Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1718
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    927 System Parameters Call Coverage / Call Forwarding 
    17
    However, you can enter y in this field to have QSIG VALU call coverage take 
    precedence. In this case, if the Coverage After Forwarding option on the Station 
    screen is enabled for a user, then QSIG Diversion with Rerouting is not be 
    attempted.
    Station Hunt Before Coverage
    This field allows you to choose whether a call to a busy station performs station 
    hunting before going to coverage.
    Call Forward Override
    This field specifies how to treat a call from a forwarded-to party to the 
    forwarded-from party.
    Coverage After Forwarding
    This field governs whether an unanswered forwarded call is provided coverage 
    treatment. 
    Valid entries Usage
    y/n
    Enter y to allow Coverage After Forwarding to work when it is 
    activated on a user’s Station screen and Diversion with 
    Rerouting is also turned on.
    Valid entries Usage
    y/n
    Enter y to use Station Hunt Before Coverage.
    Valid entries Usage
    y
    Overrides the Call Forwarding feature by allowing a 
    forwarded-to station to complete a call to the forwarded-from 
    station.
    nDirects the system to forward calls to a station even when they 
    are from the forwarded-to party.
    Valid entries Usage
    y
    Coverage treatment is provided to unanswered forwarded 
    calls.
    nNo coverage treatment is provided to unanswered forwarded 
    calls. The call remains at the forwarded-to destination. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    928 System Parameters Call Coverage / Call Forwarding 
    17
    Field descriptions for page 2
    Screen 188. System-Parameters Coverage-Forwarding 
    Coverage Of Calls Redirected Off-Net Enabled
    This field allows you to enable/disable the Coverage of Calls Redirected Off-Net 
    (CCRON) feature. This field provides a quick means of disabling this feature if 
    the demand on the call classifier port resources degrades other services provided 
    by the switch. The Coverage of Calls Redirected Off-Net field on this screen must 
    be 
    y to administer this field.
    Activate Answer Detection (Preserves SBA) On 
    Final CCRON Cvg Point
    This field appears only if the Coverage of Calls Redirected Off-Net Enabled field 
    on this screen is 
    y.
    When the system redirects a call off-net at the final coverage point in a coverage 
    path, the system can apply no further coverage treatment even if the call is 
    unanswered. The only reason for activating answer detection on such a call is to 
    maintain the simulated bridged appearance (SBA) on the principal’s phone that 
    allows the principal to answer or bridge onto the call. However, when the system 
    monitors the call through use of a call classifier port, there is an inherent 
    cut-through delay following the detection of answer at the far end. This field has 
    no consequence when the off-net call is carried end-to-end by ISDN facilities; the 
    SBA is maintained and there is no cut-through delay.
    Valid entries Usage
    y
    DEFINITY ECS monitors off-net coverage/forwarded calls 
    and provides further coverage treatment for unanswered calls.
    nDEFINITY ECS does not monitor offnet coverage/forwarded 
    calls. No further coverage treatment is provided if such calls 
    are unanswered.
    change system-parameters coverage-forwarding                     Page 2 of 2
               SYSTEM PARAMETERS -- CALL COVERAGE / CALL FORWARDING
    COVERAGE OF CALLS REDIRECTED OFF-NET (CCRON)
    Coverage Of Calls Redirected Off-Net Enabled? y
      Activate Answer Detection (Preserves SBA) On Final CCRON Cvg Point? y
    Ignore Network Answer Supervision? y
    Disable call classifier for CCRON over ISDN trunks? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    929 System Parameters Call Coverage / Call Forwarding 
    17
    Ignore Network Answer Supervision
    This field appears only if the Coverage of Calls Redirected Off-Net Enabled field 
    on this screen is 
    y.
    CCRON may use a call classifier port to determine whether an off-net coverage or 
    forwarded call has been answered, discarding other information that may indicate 
    an answered state. However, some customers pay the operating company to 
    provide network answer supervision on their trunks and desire that CCRON not 
    discard that information. They may preserve this service by setting this field to 
    n.
