Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 787 ISDN Numbering — Public/ Unknown 17 ISDN Numbering — Public/ Unknown This screen supports the ISDN Call Identification Display feature. The feature provides a name/number display for display-equipped stations within an ISDN network. The system uses the caller’s name and number and displays it on the called party’s display. Likewise, the called party’s name and number can be displayed on the caller’s display. The screen allows you to specify the desired digits for the Calling Number IE and the Connected Number IE (in addition to the QSIG Party Number) for any extension in the Public and/or Unknown Number Plans. Administer these screens if either the Send Calling Number, Send Connected Number field is specified, or the Supplementary Service Protocol field is b on the trunk group screen. NOTE: If the table is not properly administered and the Send Calling Number or Send Connected Number field is y or r and the Numbering Format field on the ISDN Trunk Group screen is public or unknown, the Calling Number and Connected Number IE are not sent. If the table is not administered, but the Send Calling Number or Send Connected Number field is public or unknown, the Identification Number (PartyNumber data type) is not sent for QSIG PartyNumbers. In this case, the ASN.1 data type containing the PartyNumber (PresentedAddressScreened, PresentedAddressUnscreened, PresentedNumberScreened, or PresentedNumberUnscreened) will be sent marked as “PresentationRestricted” with “NULL” for the associated digits. Screen 123. ISDN Numbering Public/Unknown change isdn public-unknown-numbering Page 1 of 8 ISDN NUMBERING - PUBLIC/UNKNOWN FORMAT Ext Ext Trk CPN Total CPN Ext Ext Trk CPN Total CPN Len Code Grp(s) Prefix Len Len Code Grp(s) Prefix Len _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __ _ _____ _______ _______________ __
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 788 ISDN Numbering — Public/ Unknown 17 Ext Len Specifies the number of digits the extension can have. Ext Code Allows for groups of extensions to be administered. NOTE: When 0 alone is entered, the Ext Len field must be 1 and the DDD number must be 10-digits. Trk Grp(s) The switch generates the station’s identification number if there is an entry in the Ext Code field, and this field is administered with the trunk group number carrying the call. Valid entries Usage 0 to 5 Corresponds to the extension lengths allowed by the dial plan. Valid entries Usage 0 to 9The Ext Code can be up to 5-digits long depending on the Ext Len field entry. The entry cannot be greater than the Ext Len field entry. For example, in the case of a 4-digit Ext Len field entry, an Ext Code of 12 is the equivalent of all extensions of the screen 12xx, excluding any explicitly listed longer codes. If a code of 123 is also listed, the 12 code is equivalent of all extensions of the screen 12xx except extensions of the screen 123x. The coding precludes having to list all the applicable 12xx extensions. attdFor attendant Valid entries Usage 1 to 7 digits Enter the valid administered ISDN trunk-group number or a range of group numbers. For example, if trunk groups 10 through 24 use the same CPN Prefix, enter 10-24. blank The identification numbers are not dependent on which trunk group the call is carried.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 789 ISDN Numbering — Public/ Unknown 17 CPN Prefix Use this field to specify the number that is added to the beginning of the extension to form a Calling or Connected Number. Total CPN Len Valid entries Usage 1 to 15 digits Only digits are allowed in the CPN Prefix column. Leading spaces, or spaces in between the digits, are not allowed. nIf the length of the CPN Prefix matches the Total CPN Length, the extension number is not used to formulate the CPN number. nIf the number of digits in the CPN Prefix plus the extension length exceeds the administered Total CPN Length, excess leading digits of the extension are deleted when formulating the CPN number. nIf the number of CPN Prefix digits plus the extension length is less than the Total CPN Length, the entry is not allowed. nIf the Total CPN Length is 0, no calling party number information is provided to the called party and no connected party number information is provided to the calling party. blank If this field is blank, the extension is sent unchanged. This is useful in countries where the public network is able to insert the appropriate CPN Prefix to form an external DID number. Valid entries Usage 0 to 15Enter the total number of digits to send.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 790 ISDN-BRI Trunk Circuit Pack 17 ISDN-BRI Trunk Circuit Pack This screen administers an ISDN-BRI circuit pack. See DEFINITY ECS System Description for information on the maximum number of ISDN-BRI circuit packs that you can administer. Screen 124. BRI Trunk (using a TN2185 circuit pack) Location This is a display-only field. It shows the TN2185 circuit pack location (PPCSS) Name Interface Companding Valid entries Usage 1–15 alpha-numeric characters This name is used to identify the circuit pack. Valid entries Usage a-law Indicates the companding algorithm expected by the system at the far end. mu-law change bri-trunk-board Page 1 of 1 ISDN-BRI TRUNK CIRCUIT PACK Location: 01A09 Name: ______________ Interface Companding: a-law_ DCP/Analog Bearer Capability: 3.1kHz T3 Timer Length (sec): 15_ Port Interface Side Cntry/Peer TEI Time Invert Synch Layer 1 Detect Protocol Fill Bits? Source? Stable? Slips? 1: user_______ 12__ 0__ flags n n n n 2: network____ etsi 0__ ones_ y y y y 3: user_______ 2___ auto flags y n y n 4: peer-slave_ b QSIG 0__ flags n y y n 5: peer-master a QSIG auto ones_ n n n n 6: ___________ ____ 0__ ones_ n n y n 7. ___________ ____ 0__ ones_ n n y n 8: ___________ ____ 0__ ones_ n n y n
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 791 ISDN-BRI Trunk Circuit Pack 17 DCP/Analog Bearer Capability T3 Timer Length (sec) Port This is a display-only field. It shows the port number to which parameters administered on the row apply. Interface Side Valid entries Usage 3.1kHz Indicates how to encode the Bearer Capability IE for an outgoing call originated by a DCP or analog endpoint. speech Valid entries Usage 1 to 127 Tells the TE side how long to wait, in seconds, for an inactive Layer 1 to become active. Valid entries Usage network Tells call processing software whether a particular port is connected to a user/network or a peer interface. These entries are valid for the TN2185. You can enter peer-slave only if the QSIG Basic Call Setup feature is enableduser peer-master peer-slave Valid entries Usage a Determines how glare conditions are handled when Interface field is peer-slave.b
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 792 ISDN-BRI Trunk Circuit Pack 17 Cntry/Peer Protocol Tells call processing software which ISDN protocol standard is applied. TEI Time Fill The bit pattern sent on the D-channel between valid LAPD packets. Invert Bits Synch Source Valid entries Usage 1 to 25When this field is 10, 12, 13, or etsi, the Protocol Version field is equivalent to b on the DS1 circuit pack screen. When the Cntry/Peer Protocol field is set 10, 12, 13, or etsi, set the Provol Version field to b. For all other administered values, the Protocol Version sets to a. etsi QSIG When the Interface field is peer-slave or peer-master, this field must be QSIG. The choice QSIG is valid only when the Interface field is peer-slave. blank You cannot leave this field blank if the Interface field is set to a valid, non-blank value Valid entries Usage auto 0 Valid entries Usage flags ones Valid entries Usage y/n Valid entries Usage y n
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 793 ISDN-BRI Trunk Circuit Pack 17 Layer 1 Stable Detect Slips Field descriptions for page 1 Screen 125. BRI Trunk (with a TN556B or TN2198 circuit pack) The following field descriptions are unique to the ISDN-BRI Circuit Pack screen with a TN556B or TN2198 circuit pack. The following fields do not display with a TN556B or TN2198 circuit pack: nT3 Timer Length (sec) nSynch Source nLayer 1 Stable nDetect Slips Valid entries Usage y Tells call processing and maintenance software whether to expect the network to drop Layer 1 when the BRI port is idle. Only the TN2185 may be set to n.n Valid entries Usage y/n Tells maintenance software whether slips reported by the BRI port should be logged. change bri-trunk-board Page 1 of 1 ISDN-BRI TRUNK CIRCUIT PACK Location: 01A09 Name: ______________ Interface Companding: a-law_ DCP/Analog Bearer Capability: 3.1kHz Port Interface Side Cntry/Peer TEI Time Invert Protocol Fill Bits? 1: network__ 12__ 0__ flags n 2: network__ etsi 0__ ones_ y 3: network__ 2___ auto flags y 4: peer-master b QSIG 0__ flags n 5: peer-master a QSIG auto ones_ n 6: __________ ____ 0__ ones_ n 7. __________ ____ 0__ ones_ n 8: __________ ____ 0__ ones_ n 9: __________ ____ 0__ ones_ n 10: __________ ____ 0__ ones_ n 11: __________ ____ 0__ ones_ n 12: __________ ____ 0__ ones_ n
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 794 ISDN-BRI Trunk Circuit Pack 17 Interface Side Cntry/Peer Protocol Tells call processing software which ISDN protocol standard is applied. Field descriptions for page 2 NOTE: If administering a TN2185 circuit pack, 8 ports appear; otherwise, 12 ports appear. Valid entries Usage network Tells call processing software whether a particular port is connected to a user/network or a peer interface. These entries are valid for the TN556B. You can enter peer-master only if the QSIG Basic Call Setup feature is enabledpeer-master Valid entries Usage a Determines how glare conditions are handled when Interface field is peer-slave. This field is not administrable when the Interface field is network.b Valid entries Usage 1 to 25When this field is 10, 12, or 13, the Protocol Version field is equivalent to b on the DS1 circuit pack screen. etsiWhen this field is etsi, the Protocol Version field is equivalent to b on the DS1 circuit pack screen. QSIGWhen the Interface field is peer-master, this field must be QSIG. blank You cannot leave this field blank if the Interface field is set to a valid, non-blank value.
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 795 ISDN-BRI Trunk Circuit Pack 17 Screen 126. BRI Trunk - Page 2 (using a TN2185 circuit pack) Screen 127. BRI Trunk - Page 2 (using a TN2198/TN556B circuit pack) NOTE: You cannot change the Endpt Init, SPID, or Endpt ID port parameters unless that port is busied out or unadministered. It is possible to change all other fields on this page even if the corresponding port is active. NOTE: If the Interface field on page 1 contains a valid value when the screen is submitted, the contents of the fields on page 2 for that port are validated. If the Interface field is blank when the screen is submitted, the fields on this page for that port reset to their default values. change bri-trunk-board Page 2 of 2 ISDN-BRI TRUNK CIRCUIT PACK Port Interwork XID Endpt SPID Endpt SPID Endpt Max Message Test? Init? ID ID NCA TSC 1: PROGress y n ____________ __ ____________ __ 0___ 2: ALERTing y y 908957200000 __ ____________ __ 0___ 3: PROGress y y 0001________ __ ____________ __ 0___ 4: PROGress n n ____________ __ ____________ __ 0___ 5: PROGress n y 625761449___ 01 ____________ __ 0___ 6: PROGress n n ____________ __ ____________ __ 0___ 7. PROGress n n ____________ __ ____________ __ 0___ 8: PROGress n n ____________ __ ____________ __ 0___ Port Directory Directory Port Directory Directory Number Number Number Number 1: 5: 2: 6: 3: 7: 4: 8: change bri-trunk-board Page 2 of 2 ISDN-BRI TRUNK CIRCUIT PACK Port Interwork XID Endpt SPID Endpt Max Message Test? Init? ID NCA TSC 1: PROGress n y ____________ __ 0___ 2: ALERTing n y ____________ __ 0___ 3: PROGress n y ____________ __ 0___ 4: PROGress n y ____________ __ 0___ 5: PROGress n y ____________ __ 0___ 6: PROGress n y ____________ __ 0___ 7. PROGress n y ____________ __ 0___ 8: PROGress n y ____________ __ 0___ 9: PROGress n y ____________ __ 0___ 10: PROGress n y ____________ __ 0___ 11: PROGress n y ____________ __ 0___ 12: PROGress n y ____________ __ 0___
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 796 ISDN-BRI Trunk Circuit Pack 17 Port This is a display-only field. It shows the port number to which parameters administered on the row apply. Interworking Message This field determines what message the switch sends when an incoming ISDN trunk call interworks (is routed over a non-ISDN trunk group). XID Test Endpt Init Indicates whether the far end supports endpoint initialization. DEFINITY ECS blocks you from changing this field unless the port is busied out or unadministered. Valid entries Usage PROGress Normally select this value. PROGress asks the public network to cut through the B-channel and let the caller hear tones such as ringback or busy tone provided over the non-ISDN trunk. ALERTingALERTing causes the public network in many countries to play ringback tone to the caller. Select this value only if the DS1 is connected to the public network, and it is determined that callers hear silence (rather than ringback or busy tone) when a call incoming over the DS1 interworks to a non-ISDN trunk. Valid entries Usage y/n Indicates whether the far end supports the Layer 2 XID test. Valid entries Usage y If set to y, the SPID field must not be blank. DEFINITY ECS blocks you from changing this field and the SPID field unless that port is busied out or unadministered. nIf set to n, the SPID and Endpt ID fields must be blank.