    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1718
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    887 Security-Related System Parameters 
    17
    Number of Digits
    This field tells the system how many digits to collect if the first and second digits 
    match. Enter the length of the dialed number.
    Security-Related System Parameters
    You use this screen to determine when the switch reports a security violation. 
    Many of the fields on this screen repeat for each type of security violation. We 
    have explained them once here, but the usage is the same for all. Refer to 
    ‘‘
    Security violations notification’’ on page 1491 for more information on security 
    violations notification.
    Field descriptions for page 1
    Screen 181. Security-Related System Parameters Valid entries Usage
    2
     For attd
    2 through 5For aar, ars, and extension
    2 through 4For tac (2 and 3 with DCS)
    2 through 4For fac
    change system-parameters security Page 1 of 2
    SECURITY-RELATED SYSTEM PARAMETERS
    SECURITY VIOLATION NOTIFICATION PARAMETERS
    SVN Login Violation Notification Enabled? y
    Originating Extension: _____ Referral Destination: _____
    Login Threshold: 5_  Time Interval: 0:03
    Announcement Extension: _____
    SVN Remote Access Violation Notification Enabled? y
    Originating Extension: _____ Referral Destination: _____
    Barrier Code Threshold: 10  Time Interval: 0:03
    Announcement Extension: _____
    SVN Authorization Code Violation Notification Enabled? y
    Originating Extension: _____ Referral Destination: _____
    Authorization Code Threshold: 10  Time Interval: 0:03
    Announcement Extension: _____ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    888 Security-Related System Parameters 
    17
    SVN Login (Remote Access, AutoStation 
    Security Code, Violation Notification Enabled
    Originating Extension
    The originating extension initiates the referral call in the event of a security 
    violation. It also sends the appropriate alerting message or display to the referral 
    destination.
    Referral Destination
    The referral destination receives the referral call when a security violation occurs. 
    The referral destination telephone must have a display, unless the you assign an 
    Announcement Extension. 
    Valid entries Usage
    y/n
    Set to y if you want the switch to notify you when a login 
    violation occurs. If this field is 
    y, the next 5 fields appear so 
    you can establish the parameters for what is considered a 
    security violation.
    Valid entries Usage
    An unassigned 
    extensionIf you establish notification for more than one type of security 
    violations, you must assign a different extension to each one. 
    When the switch generations a referral call, this extension and 
    the type of violation appear on the display at the referral 
    destination.
    Valid entries Usage
    An extension Enter the extension of the telephone, attendant console, or 
    vector directory number (VDN) that you want to receive the 
    referral call for each type of violation. This can be the same 
    extension for all type of violations.
    If you use a VDN, you must complete the Announcement 
    Extension field. You can also use Call Vectoring Time-of-Day 
    routing to route the referral call to different destinations based 
    on the time of day or the day of the week.  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    889 Security-Related System Parameters 
    17
    Login (Barrier Code, Authorization Code 
    Security Code) Threshold
    The value assigned to this field, in conjunction with Time Interval, determines 
    whether a security violation has occurred. For example, if this field is 5, and time 
    interval is 0:03, then five invalid access attempts within three minutes constitutes 
    a security violation. 
    Time Interval
    The value of this field, in conjunction with Threshold, determines whether a 
    security violation has occurred.
    Announcement Extension
    If you enter a value in this field, the switch calls the referral destination, then plays 
    this announcement upon answer.
    SVN Remote Access Violation Notification 
    Enabled
    Use these fields to establish parameters for remote access security violations. A 
    remote access violation occurs if a user enters incorrect barrier codes. You cannot 
    set the system to disable remote access following a security violation unless you 
    have turned this on here. 
    Valid entries Usage
    1–99, 1–255
     for 
    Station Security 
    codeEnter the number of access attempts that are permitted before a 
    referral call is made. In general, it is good to keep this number 
    low. If you are doing testing and do not want to generate 
    alarms, you might change this threshold temporarily.
    Valid entries Usage
    0:01
     to 7:59The range for the time interval is one minute to eight hours. 
    Entered in the screen “x:xx.” For example, if you want the time 
    interval to be one minute, you enter 0:01. If you want the time 
    interval to be seven and one-half hours, you enter 7:30. 
