    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1718
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    787 ISDN Numbering — Public/ Unknown 
    17
    ISDN Numbering — Public/ Unknown 
    This screen supports the ISDN Call Identification Display feature. The feature 
    provides a name/number display for display-equipped stations within an ISDN 
    network. The system uses the caller’s name and number and displays it on the 
    called party’s display. Likewise, the called party’s name and number can be 
    displayed on the caller’s display.
    The screen allows you to specify the desired digits for the Calling Number IE and 
    the Connected Number IE (in addition to the QSIG Party Number) for any 
    extension in the Public and/or Unknown Number Plans.
    Administer these screens if either the Send Calling Number, Send Connected 
    Number field is specified, or the Supplementary Service Protocol field is 
    b on the 
    trunk group screen.
    NOTE:
    If the table is not properly administered and the Send Calling Number or 
    Send Connected Number field is 
    y or r and the Numbering Format field on 
    the ISDN Trunk Group screen is 
    public or unknown, the Calling Number 
    and Connected Number IE are not sent. If the table is not administered, but 
    the Send Calling Number or Send Connected Number field is 
    public or 
    unknown, the Identification Number (PartyNumber data type) is not sent 
    for QSIG PartyNumbers. In this case, the ASN.1 data type containing the 
    PartyNumber (PresentedAddressScreened, PresentedAddressUnscreened, 
    PresentedNumberScreened, or PresentedNumberUnscreened) will be sent 
    marked as “PresentationRestricted” with “NULL” for the associated digits.
    Screen 123. ISDN Numbering Public/Unknown 
    change isdn public-unknown-numbering                            Page 1 of 8
    ISDN NUMBERING - PUBLIC/UNKNOWN FORMAT
                                    
    Ext Ext   Trk     CPN       Total CPN   Ext  Ext    Trk     CPN       Total CPN
    Len Code  Grp(s)  Prefix          Len   Len  Code   Grp(s)  Prefix          Len
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
     _  _____ _______ _______________  __     _  _____  _______ _______________  __  
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    788 ISDN Numbering — Public/ Unknown 
    17
    Ext Len
    Specifies the number of digits the extension can have.
    Ext Code
    Allows for groups of extensions to be administered.
    NOTE:
    When 0 alone is entered, the Ext Len field must be 1 and the DDD number 
    must be 10-digits.
    Trk Grp(s)
    The switch generates the station’s identification number if there is an entry in the 
    Ext Code field, and this field is administered with the trunk group number 
    carrying the call.
    Valid entries Usage
    0
     to 5  Corresponds to the extension lengths allowed by 
    the dial plan.
    Valid entries Usage
    0
     to 9The Ext Code can be up to 5-digits long depending on the Ext 
    Len field entry. The entry cannot be greater than the Ext Len 
    field entry. For example, in the case of a 4-digit Ext Len field 
    entry, an Ext Code of 12 is the equivalent of all extensions of 
    the screen 12xx, excluding any explicitly listed longer codes. 
    If a code of 123 is also listed, the 12 code is equivalent of all 
    extensions of the screen 12xx except extensions of the screen 
    123x. The coding precludes having to list all the applicable 
    12xx extensions.
    attdFor attendant
    Valid entries Usage
    1 to 7 digits Enter the valid administered ISDN trunk-group number or a 
    range of group numbers. For example, if trunk groups 10 
    through 24 use the same CPN Prefix, enter 
    10-24.
    blank The identification numbers are not dependent on which trunk 
    group the call is carried. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    789 ISDN Numbering — Public/ Unknown 
    17
    CPN Prefix
    Use this field to specify the number that is added to the beginning of the extension 
    to form a Calling or Connected Number.
    Total CPN Len
    Valid entries Usage
    1 to 15 digits Only digits are allowed in the CPN Prefix column.  Leading 
    spaces, or spaces in between the digits, are not allowed.
    nIf the length of the CPN Prefix matches the Total CPN 
    Length, the extension number is not used to formulate the 
    CPN number.
    nIf the number of digits in the CPN Prefix plus the extension 
    length exceeds the administered Total CPN Length, excess 
    leading digits of the extension are deleted when 
    formulating the CPN number. 
    nIf the number of CPN Prefix digits plus the extension 
    length is less than the Total CPN Length, the entry is not 
    allowed. 
    nIf the Total CPN Length is 0, no calling party number 
    information is provided to the called party and no 
    connected party number information is provided to the 
    calling party.
    blank If this field is blank, the extension is sent unchanged. This is 
    useful in countries where the public network is able to insert 
    the appropriate CPN Prefix to form an external DID number.
    Valid entries Usage
    0
     to 15Enter the total number of digits to send. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    790 ISDN-BRI Trunk Circuit Pack 
    17
    ISDN-BRI Trunk Circuit Pack
    This screen administers an ISDN-BRI circuit pack. See DEFINITY ECS System 
    Description for information on the maximum number of ISDN-BRI circuit packs 
    that you can administer.
    Screen 124. BRI Trunk (using a TN2185 circuit pack)
    Location
    This is a display-only field. It shows the TN2185 circuit pack location (PPCSS)
    Name
    Interface Companding
    Valid entries Usage
    1–15 
    alpha-numeric 
    characters This name is used to identify the circuit pack.
    Valid entries Usage
    a-law
       Indicates the companding algorithm expected by the system at 
    the far end.
    mu-law
    change bri-trunk-board                                             Page 1 of 1
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
                  Location: 01A09                           Name:  ______________
      Interface Companding: a-law_  DCP/Analog Bearer Capability: 3.1kHz
     T3 Timer Length (sec): 15_             
    Port  Interface  Side  Cntry/Peer TEI  Time  Invert Synch   Layer 1  Detect
                            Protocol       Fill  Bits?  Source? Stable?  Slips?
      1:  user_______        12__     0__  flags   n       n       n       n
      2:  network____  etsi     0__  ones_   y       y       y       y
      3:  user_______        2___  auto flags   y       n       y       n
      4:  peer-slave_  b     QSIG     0__  flags   n       y       y       n
      5:  peer-master  a     QSIG  auto ones_   n       n       n       n
      6:  ___________        ____     0__  ones_   n       n       y       n
      7.  ___________        ____     0__  ones_   n       n       y       n
      8:  ___________        ____     0__  ones_   n       n       y       n
       
