    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Section 300~InstallationChapter 4. Trunks and Lines
    Installing Tl in a Double Cabinet with Tls in the Master and Slave
    1.
    2.
    3.
    4.
    * 5.
    6.
    7.
    8.
    Cl,.
    Install the Sync Unit in the master cabinet as described in Steps 1 and 2
    under “Installation for a Single Tl.”
    Install a Tl MDF card in each cabinet. (See Step 3 on page 4-23.)
    Set Switch 1 on the 
    Tl cards. (See Step 4 on page 4-24.)
    Install a 
    Tl card in each “EC/TRK” slot.
    Connect the Clock Sync Cable from CN4 on the master-cabinet 
    Tl to
    CN5 on the slave-cabinet Tl, as shown in Figure 4-12.
    Note: Part Number VB-43564 is used for the Clock Sync Cable when Tls
    are installed in the master and slave cabinets.
    At the master cabinet, connect the Sync Cable from 
    CNl on the Sync
    Unit to 
    CN5 on the Tl card (Figure 4-12).
    At each cabinet, connect the cable attached to CN3 on the 
    Tl MDF card
    to CN3 on the 
    Tl card (Figure 4-10).
    Using an RJ48 cable, connect 
    CNl of each Tl MDF card to a CSU. (See
    Figure 4-9 on page 4-25 for RJ48 pinouts.)
    For both cabinets, connect the ground cable from the 
    Tl MDF card as
    shown in Figure 4-10 on page 4-26.
    DBS-70-300DES Manual - Issued 8/l/954-29 
    						
    							clnaprer 4. I I UI IW dl IU LII w83wAIcJrI Juu-lrlstallaIlorl
    Figure 4-i2. Clock sync cable and sync cable connections, double-cabinet instuttiztionCard
    Label
    \
    411
    I
    /I
    i
    1Card
    Label’
    Slave Cabinet
    lots: The number of analog trunks that can bri&zled depends on how many Tl channels are
    Gl
    CNS
    nterconnectionCables
    4-30DBS Manual - Issued 8/l/95DBS-70-300 
    						
    							Section 300~InstallationChapter 4. Trunks and Lines
    Lines
    Extension Connectors
    The number of extension ports that can be connected to your system depends
    on the type of system you have. 
    Egure 4-13 shows the maximum number of
    extensions that can be connected to each system when the extension
    expansion connector is used.
    Table 4-l summarizes the number of ports that can be used without the
    extension expansion connector. Chapter.6 includes extension maximums for
    two-cabinet systems.
    mre 4-13. DBS extension connectionsTo 
    CNI on ths Extension
    49-56
    To
    To
    ToExpansion Connector
    m-43121
    Extension 25
    Extension 32
    Extension 1Extension 24
    Extension 25
    DES 72
    J
    and 96
    Extension 46
    Extension 49
    ‘I
    J
    DSS 96only
    Extension 72DBS-70-300DBS Manual 
    - Issued 8/1’/954-31 
    						
    							Table 4-19. Extension ports provided with each system
    System Type
    DBS 40
    DBS 72
    1-48
    DBS 96l-72
    Extension Ports
    (Not including the Expansion Connector*)l-24
    *Note: Extensions 65 to 72 on the DBS 96 use the EC/TRK slot, but they
    do not require the extension expansion connector. If extensions 65 to 72 are
    used, the trunk expansion connector cannot be used.
    Extension Connector Pinouts
    Tables 4-20 through 4-22 provide pinouts and color codes for extension
    slots.Table 4-22 on page 4-35 provides 
    pinouts and color codes for the
    extension expansion connector.
    Instructions on installing the expansion connector begin on 4-43.
    4-32DBS Manual - Issued 8/l/95DBS-70-300 
    						
    							Table 4-20. Pinoats and color codes for extension connector CN12
    Extension Slot
    Color CodePin No.
    Desig.
    EC1W-H-BL261T
    (DBS JO.BL-WH1IR
    DBS72.WH-OR272T
    DBS 96)OR-WH22R
    WH-GN283T
    GN-WH
    33R
    WH-ER29ST
    Function
    Extension
    Port1
    Extension
    Port2
    Extension
    Port3
    ExtensionPort4
    Note: Only digital extensions can be used in slot ECl. Port 1 is reserved for Attendant 1 and requires a Display Key Phone.
    DES-70-300DBS Manual - Issued 8/l/95 
    						
    							Chapter 4. Trunks and LinesSection 300-Installation
    Table 4-21. Pinouts and color codes for extension connector CN13
    DES Manual - Issued 8/l/95DBS-70-300 
    						