    On the other hand, beware when you tandem a call over a tie trunk through 
    another switch node from where it redirects to the public network over non-ISDN 
    facilities. If the trunk on the far-end node sends a timed answer supervision, that 
    may get tandemed back to the originating switch as a network answer. In such a 
    scenario, the originating switch interprets the call as answered, leading to some 
    undesirable behavior. To avoid these calls from mistakenly be treated as 
    answered, set this field to 
    y. An unfortunate consequence is that a short 
    cut-through delay that is inherent to call classification is introduced when the call 
    is answered. 
    Disable call classifier for CCRON over ISDN 
    trunks
    When a CCRON call routes offnet over ISDN end-to-end facilities, no call 
    classifier is attached to the call. If, subsequently during the call, an ISDN 
    PROGRESS or ALERT message is received that indicates that interworking has 
    occurred, a call classifier is normally attached to the call and assumes precedences 
    Valid entries Usage
    y
    Directs the system to maintain a simulated bridged appearance 
    on the principal when redirecting to a final off-net coverage 
    point.
    nAllows the system to drop the SBA on the principal’s phone 
    when the call redirects off-net at the last coverage point, 
    eliminating the cut-through delay inherent in CCRON calls, 
    but sacrificing the principal’s ability to answer the call.
    Valid entries Usage
    y
    Ignore network answer supervision and rely on the call 
    classifier to determine when a call is answered.
    nTreat network answer supervision as a true answer. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    930 System Parameters Country-Options 
    17
    over ISDN trunk signalling. This field provides a customer the means of directing 
    the switch to dispense with the call classifier on interworked calls and rely on the 
    ISDN trunk signalling messages.
    System Parameters Country-Options
    This screen implements parameters associated with certain international 
    (including North American) call characteristics. You cannot change this screen. 
    See your Lucent representative if you want to modify any of the values here. 
    Refer to the following table for country codes throughout this screen. 
    Country code table
    Valid entries Usage
    y
    Use y to disable the call classifier for CCRON calls over 
    interworked trunk facilities.
    nUse n to enable the call classifier for CCRON calls over 
    interworked trunk facilities.
    Code Country
    1
    United States, Canada
    2Australia
    3Japan
    4Italy
    5Netherlands
    6Singapore
    7Mexico
    8Belgium, Luxembourg
    9Saudi Arabia
    10United Kingdom
    11Spain
    12France 
    13Germany
    14Czech Republic, Slovakia
    15Russia (CIS) 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    931 System Parameters Country-Options 
    17
    Field descriptions for page 1
    Screen 189. System Parameters Country-Options 
    Companding Mode
    Identifies the companding algorithm to be used by system hardware.
    16Argentina
    17Greece
    18China
    19Hong Kong
    20Thailand
    21Macedonia
    22Poland
    23Brazil
    24Nordic
    25South Africa
    Valid entries Usage
    A-law
    Generally used outside the US
    Mu-law  Generally used in the US
    Code Country
    change system-parameters country-options   Page 1 of 7
                                                                              
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
         Companding Mode: Mu-Law         Base Tone Generation Set: 1
    440Hz PBX-dial Tone? n   440Hz Secondary-dial Tone? n
    Analog Ringing Cadence: 1  Set Layer 1 timer T1 to 30 seconds? n
    Analog Line Transmission: 1
    64/84xx Display Character Set? Roman
    Howler After Busy: y     Disconnect on No Answer by Call Type: y
    TONE DETECTION PARAMETERS
            Tone Detection Mode: 5             Dial Tone Validation Timer:
                 Interdigit Pause: short 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    932 System Parameters Country-Options 
    17
    Base Tone Generation Set
    The country code identifies the base tone generation set to be used. This field is 
    meaningful only if the system tone detector is a TN780, vintage 4 or a TN2182.
    A TN780 vintage 5 or greater or a TN2182 is required if Belgian Tones (Country 
    code 8) are specified.
    440Hz PBX-dial Tone
    Specifies whether the switch (primary) dial tone will be changed to a continuous 
    440Hz/-17 tone.
