    							NDA-24298 CHAPTER 4
    Page 617
    Issue 1
    AAED : Assignment of Announcement Equipment Data
    4. Data Sheet
    Note:Parameter LANG is available for the Hotel System.
    TENANT 
    NUMBER
    (TN)ANNOUNCEMENT
    EQUIPMENT
    NUMBER
    (EQP) 
    0-127KIND OF
    LANGUAGE
    (LANG)
    0-15
    NoteDURATION 
    OF 
    CONNECTION 
    (C)
    0/1SENDING
    RBT
     (R)
    0/1ANSWER
    SIGNAL
    SENDING
    (A) 
    0/1MULTIPLE
    CONNECTION
    (M)
    0/1ROU TE
    NUMBER
    (RT)TRUNK
    NUMBER
    (TK)REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 618
    Issue 1
    AAEDL : Assignment of Announcement Equipment Data for LDM
    AAEDL: Assignment of Announcement Equipment Data for LDM
    1. General
    This command assigns the connected trunk data and the condition related to Announcement Equipment. 
    2. Precautions
    The applicable Tenant Number (TN) range is designated by the ASYD command, SYS1, INDEX8. If data in
    this command is common for all tenants (ASYDL command, SYS1, INDEX800 bit7=1), assign TN parameter
    as data “1” for all tenants. 
    						
    							NDA-24298 CHAPTER 4
    Page 619
    Issue 1
    AAEDL : Assignment of Announcement Equipment Data for LDM
    3. Data Entry Instructions
    Enter EQP as the service feature provided by DAT. 
    0=Dead Level Number
    1=Unused Number
    2=Remote Access to PBX
    3=May be used for other purposes
    4=Outgoing Trunk Busy Announcement
    5-6=May be used for other purposes
    7=Route Restriction Announcement
    8-14=May be used for other purposes
    15=Alert Service(for Hotel system)
    16=Timed Reminder Set Message (for Business system)/
          Service Set-up Message (for Hotel system)
    17=Service Set-up Failure Message (for Hotel system)
    18=Timed Reminder Cancel Message (for Business system)/
          Service Cancel Message (for Hotel Massage)
    19=Service Cancel Failure Message (for Hotel system)
    20=Room Cut-Off Announcement (for Hotel system)
    21=Do Not Disturb Announcement (for Hotel system)
    22=Timed Reminder/Wake Up Call Message for Announcement Trunk
    23-31=Group Announcement (for Hotel system)
    32=Delay Announcement-Attendant (for U.S.A./Canada only)
    33=Not Used
    34=Automated Attendant (1st Announcement)
    35=Automated Attendant (2nd Announcement)
    36=Slumber Time-Do Not Disturb (for Slumber Time Group 1)
    37=Slumber Time-Do Not Disturb (for Slumber Time Group 2)
    38=Slumber Time-Do Not Disturb (for Slumber Time Group 3)
    39=Slumber Time-Do Not Disturb (for Slumber Time Group 4)
    40=Slumber Time-Do Not Disturb (for Slumber Time Group 5)
    41=Slumber Time-Do Not Disturb (for Slumber Time Group 6)
    42=Slumber Time-Do Not Disturb (for Slumber Time Group 7)
    43-48=Not Used
    49-53=Delay Announcement Attendant (1st Announcement)
    54-58=Delay Announcement Attendant (2nd Announcement)
    59-121=Not Used
    122-125=Multiple Announcement
    126-127=Not usedEQP
    0=Single connection
    1=Multiple connection M
    Enter TK data.
    Note:This parameter
    appears if M=1
    is entered.TK
    0=30 seconds, and then disconnects
    1=The connection is held until the calling party released C
    TENANT
    NUMBER
    (TN)ANNOUNCEMENT
    EQUIPMENT
    NUMBER
    (EQP)0-127 DURATION OF
    CONNECTION
    (C)
    0/1SENDING
    RBT
    (R)
    0/1ANSWER
    SIGNAL
    SENDING
    (A)
    0/1MULTIPLE
    CONNECTION
    (M)
    0/1LOGICAL
    ROUTE
    NUMBER
    (LGRT)
    1-899TRUNK
    NUMBER
    (TK)
    Enter logical route number.LGRT0=Send RBT
    1=Do not send RBT R
    0=Answer Signal is not sent
    1=Answer Signal is sent A
    Note: The EQP for Hotel system is
    changeable by the AHSY command,
    though the default EQP (service name)
    are listed here.
      Note   Note
      Note
      Note
      Note
      Note  Note
      Note 
    						
