    							NDA-24298 CHAPTER 4
    Page 137
    Issue 1
    ASYD : Assignment of System Data
    1200
    b0LP08 #0 is mounted on PBI40 Module for IPX-UMG system
    b1LP08 #1 is mounted on PBI40 Module for IPX-UMG system
    0
    b2Not used
    0b3
    b4LP10 #0 is mounted on PBI44 Module for IPX-UMG system
    b5LP10 #1 is mounted on PBI44 Module for IPX-UMG system
    0
    b6Not used
    0b7
    201
    b0LP12 #0 is mounted on PBI48 Module for IPX-UMG system
    b1LP12 #1 is mounted on PBI48 Module for IPX-UMG system
    0
    b2Not used
    0b3
    b4LP14 #0 is mounted on PBI4C Module for IPX-UMG system
    b5LP14 #1 is mounted on PBI4C Module for IPX-UMG system
    0
    b6Not used
    0b7
    202
    b0LP16 #0 is mounted on PBI50 Module for IPX-UMG system
    b1LP16 #1 is mounted on PBI50 Module for IPX-UMG system
    0
    b2Not used
    0b3
    b4LP18 #0 is mounted on PBI54 Module for IPX-UMG system
    b5LP18 #1 is mounted on PBI54 Module for IPX-UMG system
    0
    b6Not used
    0b7
    203
    b0LP20 #0 is mounted on PBI58 Module for IPX-UMG system
    b1LP20 #1 is mounted on PBI58 Module for IPX-UMG system
    0
    b2Not used
    0b3
    b4LP22 #0 is mounted on PBI5C Module for IPX-UMG system
    b5LP22 #1 is mounted on PBI5C Module for IPX-UMG system
    0
    b6Not used
    0b7
    204
    b0LP24 #0 is mounted on PBI60 Module for IPX-UMG system
    b1LP24 #1 is mounted on PBI60 Module for IPX-UMG system
    0
    b2Not used
    0b3
    b4LP26 #0 is mounted on PBI64 Module for IPX-UMG system
    b5LP26 #1 is mounted on PBI64 Module for IPX-UMG system
    0
    b6Not used
    0b7
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 138
    Issue 1
    ASYD : Assignment of System Data 
    1205
    b0LP28 #0 is mounted on PBI68 Module for IPX-UMG system
    b1LP28 #1 is mounted on PBI68 Module for IPX-UMG system
    0
    b2Not used
    0b3
    b4LP30 #0 is mounted on PBI6C Module for IPX-UMG system
    b5LP30 #1 is mounted on PBI6C Module for IPX-UMG system
    0
    b6Not used
    0b7
    206 00Not used
    207
    b0IP00 System #0
    0/1 = Not mounted/Mounted
    b1IP00 System #1
    0/1 = Not mounted/Mounted
    b2IP01 System #0
    0/1 = Not mounted/Mounted
    b3IP01 System #1
    0/1 = Not mounted/Mounted
    b4IP02 System #0
    0/1 = Not mounted/Mounted
    b5IP02 System #1
    0/1 = Not mounted/Mounted
    b6Not used
    b7Not used
    208 00
    Not used
    209
    b0Processor Bus No. 0
    (Usually assign as “1”.)Processor Bus 
    Indication (for 
    IPX-UMG 
    system).
    0 = Not Mounted
    1 = Mounted
    b1Processor Bus No. 1
    (Usually assign as “1”.)
    0
    b2~b6Not used
    1
    b7
    If both TSWs in MG are defective, the following functions are 
    activated:
    PFT service
    TSW Fault Message Output
    Automatic Recover of TSW
    0/1 = Not Required/Required
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 139
    Issue 1
    ASYD : Assignment of System Data
    1210 00
    Not used
    213 00
    Not used
    214 00
    b0
    Not used
    b1
    b2
    b3
    b4
    b5Node Suppression - Centralized Billing CCIS
    0/1 = Out/In Service
    b6Not usedb7
    215 00Not used
    219 00Not used
    220
    b0Protocol of ISDN Terminal (BRI station)
    0:Japan (INS64)
    1:U.S.A. (5ESS)
    2:Australia (TPH 1962)
    3:Not used
    4:Not used
    5:N-ISDN1
    6-15:Not used
    b1
    b2
    b3
    b4Rate Adaption (RA) for ISDN Terminal
    0: RA designated by ADA2 command
    1: V.110/X.30
    2: Not used
    3: Not used
    b5
    0b6ISDN service (When Index 186 bit6 = 1)
    0/1 = In Service/Out of Service
    b7
    ISDN Trunk Layer3 Timer
    0/1 = Stop/Activate
    Note:Normally assign “0. (Only specific service needs data
    “1” in this bit.) Related Layer3 Timer: T303, T310,
    T313.
