    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Chapter 1. System Programming (FFi)Section 400-Programming
    Red Alarm Detection
    Software Version:CPC-6 Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 2# 1# (015)#
    Slave Cabinet:FFI 8# 4## 5# 2# 1# (015)#
    DescriptionThe default value for this parameter is determined by network specifications.
    It should 
    not be changed.
    If a red alarm occurs, the “CFA” LED on the 
    Tl card lights. Also, if the Red
    Alarm Relay 
    (FFl 8# 4# 4/5# 4# 2#) is enabled, the alarm relay on the Tl
    MDF card closes.
    Programming
    I
    FFl 8# 4# (4 or 5)# 2# l# (O-5)#
    $$
    4=Master Cabinet0=4
    5=Slave Cabinet1=6
    2=8
    3=10
    4=12
    5=14
    Related ProgrammingRed Alarm Counter: 
    FFl 8# 4# (4 or 5)# 3# 3# (0-9000)#Red Alarm Relay: 
    FFl 8# # (4 or 5)# 4# 2# (0 or l)#Red Alarm FF Key: 
    FF5 (ExPort)# (Key)# CONF (103# or 123#)#Page l-l 66
    DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Prcgramming tFF1)Yellow Alarm Detection
    Software Version:
    CPC-B Version 4.0 or higher
    Address:Master Cabinet: 
    FFl 8# 4# 4## 2# 2# (0-15)#
    Slave Cabinet:FFl 8## 4# 5# 2# 2# (0-15)#
    DescriptionDetermines how long a yellow alarm signal must be on before the system
    detects a yellow alarm. When a yellow alarm occurs, the 
    “YEL” LED on the
    Tl card lights. Also, if the Yellow Alarm Relay (FFl 8i: 4# 4/5n” 1# l#) isenabled, the alarm relay on the 
    TI MDF card closes.
    Programming1I
    FFl 8# 4## (4 or 5)# 2# 2# (045)#
    7$
    I
    4=Master CabinetYellow Alarm Detection timer setting
    5=Slave Cabinet
    Default: 1 (50 ms) fsee tabie below!Table I-49. Yellow Alarm Detection timer values
    I Setting 
    ! Value
    ( 150 ms
    41 200 msI
    1
    51250ms
    [ 3OOms
    I350 ms
    1 400 ms
    I450 ms
    10500 ms
    11550ms
    12600 ms
    13650 ms
    14,700 ms
    15750ms
    DBS-70-400
    DBS Manual- Issued 8/l/95Page1 -167 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Related ProgrammingYellow Alarm Send: 
    FFl 8# 4#/ (4 or 5)# l# 7# (0 or l)#
    Yellow Alarm Recovery:FFl 8# 4# (4 or 5)# 2# 3# (0-15)#Yellow Alarm Counter: 
    FFl 8# 4## (4 or 5)# 3# 6# (0-9000)#Yellow Alarm Relay: 
    FFl 8# 4# (4 or 5)# # l# (0 or l)#
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    Page 1-168
    DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFI)
    Yellow Alarm Recovery
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4## 4## 2# 3# (0115)#
    Slave Cabinet:FFl 8# 4#I 5# 2# 3# (0115)#
    Description
    ProgrammingDetermines how long the DBS tries to recover from a yellow alarm before it
    re-syncs the 
    Tl trunk.
    FFl 8# 4# (4 or 5)# 2# 3# (0115)#
    7f
    4=Master CabinetYellow Alarm Recovery timer setting
    5=Slave CabinetDefault: 1 (10 rns) (see table below)I
    Table l-50.Yellow Alarm Recovery timer values
    Setting
    0
    Value
    Orlis
    I 11 1omsI
    220 ms
    330 ms
    440 ms
    550 ms
    660 ms
    770 ms
    880 ms
    990 ms
    10110 ms
    11120 ms
    12130 ms
    13140 ms
    14150 ms
    15160 ms
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-169 
    						