    Valid entries Usage
    Valid extension The announcement extension where SVN 
    violation announcement resides.  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    890 Security-Related System Parameters 
    17
    SVN Authorization Code Violation Notification 
    Enabled
    Field descriptions for page 2
    Screen 182. Security-Related System Parameters for G3r 
    Screen 183. Security-Related System Parameters for G3si and G3csi 
    change system-parameters security     Page 2 of 2
        SECURITY-RELATED SYSTEM PARAMETERS
    SECURITY VIOLATION NOTIFICATION PARAMETERS
    SVN Station Security Code Violation Notification Enabled? y
    Originating Extension: _____  Referral Destination: _____
    Station Security Code Threshold: 10 Time Interval: 0:03
    Announcement Extension: _____
    STATION SECURITY CODE VERIFICATION PARAMETERS
    Minimum Station Security Code Length: 4
    Security Code for Terminal Self Administration Required? y
    ACCESS SECURITY GATEWAY PARAMETERS
    SYSAM-LCL? n SYSAM-RMT? n
    MAINT? n       SYS-PORT? n
      Translation-ID Number Mismatch Interval (days): _
    change system-parameters security Page 2 of 2
        SECURITY-RELATED SYSTEM PARAMETERS
    SECURITY VIOLATION NOTIFICATION PARAMETERS
    SVN Station Security Code Violation Notification Enabled? y
    Originating Extension: _____  Referral Destination: _____
    Station Security Code Threshold: 10 Time Interval: 0:03
    Announcement Extension: _____
    STATION SECURITY CODE VERIFICATION PARAMETERS
                       Minimum Station Security Code Length: 4
    Security Code for Terminal Self Administration Required? y
    ACCESS SECURITY GATEWAY PARAMETERS
        MGR1? n INADS? n
     EPN? n      NET? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    891 Security-Related System Parameters 
    17
    SVN Station Security Code Violation 
    Notification Enabled
    Station Security codes are used to validate logins to a particular extension (for 
    example, a home agent using an extender, or two part-time workers using the 
    same telephone, but different extensions, through personal station access.) Enter 
    y 
    here to establish parameters for this.
    Minimum Station Security Code Length
    This determines the minimum required length of the Station Security Codes that 
    you enter on the Station screen.
    Security Code for Terminal Self Administration 
    Required
    Access Security Gateway Parameters
    These eight fields appear only if the Access Security Gateway (ASG) field on the 
    System-Parameters Customer-Options screen is 
    y. 
    The following 4 fields display only for the G3r version:
    SYSAM-LCL 
    A direct cable connection to the SYSAM-LCL G3-MT (local system 
    administrator’s terminal) port on the System Access and Maintenance circuit pack 
    on the active G3r processor carrier. For more information on the circuit pack, refer 
    to the DEFINITY ECS System Description.
    Valid entries Usage
    3–8
    Longer codes are more secure. If station security codes are 
    used for external access to telecommuting features, the 
    minimum length should be 7 or 8.
    Valid entries Usage
    y/n
    Enter y to indicate that a security code is required.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    892 Security-Related System Parameters 
    17
    SYSAM-RMT 
    A dialed-in (or out) connection to the SYSAM-RMT port on the System Access 
    and Maintenance circuit pack in the active G3r processor carrier. For more 
    information on the circuit pack, refer to the DEFINITY ECS System Description. 
    MAINT 
    A direct connection to the EPN maintenance circuit pack RS-232 interface.
    SYS-PORT 
    A dialed-in (or out) connection to the System Access Port.
    The following fields display only for the G3si and G3csi versions:
    MGR1 
    The direct connect system administration and maintenance access interface 
    located on the processor circuit pack. For more information on the circuit pack, 
    refer to the DEFINITY ECS System Description.
    INADS 
    A direct cable connection to the Initialization and Administration System used to 
    remotely initialize and administer DEFINITY ECS.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
      Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    893 Security-Related System Parameters 
    17
    EPN 
    A direct connection to the Expansion Port Network.
    NET 
    A dialed-in (or out) connection to the Network Controller circuit pack. For more 
    information on the circuit pack, refer to the DEFINITY ECS System Description.
    Translation-ID Number Mismatch Interval (days)
    A display-only field for all logins except init; only init logins can change this 
    field. This field specifies the interval (in days) that the system allows a mismatch 
    between the translation ID stored in the Processor circuit pack(s) and on the flash 
    card. Following expiration of this interval, the ability to execute system 
    administration commands that modify translation data is denied for all logins, 
    except for init.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    y/n
    Any entry attempt through this port receives a challenge 
    response.
    Valid entries Usage
    1-90
    Enter a number to indicate the number of days the system 
    allows access to system administration commands. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    894 Site Data 
    17
    Site Data
    Use this screen to enter information about buildings, floors and telephone set 
    colors. You must supply values on this screen before you can enter information in 
    the Site Data section of the Station screen.
