Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1718
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    677 Feature-Related System Parameters 
    17
    Unknown Numbers Considered Internal for 
    AUDIX
    Appears when, on the System-Parameters Customer-Options screen, either the 
    ISDN-PRI or ISDN-BRI Trunks field is 
    y. This field controls the treatment of an 
    ISDN number whose numbering plan identification is “unknown” in a QSIG 
    centralized AUDIX arrangement. This field works in conjunction with the Calling 
    Party Number to Intuity AUDIX field on the Hunt Group screen. The Calling 
    Party Number to Intuity AUDIX field on the Hunt Group screen must be 
    y for this 
    field to have an effect.
    Maximum Length
    Appears only if the Unknown Numbers Considered Internal for AUDIX field is 
    y. 
    Indicates the maximum length of an unknown private number. Any unknown 
    number longer than the administered value is considered external. This field 
    cannot be blank when it appears.
    Valid entries Usage
    y
    The unknown number is considered “internal” and AUDIX tries 
    to find a calling party name match for the digit string. If a name 
    match is found, AUDIX provides the calling party’s name. If no 
    name is found, AUDIX provides the calling party’s phone 
    number.
    nThe unknown number is considered “external” and AUDIX 
    provides the calling party’s phone number.
    Valid entries Usage
    1
     - 20Enter a number for the maximum length of an unknown private 
    number. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    678 Feature-Related System Parameters 
    17
    US NI Calling Name for Outgoing Calls?
    Field descriptions for page 7
    Screen 91. Feature-Related System Parameters screenValid entries Usage
    y/n
     Enter y to send a name on outgoing calls over NI PRI trunks. 
    Important: Be sure you have validated that your service 
    provider’s central office is capable of accepting calling name 
    information from DEFINITY in this way. For example, if the 
    central office switch is a 5ESS, it must be a generic 5EXX or 
    later. Failure to validate the central office capability may cause 
    the central office to drop outgoing calls from your switch. In 
    this case, change the value in this field to 
    n.
    Enter n to prevent sending calling name information with 
    outgoing calls over NI PRI trunks. 
    n is this field overrides a y 
    in the Send Name field of the outgoing trunk group screen.
    change system-parameters features  Page 7 of 10
                        FEATURE-RELATED SYSTEM PARAMETERS
      Pull Transfer: n  Update Transferred Ring Pattern? n
      Outpulse Without Tone? y  Wait Answer Supervision Timer? n
      Misoperation Alerting? n Repetitive Call Waiting Tone? y
      Allow Conference via Flash? y Repetitive Call Waiting Interval (sec): _
    Vector Disconnect Timer (min): __  Network Feedback During Tone Detection? y
      Hear Zip Tone Following VOA ? y  System Updates Time On Station Displays? n
    Intercept Treatment On Failed Trunk Transfers? n
      Station Tone Forward Disconnect: silence
        Level Of Tone Detection: precise
    Charge Display Update Frequency (seconds): 30
    Date Format on 6400/8400 Terminals: mm/dd/yy
    On-hook Dialing on 6400/8400 Terminals? n
    RECALL TIMING
            Flashhook Interval? y Upper Bound (msec): 1000
                      Lower Bound (msec): 200
    Forward Disconnect Timer (msec): 600
    ITALIAN DCS PROTOCOL
      Italian Protocol Enabled? y
    Apply Intercept Locally? _   Enforce PNT-to-PNT Restrictions? _ 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    679 Feature-Related System Parameters 
    17
    Pull Transfer
    Update Transferred Ring Pattern
    Outpulse Without Tone
    Wait Answer Supervision Timer
    Refer to Unanswered DID Call Timer (seconds)
     for more information. 
    Valid entries Usage
    y/n
    Enter y to enable the Pull Transfer feature on a system-wide 
    basis. This allows either the transferring or transferred-to 
    party to press the Transfer button to complete the transfer 
    operation
    Valid entries Usage
    y/n
     Enter y to change the ringing pattern from internal to external 
    when an internal station transfers an external call. If most of 
    your calls go through an attendant, you might want to set this to 
    y, so your users will be able to distinguish an external call. 
    Valid entries Usage
    y
     Enter y to indicate the switch will outpulse digits even when a 
    dial tone has not been received.
    nEnter “n” if the calling party should receive intercept tone if 
    no dial tone is detected.
    Valid entries Usage
    y
    Enter y to enable this feature on a systemwide basis. When y is 
    entered in this field, calls to stations unanswered after 50 
    seconds are dropped.
    n When n is entered in this field, unanswered calls drop only 
    when the calling party goes on-hook. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    680 Feature-Related System Parameters 
    17
    Misoperation Alerting
    Misoperation Alerting should not be enabled if Call Prompting is optioned.
    Repetitive Call Waiting Tone
    Allow Conference via Flash
    Repetitive Call Waiting Interval (sec)
    Vector Disconnect Timer (min)
    Enter the number of minutes, or blank that a trunk should remain connected to a 
    vector.
