Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

Section 300~InstallationChapter 7. Specifications Resource Paging (continued) No. of external paging zones No. of stations in external paging zone 00 No. of stations in external paging zones 0 l-04 Speed dialMaximums 5 No. of stations in the system No. of stations in corresponding paging group 0 l-04 No. of personal speed dial numbers No. of system speed dial numbers10 per extension 90 (00 - 89) or 2Oq (000-199) with CPC-AII and CPC-B Version 7.0 No. of digits per speed dial number (personal and system) Trunk Queuing 16 No. of trunk queuing registrations1 per station Table 7-9.Hardware maximums for single-cabinet systems Part No.Des.criptionQuantity DBS 40 DBS 72 DBS 96 IVB-43210 ]16-key standard telephone with handsfree VB-43220answerback22-key standard telephone with handsfree I1 answerbackI1 VB-4322 122-key speakerphone V-B -4322322-key speakerphone with LCD display32 VB-4322522-key speakerphone with large LCD display MS-4323034-key telephone with handsfree answerback MS-4323 134-key speakerphone VB-4323334-key speakerphone with LCD display 5672 DES-70-300DBS Manual - issued 8/T/957-7

Chapter 7. SpecificationsSection 3004nstallation Part No.DescriptionQuantity DBS 10DBS 72DBS 96 Phone Options VB-433 1024-key expansion module (EM24)162836 VB -4332072-key DSS/BLF module (DSW72)CPC-A and CPC-AII: 4 CPC-B: 8 (up to 4 can be assigned as DSW72s; up to 4 can be assigned as Attendant Consoles) VB-438847 ft. handset cord VB-43885 15 ft. handset cord VB-4388625 ft. handset cord325672 VB-43890K-type handset Printed Circuit Cards VB-43110Cable kit for 2-system connectionN/AN/AN/A VB-43410Call processor card (CPC-A) VB-43411Call card (CPC-B)processor111 VB-43412Call processor card (CPC-AH) VB-43420Service circuit card (SCC-A) VB-4342 1Service circuit card (SCC-B)111 VB -4343 1DTMF signal receiver for 8.SLT lines (MFW8)111 VB-435104-port loop-start trunk card (L-TRK/4) VB-43511g-port loop-start trunk card (L=rRK/8)234 VB-43541Direct-inward-dialing trunk card (DID) VB-4353 1g-port ground-start trunk card G-m/8) VB-4356 1Tl Interface11_ 1 VB-43562Tl MDF card111 VB-43563Tl Sync Unit111 VB-436 11g-port digital extension card (DEC)479 VB-4362 1g-port analog extension card (AEC)344 7-8DBS Manual - Issued 8/l/95DBS-70-300

Section Zoo-installationChapter 7. Speci!icatlor!s Part No.i DescriptionIQuantitpIIjDBS40 lDBS72 iDBS96 / Expansion Connectors VB-43120Trunk expansion connector1VB-43121Extension expansion connector11 VB-4370 1 VB -43705 Doorbox Equipment (Trunk) Door box adaptor8”12”16* Door box16*24*32* Doorbox Equipment (Extension) VB -437 11Extension-Based Door box adaptor444 VB-43705Door box444 Optional Equipment VB-43706Remote Administration Interface @AI-A)11V-B -43707Remote Administration Interface @AI-B)1 VB-435518-circuit Caller ID daughter board1 per1 peri pet VB-\;B-VB- 435liA43511A.43511x XECAECAEC *VB -43 130Built-in system backup batteries111 VB-43709( Single Line Telephone AdaptorI 8 I 13 I 18 I VB-2089PSLT ringer boxf 111 VA-437034-line power failure unit688 VB -43702Off-premise extension adaptor88s VB -43940Application processor interface (API)111 VB-4399 1PCAS software1VB-43993DBS Manager software * Note: These maximums are based on overall trunk capacities and do not allow for trunks used for outside lines.DBS-70-300DBS Manual - Issued 8/l/95 .7-9

