    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Section 300~InstallationChapter 5. Peripheral Equipment
    Table S-11. Maximum distrurces for SLTA installation
    WiringMax. distance (in feet) betweenMax. distance (in feet) between
    fF”!.Fthe DBS and SLTAthe SLTA and the SLT
    AWG22300’or10n3000’or100SI
    AWG24190’or10Sz1900’or100rZ
    AWG 26120’ or 10 Q1200’ or 100 n
    4.
    5.
    6.
    7.
    8.
    9.
    If the DBS is powered up, turn off the power.
    Connect the GND and 
    +24V leads on the SLTA to the DBS connector
    panel. 
    Be sure the wires do not touch each other or touch the metal
    frame housing.
    Turn on the DBS power.
    Connect the “T” and “R” leads to the digital extension ports on the DBS
    as per Figure 5-21. One digital extension port is required for each SLT.
    Connect the SLT “T” and “R” leads to the SLTs.
    Install the cover on the SLTA.DBS-70-300DBS Manual 
    - Issued 8/l/955-35 
    						
    							Chapter 5. Peripheral EquipmentSection 3004nstalIation
    Figure S-21. SLTA installation
    To +24Von DES CN2
    Connector \!c--
    To GND on2DBSCN2 -Connector
    QfSLTA(W-43709)
    ,To SLT A and B
    .To SLT C and D
    CN3II
    T PSLT‘A’
    ’ SLT ’‘B
    CN4
    %ISLT ’
    5-36DES Manual - Issued 8/l/95DBS-70-300 
    						
    							Chapter 6. Double-Cabinet Systems
    Two DBS cabinets can be connected in order to increase capacity. This
    chapter includes connection procedures, as well as capacities for two-cabinet
    systems.
    See Chapter 4 for instructions on installing Tls in two-cabinet systems.
    This chapter covers the following topics:
    TopicPage
    Guidelines6-3
    Installation6-10
    DBS-70-300DBS Manual - issued 8/l/956-1 
    						
    							6-2DBS Manual - Issued 8/l/95DBS-70-300 
    						
    							Section 300~InstallationChapter 6. Double-Cabinet Systems
    Guidelines
    lTwo DBS cabinets can be connected to increase line size. The maximum
    line size consists of 
    two DBS 96 cabinets, which provide 192 ports.
    lCPC-B and SCC-B are required for two-cabinet systems.
    lIf ground start or DID trunks are used in both cabinets, separate -48V
    supplies must be supplied for each cabinet. 
    If AECs are used in both
    cabinets, separate SLT ringer boxes must be supplied for each cabinet.
    lThe following table shows the acceptable combinations of system types
    Table 6-I.Trunk and extension port maximums for double-cabinet systems
    System
    Corn binations
    Master
    Slave
    DBS40DBS 40
    DBS72DBS40Trunk Extension
    PortsPorts
    1648
    2472
    Expansion Ports
    (Trunk lines or
    extensions)
    8(SeeNote1.)
    0(SeeNote2.)I
    DBS721DBS7213219618(SeeNote1.)
    DBS96DBS40328816
    DBS96DBS724011216
    1 DBS96 1 DBS96 I481 128I 16
    Notes:
    1. The slave cabinet must be used for expansion ports.
    2. When a DBS72 and DBS40 are connected, expansion ports cannot be
    used.
    lFigures 6-l through 6-6 shows slot usage for two-cabinet combinations.DBS-70-300DBS Manual 
    - Issued 601956-3 
    						
    							Chapter 6. Double-Cabinet SystemsSection 300~Installation
    F imre6-I. Slotusagefortwo-cabinetsvstems.DRS 40 + DRS 40
    DBS 40 (Slave)
    TRKl EC1 EC2 EC3 EC/TRKSCC CPC AUXl AUX2
    8EC2 EC3 
    EC/IRKsee CPC
    Notes:
    *See “Tl Interface” on page 4-11 for EC/TRK port numbers for Tl.
    #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit
    Version 1.1, one MFR is installed in the Master 
    AUXl, and one MFR is installed in the
    Slave 
    AUXl. With Cable Kit Version 1.2, both MFR cards are installed in the slave
    cabinet--one in the CPC slot and one in 
    AUXl. (When two MFR cards are used, Strap S3
    on the second card must be cut..)
    6-4DES Manual - Issued #l/95DES-70-300 
    						