    Field descriptions for pages 1, 2 and 3
    These pages are available for you to enter descriptive information about the 
    buildings, floors and phone set colors. You may enter any valid keyboard 
    character. If you want to indicate that a particular floor is in a particular building, 
    you must include this in the floor entry, for example, B301-Fl4.
    Station
    This section provides descriptions of all of the fields that may appear on Station 
    screens. Some of the fields are used for specific phone types; others are used for 
    all phone types. To make it easier to find a specific field, they are listed in 
    alphabetical order by field name.
    Screen 184. Station
    change site-data
    SITE DATA USER DEFINITION
    VALID BUILDING FIELDS 
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    _________ _________ _________ _________ _________
    add station 1014 Page 1 of X
                                              STATION
    Extension: 1014                                Lock Messages? n       BCC: 0
    Type: 6408D+                         Security Code: ______   TN: 1
    Port: _____ Coverage Path 1: ___     COR: 1
        Name: __________________________  Coverage Path 2: ___     COS: 1
                                                 Hunt-to-Station: ____
    STATION OPTIONS
                  Loss Group: _ Personalized Ringing Pattern: 1
    Data Module? n   Message Lamp Ext: 1014
    Speakerphone: 2-way  Mute button enabled? y
    Display Language? English
                                                            Media Complex Ext: 
                                                                 IP Softphone? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    895 Station 
    17
    Screen 185. Station 
    Screen 186. Station 
    The standard station fields are organized alphabetically for easy access.
    1-Step Clearing
    Valid entries Usage
    y/n
    If set to y, the call terminates again at the WCBRI terminal 
    when the user drops from the call.
    add station 1014 Page 2 of X
    STATION
    FEATURE OPTIONS
    LWC Reception? msa-spe  Auto Select Any Idle Appearance? n
             LWC Activation? y  Coverage Msg Retrieval? y
    LWC Log External Calls? n Auto Answer: none
        CDR Privacy? n    Data Restriction? n
      Redirect Notification? y   Idle Appearance Preference? n
    Per Button Ring Control? n
    Bridged Call Alerting? n       Restrict Last Appearance? y
    Active Station Ringing: single
            H.320 Conversion? n Per Station CPN - Send Calling Number? _
    Service Link Mode: as-needed Special Character for Restricted Number? n
    Multimedia Mode: basic
    MWI Served User Type: ______   Display Client Redirection? n
    AUDIX Name: Select Last Used Appearance? n
    Messaging Server Name: ______ Coverage After Forwarding? _
    Recall Rotary Digit? n  Multimedia Early Answer? n
    add station 1014 Page 3 of X
    STATION
         SITE DATA
              Room: _______                                      Headset? n
              Jack: ___                                          Speaker? n
             Cable: ___                                         Mounting: d
             Floor: _______                                  Cord Length: 0_
          Building: _______                                    Set Color: _____
    ABBREVIATED DIALING
         List1: ________           List2: _________          List3: _________
    BUTTON ASSIGNMENTS
     1: call-appr  5: ________
     2: call-appr  6: ________
     3: call-appr  7: ________
    4: ________ 8: ________ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    896 Station 
    17
    Abbreviated Dialing List1, List2, List3
    You can assign up to 3 abbreviated dialing lists to each phone.
    Active Station Ringing
    Defines how call rings to the phone when it is off-hook. This field does not affect 
    how calls ring at this phone when the phone is on-hook.
    Valid entries Usage
    enhanced
    Allows the phone user to access the enhanced system 
    abbreviated dialing list.
    groupAllows the phone user to access the specified group 
    abbreviated dialing list. If you enter 
    group, you also must enter 
    a group number.
    personalAllows the phone user to access and program their personal 
    abbreviated dialing list. If you enter 
    personal, you also must 
    enter a personal list number.
    systemAllows the phone user to access the system abbreviated dialing 
    list.
    Valid entries Usage
    continuous
    Enter continuous to cause all calls to this phone to ring 
    continuously.
    single Enter single to cause calls to this phone to receive one ring 
    cycle and then ring silently.
    if-busy-singleEnter if-busy-single to cause calls to this phone to ring 
    continuously when the phone is off-hook and idle and calls to 
    this phone to receive one ring cycle and then ring silently when 
    the phone is off-hook and active.
    silentEnter silent to cause all calls to this station to just ring silently. 
    						