    440Hz Secondary-dial Tone
    Specifies whether the Secondary (CO) dial tone will be changed to a continuous 
    440Hz/-17 tone.
    Analog Ringing Cadence
    The country code identifies the ringing cadence to be used by analog phones in the 
    system.
    Valid entries Usage
    1
    –25 Refer to the Country code table at the beginning of this screen 
    description. 
    Valid entries Usage
    y/n
     A value of n implies the tone will either be administered on a 
    later page of this screen or, if no individual definition is 
    administered, as defined in Base Tone Generation Set.
    Valid entries Usage
    y/n
     A value of n implies the tone will either be administered on a 
    later page of this screen or, if no individual definition is 
    administered, as defined in Base Tone Generation Set.
    Valid entries Usage
    1 
    to 25Refer to the Country code table at the beginning of this screen 
    description. For more information on, see Audible Ringing 
    Patterns in DEFINITY ECS System Description. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    933 System Parameters Country-Options 
    17
    Set Layer 1 timer T1 to 30 seconds
    Analog Line Transmission
    The country code identifies the transmission and signaling parameters.
    Enhanced 64xx/84xx Display Character Set 
    Howler After Busy
    Plays howler tone when users leave their analog phone off-hook too long.
    Disconnect on No Answer by Call Type
    Drops outgoing trunk calls (except DCS and AAR) that users leave unanswered 
    too long.
    Valid entries Usage
    y/n
      Specifies whether the Layer 1 timer is set to 30 seconds.
    Valid entries Usage
    1
    –25Refer to the Country code table at the beginning of this screen 
    description.
    Valid entries Usage
    cyrillic
    katakana
    roman
    ukranian
    Indicate the enhanced character set to display. SeeEnhanced 
    Telephone Display for more information. 
    Valid entries Usage
    y/n
      Enables howler tone.
    Valid entries Usage
    y/n
      Enables the system to disconnect calls that are not answered. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    934 System Parameters Country-Options 
    17
    Tone Detection Mode 
    The country code specifies the type of tone detection used on a TN420B (or later) 
    tone-detection circuit pack.
    Dial Tone Validation Timer
    Displays number of milliseconds that the dial tone validation routine will use to 
    sample transmissions. This field appears only when Tone Detection Mode is equal 
    to 
    4 or 5. (Valid with TN420C or later Tone Detector circuit pack.)
    Interdigit Pause
    Specifies the maximum length of the inter-digit pause. Breaks lasting less than 
    this range will be bridged or ignored. (Valid with TN420C or later Tone Detector 
    circuit pack.)
    Valid entries Usage
    1
    Precise Italian tone detection algorithm
    2Precise Australian tone detection algorithm
    3Precise UK tone detection algorithm
    4Imprecise normal broadband filter algorithm (valid with 
    TN420C or later Tone Detector circuit pack)
    5Imprecise wideband filter algorithm (valid with TN420C or 
    later Tone Detector circuit pack)
    6 
    Valid entries Usage
    0
    –6375 in increments of 25
    600 
    Valid entries Usage
    short
       5 to 30ms
    long20 to 40ms 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    935 System Parameters Country-Options 
    17
    Field descriptions for page 2
    Screen 190. System Parameters Country-Options 
    Digital Loss Plan
    Provides the default values for digital loss plan and n-party conference loss.
    Customize
    Appears when the Digital Loss Plan Modification field is enabled on the 
    System-Parameters Customer-Options screen.
    FROM / TO
    Identifies the variable digital loss values.
    Valid entries Usage
    1 
    - 25Refer to the Country code table at the beginning of this 
    screen description. 
    Valid entries Usage
    y/n
    Enables customization on the 2-party loss table.
    Valid entries Usage
    -3 
    - 15An unsigned number is a loss, while a number preceded with 
    a minus sign is a gain.
