    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Tl Trunk Type Emulation
    Software Version:CPC-6 Version 4.0 or higherAddress: 
    FFl 8# 4# 6# (Trunk)## 1# (OS)#
    DescriptionDetermines the type of trunk signaling that each Tl channel emulates (E&M
    by default).
    Programming
    I
    Notes
    FFl 8# 4## 6# (1164)# l# (013)#
    f+
    Trunk Number (l-64)O=Loop start
    1 =ireserved for-future use)
    2=Ground Start (used for
    ground start emulation)
    3=E&M
    Power-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    Ground Start Requirement.If your system uses Tl COP (Central Office
    Protocol) Version 1.1 or 1.2, it must be 
    ,upgraded to Version 1.4 or higher if
    you wish to use the “Ground Start” setting.Page l-l 88
    DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl )
    DID/DNS
    Software Version:CPC-B Version 4.0 or higherAddress: 
    IFFi W 4# W (Trunk)# 2# (O-2)#
    DeskiptionUse this address to enable trunks for DID or DNIS calls.l
    If DID is seiected, the system will use the DID Numbers Table (see FFl
    8# 3#) to detemine which extension(s) will receive the DID call.l
    If DNTS is selected (available only with Tl interface), the system will
    use the DNIS Numbers Table (see FFl 8# 4# 7#) to determine which
    extension(s) will receive the DNIS call.
    The DID Numbers Table can 
    be used for DID or DNIS. Therefore, ifall 500
    entries in the DNIS Numbers 
    Table are filled, a Tl channel can be set to DID,
    and DNIS service can still be used.
    Programming
    i
    FFI 6# 4# 6# (1-64)# 2# (0-2)#
    f4
    Trunk Number (l-64)O=Neith& DID nor DNIS
    is used.
    l=DID is used.
    25DNIS is used.
    Related ProgrammingInbound DID 
    DialNumbers: FFl 8# 3# (DIDNo.)# (ExtNo.)#
    DNIS Number Setting: FFl 8# # 7# (DNISNo.)# (ExtNo.)#
    DIDIDNIS Flexible Ringing Assignments: FFl 8# (5# or 6#) @lD/DNIS
    No.)# (ExtNo.)# (OOOO[OO]-l l l l [ 1 l])#
    NotesDigit Length Requiremen&The DBS only supports 4digit DIDAlMS
    numbers.
    CO RequirementWhen the CO sends a DIDIDNIS call to the DBS, it first
    receives a “wink” 
    signal &om the DBS before sending the digits.Once the
    wink is received, the CO should wait at least 200 ms before sending the
    digits.
    Power-C’chg Requirement.For changes to this parameter to take effect,
    the system must be tumed off, then back 
    OIL
    DBS-70-400
    ;..
    DBS Manual - Issued 8/l/95Page l-1 87 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Soha= k~;xi~n:CPC-B Version 4.0 or higherAddress: 
    #-I T r;a# 4# 6# (Truwk)# 3# (012)#
    DescriptionDetermines the signaling class used by Tl channels on outgoing calls
    (Immediate Start by de&&).’
    Programming
    FFI 8# 4# 6# (144)# 3# (0-2)#
    f
    Trunk Number (l-64)O=Immediate Start.
    l=Wink start.
    2=Dial Tone Start.
    CO Requirement.The Outgoing Type setting must match what is ordered
    f?om the CO..
    Power-Cycling Requirement.For changes to this parameter to take effect,
    the system must be 
    turned off, then back on.
    Page 1-188DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-Programming
    Chapter 1. System Programming (FFl)
    Incoming Signaling Type
    Software Version:CPC-8 Version 4.0 or higherAddress: 
    FFI 8# 4# 6## (Trunk)# 4#I (0 or I)#
    DescriptionDetermines the signaling class used by Tl channels on incoming calls
    (Immediate Start/Ringdown by default).
    Programming
    r
    Notes
    FFI 8# 4# 6# (I-64)# 4# (0 or l)#
    f+
    Trunk Number (l-64)O=Immediate Start/
    Ringdown.
    l=Wink Start.
    CO Requirement.The Incoming Type setting must match what is ordered
    from the CO.
    Power-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-189 
    						
    							Chapter 1. System Programming (FF’l)Section 400-Programming
    Trunk Mode
    Software Version:CPC-6 Version 4.0 or higherAddress: 
    FFI 8# 4#I 6# (Trunk)# 5# (0 or l)#
    DescriptionDetermines whether Tl channels are used for only outgoing calls, or for both
    incoming and outgoing calls.
    Programming
    I
    FFI 8# 4# 6# (l-64)# 5# (0 or l)#
    f+
    Trunk Number (l-64)O=Incoming and Outgoing.
    l=Outgoing only.
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    Page l-190DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Robbed Bit Setting
    Software Version:CPC-B Version 4.0 or higherAddress: 
    FFl 8# 4## 6# (Trunk)# 6# (0 or l)#
    DescriptionThe Robbed Bit Setting determines if AB or ABCD signaling is used.
    AB/ABCD signaling robs bits from the 
    Tl channels, and uses those bits to
    transmit signaling information. SF 
    (SuperFrame) normally uses AB
    signaling; ESF (Extended 
    SuperFrame) normally uses ABCD signaling.
    Programming
    I
    FFl 8# 4# 6# (l-64)# 6# (0 or l)#
    i(lr
    Trunk Number ( l-64)-
    O=Robbed Bit Off
    (AB/ABCD signaling not used)
    l=Robbed Bit On
    (AB/ABCD signaling is used)
    NotesYower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-191 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Incoming Dialing Method
    Software Version:CPC-B Version 4.0 or higher
    Address:FFl 8# 4# 6# (Trunk)# 7# (0 or l)#
    DescriptionDetermines whether the system expects dial-pulse or DTMF digits for
    incoming DID or DNIS calls over the 
    Tl.
    Programming
    I
    FFl 8# 4# 6# (1164)# 7# (0 or l)#
    ff
    Trunk Number (l-64)O=Dial-Pulse (10 PPS)
    l=DTMF
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off..then back on.
    Hardware Requirement.An MFR card is required for DID/DNIS if DTMF
    signaling is used.Page l-l 92
    DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Dial Tone Transmission
    Software Version:
    CPC-B Version 4.0 or higher.Address: 
    FFl 6# 4# 6# (Trunk)#I W (0 or l)#
    DescriptionThis address is reserved for future use.
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-193 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Busy Tone Transmission
    Software Version:
    CPC-B Version 4.0 or higherAddress: 
    FFl 8# 4# 6# (Trunk)# 9# (0 or l)#
    DescriptionThis address is reserved for future use.
    Page 1-194DBS Manual - Issued 8/l/95.DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFi)
    Dial Tone Receive
    Software Version:CPC-B Version 4.0 or higherAddress: 
    FFl 8# 4# 6# (Trunk)# lO# (0 or l)#
    DescriptionDetermines whether dial tone is transmitted from the DBS Tl channel to DBS
    stations.
    Set this address to “On” only if the far end does not provide Tl dial tone.
    Programming
    I
    I
    FFl 8# 4# 6# (l-64)# 1 O# (0 or l)#
    f+
    Trunk Number (1-64)O=Off
    l=On
    NotesOr&ring Tones From Carrier.If a carrier is supplying Tl services, always
    order Dial Tone and 
    Ringback Tones from the carrier.
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-195 
    						