Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1067 18 Modem Pool Group Multifrequency-Signaling-Related System Parameters Music Sources Action Object Qualifier add modem-pool num [1-MAX] change modem-pool num [1-MAX] display modem-pool num[1-MAX] [’print’ or ’schedule’] list modem-pool num [’print’ or ’remove’] remove modem-pool num [1-MAX] Action Object Qualifier change system-parameters multifrequency-signaling display system-parameters multifrequency-signaling [’print’ or ’schedule’] Action Object Qualifier change music-sources — display music-sources [print or schedule]
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1068 18 Packet Gateway Board Partition Route Table Pickup Group Action Object Qualifier add pgate Enter the circuit pack cabinet, carrier, and slot change pgate Enter the circuit pack cabinet, carrier, and slot display pgate Enter the circuit pack cabinet, carrier, and slot remove pgate Enter the circuit pack cabinet, carrier, and slot Action Object Qualifier change partition-route-table[‘index’ (1-2000)] display partition-route-table [‘index’ (1-2000)] [’print’ or ’schedule’] Action Object Qualifier add pickup-group 1-MAX (or ‘next’) change pickup-group 1-MAX display pickup-group 1-MAX [’print’ or ’schedule’] list intercom-group [1-MAX][’number’ x][’to-number’ x][’count’ n] [’print’ or ’schedule’] remove pickup-group 1-MAX
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1069 18 PRI Endpoint Remote Access Remote Call Coverage Table RHNPA Table Action Object Qualifier add pri-endpointextension or ’next’ change pri-endpoint extension display pri-endpoint extension [’print’ or ’schedule’] list pri-endpoint extension [’count’ X][’print’ or ’schedule’] remove pri-endpoint extension Action Object Qualifier change remote-access — display remote-access [’print’ or ’schedule’] list remote-access — status remote-access [’print’] Action Object Qualifier change coverage remote display coverage remote Action Object Qualifier change rhnpa Enter RHNPA and office code n:xyy n(1-MAX) x(0-MAX) y(0-MAX) y(0-MAX) display rhnpa Enter RHNPA and office code n:xyy n(1-MAX) x(0-MAX) y(0-MAX) y(0-9) [’print’ or ’schedule’]
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1070 18 Route Pattern Second Digit Table Security-Related System Parameters Site Data Action Object Qualifier change route-pattern 1-MAX display route-pattern 1-MAX [print] list route-patternEnter [‘trunk’ (1-MAX)] [‘service’/feature name string] [‘print‘ or ‘schedule’] Action Object Qualifier add second-digit 0-9 change second-digit 0-9 display second-digit [print or schedule] Action Object Qualifier change system-parameters security — display system-parameters security [‘print’ or ‘schedule’] Action Object Qualifier change site-data — display site-data [‘print’ or ‘schedule’]
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1071 18 Station System Parameters Call Coverage/Call Forwarding System Parameters Country-Options System Parameters Crisis Alert Action Object Qualifier add stationextension (or ‘next’) change station extension display station extension [’print’ or ’schedule’] Action Object Qualifier change system-parameters coverage-forwarding — display system-parameters coverage-forwarding [’print’ or ’schedule’] Action Object Qualifier display system-parameters country-options [’print’ or ’schedule’] Action Object Qualifier change system-parameters crisis-alert — display system-parameters crisis-alert [’print’ or ’schedule’]
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1072 18 System Parameters Customer-Options Telecommuting Access Tenant Terminal Parameters Action Object Qualifier display system-parameters customer-options[’print’ or ’schedule’] Action Object Qualifier add telecommuting-access change telecommuting-access display telecommuting-access x[print or schedule] remove telecommuting-access Action Object Qualifier change tenant x display tenant x[print or schedule] Action Object Qualifier display terminal-parameters 603/606/302B1 [print’ or ’schedule’] display terminal-parameters 8400 [‘print’ or ’schedule’] display terminal-parameters 6400 [‘print’ or ’schedule’]
