Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Chapter 1. System Programming (FFl)Section 400-Programming Table l-47. Digital Pad Setthgs - pad numbers and related dB levels Table l-48. Digital Pad Settings - default values Related ProgrammingTrunk Port Class: FF2 (Trunk)# 26# (4-8)#Station Port Class: FF3 (ExtPort)# 37# (l-2 or 7-8)# Page 1-156DBS Manual - Issued 8/l/95DBS-70-400
Section 400-ProgrammingChapter 1. System Programming (FFl) NotesExample Digital Pad Adjustment.If calls to SLTs via a master Tl have low volume levels, the pad levei for connections from the master Tl to all SLTs can be changed. By default, the pad level for connections from the master Tl to all SLTS is 16 (or -2 dB). To raise the volume by 2 d.B, change the pad value to 0 (or 0 dB) by programming the following: FFl 8# 4# 3## 2# !5f# O## where:2% is the circuit type for SLTs; 5# is the circuit type for Tl in the master cabinet; and O#I is the pad number for 0 dB loss/gain. DES-70-400DBS Manual - Issued 8/l/95Page l-l 57
Chapter 1. System Programming (FFl)Section 400-Programming Trunk Configuration Software Version:CPC-BVersions 4.0to6.02Address: Master Cabinet: FFl 8# 4## 4## 1# I# (0 or l)# Slave Cabinet:FFl 8# 4# 5# 1# 1# (0 or l)# DescriptionSpecifies the trunk combinations used in the DBS system (analog trunks only by default). Setting this address to “Tl and Analog trunks” tells the DBS system that Tl and analog trunks are being used in the same cabinet. (Each Tl channel uses up one trunk port on the analog trunk card.) Programming I FFI 8# 4# (4 or 5)# 1# 1# (0 or l)# ++ 4=Master CabinetO=Analog trunks only. 5=Slave Cabinetl=Tl and Analog trunks. Related ProgrammingNumber of Tl Channels: FFl 8# 4# (4 or 5)# l# 2# (0-24)# Tl TrunkClosure: FFl 8# 7# (1 or 2)# (l-4)# (l-8)# (0 or l)# Trunk Circuit Type:F’F2 (Trunk)# 21# (0-3)# NotesPower-Cycling Requirement.For changes to this parameter to take effect, the system must,be turned off, then back on. CPC-B Versions Beginning With 6.03.The Trunk Configuration address is no longer present --simply use the Trunk Circuit Type address to assign trunk ports as Loop-Start, Ground-Start, DID or Tl trunks. Page 1-158DBS Manual - Issued 8/l/95DBS-70-400
Section 400-Programming Chapter 1. System Programming (FFl) Number of Tl ChannelsSoftware Version: CPC-B Version 4.0 or higher Address: Master Cabinet: FFl 8# 4# 4## 1# 2# (0-24)# Slave Cabinet: FFl 8# 4# 5# l# 2# (O-24)# DescriptionThis program determines how many TI channels will be used in the DBS system. This address provides “Fractional Tl” capability -- using only a portion of the 24 available channels on the Tl card. Since each Tl channel used will need one analog trunk port dedicated to it, this setting will decrement the number of available analog trunk ports -- in other words, each Tl channel used will subtract from the total number of trunk ports available for analog usage. In CPC-B 4.x versions (prior to 5.0), the entry for Number of Tl Channels must be in increments of 8. This is because the entire analog trunk card (all 8 trunk ports on the same card) must be dedicated to Tl, even if only some of the ports are used for Tl channels. In other words, the remaining (unused) ports on the card are not available for use as analog trunks. In CPC-B Version 5.0 and above, those remaining ports cuz be used as analog trunks. Make sure the Number of Tl Channels setting equals the number of trunks programmed for Tl in Trunk Circuit Type (FF2 Trunk# 21#). Programming II FFI 8# 4# (4 or 5)# I# 2# (0-24)# +$ 4=Master CabinetNumber of Tl Channels Used 5=Slave Cabinet NOTE: In CPC-B versions prior to 5.0, this setting must be an increment of “8” (0, 8, 16 or 24). Related Programming Trunk Configuration:FFl 8# # (4 or 5)# l# l# (0 or l)# Tl Trunk Closure: FFl 8# 7# (1 or 2)# (l-4)# (l-8)# (0 or l)#Trunk Circuit Type: FF2 (Trunk)# 21# (0-3)# NotesPower-Cycling Requirement.For changes to this parameter to take effect, the system must be turned off, then back on. Closing Analog Trunk Ports for Tl Usage.In CPC-B Versions 5.0 to 6.02; make sure the trunk ports reserved for Tl are “closed” from loop-start usage in the Tl Trunk Closure address (FFl 8# 7#). DBS-70-400DBS Manual - Issued 8/l/95Page l-159