    							Section 300~installationChapter 6. Double-Cabinet Systems
    Figure 6-2. Slot usage for two-cabinet systems, DBS 72 + DBS 40
    DBS40(Slave)EC3 
    EC/l-RKSCC CPC AUXl AUX2
    ?
    s
    42 2
    7
    255;;:0
    T’RKl lEC1 IEC2
    DBS 72 (Master)
    -IRK1IRK2EC1EC2EC3EC4EC5:C/TRK
    Notes:
    *A maximum of two MFR cards can be installed in a two-cabinet system.With Cable Kit
    Version 1.1, one MFR is installed in the Master 
    AUXl, and one MFR is installed in the
    Slave 
    AUXl. Wrth Cable Kit Version 1.2, both MFR cards are installed in the slave
    cabinet--one in the CPC slot and one in 
    AUXl. (When two MFR cards are used, Strap S3
    on the second card must be cut)DBS-70-300DBS Manual 
    - Issued 6/l/956-5 
    						
    							Chapter 6. Double-Cabinet Systems
    Section 3004nstallation
    F iaure6-3. Slotusdwefortwo-cabinetsvstems.DBS 72 + DBS 72
    DBS 72 (Slave)
    TRK TRK EC1 EC2 EC3 EC4 EC5 EC6 EC/
    SCC CPC AUX AUX
    12TRK12
    s
    74%
    4
    2
    G
    g
    DBS 72 (Master)
    TRK TRK EC1 EC2 EC3 EC4 EC5 EC6 EC/
    SCC CPC AUX AUX1 2
    TRK1 2
    %
    Notes:
    *See “Tl Interface” on page 4-11 for EC/TRK port numbers for Tl.
    Beginning with CPC-B Version 4, the EC/TRK slot in the slave DBS 72 can be used for
    trunks or lines. Prior to CPC-B Version 4, this slot could only be used for lines.
    #A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit
    Version 1.1, one MFR is installed in the Master 
    AUXl, and one MFR is installed in the Slave
    AUXl . With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one
    in the CPC slot and one in 
    AUXl. (When two MFR cards are used, Strap S3 on the second
    card must be cut.)
    6-6DES Manual - Issued 8/l/95DES-70-300 
    						
    							Section 300~InstallationChapter 6. Double-Cabinet Systems
    igure 6-4. SZot usage for two-cabinet systems, DBS 96 + DBS 40
    DBS 40 (Slave)
    KC CPC
    -T-
    EC1EC2AUX
    1
    AUX
    2
    DBS 96 (Master)
    EC1EC2EC3EC4EC7 1 ECISCCICPCIAUX IAUX
    Notes:
    *See 
    “Tl Interface” on page 4-l 1 for ECflRK port numbers for Tl.
    #A maximum of twoMFR cards can be installed in a two-cabinet system. With Cable Kit
    Version 1.1, one MFR is installed in the Master AUXl t and one MFR is installed in the Slave
    AUXl. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one
    in the CPC slot and one in 
    AUXl. (When two MFR cards are used, Strap S3 on the second
    card must be cut.)DES-70-300
    DES Manual - issued 6/T/956-7 
    						
    							Chapter 6. Double-Cabinet Systems
    Section 3004nstallation
    Figure 6-5. Slot usage for two-cabinet systems, DBS 96 + DBS 72DBS 72 (Slave)
    DBS 96 (Master)
    IRK TRK -TRK EC1 EC2 EC3 EC4 EC5 EC6 EC7 EC8 EC/SCC CPC AUX AUX
    1 2 3TRK1 2
    9
    \o3
    )r: 7.r:o\
    ii
    +g
    Notes:
    *See “Tl Interface” on page 4-l 1 for EC/TRK port numbers for Tl.
    “A maximum of two MFR cards can be installed in a two-cabinet system. With Cable Kit
    Version 1.1, one MFR is installed in the Master 
    AUXl, and one MFR is installed in the Slave
    AUXl. With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one
    in the CPC slot and one in 
    AUXl. (When two MFR cards are used, Strap S3 on the second
    card must be cut.)6-8
    DES Manual - Issued 8/l/95DES-70-300 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cpc+AII/B Digital Business System Release Notes Manual