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    791 ISDN-BRI Trunk Circuit Pack 
    17
    DCP/Analog Bearer Capability
    T3 Timer Length (sec)
    Port
    This is a display-only field. It shows the port number to which parameters 
    administered on the row apply.
    Interface
    Side
    Valid entries Usage
     3.1kHz   Indicates how to encode the Bearer Capability IE for an 
    outgoing call originated by a DCP or analog endpoint.
    speech
    Valid entries Usage
    1
     to 127  Tells the TE side how long to wait, in seconds, for an inactive 
    Layer 1 to become active.
    Valid entries Usage
    network
    Tells call processing software whether a particular port is 
    connected to a user/network or a peer interface. These entries 
    are valid for the TN2185. You can enter 
    peer-slave only if the 
    QSIG Basic Call Setup feature is enableduser
    peer-master
    peer-slave
    Valid entries Usage
    a
      Determines how glare conditions are handled when Interface 
    field is 
    peer-slave.b 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    792 ISDN-BRI Trunk Circuit Pack 
    17
    Cntry/Peer Protocol
    Tells call processing software which ISDN protocol standard is applied.
    TEI
    Time Fill
    The bit pattern sent on the D-channel between valid LAPD packets.
    Invert Bits
    Synch Source
    Valid entries Usage
    1
     to 25When this field is 10, 12, 13, or etsi, the Protocol Version 
    field is equivalent to 
    b on the DS1 circuit pack screen. When 
    the Cntry/Peer Protocol field is set 
    10, 12, 13, or etsi, set the 
    Provol Version field to 
    b. For all other administered values, 
    the Protocol Version sets to 
    a.
    etsi
    QSIG
    When the Interface field is peer-slave or peer-master, this 
    field must be 
    QSIG. The choice QSIG is valid only when the 
    Interface field is 
    peer-slave.
    blank You cannot leave this field blank if the Interface field is set to 
    a valid, non-blank value
    Valid entries Usage
    auto
    0
    Valid entries Usage
    flags
     