      Page   1 of   5
    OPTIONAL FEATURES
                      G3 Version: V6  Maximum Ports:  300
    Abbreviated Dialing Enhanced List? n CAS Main? n
     Access Security Gateway? n Cvg Of Calls Redirected Off-net? n
    Analog Trunk Incoming Call ID? n  DCS (Basic)? n
     A/D Grp/Sys List Dialing Start at 01? n  DCS Call Coverage? n
    Answer Supervision by Call Classifier? n DCS with Rerouting? n
                                      ARS? y DEFINITY Network Admin? n
    ARS/AAR Partitioning? y  DS1 MSP? n
        ASAI Interface? n
    ASAI Proprietary Adjunct Links? n Emergency Access to Attendant? y
    Async. Transfer Mode (ATM) PNC? n  Extended Cvg/Fwd Admin? n
    Async. Transfer Mode (ATM) Trunking? n External Device Alarm Admin? n
    ATMS? n Flexible Billing? n
    Audible Message Waiting? n Forced Entry of Account Codes? n
    Authorization Codes? n Global Call Classification? n
      CAS Branch? n Hospitality (Basic)? ydisplay system-parameters country-otpions   Page 2 of 7
    2 PARTY LOSS PLAN
    Digital Loss Plan: 1  Customize? n
    TO
    12345 6 7 8 9 10 11 12 13 14 15 16 17
    1:-10003000030666033
    2:00000332230666233
    3:00000333230666033
    4:150006000030666033
    5:0-3-300 -3-3-3-30-3300-333
    6:03300686555999533
    F 7:03300886555999533
    R 8:03300666353966333
    O 9:02200553002333933
    M 10:33333555003333333
    11:00000553230663033
    12:00000333-3-30000033
    13:00000333-3-30000033
    14:00000333-3-3-3000033
    15:02000553030666033
    16:33333333333333333
    17:33333333333333333 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    936 System Parameters Country-Options 
    17
    Field descriptions for page 3
    Screen 191. System Parameters Country-Options 
    Digital Tone Plan
    Provides the default values for tone loss for the selected country.
    Customize
    Appears when, on the System-Parameters Customer-Options screen, the Digital 
    Loss Plan Modification field is 
    y. Valid entries Usage
    1 
    - 25Refer to the Country code table at the beginning of this 
    screen description. 
    Valid entries Usage
    y/n
    Enables customization on the 2-party loss table.
      Page   1 of   5
    OPTIONAL FEATURES
                      G3 Version: V6  Maximum Ports:  300
    Abbreviated Dialing Enhanced List? n CAS Main? n
     Access Security Gateway? n Cvg Of Calls Redirected Off-net? n
    Analog Trunk Incoming Call ID? n  DCS (Basic)? n
     A/D Grp/Sys List Dialing Start at 01? n  DCS Call Coverage? n
    Answer Supervision by Call Classifier? n DCS with Rerouting? n
                                      ARS? y DEFINITY Network Admin? n
    ARS/AAR Partitioning? y  DS1 MSP? n
        ASAI Interface? n
    ASAI Proprietary Adjunct Links? n Emergency Access to Attendant? y
    Async. Transfer Mode (ATM) PNC? n  Extended Cvg/Fwd Admin? n
    Async. Transfer Mode (ATM) Trunking? n External Device Alarm Admin? n
    ATMS? n Flexible Billing? n
    Audible Message Waiting? n Forced Entry of Account Codes? n
    Authorization Codes? n Global Call Classification? n
      CAS Branch? n Hospitality (Basic)? ydisplay system-parameters country-otpions   Page 3 of 7
    TONE & CONFERENCE LOSS PLANS
    Digital Tone Plan: 1  Customize? n
    TO
    12345 6 7 8 9 10 11 12 13 14 15 16 17
    Dial:03300666506555500
    Confirm:00000000000000000
    Reorder:00000000000000000
    Busy:00000000000000000
    Ringing:00000000000000000
    Spec Ring:00000000000000000
    Intercept:00000000000000000
    Waiting:00000000000000000
    Verify:00000000000000000
    Intrude:00000000000000000
    Zip:333-3-3-3-3-3-3-3-3-3-3-3-300
    Music:03300666306333300
    End-to-End total loss (dB) in a n-party conference:
    3:____ 4:____ 5:____ 6:____ 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual