Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 757 ISDN trunk group 17 Design Considerations ISDN-BRI and ISDN-PRI interfaces cannot be mixed in the same trunk group. Therefore, consider the following: nThe earliest trunk member (the lowest numbered one) administered is considered correct. nIf an offending member is subsequently found (meaning the first member was BRI and a later member was PRI, or vice versa), the cursor positions on the offending member, and the following error message appears: Cannot mix BRI and PRI ports in the same trunk group. Field descriptions for page 1 Many of the fields on the following screens are described in ‘‘ Trunk Group’’ on page 980. If a field on this screen is unique, it is listed and defined. Screen 113. ISDN Trunk Group screen The Calling Number – Delete, Insert, and Numbering Format fields are the administrable fields for the Calling Line Identification Prefix feature. They appear when the Direction field is incoming or two-way. add trunk-group next Page 1 of x TRUNK GROUP Group Number: xxx Group Type: isdn CDR Reports: y Group Name: OUTSIDE_CALL_______________ COR: 1_ TN: 1__ TAC: ____ Direction: two-way_ Outgoing Display? n Carrier Medium: PRI/BRI Dial Access? n Busy Threshold: 99_ Night Service: ____ Queue Length: 0__ Service Type: ________________ Auth Code? n TestCall ITC: rest Usage Alloc:_________________________Far End Test Line No: _______________ TestCall BCC: 4 TestCall Service: ______________ TRUNK PARAMETERS Codeset to Send Display: 6 Codeset to Send TCM,Lookahead: 6 Max Message Size to Send: 260 Charge Advice: none_____________ Supplementary Service Protocol: a Digit Handling(in/out):overlap/overlap Digit Treatment: insertion Digits: 1234 Trunk Hunt: cyclical QSIG Value-Added Lucent? n Digital Loss Group: __ Calling Number - Delete: ___ Insert: _______________ Numbering Format: _______ Bit Rate: 1200_ Synchronization: async Duplex: full Disconnect Supervision - In? y Out? n Answer Supervision Timeout: 0__
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 758 ISDN trunk group 17 Calling Number – Delete Calling Number – Insert Calling Number – Numbering Format This field indicates the TON/NPI encoding applied to CPN information modified by the CLI Prefix feature. This encoding does not apply to calls originating locally. The Numbering Format field on page 2 of this screen applies to calls originated from this switch. If this field is blank, DEFINITY ECS passes on the encoding received in the incoming setup message. If the incoming setup message did not contain CPN information and digits are added, the outgoing message will contain these digits. If the Numbering Format field is blank in this case, the value defaults to pub-unk. If the Numbering Format field on page 2 of this screen is also administered as unknown, the trunk group is modified to “unk-unk” encoding of the TON/NPI. Therefore, this field also must contain a value other than unknown. NOTE: The values for this field map to the Type of Numbering (TON) and Numbering Plan Identifier (NPI) values shown below. Valid entries Usage 1 to 15Enter the number of digits, if any, to delete from the calling party number for all incoming calls on this trunk group. all blank Valid entries Usage 1 to 15Enter the specific digits, if any, to add to the beginning of the digit string of incoming calls when the calling party is a member of this trunk group. blank Valid entriesType of numbering (TON) Numbering plan identifier (NPI) blank incoming TON unmodifiedincoming NPI unmodified natl-pubnational(2) E.164(1) intl-pubinternational(1) E.164(1) locl-publocal/subscriber(4) E.164(1) pub-unkunknown(0) E.164(1)
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 759 ISDN trunk group 17 Carrier Medium This field lets you to specify the type of transport medium interface used for the ISDN trunk group. Appears only when the Group Type field is isdn and, on the System-Parameters Customer-Options screen, either the Async. Transfer Mode (ATM) Trunking or H.323 field is y. Charge Advice Use this field to accumulate and access charge information about a call. You already must have set the CDR Reports field to y or r (ring-intvl) before changing this field from its default of none. Remember that receiving Advice of Charge during the call (administered as “automatic” or “during-on-request”) affects system performance because of the increased ISDN message activity on the signaling channel, which may reduce the maximum call capacity. lev0-pvtlocal(4) Private Numbering Plan - PNP(9) lev1-pvtRegional Level 1(2) Private Numbering Plan - PNP(9) lev2-pvtRegional Level 2(1) Private Numbering Plan - PNP(9) unk-unkunknown(0) unknown(0) Valid entries Usage AT M The trunk is implemented via the ATM Interface circuit pack. IPThe trunk is implemented via the LAN/WAN (C-LAN)/MedPro Interface circuit pack as an H.323 trunk group. PRI/BRIThe trunk is implemented as a standard DS1 or BRI interface. Valid entriesType of numbering (TON) Numbering plan identifier (NPI)
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 760 ISDN trunk group 17 Codeset to Send Display This field defines the codeset for sending the information element for Display. The value depends on the type of switch to which the user is connected. Codeset to Send National IEs This field defines the codeset for sending the information element (IE) for national IEs. National IEs include all IEs previously sent only in code set 6 (such as DCS IE). Now these national IEs, including Traveling Class Marks (TCMs) and Lookahead Interflow (LAI), can be sent in code set 6 or 7. The value depends on the type of switch the user is connected to. NOTE: A Traveling Class Mark (that is, the user’s FRL or the user’s trunk group FRL) is passed between tandem nodes in an ETN in the setup message only when the Service Type field is tandem. It then is used by the distant tandem switch to permit access to facilities consistent with the originating user’s privileges. Valid entries Usage none Enter none if you do not want the system to collect Advice of Charge information for this trunk group. automaticEnter automatic only if your public network sends Advice of Charge information automatically. end-on- request Enter end-on-request if DEFINITY ECS must request charge information with each call, and you want to receive only the final call charge. during-on- request Enter during-on-request if DEFINITY ECS must request charge information with each call, and you want charges to display during and at the end of a call. Valid entries Usage 0 CCITT 6Any other than CCITT or System 85 R2V4, 4E11 7System 85 R2V4, 4E11 Valid entries Usage 6 Other types. 7System 85 R2V4, 4E11, or newer switch types
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 761 ISDN trunk group 17 Digit Handling (in/out) This field defines whether overlap receiving and overlap sending features are enabled. Set the field to overlap when you want overlap receiving or overlap sending. Set to enbloc when you do not want these features enabled. The first field value indicates digit receiving and the second value indicates digit sending. There are 4 possible combinations: enbloc/enbloc, enbloc/overlap, overlap/enbloc, and overlap/overlap. Without overlap receiving or sending enabled, the digits on incoming and outgoing calls are sent enbloc. If the Digit Handling field is overlap/enbloc or overlap/overlap, the following results: — Incoming Call Handling Treatment table does not appear — The Digit Treatment and Digits fields appear — Warning message indicates that all Incoming Call Handling entries are removed when screen is submitted — When screen is submitted with these values, all Incoming Call Handling entries are removed Far End Test Line No. Specifies the number sent to the far-end’s ISDN test line extension. When the test trunk long command is issued, this exact number is sent to the far-end to establish a call that tests the integrity of the trunk member under test. The number does not pass through routing or undergo digit manipulation. The digits entered must be what the far-end expects. For example, for an ISDN tandem trunk, the far-end test number should be a 7-digit ETN (Electronic Tandem Network) number. Up to 15 digits may be entered in this field.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 762 ISDN trunk group 17 Max Message Size to Send Defines the maximum size of ISDN messages sent by the switch. Currently, the system can receive 260 byte messages. Valid entries are 128, 244, 256, and 260. The following table indicates the expected ISDN-PRI message size from several Lucent Technologies products. QSIG Value-Added Lucent Provides QSIG-VALU services. This field appears only if the Value-Added Lucent (VALU) field on the System-Parameters Customer-Options screen is y. This field can be set to y only if the Supplementary Service Protocol field on the System-Parameters Customer-Options screen is b. Valid entries are y and n. Blank is not a valid entry. Service Type Indicates the service for which this trunk group is dedicated. The following table provides a listing of predefined entries. In addition to the Services/Features listed in this table, any user-defined Facility Type of 0 (feature) or 1 (service) on the Network Facilities screen is allowed. Up to 10 (G3si, G3csi) or 200 (G3r) ISDN trunk groups can have this field administered as cbc. ProductsMessage Length (octets) Received 4ESS (4E11) 256 4ESS (4E13) 256 4ESS (4E14) 256 5ESS (5E4) 244 5ESS (5E5) 244 5ESS (5E6) 244 System 75 (all) 260 System 85 (R2V4) 128 System 85 (R2V5) 260 System 85 (R2V6) 260
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 763 ISDN trunk group 17 Valid entries Usage access A tie trunk giving access to an Electronic Tandem Network. accunetACCUNET Switched Digital Service — part of ACI (AT&T Communications ISDN) phase 2. cbcCall-by-Call service — provides different dial plans for different services on an ISDN trunk group. Indicates this trunk group is used by the Call-By-Call Service Selection feature. dmi-mosDigital multiplexed interface — message oriented signaling. i800International 800 Service — allows a subscriber to receive international calls without a charge to the call originating party. inwatsINWATS — provides OUTWATS-like pricing and service for incoming calls. ldsLong-Distance Service — part of ACI (AT&T Communications ISDN) phase 2. megacomMEGACOM Service — an AT&T communications service that provides unbanded long-distance services using special access (switch to 4ESS switch) from an AT&T communications node. mega800MEGACOM 800 Service — an AT&T communications service that provides unbanded 800 service using special access (4ESS switch to switch) from an AT&T communications node. multiquestAT&T MULTIQUEST Telecommunications Service — dial 700 service. A terminating-user’s service that supports interactive voice service between callers at switched-access locations and service provides directly connected to the AT&T Switched Network (ASN). operatorNetwork Operator — provides access to the network operator. outwats-bndOUTWATS Band — WATS is a voice-grade service providing both voice and low speed data transmission capabilities from the user location to defined service areas referred to as bands; the widest band is 5. public-ntwrkPublic network calls — It is the equivalent of CO (outgoing), DID, or DIOD trunk groups. If Service Type is public-ntwrk, Dial Access can be set to y. sddnSoftware Defined Data Network — provides a virtual private line connectivity via the AT&T switched network (4ESS switch). Services include voice, data, and video applications. These services complement the SDN service. Do not use for DCS with Rerouting. Continued on next page
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 764 ISDN trunk group 17 Supplementary Service Protocol Indicates which supplementary service protocol to use for services over this trunk group. Supplementary Service protocols are mutually exclusive. sdnSoftware Defined Network (SDN) — an AT&T communications offering that provides a virtual private network using the public switched network. SDN can carry voice and data between customer locations as well as off-net locations. sub-operatorPresubscribed Common Carrier Operator — provides access to the presubscribed common carrier operator. tandemTandem tie trunks integral to an ETN tieTie trunks — general purpose wats-max-bndMaximum Banded Wats — a WATS-like offering for which a user’s calls are billed at the highest WATS band subscribed to by users. Valid entries Usage a National public network/Shared UUI (for ISDN-BRI) National public network (for ISDN-PRI) bISO/ETSI QSIG Private Network cETSI public network dEuropean Computer Manufacturer’s Association (ECMA) QSIG private network (supports only Name Identification and Additional Network Feature Transit Counter (ANF-TC)) eDCS with Rerouting — Do not use the Service Type field entry of dmi-mos or sddn with this option. — Set the Used for DCS field (on page 2) to y. fISDN Feature Plus Public network feature plus signaling. Valid entries Usage Continued on next page
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 765 ISDN trunk group 17 Test Call BCC Indicates the Bearer Capability Code (BCC) used for the ISDN test call. Testcall ITC Controls the encoding of the Information Transfer Capability (ITC) codepoint of the bearer capability IE in the SETUP message when generating an ISDN test call. Allowed values are rest (restricted) and unre (unrestricted). NOTE: ISDN Testcall feature has no routing, so a testcall is never blocked due to an incompatible ITC. Testcall Service Specifies the call-by-call selection for an ISDN test call. Only appears if the Service Type field is cbc. Valid entries are all of the services listed in ‘‘ Service Type’’ on page 762, excluding sddn or any new Facility Type of 0 (feature), 1 (service), or 3 (outgoing) that is defined by users on the Network Specific Facility Encoding screen. Trunk Hunt The switch performs a trunk hunt when searching for available channels within a facility in an ISDN trunk group. Enter ascend to enable a linear trunk hunt search from the lowest to highest numbered channels, or descend for a linear trunk hunt search from the highest to lowest numbered channels. With both ascend and descend, all trunks within an ISDN trunk group are selected based on this field and without regard to the order in which trunks are administered within the trunk group. Enter cyclical to enable a circular trunk hunt based on the sequence the trunks were administered within the trunk group. When using ISDN-BRI interfaces, only cyclical is allowed. NOTE: The cyclical option cannot be set if the trunk group using ISDN-PRI interfaces is to be used for Wideband operations (the Wideband Support field set to y). Valid entries Usage 0 Voice 1Mode 1 2Mode 2 Asynchronous 3Mode 3 Circuit 4Mode 0
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 766 ISDN trunk group 17 The search can be administered per ISDN-PRI trunk group, but it infers the direction of search within all ISDN-PRI facilities (or portions of those facilities) administered within the trunk group. Usage Alloc Appears when the Service Type field is cbc. Specifies whether users want to allocate the services provided by the trunk group. Valid entries are y and n. If y is entered, two additional CBC-related screens display. They are the CBC Trunk Group Usage Allocation Plans screen and the CBC Trunk Group Usage Allocation Plan Assignment Schedule. Field descriptions for page 2 Screen 114. ISDN Trunk Group screen add trunk-group next Page 2 of x TRUNK FEATURES ACA Assignment? n Measured: none____ Wideband Support? n Long Holding Time (hours): _ Internal Alert? _ Maintenance Tests? y Short Holding Time (sec): _ Data Restriction? n NCA-TSC Trunk Member: 7 Short Holding Threshold: __ Send Name: n Send Calling Number: n Used for DCS? n Hop Dgt: n Suppress # Outpulsing? n Numbering Format: ______ DCS Signaling: ____ Outgoing Channel ID Encoding: _________ UUI IE Treatment: shared Maximum Size of UUI IE Contents: 128 Replace Restricted Numbers? n Replace Unavailable Numbers? n Send Connected Number: y Send UCID? n Send Codeset 6/7 LAI IE? y Path Replacement Method: better-route US NI Delayed Calling Name Update? n