    							CHAPTER 4 NDA-24298
    Page 620
    Issue 1
    AAEDL : Assignment of Announcement Equipment Data for LDM
    4. Data Sheet
    TENANT 
    NUMBER
    (TN)ANNOUNCEMENT
    EQUIPMENT
    NUMBER
    (EQP) 
    0-127DURATION 
    OF 
    CONNECTION 
    (C)
    0/1SENDING
    RBT
     (R)
    0/1ANSWER
    SIGNAL
    SENDING
    (A) 
    0/1MULTIPLE
    CONNECTION
    (M)
    0/1LOGICAL
    ROUTE
    NUMBER
    (LGRT)
    1-899TRUNK
    NUMBER
    (TK)REMARKS 
    						
    							NDA-24298 CHAPTER 4
    Page 621
    Issue 1
    AAEDN : Assignment of Announcement Equipment Data for NDM
    AAEDN: Assignment of Announcement Equipment Data for NDM
    1. General
    This command assigns the connected trunk data and the condition related to Announcement Equipment. The
    data assigned by this command is written in the Network Data Memory (NDM) of the Network Control Node
    (NCN), updating the NDM at each Local Node (LN).
    2. Precautions
    The applicable Tenant Number (TN) range is designated by the ASYDN command, SYS1, INDEX8. If data in
    this command is common for all tenants (ASYDN command, SYS1, INDEX800 bit7=1), assign TN parameter
    as data “1” for all tenants. 
    						
    							CHAPTER 4 NDA-24298
    Page 622
    Issue 1
    AAEDN : Assignment of Announcement Equipment Data for NDM
    3. Data Entry Instructions
    Enter EQP as the service feature provided by DAT. 
    0=Dead Level Number
    1=Unused Number
    2=Remote Access to PBX
    3=May be used for other purposes
    4=Outgoing Trunk Busy Announcement
    5-6=May be used for other purposes
    7=Route Restriction Announcement
    8-14=May by used for other purposes
    15=Alert Service(for Hotel system)
    16=Timed Reminder Set Message (for Business system)/
          Service Set-up Message (for Hotel system)
    17=Service Set-up Failure Message (for Hotel system)
    18=Timed Reminder Cancel Message (for Business system)/
          Service Cancel Message (for Hotel Massage)
    19=Service Cancel Failure Message (for Hotel system)
    20=Room Cut-Off Announcement (for Hotel system)
    21=Do Not Disturb Announcement (for Hotel system)
    22=Timed Reminder/Wake Up Call Message for Announcement Trunk
    23-31=Group Announcement (for Hotel system)
    32=Delay Announcement-Attendant (for U.S.A./Canada only)
    33=Not Used
    34=Automated Attendant (1st Announcement)
    35=Automated Attendant (2nd Announcement)
    36=Slumber Time-Do Not Disturb (for Slumber Time Group 1)
    37=Slumber Time-Do Not Disturb (for Slumber Time Group 2)
    38=Slumber Time-Do Not Disturb (for Slumber Time Group 3)
    39=Slumber Time-Do Not Disturb (for Slumber Time Group 4)
    40=Slumber Time-Do Not Disturb (for Slumber Time Group 5)
    41=Slumber Time-Do Not Disturb (for Slumber Time Group 6)
    42=Slumber Time-Do Not Disturb (for Slumber Time Group 7)
    43-48=Not Used
    49-53=Delay Announcement Attendant (1st Announcement)
    54-58=Delay Announcement Attendant (2nd Announcement)
    59-121=Not Used
    122-125=Multiple Announcement
    126-127=Not usedEQP
    0=Single connection
    1=Multiple connection M
    Enter TK data.
    Note:This parameter 
    appears if M=1 
    is entered.TK
    0=30 seconds, and then disconnects
    1=The connection is held until the calling party released C
    TENANT
    NUMBER
    (TN)ANNOUNCEMENT
    EQUIPMENT
    NUMBER
    (EQP)0-127 DURATION OF
    CONNECTION
    (C)
    0/1SENDING
    RBT
    (R)
    0/1ANSWER
    SIGNAL
    SENDING
    (A)
    0/1MULTIPLE
    CONNECTION
    (M)
    0/1LOGICAL
    ROUTE
    NUMBER
    (LGRT)
    1-899TRUNK
    NUMBER
    (TK)
    Enter logical route number.LGRT0=Send RBT
    1=Do not send RBT R
    0=Answer Signal is not sent
    1=Answer Signal is sent A
    Note: The EQP for Hotel system is
    changeable by the AHSY command,
    though the default EQP (service name)
    are listed here.
      Note   Note
      Note
      Note
      Note
      Note  Note
      Note 
    						