    Valid entries Usage
    y
    Enter y for misoperation recall alerting on multi-appearance 
    stations, analog stations, and attendant consoles.
    n Enter n for standard misoperation handling without recall 
    alerting.
    Valid entries Usage
    y/n
    Enter y to indicate that a repetitive call waiting tone be provided 
    to the called party for all types of call waiting access.
    Valid entries Usage
    y
     Enter y to allow an analog station to use flash to conference 
    calls together.
    nEnter n to prevent this.
    Valid entries Usage
    1
     to 99 in 
    increments of 1Enter a number to specify the number of seconds between call 
    waiting tones. This field appears when the Repetitive Call 
    Waiting Tone is 
    y.
    Valid entries Usage
    1
     to 240The number of minutes that you enter determines when the 
    trunk will be disconnected if the Disconnect Supervision-In or 
    Disconnect Supervision-Out fields on the Trunk screen are 
    n. 
    blank Enter blank if you do not want DEFINITY ECS to initiate a 
    disconnect. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    681 Feature-Related System Parameters 
    17
    Network Feedback During Tone Detection
    Hear Zip Tone Following VOA?
    This tone alerts a telephone user that the announcement has completed and a caller 
    is now connected. CallMaster set and attendant console users hear double zip tone 
    following the announcement. All other telephone users hear single zip tone. 
    NOTE:
    This field does not effect auto-answer zip tone heard prior to the VOA.
    System Updates Time On Station Displays
    This does not apply to phones (such as BRI phones) where the user sets the time.
    Intercept Treatment on Failed Trunk Transfers
    Valid entries Usage
    y/n
     Enter y to provide audible feedback to the user while the 
    system attempts to detect dial tone.
    Valid entries Usage
    y
       Enter y to play zip tone following a VDN of Origin 
    Announcement (VOA).
    nEnter n if you do not want zip tone following a VOA.
    Valid entries Usage
    y/n
     Enter y to have the system automatically update the time on 
    display phones when background maintenance is run (for 
    example, when the set is plugged in).
    Valid entries Usage
    y
    Enter y to provide intercept treatment to calls failing trunk 
    transfers.
    n Enter n to drop these calls. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    682 Feature-Related System Parameters 
    17
    Station Tone Forward Disconnect
    Tone Forward Disconnect applies to any station other than one administered as a 
    data endpoint, an attendant console, a BRI phone, an auto answer, or as an 
    Outgoing Call Management (OCM) agent.
    Level of Tone Detection
    For the most part, this option is no longer required in today’s switching 
    environment. It may be useful if your users are having difficulty placing outgoing 
    calls due to inaccurate detection of network dial tone. 
    Charge Display Update Frequency (seconds)
    This applies only if you use Advice of Charge or Periodic Pulse Metering with 
    display functions. 
    Valid entries Usage
    busy
    intercept
    silence
    When a station is the last party remaining off-hook on a call, 
    that station receives the indicated tone or silence until that 
    station is placed on-hook, or until the tone has played for 45 
    seconds and is followed by silence. 
    Valid entries Usage
    broadband
    This is the least exact of the levels of tone detection. If the 
    switch detects any tone at all, it interprets this as dial tone. 
    mediumThe switch interprets any tone which has a continuous on 
    period of longer than 1 second as dial tone. Otherwise, the 
    switch accepts whatever the tone detector circuit pack reports.
    precise  The switch accepts whatever the tone detector circuit pack 
    reports.
    Valid entries Usage
    10
    –60The amount of time (in seconds) between charge-display 
    updates. Frequent display updates may have considerable 
    performance impact. If the duration of a call is less than the 
    Charge Display Update Frequency, the display will not 
    automatically show charge information. To see charge 
    information for a call, the user must have a disp-chrg button 
    and must press the button before the call drops. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    683 Feature-Related System Parameters 
    17
    Date Format on 6400/8400 Terminals
    The format of the date as displayed on the telephones.
    On-hook Dialing on 6400/8400 Terminals
    For 6400/8400 telephone users with speakerphones.
    The next four fields control station-to-switch recall signal timing. If a flashhook 
    interval (recall window) is required, the upper and lower bounds of the interval 
    can be administered. An on-hook that lasts for a period of time greater than or 
    equal to the lower bound and less than or equal to the upper bound will be treated 
    as a recall flash. If an interval is not required, the Disconnect Timing value must 
    be administered. An on-hook that lasts for a period of time less than this value will 
    be ignored; greater than or equal to this value will be regarded as a disconnect. 
    Regardless, an on-hook lasting 50 to 150 ms coming from a 2500-type set will 
    always be treated as a digit pulse unless Ignore Rotary Digits is 
    y for that station.
    Flashhook Interval
    Valid entries Usage
    mm/dd/yy 
    month/day/year
    dd/mm/yyday/month/year
    yy/mm/ddyear/month/day
    Valid entries Usage
    y/n
     Enter y allows users to dial without lifting the handset. If you 
    enable this, users hear dial tone when they press the Speaker 
    button, even if the handset is on-hook.
    Valid entries Usage
    y 
    Enter y to indicate that a flashhook interval (recall window) is 
    required. If a 
    y is entered, Upper Bound and Lower Bound 
    appear
    nIf n is entered, Disconnect Timing appears. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    684 Feature-Related System Parameters 
    17
    Upper Bound (msec)
    Specifies the upper bound of the flashhook interval. Specifies the upper bound of 
    the station-to-switch recall signal timing interval in milliseconds. Appears when 
    Flashhook Interval is 
    y. 
    Lower Bound (msec)
    The lower bound of the station-to-switch recall signal timing interval in 
    milliseconds. Specifies the lower bound of the flashhook interval. Appears when 
    Flashhook Interval is 
    y.
    Forward Disconnect Timer (msec)
    Specify the duration of a momentary disconnect sent by the switch to an analog 
    station user when that user is the last party still off-hook on a call.
    The next three fields control the Italian DCS Protocol feature.
    Italian Protocol Enabled
    Apply Intercept Locally
    This field appears only if Italian Protocol Enabled is 
    y.
    Valid entries Usage
    80
     to 1250 (in 
    increments of 10). A flash of 50 msec to 130 msec is always acceptable from 
    a 2500-type set regardless of the setting of the Upper and 
    Lower bounds and will be treated as the digit one.
    Valid entries Usage
    80
     to 1250 (in 
    increments of 10). 
    Valid entries Usage
    25
     to 1500 (in increments of 25). 
    Valid entries Usage
    y/n
     Enter y to enable the Italian DCS feature on a systemwide 
    basis.
    Valid entries Usage
    y/n
     Enter y to indicate that DID/CO intercept treatment will be 
    applied locally instead of on the originating switch. 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    685 Feature-Related System Parameters 
    17
    Enforce PNT-to-PNT Restrictions
    This field appears only if Italian Protocol Enabled is 
    y.
    Field descriptions for page 8
    Screen 92. Feature-Related System Parameters screen
    Call Center System Parameters:
    Expert Agent Selection (EAS) Enabled
    To enable this field, either no ACD or vectoring hunt groups may exist or, existing 
    ACD or vectoring hunt groups must be skilled. Only appears if Expert Agent 
    Selection (EAS) on the System-Parameters Customer-Options screen is 
    y. 
    Valid entries Usage
    y/n
     Enter y to indicate that restrictions and denial of PNT-to-PNT 
    connections will be enforced when the EDCS message is 
    unavailable. A 
    y in this field means restrictions will be 
    enforced. 
    Valid entries Usage
    y/n
    Enter y to enable Expert Agent Selection.
    change system-parameters features  Page 8 of 10
    FEATURE-RELATED SYSTEM PARAMETERS
    CALL CENTER SYSTEM PARAMETERS
    EAS
    Expert Agent Selection (EAS) Enabled? n
    Minimum Agent-LoginID Password Length: 
    Direct Agent Announcement Extension: _____ Delay: ___
    Message Waiting Lamp Indicates Status For: station
    VECTORING
    Converse First Data Delay: 0 Second Data Delay: 2
    Converse Signaling Tone (msec): 100 Pause (msec): 70_
    Prompting Timeout (secs): 10
    Interflow-qpos EWT Threshold: 2
    SERVICE OBSERVING
    Service Observing: Warning Tone? n or Conference Tone?
    ASAI
    Call Classification After Answer Supervision? n Send UCID to ASAI? n 
    						
    							DEFINITY ECS Release 8.2
    Administrator’s Guide  555-233-506  Issue 1.1
    June 2000
    Screen reference 
    686 Feature-Related System Parameters 
    17
    Minimum Agent-LoginID Password Length
    Enter the minimum number of digits that must be administered as an EAS Agent’s 
    LoginID password. Only appears if Expert Agent Selection (EAS) on the 
    System-Parameters Customer-Options screen is 
    y.
    Direct Agent Announcement Extension
    Direct Agent Announcement Delay
    Only appears if Expert Agent Selection (EAS) or ASAI on the System-Parameters 
    Customer-Options screen is 
    y.
    Message Waiting Lamp Indicates Status For
    Only appears if Expert Agent Selection (EAS) on the System-Parameters 
    Customer-Options screen is 
    y. 
    Valid entries Usage
    0
    –9Entering a 0 or blank indicates no password is required.
    Valid entries Usage
    Valid extension  Enter the extension of the direct agent announcement. 
    Valid entries Usage
    0
    –99 Enter the number of seconds the caller will hear ringback 
    before the Direct Agent Announcement is heard by the calling 
    party.
    Valid entries Usage
    station 
      Since you only have one message waiting lamp on a phone, 
    you need to indicate if the message is for at the phone 
    extension or the loginID.
    loginIDExpert Agent Selection (EAS) must be enabled to use this 
    option. 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Instructions Manual