Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Section 300~InstallationChapter 5. Peripheral Equipment Table S-11. Maximum distrurces for SLTA installation WiringMax. distance (in feet) betweenMax. distance (in feet) between fF”!.Fthe DBS and SLTAthe SLTA and the SLT AWG22300’or10n3000’or100SI AWG24190’or10Sz1900’or100rZ AWG 26120’ or 10 Q1200’ or 100 n 4. 5. 6. 7. 8. 9. If the DBS is powered up, turn off the power. Connect the GND and +24V leads on the SLTA to the DBS connector panel. Be sure the wires do not touch each other or touch the metal frame housing. Turn on the DBS power. Connect the “T” and “R” leads to the digital extension ports on the DBS as per Figure 5-21. One digital extension port is required for each SLT. Connect the SLT “T” and “R” leads to the SLTs. Install the cover on the SLTA.DBS-70-300DBS Manual - Issued 8/l/955-35
Chapter 5. Peripheral EquipmentSection 3004nstalIation Figure S-21. SLTA installation To +24Von DES CN2 Connector \!c-- To GND on2DBSCN2 -Connector QfSLTA(W-43709) ,To SLT A and B .To SLT C and D CN3II T PSLT‘A’ ’ SLT ’‘B CN4 %ISLT ’ 5-36DES Manual - Issued 8/l/95DBS-70-300
Chapter 6. Double-Cabinet Systems Two DBS cabinets can be connected in order to increase capacity. This chapter includes connection procedures, as well as capacities for two-cabinet systems. See Chapter 4 for instructions on installing Tls in two-cabinet systems. This chapter covers the following topics: TopicPage Guidelines6-3 Installation6-10 DBS-70-300DBS Manual - issued 8/l/956-1
Section 300~InstallationChapter 6. Double-Cabinet Systems Guidelines lTwo DBS cabinets can be connected to increase line size. The maximum line size consists of two DBS 96 cabinets, which provide 192 ports. lCPC-B and SCC-B are required for two-cabinet systems. lIf ground start or DID trunks are used in both cabinets, separate -48V supplies must be supplied for each cabinet. If AECs are used in both cabinets, separate SLT ringer boxes must be supplied for each cabinet. lThe following table shows the acceptable combinations of system types Table 6-I.Trunk and extension port maximums for double-cabinet systems System Corn binations Master Slave DBS40DBS 40 DBS72DBS40Trunk Extension PortsPorts 1648 2472 Expansion Ports (Trunk lines or extensions) 8(SeeNote1.) 0(SeeNote2.)I DBS721DBS7213219618(SeeNote1.) DBS96DBS40328816 DBS96DBS724011216 1 DBS96 1 DBS96 I481 128I 16 Notes: 1. The slave cabinet must be used for expansion ports. 2. When a DBS72 and DBS40 are connected, expansion ports cannot be used. lFigures 6-l through 6-6 shows slot usage for two-cabinet combinations.DBS-70-300DBS Manual - Issued 601956-3
Chapter 6. Double-Cabinet SystemsSection 300~Installation F imre6-I. Slotusagefortwo-cabinetsvstems.DRS 40 + DRS 40 DBS 40 (Slave) TRKl EC1 EC2 EC3 EC/TRKSCC CPC AUXl AUX2 8EC2 EC3 EC/IRKsee CPC Notes: *See “Tl Interface” on page 4-11 for EC/TRK port numbers for Tl. #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave AUXl. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUXl. (When two MFR cards are used, Strap S3 on the second card must be cut..) 6-4DES Manual - Issued #l/95DES-70-300
Section 300~installationChapter 6. Double-Cabinet Systems Figure 6-2. Slot usage for two-cabinet systems, DBS 72 + DBS 40 DBS40(Slave)EC3 EC/l-RKSCC CPC AUXl AUX2 ? s 42 2 7 255;;:0 T’RKl lEC1 IEC2 DBS 72 (Master) -IRK1IRK2EC1EC2EC3EC4EC5:C/TRK Notes: *A maximum of two MFR cards can be installed in a two-cabinet system.With Cable Kit Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave AUXl. Wrth Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUXl. (When two MFR cards are used, Strap S3 on the second card must be cut)DBS-70-300DBS Manual - Issued 6/l/956-5
Chapter 6. Double-Cabinet Systems Section 3004nstallation F iaure6-3. Slotusdwefortwo-cabinetsvstems.DBS 72 + DBS 72 DBS 72 (Slave) TRK TRK EC1 EC2 EC3 EC4 EC5 EC6 EC/ SCC CPC AUX AUX 12TRK12 s 74% 4 2 G g DBS 72 (Master) TRK TRK EC1 EC2 EC3 EC4 EC5 EC6 EC/ SCC CPC AUX AUX1 2 TRK1 2 % Notes: *See “Tl Interface” on page 4-11 for EC/TRK port numbers for Tl. Beginning with CPC-B Version 4, the EC/TRK slot in the slave DBS 72 can be used for trunks or lines. Prior to CPC-B Version 4, this slot could only be used for lines. #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave AUXl . With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUXl. (When two MFR cards are used, Strap S3 on the second card must be cut.) 6-6DES Manual - Issued 8/l/95DES-70-300
Section 300~InstallationChapter 6. Double-Cabinet Systems igure 6-4. SZot usage for two-cabinet systems, DBS 96 + DBS 40 DBS 40 (Slave) KC CPC -T- EC1EC2AUX 1 AUX 2 DBS 96 (Master) EC1EC2EC3EC4EC7 1 ECISCCICPCIAUX IAUX Notes: *See “Tl Interface” on page 4-l 1 for ECflRK port numbers for Tl. #A maximum of twoMFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUXl t and one MFR is installed in the Slave AUXl. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUXl. (When two MFR cards are used, Strap S3 on the second card must be cut.)DES-70-300 DES Manual - issued 6/T/956-7
Chapter 6. Double-Cabinet Systems Section 3004nstallation Figure 6-5. Slot usage for two-cabinet systems, DBS 96 + DBS 72DBS 72 (Slave) DBS 96 (Master) IRK TRK -TRK EC1 EC2 EC3 EC4 EC5 EC6 EC7 EC8 EC/SCC CPC AUX AUX 1 2 3TRK1 2 9 \o3 )r: 7.r:o\ ii +g Notes: *See “Tl Interface” on page 4-l 1 for EC/TRK port numbers for Tl. “A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUXl, and one MFR is installed in the Slave AUXl. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one in the CPC slot and one in AUXl. (When two MFR cards are used, Strap S3 on the second card must be cut.)6-8 DES Manual - Issued 8/l/95DES-70-300