Home > Panasonic > Communications System > Panasonic Cpc+AII/B Digital Business System Release Notes Manual

Panasonic Cpc+AII/B Digital Business System Release Notes Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Table l-47. Digital Pad Setthgs - pad numbers and related dB levels
    Table l-48. Digital Pad Settings 
    - default values
    Related ProgrammingTrunk Port Class: FF2 
    (Trunk)# 26# (4-8)#Station Port Class: FF3 
    (ExtPort)# 37# (l-2 or 7-8)#
    Page 1-156DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    NotesExample Digital Pad Adjustment.If calls to SLTs via a master Tl have low
    volume levels, the pad levei for connections from the master Tl to all SLTs
    can be changed.
    By default, the pad level for connections from the master 
    Tl to all SLTS is 16
    (or -2 dB). To raise the volume by 2 d.B, change the pad value to 0 (or 0 dB)
    by programming the following:
    FFl 8# 4# 3## 2# !5f# O##
    where:2% is the circuit type for SLTs;
    5# is the circuit type for Tl in the master cabinet; and
    O#I is the pad number for 0 dB loss/gain.
    DES-70-400DBS Manual - Issued 8/l/95Page l-l 57 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Trunk Configuration
    Software
    Version:CPC-BVersions
    4.0to6.02Address: Master Cabinet: 
    FFl 8# 4## 4## 1# I# (0 or l)#
    Slave Cabinet:FFl 8# 4# 5# 1# 1# (0 or l)#
    DescriptionSpecifies the trunk combinations used in the DBS system (analog trunks only
    by default).
    Setting this address to “Tl and Analog trunks” tells the DBS system that Tl
    and analog trunks are being used in the same cabinet. (Each Tl channel uses
    up one trunk port on the analog trunk card.)
    Programming
    I
    FFI 8# 4# (4 or 5)# 1# 1# (0 or l)#
    ++
    4=Master CabinetO=Analog trunks only.
    5=Slave Cabinetl=Tl and Analog trunks.
    Related ProgrammingNumber of 
    Tl Channels: FFl 8# 4# (4 or 5)# l# 2# (0-24)#
    Tl TrunkClosure: FFl 8# 7# (1 or 2)# (l-4)# (l-8)# (0 or l)#
    Trunk Circuit Type:F’F2 (Trunk)# 21# (0-3)#
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system 
    must,be turned off, then back on.
    CPC-B Versions Beginning With 6.03.The Trunk Configuration address
    is no longer present --simply use the Trunk Circuit Type address to assign
    trunk ports as Loop-Start, Ground-Start, DID or 
    Tl trunks.
    Page 1-158DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-Programming
    Chapter 1. System Programming (FFl)
    Number of Tl ChannelsSoftware Version: CPC-B Version 4.0 or higher
    Address: Master Cabinet: 
    FFl 8# 4# 4## 1# 2# (0-24)#
    Slave Cabinet:
    FFl 8# 4# 5# l# 2# (O-24)#
    DescriptionThis program determines how many TI channels will be used in the DBS
    system. This address provides “Fractional 
    Tl” capability -- using only a
    portion of the 24 available channels on the 
    Tl card.
    Since each 
    Tl channel used will need one analog trunk port dedicated to it,
    this setting will decrement the number of available analog trunk ports -- in
    other words, each 
    Tl channel used will subtract from the total number of
    trunk ports 
    available for analog usage.
    In CPC-B 4.x versions (prior to 5.0), the entry for Number of Tl Channels
    must be in increments of 8. This is because the entire analog trunk card (all 8
    trunk ports on the same card) must be dedicated to 
    Tl, even if only some of
    the ports are used for 
    Tl channels. In other words, the remaining (unused)
    ports on the card are not available for use as analog trunks.
    In CPC-B Version 5.0 and above, those remaining ports cuz be used as analog
    trunks. Make sure the 
    Number of Tl Channels setting equals the number of
    trunks programmed for 
    Tl in Trunk Circuit Type (FF2 Trunk# 21#).
    Programming
    II
    FFI 8# 4# (4 or 5)# I# 2# (0-24)#
    +$
    4=Master CabinetNumber of Tl Channels Used
    5=Slave Cabinet
    NOTE: In CPC-B versions prior to 5.0, this setting must be an increment
    of “8” (0, 8, 16 or 24).
    Related Programming
    Trunk Configuration:FFl 8# # (4 or 5)# l# l# (0 or l)#
    Tl Trunk Closure: FFl 8# 7# (1 or 2)# (l-4)# (l-8)# (0 or l)#Trunk Circuit Type: FF2 
    (Trunk)# 21# (0-3)#
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    Closing Analog Trunk Ports for Tl Usage.In CPC-B Versions 5.0 to 6.02;
    make sure the trunk ports reserved for Tl are “closed” from loop-start usage
    in the Tl Trunk Closure address (FFl 8# 7#).