    ones 
    Valid entries Usage
    y/n
    Valid entries Usage
    y
    n
      
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    793 ISDN-BRI Trunk Circuit Pack 
    17
    Layer 1 Stable
    Detect Slips
    Field descriptions for page 1
    Screen 125. BRI Trunk (with a TN556B or TN2198 circuit pack)
    The following field descriptions are unique to the ISDN-BRI Circuit Pack screen 
    with a TN556B or TN2198 circuit pack. The following fields do not display with 
    a TN556B or TN2198 circuit pack:
    nT3 Timer Length (sec)
    nSynch Source
    nLayer 1 Stable
    nDetect Slips
    Valid entries Usage
    y
      Tells call processing and maintenance software whether to 
    expect the network to drop Layer 1 when the BRI port is idle. 
    Only the TN2185 may be set to 
    n.n
    Valid entries Usage
    y/n
    Tells maintenance software whether slips reported by the BRI 
    port should be logged.
    change bri-trunk-board                                       Page 1 of 1
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
                   Location: 01A09                   Name:  ______________
       Interface Companding: a-law_  DCP/Analog Bearer Capability: 3.1kHz
    Port  Interface   Side  Cntry/Peer TEI  Time Invert 
                            Protocol        Fill  Bits? 
      1:  network__           12__     0__  flags   n   
      2:  network__           etsi     0__  ones_   y   
      3:  network__           2___     auto flags   y   
      4:  peer-master  b      QSIG     0__  flags   n   
      5:  peer-master  a      QSIG     auto ones_   n   
      6:  __________          ____     0__  ones_   n   
      7.  __________          ____     0__  ones_   n   
      8:  __________          ____     0__  ones_   n   
     9:  __________          ____     0__  ones_   n
     10:  __________          ____     0__  ones_   n
     11:  __________          ____     0__  ones_   n
     12:  __________          ____     0__  ones_   n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    794 ISDN-BRI Trunk Circuit Pack 
    17
    Interface
    Side
    Cntry/Peer Protocol
    Tells call processing software which ISDN protocol standard is applied.
    Field descriptions for page 2
    NOTE:
    If administering a TN2185 circuit pack, 8 ports appear; otherwise, 12 
    ports appear.
    Valid entries Usage
    network
    Tells call processing software whether a particular port is 
    connected to a user/network or a peer interface. These entries 
    are valid for the TN556B. You can enter 
    peer-master only if 
    the QSIG Basic Call Setup feature is enabledpeer-master
    Valid entries Usage
    a
      Determines how glare conditions are handled when Interface 
    field is peer-slave. This field is not administrable when the 
    Interface field is 
    network.b
    Valid entries Usage
    1 
    to 25When this field is 10, 12, or 13, the Protocol Version field is 
    equivalent to 
    b on the DS1 circuit pack screen.
    etsiWhen this field is etsi, the Protocol Version field is 
    equivalent to 
    b on the DS1 circuit pack screen.
    QSIGWhen the Interface field is peer-master, this field must be 
    QSIG.
    blank You cannot leave this field blank if the Interface field is set to 
    a valid, non-blank value. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    795 ISDN-BRI Trunk Circuit Pack 
    17
    Screen 126. BRI Trunk - Page 2 (using a TN2185 circuit pack)
    Screen 127. BRI Trunk - Page 2 (using a TN2198/TN556B circuit pack)
    NOTE:
    You cannot change the Endpt Init, SPID, or Endpt ID port parameters 
    unless that port is busied out or unadministered. It is possible to 
    change all other fields on this page even if the corresponding port is 
    active.
    NOTE:
    If the Interface field on page 1 contains a valid value when the screen 
    is submitted, the contents of the fields on page 2 for that port are 
    validated.  If the Interface field is blank when the screen is submitted, 
    the fields on this page for that port reset to their default values.
    change bri-trunk-board                                    Page 2 of 2
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
     Port  Interwork  XID  Endpt    SPID      Endpt    SPID      Endpt  Max
           Message   Test? Init?               ID                ID   NCA TSC
       1:  PROGress   y      n   ____________  __   ____________  __     0___
       2:  ALERTing   y      y   908957200000  __   ____________  __     0___
       3:  PROGress   y      y   0001________  __   ____________  __     0___
       4:  PROGress   n      n   ____________  __   ____________  __     0___
       5:  PROGress   n      y   625761449___  01   ____________  __     0___
       6:  PROGress   n      n   ____________  __   ____________  __     0___
       7.  PROGress   n      n   ____________  __   ____________  __     0___
       8:  PROGress   n      n   ____________  __   ____________  __     0___
       Port Directory   Directory         Port Directory   Directory
              Number      Number                 Number      Number
         1:                                 5:
         2:                                 6:
         3:                                 7:
         4:                                 8:
    change bri-trunk-board                                    Page 2 of 2
                             ISDN-BRI TRUNK CIRCUIT PACK
                                           
     Port Interwork XID Endpt    SPID      Endpt                     Max
           Message   Test? Init?               ID                     NCA TSC
       1:  PROGress   n      y   ____________  __                        0___
       2:  ALERTing   n      y   ____________  __                        0___
       3:  PROGress   n      y   ____________  __                        0___
       4:  PROGress   n      y   ____________  __                        0___
       5:  PROGress   n      y   ____________  __                        0___
       6:  PROGress   n      y   ____________  __                        0___
       7.  PROGress   n      y   ____________  __                        0___
       8:  PROGress   n      y   ____________  __                        0___
       9:  PROGress   n      y   ____________  __                        0___
      10:  PROGress   n      y   ____________  __                        0___
      11:  PROGress   n      y   ____________  __                        0___
      12:  PROGress   n      y   ____________  __                        0___ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    796 ISDN-BRI Trunk Circuit Pack 
    17
    Port
    This is a display-only field. It shows the port number to which parameters 
    administered on the row apply.
    Interworking Message
    This field determines what message the switch sends when an incoming ISDN 
    trunk call interworks (is routed over a non-ISDN trunk group).
    XID Test
    Endpt Init 
    Indicates whether the far end supports endpoint initialization. DEFINITY ECS 
    blocks you from changing this field unless the port is busied out or 
    unadministered. 
    Valid entries Usage
    PROGress
    Normally select this value. PROGress asks the public network 
    to cut through the B-channel and let the caller hear tones such 
    as ringback or busy tone provided over the non-ISDN trunk.
    ALERTingALERTing causes the public network in many countries to 
    play ringback tone to the caller. Select this value only if the 
    DS1 is connected to the public network, and it is determined 
    that callers hear silence (rather than ringback or busy tone) 
    when a call incoming over the DS1 interworks to a non-ISDN 
    trunk.
    Valid entries Usage
    y/n
    Indicates whether the far end supports the Layer 2 XID test.
    Valid entries Usage
     y  If set to y, the SPID field must not be blank. DEFINITY ECS 
    blocks you from changing this field and the SPID field unless 
    that port is busied out or unadministered.
    nIf set to n, the SPID and Endpt ID fields must be blank. 
    						