    221 00
    Not used
    228 00Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    ~
    ~
    ~
    ~ ~
    ~ ~
    ~
    ~ 
    						
    							CHAPTER 4 NDA-24298
    Page 140
    Issue 1
    ASYD : Assignment of System Data 
    1229 000
    b0
    Disable Attendant Console Loop keys when that console is in 
    Night Mode (Nite Key engaged)
    0/1 = No/Yes
    0
    b1Not used
    b2
    With the key pad pressed by the Attendant while talking with the 
    incoming call, DTMF (PB) signal is sent out to the incoming call.
    0/1 = Not Required/Required
    b3Day/Night Change Message Automatic Output.
    0/1 = Out/In Service
    0
    b4
    Not usedb5
    b6
    b7
    230b0~b6Not used
    b7Receive/Send timing for ISDN/CCIS message
    0/1 = 32ms/128ms
    231 00
    Not used
    232
    b0Call Forward All Clear
    0/1 = No/Yes
    Used in 
    conjunction with 
    Indexes 89 and 90
    b1Call Forward Busy Clear
    0/1 = No/Yes
    b2Call Forward No Answer Clear
    0/1 = No/Yes
    b3
    Not used
    b4
    b5
    b6
    b7
    233 00Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							NDA-24298 CHAPTER 4
    Page 141
    Issue 1
    ASYD : Assignment of System Data
    1234
    b0Connection acknowledge polarity reversal signal
    0/1 = Not Required/Required (Multi-Frequency)
    0
    b1
    Not used
    b2
    b3
    b4
    b5
    b6
    b7
    235 00Not used
    236 00
    Not used
    2370
    b0-b6Not used
    b7When a call terminated to vacant number by Direct Inward Dialing
    0/1 = Send Busy Tone/Reorder Tone
    238 00
    Not used
    239 00
    Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 142
    Issue 1
    ASYD : Assignment of System Data 
    1 2400
    b0
    Not used 0b1
    0b2
    0b3
    b4
    This bit defines the meaning of the “Station Information” in the 
    office that has VMS/Host Computer within the CCIS No. 7 
    Network.
    0 = Station Information = Office Code + Station Number
    1 = Station Information = Station Number
    Note:Station Information corresponds to Mail Box in VMS
    Office Code indicates the self office code assigned by
    ARNP.
    Example:
    Pattern 1STAMail Box Number
    1000
    2000
    3000
    In case of pattern 1, b
    4 is 1
    Pattern 2STAMail Box Number
    61000
    72000
    83000
    In case of pattern 2, b
    4 is 0.
    b5-b6Not used
    b7
    The Kind of tone after dialing Remote Access number for Remote 
    Access to System
    0/1: SST /SPDT
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    Office Code: 8 Office Code: 6
    Office Code: 7PBX
    PBXPBXVMS CCIS
    CCIS STN
    3000
    STN
    2000STN
    1000 
    						
    							NDA-24298 CHAPTER 4
    Page 143
    Issue 1
    ASYD : Assignment of System Data
    1241
    b0Data Port Chime Control by SCF
    0/1 = To be controlled/Not to be controlled
    b1The number of digits displayed in Name Display Service
    0/1 = 8 digits/16 digits
    b2OAI Call Event Process
    0/1 = No/Yes
    b3Detail Information on SCG error
    0/1 = No/Yes
    b4MF ANI on SMDR
    0/1 = No/Yes
    b5Privacy Release for single line
    0/1 = No/Yes
    b6When the length of Caller ID exceeds the limit:
    0/1 = Only the former/latter part of data appears on the LCD
    b7Not used
    242
    b0Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex
    (0 – 15).Timer for Delay 
    Announcement – 
    Attendant 
    (Duration of RBT)
    Timer Value 
    Setting is MTC 
    × 
    TC sec.
    Note:When this 
    data is 00 
    Hex, default 
    data is auto-
    matically 
    set to 30 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of the 
    following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec. 111=–
    b5
    b6
    b7Not used
    243 00
    Ans. timer for transfer trunk.