    							NDA-24298 CHAPTER 4
    Page 623
    Issue 1
    AAEDN : Assignment of Announcement Equipment Data for NDM
    4. Data Sheet
    TENANT 
    NUMBER
    (TN)ANNOUNCEMENT
    EQUIPMENT
    NUMBER
    (EQP) 
    0-127DURATION 
    OF 
    CONNECTION 
    (C)
    0/1SENDING
    RBT
     (R)
    0/1ANSWER
    SIGNAL
    SENDING
    (A) 
    0/1MULTIPLE
    CONNECTION
    (M)
    0/1LOGICAL
    ROUTE
    NUMBER
    (LGRT)
    1-899TRUNK
    NUMBER
    (TK)REMARKS 
    						
    							CHAPTER 4 NDA-24298
    Page 624
    Issue 1
    AHMS : Assignment of Music on Hold Data
    AHMS: Assignment of Music on Hold Data
    1. General
    This command is used when a trunk provides Extended Hold Music. With this feature, the system supplies the
    DAT card (only the first port of DAT) involved in Hold Music to a trunk route specified on this command. Since
    the Extended Hold Music affects a trunk only, a station user may hear the ordinary Hold Music.
    2. Precautions
    1. A DAT card is required for the Extended Hold Music feature, and DAT should be mounted in the slot
    specified by the HMSC parameter of this command.
    Other trunk circuit cards cannot be mounted in the LENS described in the HMSC parameter. However, any
    line circuit card can be mounted there.
    2. The system data should be assigned as ASYD, SYS 1, INDEX 42, bit 3 = 1 (Extended Hold Music). 
    When assigned this system data, the trunk busy lamp of the DAT card is turned on.
    3. The DAT card accommodation should be assigned by the ATRK command. 
    4. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.  
    						
    							NDA-24298 CHAPTER 4
    Page 625
    Issue 1
    AHMS : Assignment of Music on Hold Data
    3. Data Entry Instructions
    1 = Extended Hold Music
    2 = Sound Source LENS (Not used in USA) TYPE
    1 = Tenant Numbering of Hold Station (Not used in USA)
    2 = Route Number of Held Trunk
    3 = Tenant number of hold station and route numbering of
          held trunk. (Not used in USA)  KIND
    OPERATION
    TYPE
    (TYPE)
    1/2OPERATION
    KIND
    (KIND)
    1-3MUSIC ON
    HOLD DATA
    (HMSC)
    0-15EXTENSION HOLD
    STATION DATA
    (STA)
    0/1LINE
    EQUIPMENT
    NUMBER
    (LENS) TENANT
    NUMBER
    (TN)ROUTE
    NUMBER
    (RT)
    The parameters TYPE and KIND determine whether
    the other parameters are displayed or not. 1 1 0  2 
    TYPE/KIND
    Trunk route number which provides
    the Extended Hold Music. RT
    Music on Hold Data 
    0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15000050
    000070
    000090
    000110
    000130
    000150
    000170
    000190
    001050
    001070
    001090
    001110
    001130
    001150
    001170
    001190 HMSC
    HMSC LENS of DAT
    STA
    0 = Specified Music on Hold is not 
          sent to station
    1 = Specified Music on Hold is sent 
          to station  
    						
    							CHAPTER 4 NDA-24298
    Page 626
    Issue 1
    AHMS : Assignment of Music on Hold Data
    4. Data Sheet
    OPERATION 
    TYPE
    (TYPE)
    1/2OPERATION 
    KIND 
    (KIND)
    1-3TENANT 
    NUMBER 
    (TN)ROUTE 
    NUMBER 
    (RT)MUSIC ON HOLD 
    DATA  
    (HMSC)
    0-15EXTENSION HOLD 
    STATION DATA 
    (STA)
    0/1LINE 
    EQUIPMENT 
    NUMBER 
    (LENS) 
    						