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1073 18 Terminating Extension Group Time of Day Coverage Table Time of Day Routing Plan Action Object Qualifier add term-ext-group1-32 (or ‘next’) change term-ext-group 1-32 display term-ext-group 1-32 [’print’ or’ schedule’] list term-ext-group [1-32][’number’ x][’to-number’ x] [’name’ x][’ext’ x][’to-ext’ x][’count’ n] [’print’ or ’schedule’] remove term-ext-group 1-32 Action Object Qualifier add coverage time-of-day 1 - 999 change coverage time-of-day 1 - 999 display coverage time-of-day 1 - 999 remove coverage time-of-day 1 - 999 Action Object Qualifier display time-of-day [‘print’ or ‘schedule’] display time-of-day 1-MAX (plan number) [’print’ or ’schedule’] change time-of-day [time of day routing plan (1-MAX)]
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Command reference 1074 18 Toll Analysis Trunk Groups Vector Directory Numbers Action Object Qualifier change tollEnter digits between 0-9, ‘x’, or ‘X’ [‘min’ 1-23] display toll Enter digits between 0-9, ‘x’, or ‘X’ [‘min’ 1-23] [’print’ or ‘schedule’] list toll toll-list [‘start’ dialed-string] [‘count’ (1-1000)] [‘print’ or ‘schedule’] list toll all [‘start’ dialed-string] [‘count’ (1-1000)] [‘print’ or ‘schedule’] list toll restricted-call[‘start’ dialed-string] [‘count’ (1-1000)] [‘print’ or ‘schedule’] list toll unrestricted- call [1-10][‘start’ dialed-string] [‘count’ (1-1000)] [‘print’ or ‘schedule’] Action Object Qualifier add trunk-group 1–MAX (or ‘next’) change trunk-group 1–MAX or TAC X... display trunk-group 1–MAX [’number’ X][’to-number’ X][’count’ N] [’tac’ assigned TAC][’print’ or ’schedule’] list trunk-group [’print’ or ’schedule’] remove trunk-group 1–MAX or TAC X... Action Object Qualifier add vdn extension (or ‘next’) change vdn extension display vdn extension [’print’ or ’schedule’]
Phone reference 1075 19 DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 19 Phone reference This reference section describes many of the telephones and adjuncts that you can connect to the DEFINITY ECS. Use this section to: ndetermine where to connect a phone—is it analog, digital, or hybrid? is it designed for a 2-wire or 4-wire environment? ndetermine whether a phone will fit your users’ needs—does it accommodate enough feature buttons? does it include a display? nunderstand how to assign the user’s feature buttons—how do the buttons on the Station screen map to buttons on the physical phone. Because you need to know how the physical buttons on the phone relate to your button assignments on the Station screen, this section includes figures for those phones to which you can assign feature buttons. If you want more information about a particular phone or see a diagram of a phone that is not pictured in this section, refer to the DEFINITY ECS Terminals and Adjuncts Reference. This section includes descriptions of the following telephones: nMultibutton Electronic telephones (MET phones) (page 1076) n500 telephones (page 1077) n2500-series telephones (page 1077) n6200-series telephones (page 1077) n6400-series telephones (page 1081) n7100-series telephones (page 1085)
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Phone reference 1076 Multibutton electronic telephones 19 n7300-series telephones (page 1085) n731x-series hybrid telephones (page 1089) n7400-series telephones (page 1094) nISDN telephones (7500-series & 8500-series) (page 1110) n8110 telephones (page 1115) n8400-series telephones (page 1115) nCALLMASTER telephones (page 1122) nCordless telephones (page 1126) nInternet Protocol (IP) SoftPhones (page 1129) Multibutton electronic telephones 10-MET telephone The 10-multibutton electronic telephones (MET) are basic phones that have 10 feature buttons. You can assign call-appearances or features to the first five buttons. The last 5 buttons are fixed features. 20-MET telephone The 20-multibutton electronic telephones (MET) are basic phones that provide up to 20 feature buttons. You can assign call-appearances or features to the top five buttons in the first column. The bottom 5 buttons in the first column are fixed feature buttons that you cannot change. However, you can assign features to the second column of buttons (10); these correspond to feature button assignments 1 through 10 on the switch. 30-MET telephone The 30-multibutton electronic telephones (MET) are basic phones that provide up to 30 feature buttons. You can assign call-appearances or features to the top five buttons in the first column. The bottom 5 buttons in the first column are fixed feature buttons that you cannot change. However, you can assign features to the second column (1 to 10) and third column of buttons (11 to 20); these correspond to feature button assignments 1 through 20 on the switch.