    							Chapter 1. System Programming (FFi)Section 400-Programming
    Related ProgrammingYellow Alarm Send: 
    FFl 8# 4## (4 or 5)# l# 7# (0 or l)#Yellow Alarm Detection: 
    FF1 8# # (4 or 5)# 2# 2# (0-15)##Yellow Alarm Counter: 
    FFl 8# 4# (4 or 5)# 3# 6# (0-9000)#Yellow Alarm Relay: 
    FFl 8# 4# (4 or 5)# 4## l# (0 or l)#
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.Page l-l 70
    DBS Manual - Issued 8/i/95DBS-70-400 _ 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Other Alarms Detection
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4## 4# 2# 4# (0-15)#
    Slave Cabinet:FFl 8# 4# 5# 2# 4# (0015)#
    DescriptionDetermines how long an out-of-frame (OOF), loss of signal, sync loss, or AIS
    signal must be on before the system generates an alarm.
    If an OOF, Sync Loss, or 
    AIS alarm occurs, a corresponding LED on the Tl
    card lights. (Sync Loss alarms light the “SLIP” LED.)
    The alarm relay on the 
    Tl MDF card will also close if the corresponding relay
    parameter is enabled.
    Programming
    II
    FFI 8# 4# (4 or 5)# 2# 4# (0-15)#
    7t
    4=Master CabinetOther Alarms Detection timer setting
    5=Slave CabinetDefault: 1 (250 rns) (see table below)
    Table l-51. Other Alarms Detection timer values
    Setting
    0
    Value
    Oms
    I 250msI
    2I 500 ms1
    I
    1
    3I 750 ms1
    4
    1000 ms
    51250 ms
    I
    I
    6I 1500 ms
    I 1750msI
    81 2000 ms
    I 2500 msI
    10I 3000 ms
    I 3500 ms
    124000ms
    134500ms
    145000msI
    15I 5500 ms1
    DBS-70-400DBS Manual - Issued 8/l/95Page l-171 
    						
    							ChapterRelated Programming
    Other Alarms Recovery:FFl 8# 4## (4 or 5)# 2# 5# (0-15)#
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    Page 1-l 72DBS Manual - issued 8/l/95.DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Other Alarms Recovery
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4#I 4# 2# 5# (O-15)#
    Slave Cabinet:FFl 8## 4# 5# 2# 5# (O-15)#
    DescriptionDetermines how long the DBS tries to recover from an Out-Of-Frame (OOF),
    Loss of Signal, Sync Loss, or 
    AIS alarm before it re-syncs the Tl trunk.
    Programming
    I
    FFI 8# 4## (4 or 5)# 2# 5# (0115)#
    7
    4=Master CabinetOther Alarms Recovery timer setting
    5=Slave Cabinet
    Default: 1 (250 ms) (see table below)
    Table I-52. Other Alarms Recovery timer values
    SettingValue
    0Oms
    1250 ms
    2500 ms
    3750 ms
    41000 ms
    51500 ms
    62000 ms
    72500 ms
    83000 ms
    94000 ms
    105000 ms
    116000 ms
    127000 ms
    138000 ms
    149000 ms
    1510000 ms
    Related ProgrammingOther Alarms Detection: 
    FFl 8# 4## (4 or 5)# 2# 4## (0-15)#
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    DBS-70-400DBS Manual - issued 8/l/95Page l-173 
    						
    							bikiprer I. 3ysrerr1 rrogrammwg 
    r I)3ection 4uwrrogrammlngFrame Loss Counter
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4## 3# 1# (019000)#
    Slave Cabinet:FFl 8# 4# 5# 3# 1# (O-9000)#
    DescriptionDetermines how many frame losses occur before a Frame Loss Alarm FF key
    is lit. The FF key lights when the counter exceeds the specified number
    within a 24-hour period.
    For instructions on programming 
    Tl alarm keys, see the TI Reference
    Manual (Section 500).
    Programming
    FFl 8# 4#/ (4 or 5)# 3# l#(019000)#
    f
    4=Master Cabinet
    5=Slave Cabinet
    Number of Frame Losses that occur
    within a 24-hour period before a
    Frame Loss Alarm FF key is lit
    Default: 9000
    Related ProgrammingFrame Loss Relay: 
    FFl’ 8# 4# (4 or 5)# 4# 4# (0 or l)#Page l-l 74
    DBS Manual - issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Slip Counter
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 3# 2# (0-9000)#
    Slave Cabinet:
    FFl 8# 4#I 5# 3# 2# (0-9000)#
    DescriptionDetermines how many slips occur before a Slip Alarm FF key is lit. (“Slips”
    are losses of data bits due to framing errors.) The FF key lights when the
    counter exceeds the specified number within a 
    24-hour period.
    This parameter also determines the number of slips that can occur before the
    system switches to the next clock source, at which time 
    the slip error
    counter for the first clock source is reset, and all phone calls in progress
    are disconnected. 
    It takes 20 seconds for the Tl to reboot.
    For instructions on programming 
    Tl alarm keys, see the Tl Reference
    Manual (Section 500).
    Programming
    I
    FFl 8# 4# (4 or 5)# 3# 2# (O-9000)#
    f
    4=Mas ter Cabinet
    5=Slave Cabinet
    Number of Slips that must occur
    within a 24-hour period before a
    Slip Alarm FF key is lit
    Default: 9000
    Related Programming
    Sync Source 1:FFl 8# 4# l# 2# (l-3)#Sync Source 2: 
    FF1 8# # l# 3# (0-3)#Sync Source 3: 
    FFl 8# 4# l# 4# (0-3)#Slip FF Key: 
    FF5 (ExtPort)# (Key)# CONF (102# or 122#)#
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-175 
    						