Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 887 Security-Related System Parameters 17 Number of Digits This field tells the system how many digits to collect if the first and second digits match. Enter the length of the dialed number. Security-Related System Parameters You use this screen to determine when the switch reports a security violation. Many of the fields on this screen repeat for each type of security violation. We have explained them once here, but the usage is the same for all. Refer to ‘‘ Security violations notification’’ on page 1491 for more information on security violations notification. Field descriptions for page 1 Screen 181. Security-Related System Parameters Valid entries Usage 2 For attd 2 through 5For aar, ars, and extension 2 through 4For tac (2 and 3 with DCS) 2 through 4For fac change system-parameters security Page 1 of 2 SECURITY-RELATED SYSTEM PARAMETERS SECURITY VIOLATION NOTIFICATION PARAMETERS SVN Login Violation Notification Enabled? y Originating Extension: _____ Referral Destination: _____ Login Threshold: 5_ Time Interval: 0:03 Announcement Extension: _____ SVN Remote Access Violation Notification Enabled? y Originating Extension: _____ Referral Destination: _____ Barrier Code Threshold: 10 Time Interval: 0:03 Announcement Extension: _____ SVN Authorization Code Violation Notification Enabled? y Originating Extension: _____ Referral Destination: _____ Authorization Code Threshold: 10 Time Interval: 0:03 Announcement Extension: _____
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 888 Security-Related System Parameters 17 SVN Login (Remote Access, AutoStation Security Code, Violation Notification Enabled Originating Extension The originating extension initiates the referral call in the event of a security violation. It also sends the appropriate alerting message or display to the referral destination. Referral Destination The referral destination receives the referral call when a security violation occurs. The referral destination telephone must have a display, unless the you assign an Announcement Extension. Valid entries Usage y/n Set to y if you want the switch to notify you when a login violation occurs. If this field is y, the next 5 fields appear so you can establish the parameters for what is considered a security violation. Valid entries Usage An unassigned extensionIf you establish notification for more than one type of security violations, you must assign a different extension to each one. When the switch generations a referral call, this extension and the type of violation appear on the display at the referral destination. Valid entries Usage An extension Enter the extension of the telephone, attendant console, or vector directory number (VDN) that you want to receive the referral call for each type of violation. This can be the same extension for all type of violations. If you use a VDN, you must complete the Announcement Extension field. You can also use Call Vectoring Time-of-Day routing to route the referral call to different destinations based on the time of day or the day of the week.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 889 Security-Related System Parameters 17 Login (Barrier Code, Authorization Code Security Code) Threshold The value assigned to this field, in conjunction with Time Interval, determines whether a security violation has occurred. For example, if this field is 5, and time interval is 0:03, then five invalid access attempts within three minutes constitutes a security violation. Time Interval The value of this field, in conjunction with Threshold, determines whether a security violation has occurred. Announcement Extension If you enter a value in this field, the switch calls the referral destination, then plays this announcement upon answer. SVN Remote Access Violation Notification Enabled Use these fields to establish parameters for remote access security violations. A remote access violation occurs if a user enters incorrect barrier codes. You cannot set the system to disable remote access following a security violation unless you have turned this on here. Valid entries Usage 1–99, 1–255 for Station Security codeEnter the number of access attempts that are permitted before a referral call is made. In general, it is good to keep this number low. If you are doing testing and do not want to generate alarms, you might change this threshold temporarily. Valid entries Usage 0:01 to 7:59The range for the time interval is one minute to eight hours. Entered in the screen “x:xx.” For example, if you want the time interval to be one minute, you enter 0:01. If you want the time interval to be seven and one-half hours, you enter 7:30. Valid entries Usage Valid extension The announcement extension where SVN violation announcement resides.