone to be sent out when the handset is off-hook at the station on which C.F. – All Calls service is set. 0/1 = Dial Tone (DT)/Special Dial Tone (SPDT) 249 b0 ~ b7 SMDR output buffer usage rate (01–99%) at the time of output of SMDR Buffer Overflow Alarm message (System Message 6-O) Note 1 Example: Indicates that the usage rate has been set to 80%. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT b7b6b5b4b3b2b1b0 Unit Tens b7b6b5b4b3b2b1b0 80 10 000 000