    DBS-70-400DBS Manual - Issued 8/l/95Page l-159 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Frame Format
    Software Version: CPC-6 Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# l# 3# (0 or l)#
    Slave Cabinet:FFl 8# 4# 5# l# 3# (0 or l)#
    DescriptionSelects the framing format used by the Tl. Either “Superframe” (SF) or
    “Extended Super-frame” (ESF) can be selected.
    The SF consists of 12 frames, with each frame including 192 information bits
    and 1 framing bit. The ESF consists of 24 
    frames (double the length of the SF
    format). ESF also supports monitoring and maintenance capabilities that are
    not available with the SF format.
    Programming
    FFl 8# 4# (4 or 5)# l# 3# (0 or l)#
    ft
    4=Master CabinetO=Superframe (SF)
    5=Slave Cabinetl=Extended Super-frame (ESF)
    NotesCentral Office Requirement.The framing format must match what is
    ordered from the CO.
    Power-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    Page l-160DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFI)
    Line Coding
    Software Version:CPC-B Version 4.0 or higher.Address: Master Cabinet: 
    FFl 8# 4# 4# 1# 4# (0 or I)#
    Slave Cabinet:FFl 8# 4## 5## l# 4# (0 or l)#
    DescriptionSelects the line coding format used by the Tl. Either “BSZS” (binary g-zeros
    suppression) or “AMP (Alternate Mark Inversion) can be selected. 
    In most
    cases (and by default), 
    AMI is used.
    Programming
    I~
    Notes
    FFl 8# 4# (4 or 5)# l# 4# (0 or l)#
    ff
    4=Master Cabinet
    5=Slave Cabinet
    O=AMI (Alternate Mark Inversion)
    l=B8ZS (binary g-zeros suppression)
    Central Ofice Requirement.The framing format must match what is
    ordered from the CO.
    Power-Cycling Requirement.For changes to this parameter to take effect,
    .the system must be turned off. then back on.
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-161 
    						
    							Lnapter 1. System Programming (FFl)sectlon 400~Programming
    Failure Mode
    Software Version:CPC-6 Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4## 4## I# 5# (0 or l)#
    Slave Cabinet:FFl 8# 4# 5# l# W (0 or l)#
    DescriptionDetermines the way the system responds to alarms. By default, the system
    will continue to operate even if errors are detected.
    Programming
    I
    FFl 8# 4## (4 or 5)# 1# 5# (0 or I)#
    ff
    4=Master Cabinet
    5=Slave Cabinet
    O=Mode 1 (the Tl continues to
    operate even if errors
    are detected)
    l=Mode 2(the Tl shuts down if
    errors are detected)
    NotesPower-Cycling Requirement.For changes to this parameter to take effect,
    the system must be turned off, then back on.
    P?ge l-l 62DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-Programming
    Chapter 1. System Programming (FF1)
    Remote Loopback
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4#I 4# l# 6# (0 or l)#
    Slave Cabinet:FFl 8# 4# 5# l# 6# (0 or l)#
    DescriptionThis address is reserved for future use.
    DBS-70-400DBS Manual - Issued 8/l/95.Page l-163 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Yellow Alarm Send
    Software Version:
    CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4## 4# 1# 7# (0 or l)#
    Slave Cabinet:FFl 8# 4## 5# 1# 7W (0 or l)#
    DescriptionDetermines whether the DBS sends a yellow alarm signal to the CO.
    A yellow alarm is sent to the distant end of the 
    Tl link to indicate that a red
    alarm has occurred. If a red alarm occurs at the CO, the CO sends a yellow
    alarm to the DBS. If a red alarm occurs at the DBS, the DBS sends a yellow
    alarm to the CO.
    Programming
    I
    FFl 8# 4# (4 or5)# l# 7# (0 or l)#
    +f
    4==Master CabinetO=No
    5=S1 ave Cabinetl=Yes
    Related ProgrammingYellow Alarm Detection: 
    FFl’ 8# 4# (4 or 5)# 2# 2# (0-15)#
    Yellow Alarm Recovery:
    FFl 8# 4# (4 or 5)# 2# 3# (0-15)#Yellow Alarm Counter: 
    FFl 8# # (4 or 5)# 3# 6# (0-15)#
    Yellow Alarm Relay: 
    FFl 8# 4# (4 or 5)# 4# l# (0-15)#
    Yellow Alarm FF Key: FF5 
    (ExtPort)# (Key)# CONF (107# or 127#)#
    Page 1-164DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Flash Key Operation
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8## 4## 4## l# 8# (0 or l)#
    Slave Cabinet:FFl 8## 4# 5# 1# 8# (0 or l)#
    DescriptionIn the current version of DBS Tl, a “switchhook flash” releases and reseizes
    the 
    Tl line.
    Programming
    11
    FFl 8# 4#I (4 or 5)# l# 8# (0 or l)#
    $$
    4=Master CabinetO=Release and reseize
    5=Slave Cabinetl=Reserved for future use
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-165 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cpc+AII/B Digital Business System Release Notes Manual