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 890 Security-Related System Parameters 17 SVN Authorization Code Violation Notification Enabled Field descriptions for page 2 Screen 182. Security-Related System Parameters for G3r Screen 183. Security-Related System Parameters for G3si and G3csi change system-parameters security Page 2 of 2 SECURITY-RELATED SYSTEM PARAMETERS SECURITY VIOLATION NOTIFICATION PARAMETERS SVN Station Security Code Violation Notification Enabled? y Originating Extension: _____ Referral Destination: _____ Station Security Code Threshold: 10 Time Interval: 0:03 Announcement Extension: _____ STATION SECURITY CODE VERIFICATION PARAMETERS Minimum Station Security Code Length: 4 Security Code for Terminal Self Administration Required? y ACCESS SECURITY GATEWAY PARAMETERS SYSAM-LCL? n SYSAM-RMT? n MAINT? n SYS-PORT? n Translation-ID Number Mismatch Interval (days): _ change system-parameters security Page 2 of 2 SECURITY-RELATED SYSTEM PARAMETERS SECURITY VIOLATION NOTIFICATION PARAMETERS SVN Station Security Code Violation Notification Enabled? y Originating Extension: _____ Referral Destination: _____ Station Security Code Threshold: 10 Time Interval: 0:03 Announcement Extension: _____ STATION SECURITY CODE VERIFICATION PARAMETERS Minimum Station Security Code Length: 4 Security Code for Terminal Self Administration Required? y ACCESS SECURITY GATEWAY PARAMETERS MGR1? n INADS? n EPN? n NET? n
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 891 Security-Related System Parameters 17 SVN Station Security Code Violation Notification Enabled Station Security codes are used to validate logins to a particular extension (for example, a home agent using an extender, or two part-time workers using the same telephone, but different extensions, through personal station access.) Enter y here to establish parameters for this. Minimum Station Security Code Length This determines the minimum required length of the Station Security Codes that you enter on the Station screen. Security Code for Terminal Self Administration Required Access Security Gateway Parameters These eight fields appear only if the Access Security Gateway (ASG) field on the System-Parameters Customer-Options screen is y. The following 4 fields display only for the G3r version: SYSAM-LCL A direct cable connection to the SYSAM-LCL G3-MT (local system administrator’s terminal) port on the System Access and Maintenance circuit pack on the active G3r processor carrier. For more information on the circuit pack, refer to the DEFINITY ECS System Description. Valid entries Usage 3–8 Longer codes are more secure. If station security codes are used for external access to telecommuting features, the minimum length should be 7 or 8. Valid entries Usage y/n Enter y to indicate that a security code is required. Valid entries Usage y/n Any entry attempt through this port receives a challenge response.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 892 Security-Related System Parameters 17 SYSAM-RMT A dialed-in (or out) connection to the SYSAM-RMT port on the System Access and Maintenance circuit pack in the active G3r processor carrier. For more information on the circuit pack, refer to the DEFINITY ECS System Description. MAINT A direct connection to the EPN maintenance circuit pack RS-232 interface. SYS-PORT A dialed-in (or out) connection to the System Access Port. The following fields display only for the G3si and G3csi versions: MGR1 The direct connect system administration and maintenance access interface located on the processor circuit pack. For more information on the circuit pack, refer to the DEFINITY ECS System Description. INADS A direct cable connection to the Initialization and Administration System used to remotely initialize and administer DEFINITY ECS. Valid entries Usage y/n Any entry attempt through this port receives a challenge response. Valid entries Usage y/n Any entry attempt through this port receives a challenge response. Valid entries Usage y/n Any entry attempt through this port receives a challenge response. Valid entries Usage y/n Any entry attempt through this port receives a challenge response. Valid entries Usage y/n Any entry attempt through this port receives a challenge response.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 893 Security-Related System Parameters 17 EPN A direct connection to the Expansion Port Network. NET A dialed-in (or out) connection to the Network Controller circuit pack. For more information on the circuit pack, refer to the DEFINITY ECS System Description. Translation-ID Number Mismatch Interval (days) A display-only field for all logins except init; only init logins can change this field. This field specifies the interval (in days) that the system allows a mismatch between the translation ID stored in the Processor circuit pack(s) and on the flash card. Following expiration of this interval, the ability to execute system administration commands that modify translation data is denied for all logins, except for init. Valid entries Usage y/n Any entry attempt through this port receives a challenge response. Valid entries Usage y/n Any entry attempt through this port receives a challenge response. Valid entries Usage 1-90 Enter a number to indicate the number of days the system allows access to system administration commands.