    Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 1046
    							Chapter 1. System Programming (FFl)Section 400-Programming
    Red Alarm Counter
    Software Version:WC-6 Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 3# 3# (019000)#
    Slave Cabinet:FFl 8# 4# 5# 3# 3# (O-9000)#
    DescriptionDetermines how many red alarms occur before a Red Alarm FF key is lit.
    The FF key lights when the counter exceeds the specified number within a
    24-hour period.
    For instructions on programming 
    Tl alarm keys, see the TI Reference
    Manual (Section 500).
    Programming
    FFl 8# 4# (4 or 5)# 3# 3# (O-9000)#
    ff1
    4=Master CabinetNumber of Red Alarms that must occur
    5=Slave Cabinetwithin a 24-hour period before a
    Red Alarm FF key is lit
    Default: 9000
    Related ProgrammingRed Alarm Relay: 
    FFl 8# 4# (4 or 5)# # 2# (0 or l)#Red Alarm Detection: 
    FFl 8# 4# (4 or 5)# 2# l# (0 or l)#Red Alarm FF Key: FF5 
    (ExtPort)# (Key)# CONF (103# or 123#)#Page l-l 76
    DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Loss of Signal Counter
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 3## 4# (O-9000)#
    Slave Cabinet:FFl 8# 4# 5# 3# 4#I (0-9000)#
    DescriptionDetermines how many instances of loss of signal must occur before a Signal
    Loss Alarm FF key is lit.Signal loss occurs when the incoming 
    Tl signal is
    not received for more than 150 ms. The FF key lights when the counter
    exceeds the specified number within a 
    24-hour period.
    For instructions on programming 
    Tl alarm keys, see the TI Reference
    h4anuai (Section 500).
    Programming
    FFl 8# 4#(4 or 5)# 3# 4#(0=9llOO)#
    4=Master CabinetInstances of Signal Loss that must occur
    5=Slave Cabinetwithin a 24-hour period before a
    Signal Loss Alarm FF key is lit
    Default: 9000
    Related ProgrammingRed Alarm Relay: 
    FFl 8# 4# (4 or 5)# 4# 2# (0 or l)#Red Alarm Detection: 
    FFl 8# 4## (4 or 5)# 2# l# (0 or l)#
    DBS-70-400DBS Manual - Issued 8/l/95Page l-1 77 
    						
    							Chapter 1. System Programming (FFl)Section 400-ProgrammingSync Loss Counter
    Software Version:CPC-8 Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 3# 5# (O-9000)#
    Slave Cabinet:FFl 8# 4# 5# 3# 5# (019000)#
    DescriptionDetermines how many instances of sync loss must occur before a Sync Loss
    Alarm FF key is lit. The FF key lights when the counter exceeds the specified
    number within a 24-hour period.
    For instructions on programming 
    Tl alarm keys, see the Tl Reference
    Manual (Section 500).
    Programming
    FFl 8# 4# (4 or 5)# 3# 5# (019000)#
    f/$
    &Master CabinetInstances of Sync Loss that must occur
    5=Slave Cabinetwithin a 24hour period before a
    Sync Loss Alarm FF key is lit
    Default: 9000
    Related ProgrammingSync Loss Relay: 
    FFl 8# # (4 or 5)# 4# 3# (0 or l)#
    Page 1-178DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)Yellow Alarm Counter
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 3# 6# (O-9000)#
    Slave Cabinet:FFl 8# 4# 5# 3# 6# (0-9000)#
    DescriptionDetermines how many yellow alarms must occur before a Yellow Alarm FF
    key is lit. The FF key lights when the counter exceeds the specified number
    within a 24-hour period.
    For instructions on programming 
    Tl alarm keys, see the TI Reference
    Manual (Section 500).
    Programming
    FFl 8# 4#(4 or 5)# 3# 6#(0-9000)#
    4=Master CabinetNumber of Yellow Alarms that must
    5=Slave Cabinetoccur within a 24-hour period before
    a Yellow Alarm FF key is lit
    Default: 9000
    Related P ogrammingYellow Alarm Send: 
    FFl 8# 4# (4 or 5)# l# 7# (0-15)#Yellow Alarm Detection: 
    FFl 8# 4# (4 or 5)# 2# 2# (O-15)+/Yellow Alarm Recovery: 
    FFl 8# 4# (4 or 5)# 2# 3# (0-15)#Yellow Alar-n-t Relay: 
    FFl 8# 4## (4 or 5)# 4# l# (0-15)#Yellow Alarm FF Key: FF5 
    (ExtF’ort)# (Key)# CONF (107# or 127#)#
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-179 
    						