    Same format as 242. The default is 64 sec
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 144
    Issue 1
    ASYD : Assignment of System Data 
    1244
    b0
    Answer by Radio Paging answer code.
    0/1 = Out/In Service
    Note:This bit is valid when SYS-1, INDEX 73, Bit 4 is 1 (=
    Station Number is Automatically sent).
    0
    b1 Not used
    b2MCI-CCIS output packet change when the last digit is “*.”
    0/1 = -/route number and trunk number are output
    0
    b3 , b4Not used
    b5
    Timing of providing the announcement for Delay Announcement
    -Attendant
    0 = immediately after the call termination
    1 = after the ring back tone (SYS1, INDEX242)
    b6 
    Hooking operation during 3-party conference call;
    0 = -
    1 = Hooking operation is invalid
    Note:This data is available since Release 9 software.
    0
    b7Not used
    245
    b0Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex (0–
    15).
    Timer for Delay 
    Announcement – 
    Attendant 
    (Duration of Music 
    on Hold)
    Note:When this 
    data is 00 
    Hex, default 
    data is auto-
    matically 
    set to 30 sec.
    b1
    b2
    b3
    b4Timer Class (TC) is to be assigned one of the 
    following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=–
    b5
    b6
    b7Not used
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1ST. 2ND.
    ONE 
    						
    							NDA-24298 CHAPTER 4
    Page 145
    Issue 1
    ASYD : Assignment of System Data
    1246
    b0
    While engaging in a two-party call with a station/trunk, the 
    Attendant places the call on hold by pressing either the ANSWER 
    key or the Incoming Call Identification (ICI) key and answers the 
    next call.
    0/1 = Not Available/Available
    b1
    While engaging in a three-way call with station/trunks, the 
    Attendant exits from the call by depressing either ANSWER key 
    or ICI key and answers an incoming call terminated next.
    0/1 = Not Available/Available
    0
    b2Attendant Delay Announcement
    0/1= Multiple Playback/Single Playback
    b3MCI Expansion
    0/1 = Normal/Expanded
    b4
    Process of incoming calls (Ring Down), after they encounter their 
    1st and 2nd receiver time-out, in a sequence of Automated 
    Attendant
    0/1 = Forced Release/Transfer to ATT
    b5Expanded 911 service
    0/1 = No/Yes
    b6OAS Message Type
    0/1 = Normal/IBM Call Path
    b7
    247
    b0 ~ b3
    Miscellaneous Timer Counter (MTC) is to 
    be assigned a value from 0 Hex to F Hex 
    (0~15)No Answer Timer 
    for Blind Transfer-
    station
    Timer Value 
    Setting is MTC 
    × 
    TC sec.
    Note:When this 
    data is 00 
    hex, default 
    data is auto-
    matically 
    set to 30 sec.
    b4 ~ b7
    Timer Class (TC) is to be assigned one of the 
    following values:
    b6b5b4b6b5b4
    0 00=–100=–
    0 01=–101=–
    0 10=–110=–
    0 11=2 sec.111=8 sec.
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 NDA-24298
    Page 146
    Issue 1
    ASYD : Assignment of System Data 
    Note 1:When this data has been set as specified below, the alarm message output value becomes 80% and the alarm message
    output clear message output value becomes 50% regardless of the data.
    When the data of INDEX 249 is smaller than or equal to the data of INDEX 250
    When these data values are not valid. 12480
    b0 ~ b3Not used
    b4Call Forward Don’t Answer After Attendant Camp-On
    0/1 = No/Yes
    b5Not used
    b6
    When the destination station has been set Call Forwarding - Don’t 
    Answer
    0 = Recall to the station
    1 = C.F. – Don’t Answer is activated.
    Note:Available for software Release 9 or later.
    b7
    Tone to be sent out when the handset is off-hook at the station on 
    which C.F. – All Calls service is set.
    0/1 = Dial Tone (DT)/Special Dial Tone (SPDT)
    249
    b0 ~ b7
    SMDR output buffer usage rate (01–99%) at the time of output of 
    SMDR Buffer Overflow Alarm message (System Message 6-O)
    Note 1
    Example:
    Indicates that the usage rate has been set to 80%.
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM
    DATA
    INDEX
    (INDEX)
    0 - 511DATA
    (DATA)
    00 - FF
    (Hex)BIT
    CORRESPONDING
    DATA
    SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    b7b6b5b4b3b2b1b0
    Unit
    Tens
    b7b6b5b4b3b2b1b0
    80 10 000 000 
    						