ChaDter 7. SoecificationsSection 300~Instailation Table 7-10. Hardware maximums for do&e-cabinet systems Part No.DescriptionQuantity ++++++sg gsixeswm gggg gg ggkg yg =c CEi Elf Q,r3 cc: =a PhonesVB-43210 l&key keyphone w/ handsfree answerbackVB-43220 22-key keyphone w/ handsfree answerback VB-4322 122-key speakerphone VB-43223 22-key speakerphone w/LCD display56 72 104104128 144 VB-43225 22-key speakerphone w/ large LCD displayVB-43230 34-key keyphone w/ handsfree answerback VB-4323 1 ,34-key kcyphone VB-43233i34-key keyphone w/ LCD display Phone Options VB -433 1024-key expansion32 44 56 52 64 72 module (EM24) VB-43320 72-key DSS/BLF module (DSS/72)CPC-A and CPC-AU: 4 CPC-B (Version 2.0 to 4.0 only): 8 (up to 4 can be assigned as DSS/72s; up to 4 can be assigned as Attendant Consoles) VB-438847 ft. handset cord VB-43885 15 ft. handset cord VB-4388656 72104104128144 25 ft. handset cord VB-43890 K-type handsetI7-10 DBS Manual - Issued 8/l/95DBS-70-300

Section 300~InstallationChapter 7. Specifications L1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Part No.DescriptionIQuantity Print zd Circuit Cards CrB-43 1101 Cable kit for 2-cab. systems11 irB-43410Call processor card (CPC-A) a-4341 1Call processor card (CPC-B) a-434 12Call processor card (CPC-AU)m-43420 Service circuit card (SCC-A) irB-43421Service circuit card (SCC-B) irB-43431DTMF signal receiver for 8 (L-TRK/4) irB-435 118-port loop-start trunk card (L-TRK/Q irB-43541 8-port Direct-inward-dialing 33 trunk card (DID)I irB-4353 18-port ground-start @unk card (G-TRK/8) irB-43561 Tl Interface10 dB-43562 Tl MDF Card10 irB-43563 Tl Sync Card10 (B-4361 1 8-port digital extension card79 WC) JB-436218-port analog’extension card WC) 6 7 JB-435518-port Caller ID Daughter1 per1 per Board (used with Loop Start VB-VB- Trunk Card VB-435 11A)43511A 43511A 1 1 1 2 122 111 131316 8788per 1 per1 perL per JB-v.B-VB-dB- I3511At3511A&3511AC3511A 11 1 2 8 2 2 1 18 DES-70-300DBS Manual - Issued 8/T/957-11

Chapter 7. SpecificationsSection 300~Installation Part No.DescriptionQuantity ++++++ s %R$cF3 s82gg vl*mminmz?~~wHu3SaZ~ZsiCCac3CQ Expansion Connectors VB-43120Trunk connectorexp.222222VB-43121Ext. connectorexp.1*0” Doorbox Equipment (Trunk Port) VB -4370 1Door box adaptor12#12# 2M 2#28#32# VB-43705Door box24# 24# 40#48# 56# 64# Doorbox Equipment (Extension Port) VB-437 11Doorbox adaptor444444 VB-43705Doorbox444444 Optional Equipment VB-43706Remote Administration Interface (R-41-A) VB-43707Remote Administration1’ 11 111 Interface (RAI-B) VB-43130Built-in system backup batteries 2 22222ml-43709 SLT Adaptor16 2228 26 32 36 *An expansion connector is not required to use an extension card in the EC/IRK slot of a DBS 96. The DBS 96 uses connector CN14 to accommodate an extension card in the EC/IRK slot. # These maximums are based on overall trunk capacities and do not allow for trunks used for 1outside lines.7-12 DBS Manual - Issued 8/l/95DES-70400

