    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Section 300~installationChapter 6. Double-Cabinet Systems
    ‘igure 6-6. Slot usage for two-cabinet systems, DBS 96 tu DBS 96DBS 96 (Slave)
    i 1
    ~
    EC2
    EC3EClEC5EC7EC8CPCAUX
    1
    -l’RK TRK
    2 3AUX
    2DBS 96 (Master)
    EC2 EC3
    -I-
    EC4 EC5 ECtTRK TRK TRK EC1
    1 2 3
    *See “Tl Interface” on page 4-l 1 for EGTRK port numbers for Tl.
    #A maximum of twoMFR cards can be installed in a two-cabinet system. With Cable Kit
    Version 1.1, one MFR is installed in the Master AUX 1, and one MFR is installed in the Slave
    AUXl . With Cable Kit Version 1.2, both MFR cards are installed in the slave cabinet--one
    in the CPC slot and one in 
    AUXl. ‘(When two MFR cards are used, Strap S3 on the second
    card must be cut.)DBS-70-300DBS Manual 
    - Issued #l/956-9 
    						
    							Chapter 6. Double-Cabinet Systems
    Section 300~installation
    Installation
    1.Install the trunk and extension cards according to the layouts shown in the
    Figures 5-l through 6-6.
    Note:The port numbers for each slot are fixed.
    2.If you are using two MFR cards, cut Strap S3 on the second card.
    Figure 6-7. Strap 3, MFR cardI
    3.Using the cables provided, connect the CBL-M card in the master cabinet
    to the CBL-S card installed in the slave cabinet.
    Note: The EM1 filter must be installed as close to the cabinet as possible,
    as shown in Figure 6-8 on page 6-l 1.
    6-10DBS Manual - Issued 8/l/95DBS-70400 
    						
    							Section 300~InstallationChapter 6. Double-Cabinet Systems
    Double-cabinet insWation
    4.Connect two 24V power supply cords from the CBL-S card to the 24V
    and GND terminals on CN2 of the Connector Panel of the slave cabinet.
    Figure 6-9. CBL-S to Connector Panel connection, si’uve cabinetDBS-70-300DBS Manual 
    - Issued 6/t/956-11 
    						
    							Chapter 6. Double-Cabinet SystemsSection 300~Installation
    5.Set SW1 on the CBL-M card according to the following table.
    Table 6-2. CBLM switch settings
    System Corn binationsISwitch Settings
    DBS96DBS72OFF ONOFF ONON OFF OFF OFF
    DBS96DBS96OFF ON OFF ON ON OFF OFF OFF
    6-12
    DBS Manual - issued 6/l/95DES-70-300 
    						
    							Chapter 7. Specifications
    This chapter contains frequently referenced DBS specifications.
    Note: All maximums may not be attainable simultaneously. Also, attainment
    of some maximums depends on levels of feature usage and optional hardware
    requirements.
    Though every effort has been made to ensure the accuracy of these
    specifications, Panasonic does 
    not warrant them in regard to merchantability
    or fitness for a particular purpose. Specifications are subject to change
    without notice.
    This chapter covers the following topics::
    .
    I----~TopicIPage 1
    Electrical Characteristics
    Environmental Requirements
    Resource Maximums
    Cabling Specifications
    Communication Parameters
    Signaling Characteristics7-3
    7-4
    7-5
    7-13
    7-14I
    1 7-15 -
    Tone Characteristics1 7-16
    DES-70-300DBS Manual - Issued 0/l/95 
    						
    							7-2DES Manual - Issued 8/l/95DBS-70-300 
    						
    							Section 300~InstallationChapter 7. Specifications
    Electrical CharacteristicsTable 7-l. Input power
    EquipmentAll DBS cabinetsPower Requirements120V AC 
    + 10 % 60 Hz
    DBS key phones
    13 watts maximum (powered from the DBS)
    T&e 7-2.Power consumption and heat generation
    System
    status
    Power Consumption (in Watts)
    Withno traffic170250320340420500490570640withmax. traffic
    216324444432540648660768888
    Heat Generation (Btu per hour)
    Withno traffic5808531092116014331706167219452184
    Withmax. traffic
    73711061515147418432212225326213031
    Table 7-3. Battery backup capacity
    SystemBattery PackDBS 40
    m-43130f
    Capacity (with maximum traffic)40 minutes
    ]tiBS 72 IVB-43130
    IDBS 96 IvB-4313040 minutes
    30 minutes
    DBS-70-300DBS Manual - Issued 8/T/957-3 
    						