    							Section 300~installationChapter 4. Trunks and Lines
    Table4-22. Pinoutsand color
    codes forextensionconnector
    CN14
    ExtensionSlot1ColorCode1PinNo.1Desig.1Function
    EC7WH-BL261T(Extension Port 49
    @BS 96 Only)
    GN-RD
    88R
    EC8
    RD-BR349TExtension
    Port57(DBS96Only)
    BR-RD99R
    RD-SL3s10TExtension Port 58
    SLRD1010R
    BK-BL3611TExtensionPan59BLBK
    1111R
    BK-OR3712TExtension
    Port60
    ECflRK
    OR-BKBKGN
    GN-BK
    BK-BR
    BR-BK
    BK-SL
    SL-BKYLBL
    BL-YL
    YL-OR
    OR-YL
    YL-GN
    .
    1212R
    38
    13T
    1313R
    39
    I4T
    1414R
    4015T
    1515R
    4116T
    1616R
    4217T
    ExtensionPan61
    Extension
    Port62
    Extension
    Port63
    Extension
    Port64
    Extension
    Pon65
    (DBS 96only)1717R
    I4318T1Extension Pan 66
    GN-YL
    18YLBR
    44
    BR-YL19
    YLSL45
    18R
    19T
    19R
    20T
    Extension
    Port67
    Extension
    Port68
    SL-YL
    VI-BL20I20R
    46
    21T
    1Extension Port 69BLVI
    VI-OR
    OR-VIVIGN
    GN-VI
    VI-BR
    BR-VI
    VI-SL
    2121R
    47
    22T
    22
    22R
    48
    23T
    ExtensionPort70
    ExtensionPort71
    2323R
    49
    24T
    24
    24R
    50Not usedExtension Port 72
    ISL-VII25I
    Note: The EC/IRK slot is wired to CN14 only in the DBS 96. In the DBS 40 and
    72, a card placed in the ECFRK slot must be wired to the expansion connector.
    DBS-70-300
    DBS Manual - Issued W/954-35 
    						
    							-‘.-r.-. ..-.--w-w..-.. v-w . ..“.“..W..“.,
    Table 4-23. Pinouts and color codes for extension expansion connector CNl
    1
    ECirRKWH-BL
    BL-WH
    WH-OR
    OR-WH
    WH-GN
    GN-WH
    WH-BR
    BR-WH
    WH-SLSLWH
    RD-BL
    BL-RD
    RD-OR
    OR-RD
    RD-GN
    GN-RD
    261T
    11R
    272T
    22R
    283T
    33R
    29
    4T
    44R
    30
    5T
    55R
    316T
    66R
    32
    7T
    77R
    33
    8T
    88R
    DBS40DBS72DBS%
    ExtersionExtension
    Port 25Port 49
    Extension
    Extension
    Port 26Port 50
    No
    ExtensionExtension
    Extension
    Port 27
    Port 51Expansion
    Card
    ExtensionExtensionRequired
    Port 28Port 52(uses
    CN14
    Extension
    Extension
    Port 29Port 53
    iIl!Stt?d)
    ExtensionExtension
    Port 30Port 54
    ExtensionExtension
    Port 31Port 55
    Extension
    Extension
    Port 32Port 56
    4-36DBS Manual-lssued6/1/95DBS-70-300 
    						
    							Section 300~InstallationChapter 4. Trunks and Lines
    Analog Extensions
    Note: Normally analog extensions are supported using the AEC (VB-4362 1).
    Alternatively, a Single Line Telephone Adaptor (SLTA, VB-43709) may be
    used to support analog DTMF (2500 set) extensions. The SLTA converts up
    to 4 digital ports to analog ports. See “Single Line Telephone Adaptor” on
    page 5-34 for more information.
    Guidelines
    lAn MFR card (VB-43431) is required when the AEC is used. The MFR
    card, which provides DTMF signals, includes eight circuits that are shared
    among the analog extensions.
    lThe AEC also requires the SLT ringer.box (VB-2089P).
    Installation
    1.Install the AEC cards in extension slots.
    2.Install the MFR card in AUXl or AUX2. If installing in a two-cabinet
    system, see Chapter 6 for specific information for installing MFR card(s).
    3.Install the SLT Ringer Box as shown in Figure 4-14. Be sure to note the
    differences between the DBS 40 Connector Panel and the Connector
    Panel on the DBS 72 and 96.DBS-70-300DBS Manual 
    - Issued 8/l/954-37 
    						
    							Chapter 4. Trunks and Lines
    Section 3004nstallation
    Figure 4-14. SLT ringer box installation
    Ringer box installation with the DBS 72 and DBS 96
    1CN2RG-48V SG SYN RG +24V GND CSM 20 Zl 22 23 24 RE2 REl
    (OlOlQlQl ~lQlolololololololololo)
    Ringer box installation with the DBS 40
    I
    SLT Rin8er Box(V&2 89P)
    RG& CN2
    SG 
    -48v SYN RG GND +24V MCB ZO Zl 22 23 24 RE2 RElI\
    [olololQlQ~~~olo~ololoio~oloi0lol
    I
    !
    I
    SLT Ringer Box(vs-2099P)
    4-38DES Manual - Issued 8/l/95DES-70-300 
    						