Chapter 1. System Programming (FFl)Section 400-Programming Frame Format Software Version: CPC-6 Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4# l# 3# (0 or l)# Slave Cabinet:FFl 8# 4# 5# l# 3# (0 or l)# DescriptionSelects the framing format used by the Tl. Either “Superframe” (SF) or “Extended Super-frame” (ESF) can be selected. The SF consists of 12 frames, with each frame including 192 information bits and 1 framing bit. The ESF consists of 24 frames (double the length of the SF format). ESF also supports monitoring and maintenance capabilities that are not available with the SF format. Programming FFl 8# 4# (4 or 5)# l# 3# (0 or l)# ft 4=Master CabinetO=Superframe (SF) 5=Slave Cabinetl=Extended Super-frame (ESF) NotesCentral Office Requirement.The framing format must match what is ordered from the CO. Power-Cycling Requirement.For changes to this parameter to take effect, the system must be turned off, then back on. Page l-160DBS Manual - Issued 8/l/95DBS-70-400
Section 400-ProgrammingChapter 1. System Programming (FFI) Line Coding Software Version:CPC-B Version 4.0 or higher.Address: Master Cabinet: FFl 8# 4# 4# 1# 4# (0 or I)# Slave Cabinet:FFl 8# 4## 5## l# 4# (0 or l)# DescriptionSelects the line coding format used by the Tl. Either “BSZS” (binary g-zeros suppression) or “AMP (Alternate Mark Inversion) can be selected. In most cases (and by default), AMI is used. Programming I~ Notes FFl 8# 4# (4 or 5)# l# 4# (0 or l)# ff 4=Master Cabinet 5=Slave Cabinet O=AMI (Alternate Mark Inversion) l=B8ZS (binary g-zeros suppression) Central Ofice Requirement.The framing format must match what is ordered from the CO. Power-Cycling Requirement.For changes to this parameter to take effect, .the system must be turned off. then back on. DBS-70-400DBS Manual - Issued 8/l/95Page 1-161
Lnapter 1. System Programming (FFl)sectlon 400~Programming Failure Mode Software Version:CPC-6 Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4## 4## I# 5# (0 or l)# Slave Cabinet:FFl 8# 4# 5# l# W (0 or l)# DescriptionDetermines the way the system responds to alarms. By default, the system will continue to operate even if errors are detected. Programming I FFl 8# 4## (4 or 5)# 1# 5# (0 or I)# ff 4=Master Cabinet 5=Slave Cabinet O=Mode 1 (the Tl continues to operate even if errors are detected) l=Mode 2(the Tl shuts down if errors are detected) NotesPower-Cycling Requirement.For changes to this parameter to take effect, the system must be turned off, then back on. P?ge l-l 62DBS Manual - Issued 8/l/95DBS-70-400
Section 400-Programming Chapter 1. System Programming (FF1) Remote Loopback Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4#I 4# l# 6# (0 or l)# Slave Cabinet:FFl 8# 4# 5# l# 6# (0 or l)# DescriptionThis address is reserved for future use. DBS-70-400DBS Manual - Issued 8/l/95.Page l-163
Chapter 1. System Programming (FFl)Section 400-Programming Yellow Alarm Send Software Version: CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4## 4# 1# 7# (0 or l)# Slave Cabinet:FFl 8# 4## 5# 1# 7W (0 or l)# DescriptionDetermines whether the DBS sends a yellow alarm signal to the CO. A yellow alarm is sent to the distant end of the Tl link to indicate that a red alarm has occurred. If a red alarm occurs at the CO, the CO sends a yellow alarm to the DBS. If a red alarm occurs at the DBS, the DBS sends a yellow alarm to the CO. Programming I FFl 8# 4# (4 or5)# l# 7# (0 or l)# +f 4==Master CabinetO=No 5=S1 ave Cabinetl=Yes Related ProgrammingYellow Alarm Detection: FFl’ 8# 4# (4 or 5)# 2# 2# (0-15)# Yellow Alarm Recovery: FFl 8# 4# (4 or 5)# 2# 3# (0-15)#Yellow Alarm Counter: FFl 8# # (4 or 5)# 3# 6# (0-15)# Yellow Alarm Relay: FFl 8# 4# (4 or 5)# 4# l# (0-15)# Yellow Alarm FF Key: FF5 (ExtPort)# (Key)# CONF (107# or 127#)# Page 1-164DBS Manual - Issued 8/l/95DBS-70-400
Section 400-ProgrammingChapter 1. System Programming (FFl) Flash Key Operation Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8## 4## 4## l# 8# (0 or l)# Slave Cabinet:FFl 8## 4# 5# 1# 8# (0 or l)# DescriptionIn the current version of DBS Tl, a “switchhook flash” releases and reseizes the Tl line. Programming 11 FFl 8# 4#I (4 or 5)# l# 8# (0 or l)# $$ 4=Master CabinetO=Release and reseize 5=Slave Cabinetl=Reserved for future use DBS-70-400DBS Manual - Issued 8/l/95Page 1-165