    							Chapter 7. SpecificationsSection 300-Installation
    Environmental Requirements
    Table 7-4.Temperature and humidity requirements
    Environmental Conditions
    Requirements
    Temperature32 to 104’ F (0 to 40’ C)
    /Relative Humidity
    Table 7-5.Dimensions and weight, sing&-cabinet systems and phones
    PhysicalDBS40DBS72
    Characteristics
    _,,
    DBS96
    Cabinet
    Dimensions (H x W x D in inches)
    121 x15 x9.35121 x19.5x9.4121 x19.5x9.4
    1 VB-432254 l/8 x 7 318 x 9
    1 Other key phones3 314 x 7 318 x 9
    DSLT3 l/8 x 7 318 x 9 l/8
    DSSl723 1/2x7 1/2x9
    1 EM/243 3/13 x 3 l/8 x 8 3/8
    Cabinet
    VB-43225
    Other key phones
    DSLT1.6
    Weight (Ibs)
    5365
    68
    2.3
    ,2.2
    1 DSSl72
    1 EM/24
    Table 7-6.
    Dimensions for two-cabinet systems
    Cabinet InstallationDBS 40 + DBS 40All Other Combinations
    Cabinetsinstalledoneabovetheother52x15x9.3552x19.5x9.4
    (10 in. between)
    7-4DBS Manual - Issued 8/l/95DBS-70-300 
    						
    							Section 300~InstallationChapter 7. Specifications
    Resource Maximums
    Table 7-7.Trunk and line capacities
    System
    Resources
    Trunk ports
    Extension ports
    Expansion ports
    Trunk/Extension speech
    path switching816 24 16 24 32 32 40 48
    24 48 64 48 72 96
    88112
    128
    8 I8 18 1818*116116 116
    nonblocking
    Notes:
    *Beginning with CPC-B Version 4, the EC/TRK slot in the slave DBS 72 can be used for trunks
    or lines. Prior to CPC-B Version 4, this slot could only be used for lines. 
    CPC-AI1 also allows
    this.
    Table 7-8. Feature-related capacities
    ResourceMaximums
    Attendants
    No. of attendants with CPC-A
    No. of attendants with CPC-B and CPC-AII (Version 2.0 or
    later)
    No. of attendants that can be assigned DSS/72s
    No. of attendants that can be assigned Attendant Consoles
    CPC-A and CPC-AII
    CPC-B (Version 2.0 to 4.0 only)
    Cal I back requests
    2
    4
    2 
    (AT% 1 and 2 only)
    0
    4 (1 per attendant)
    No. of requests that can be received by a single station
    14
    Call coverage
    No. of groups16
    No. of stations in a group8
    Call forwarding
    No. of simultaneous call forwarding registrationsNo. of stations in the systemDBS-70-300DES Manual 
    - Issued 8/l/957-5 
    						
    							Chapter 7. Specifications
    Section 300~Installation
    SCC-A
    ResourceMaximums
    Conference circuits
    3 four-party circuits
    KC-B with CPC-B
    SCC-B with CPC-A and 
    CPC-AI1
    8 four-party circuits
    3 four-party circuits
    No. of incoming authorization codes
    No.of outgoing authrorization codes
    1
    2
    1 No.of digits in each authorization codeI4I
    I--~HuntingI
    [No. of groups8
    No. of stations in a group8
    Least cost l.Outing 11 Area Code table
    1 Office Code table
    4 Special Area Code tables
    4 Special Office Code tables
    No. of entries in each routing table
    1000
    No. of digit addition tables8
    No. of digits that can be added16
    No. of digit deletion tables8
    1 No. of digits that can be deletedI16I
    i No. of time priority tables
    I No. of LCR trunk groups
    Toll Restrictions
    No. of Toll Restriction types81
    I No. of 7-digit restrictions
    No. of area. 
    code restriction tables
    tNo. of entries in each area code restriction table
    1 No. of office code restriction tablesI4II
    No. of entries in each office code restriction tableI1000 (4000 total)
    1 No. of groups
    No. of stations in a groupNo. of stations in the system7-6
    DBS Manuai - Issued 8/l/95DES-70-300 
    						