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 894 Site Data 17 Site Data Use this screen to enter information about buildings, floors and telephone set colors. You must supply values on this screen before you can enter information in the Site Data section of the Station screen. Field descriptions for pages 1, 2 and 3 These pages are available for you to enter descriptive information about the buildings, floors and phone set colors. You may enter any valid keyboard character. If you want to indicate that a particular floor is in a particular building, you must include this in the floor entry, for example, B301-Fl4. Station This section provides descriptions of all of the fields that may appear on Station screens. Some of the fields are used for specific phone types; others are used for all phone types. To make it easier to find a specific field, they are listed in alphabetical order by field name. Screen 184. Station change site-data SITE DATA USER DEFINITION VALID BUILDING FIELDS _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ _________ add station 1014 Page 1 of X STATION Extension: 1014 Lock Messages? n BCC: 0 Type: 6408D+ Security Code: ______ TN: 1 Port: _____ Coverage Path 1: ___ COR: 1 Name: __________________________ Coverage Path 2: ___ COS: 1 Hunt-to-Station: ____ STATION OPTIONS Loss Group: _ Personalized Ringing Pattern: 1 Data Module? n Message Lamp Ext: 1014 Speakerphone: 2-way Mute button enabled? y Display Language? English Media Complex Ext: IP Softphone? n
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 895 Station 17 Screen 185. Station Screen 186. Station The standard station fields are organized alphabetically for easy access. 1-Step Clearing Valid entries Usage y/n If set to y, the call terminates again at the WCBRI terminal when the user drops from the call. add station 1014 Page 2 of X STATION FEATURE OPTIONS LWC Reception? msa-spe Auto Select Any Idle Appearance? n LWC Activation? y Coverage Msg Retrieval? y LWC Log External Calls? n Auto Answer: none CDR Privacy? n Data Restriction? n Redirect Notification? y Idle Appearance Preference? n Per Button Ring Control? n Bridged Call Alerting? n Restrict Last Appearance? y Active Station Ringing: single H.320 Conversion? n Per Station CPN - Send Calling Number? _ Service Link Mode: as-needed Special Character for Restricted Number? n Multimedia Mode: basic MWI Served User Type: ______ Display Client Redirection? n AUDIX Name: Select Last Used Appearance? n Messaging Server Name: ______ Coverage After Forwarding? _ Recall Rotary Digit? n Multimedia Early Answer? n add station 1014 Page 3 of X STATION SITE DATA Room: _______ Headset? n Jack: ___ Speaker? n Cable: ___ Mounting: d Floor: _______ Cord Length: 0_ Building: _______ Set Color: _____ ABBREVIATED DIALING List1: ________ List2: _________ List3: _________ BUTTON ASSIGNMENTS 1: call-appr 5: ________ 2: call-appr 6: ________ 3: call-appr 7: ________ 4: ________ 8: ________
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 896 Station 17 Abbreviated Dialing List1, List2, List3 You can assign up to 3 abbreviated dialing lists to each phone. Active Station Ringing Defines how call rings to the phone when it is off-hook. This field does not affect how calls ring at this phone when the phone is on-hook. Valid entries Usage enhanced Allows the phone user to access the enhanced system abbreviated dialing list. groupAllows the phone user to access the specified group abbreviated dialing list. If you enter group, you also must enter a group number. personalAllows the phone user to access and program their personal abbreviated dialing list. If you enter personal, you also must enter a personal list number. systemAllows the phone user to access the system abbreviated dialing list. Valid entries Usage continuous Enter continuous to cause all calls to this phone to ring continuously. single Enter single to cause calls to this phone to receive one ring cycle and then ring silently. if-busy-singleEnter if-busy-single to cause calls to this phone to ring continuously when the phone is off-hook and idle and calls to this phone to receive one ring cycle and then ring silently when the phone is off-hook and active. silentEnter silent to cause all calls to this station to just ring silently.