Section 300~InstallationChapter 7. Specifications Cabling Specifications Table 7-11. Maximum cabling distances Loop Type and Resistancetesistance Key phone, EM/24 DSSl72 SLT100 Ohms OPX (Loop between the DBS and the OPX Adaptor) OPX (Loop between the OPX Adaptor and a pushbutton SLT) Doorphone (Loop between the DBS and the Doorphone Adaptor) Doorphone (Loop between the Doorphone Adaptor and the Door- phone) Voice hmounce Unit10 Ohms 40 Ohms 20 Ohms 10 Ohms 900 Ohms (excluding end impedance) 10 Ohms 40 OhmsCable Gauge (AWG) 22 24 26 22 24 26 Maximum Cabling Length in Feet (Distance from the DBS) 1239 779 490 619 388 244 223097 24 1948 261225 22 309 24 194 26 122 2227877 24 17532 2611025 22I309I 24I 26122 22123926 1122 DES-70-300DBS Manual - Issued 9/l/957-13

Cliapter 7. SpecificationsSection 300~Installation Communication Parameters Tuble 7-12. Voice path from KTELs to DBS n ChannelOverall conununicadons path 1 D-channel data 1256 kbps 116 kbps 1 B-channel data164 kbps Table 7-13. Data communications portsParameters ISMDRInterfaceRS233-CBaud rate 300,1200,4800 or 9600 kbps ParityEven, odd, or none Stop bit length1, 1.5, or 2Data bit length5, 6,7, or 8 1Maintenance(RAIcard)Baud rate300 (RAI-A) or 300 or 1200 (RAI-B) Stop bit length1Data bit length 8 .ParityNone 7-14DBS Manual - Issued 8/l/95DES-70-300

Section 3004nstallationChapter 7. Specifications Signaling Characteristics Table 7-14. Signaling to CO ItemSpecification Dial pulse8 to 11 pulses per second (PPS) Break ratio 58 to 64% Minimum pause0.7 to 1.0 seconds Trunk startLoop or ground start Table 7-15. Signaling le vets ItemLevelDistortion Trunk input (DISA)-40 dBm (minimum)Less than 10% Output from DBS (at MDP) High level: -8 dBm (minimum) Low level: -10 dBm (minimum) Analog station input (Dial-35 dBm (minimum)Less than 10% status) Analog station output (Talk High level: -8 dBm+/-0.5 dBmLess than 5% Path originated from a keYLow level: -6 dBm+/-0.5 dBm phone to an SLT) Table 7-16. Transmission specifxations Item bnpedance Overload level bertion Loss CO trunk to analog station Analog station to CO trunk CO trunk to digital station Digital station to CO trunk Digital station to digital station Digital station to analog station Analog station to digital station Analog station to analog station Specification 600 Ohms 600 Ohms OdB OdB OdB OdB6dB 6 dB6dB 6dB DBS-70-300DBS Manual - Issued 8/T/957-15

Chapter 7. SpecificationsSection 3004nstallation Tone Characteristics Table 7-17. Tone Plan Tone NameFrequencyTiming (seconds) CO Call Tones CO incoming call550/400 Hz at 16 HzProgrammable Hold recall 550/400 Hz at 16 Hz0.5 on/35 off Transfer recall550/400 Hz at 16 Hz0.5 on/35 off Trunk queuing550/400 Hz at 16 Hz0.5 on/O.5 off/O.5 on/2.5 off CO ofiook signal550 Hz1 on/7 off Internal Tones (Key Phones) Dial tone400 HzContinuous CO incoming call 550 Hz1 on/3 off (Prior to CPC-B 3.1) Programmable (CPC-AII and CPC-B 3.1 or higher) Callback400 Hz1 on/3 off Busy 400 Hz0.5 on/O.5 off Busy override400 Hz0.25 on/O.25 off/O.25 on Splash550 Hz0.5 on Error400 Hz0.5 on/O.5 off Reminder call550 Hz4 on/l off/4 on/l off/4on 1 off/4 on/silence Call waiting550 Hz0.25 on/O.25 off/O.25 on/7.25 off Key press 1kHzDuration of the key press Internal Tones (SLTs) CO/Station ringing20 Hz1 on/3 off Hold recall Callback Transfer (Prior to 20 Hz0.5 on/3.5 off CPC-B 2.11) Transfer (CPC-AII20 HzProgrammable and CPC-B 2.11 or higher)7-16DES Manual - issued 6/l/95DBS-70-300