    							Chapter 1. System Programming (FFl )Section 400-ProgrammingYellow Alarm Relay
    Software Version: CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4## 4## 4# l# (0 or l)#
    Slave Cabinet:FFl 8# 4# 5# 4# l# (0 or l)#DescriptionDetermines whether the system closes the alarm relay on the 
    Tl MDF card in
    the event of yellow alarms.
    The alarm relay can be connected to an external alarm device such as a
    buzzer. (This device must be purchased separately; it is not provided with the
    DBS 
    Tl.)
    The Yellow Alarm Detection address (FFl 8# 4# 4/5# 2# 2# 0-15#)determines how many yellow alarms occur before the relay closes.
    Programming
    FFl 8# 4# (4 or 5)# 4# l# (0 or l)#
    f
    4=Master CabinetO=Off (Yellow Alarm relay does not close)
    5=Slave Cabinetl=On (Yellow Alarm relay closesj
    Related, ProgrammingYellow Alarm Send: 
    FFl 8# 4# (4 or 5j# l# 7# (0-15)#Yellow Alarm Detection: 
    FFl 8# 4## (4 or 5)# 2# 2# (0-15)#Yellow Alarm Recovery:FF 1 
    8# 4# (4 or 5)# 2# 3# (0- lS)#Yellow Alarm Counter: 
    FFl 8# 4#+ (4 or 5)# 3# 6# (0-15)#Yellow Alarm 
    FF Key: FF5 (ExtPort)# (Key)# CONF (107# or 127#)#
    Page l-180DBS Manual - Issued 8/l/35DES-70-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFl)
    Red Alarm Relay
    Software Version:C&-B Version 4.0 or higher.Address: Master Cabinet: 
    FFl 8## 4# 4# 4#/ 2# (0 or l)#
    Slave Cabinet:FFl 8# 4#I 5## 4## 2# (0 or l)#
    DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
    the event of red 
    alan-ns. A red alarm indicates that a loss of frame (OOF) or
    loss of signal has continued for more than 2.5 seconds.
    The alarm relay can be connected to an external alarm device such as a
    buzzer.(This device must be purchased separately; it is not provided with the
    DBS 
    Tl.)
    The Red Alarm Detection address (FFl 8# 4# 4/5# 2# l# 0-5#) determines
    how many red alarms occur before the relay closes.
    Programming
    I
    FF1 8# 4# (4 or 5)# 4# 2# (0 or I)#
    f
    I
    4=Master CabinetO=Off (Red Alarm relay does not close)
    5=Slave Cabinetl=On (Red Alarm relay closes)
    Related ProgrammingRed 
    Alarrn Detection: FFl 8# 4## 4/5# 2# l# (0-15)#Red Alarm Counter: 
    FFl 8# 4## 4/5# 3# 3# (0-9000)#
    DBS-70-400DBS Manual - Issued 8/l/95Page 1-181 
    						
    							Chapter 1. System PrOgrammIng (Wl)Sectlon 400~ProgrammingSync 
    Loss Relay
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4## 4## 4#I 3# (0 or l)#
    Slave Cabinet:FFl 8W 4# 5# 4#I 3# (0 or l)#
    DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
    the event of sync loss alarms, which result from clocking errors.
    The alarm relay can be connected to an external alarm device such as a
    buzzer.(This device must be purchased separately; it is not provided with the
    DBS Tl.)
    Programming
    FFI 8# 4# (4 or 5)# 4# 3# (0 or l)#
    f
    4=Master CabinetO=Off (Sync Loss relay does not close)
    5=Slave Cabinetl=On (Sync Loss relay closes)
    Related ProgrammingSync Loss Counter: 
    FFl 8# 4# 4/5# 3# 5# (0-9000)#
    Page 1-182DBS Manual - Issued 8/l/95DBS-IO-400 
    						
    							Section 400-ProgrammingChapter 1. System Programming (FFI )
    Frame Loss Relay
    Software Version:CPC-6 Version 4.0 or higherAddress:. Master Cabinet: 
    FFl 8# 4## 4# 4#! 4# (0 or l)#
    Slave Cabinet:FFl 8# 4## 5# 4# 4## (0 or l)#
    DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
    the event of frame loss alarms.
    The alarm relay can be connected to an external alarm device such as a
    buzzer. (This device must be purchased separately: it is not provided with the
    DBS 
    Tl.)
    Programming
    FFI 8# 4# (4 or 5)# 4# 4# (0 or l)#
    f
    I
    4=Master CabinetO=Off (Frame Loss relay does not close)
    5=Slave Cabinetl=On (Frame Loss relay closes)I
    Related ProgrammingFrame Loss Counter: 
    F?Fl 8# 4# 4/5# 3# l# (0-9000)#
    DBS-70-400DBS Manual - Issued 8/l/95Page l-l 83 
    						
    							Chapter 1. System Programming (FFl)Section 400-Programming
    AIS Relay
    Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4# 4# 5# (0 or l)#
    Slave Cabinet:FFl 8# 4# 5# 4# 5# (0 or I)#
    DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in
    the event of Alarm Indication Signals 
    (AIS), which are comprised of all l’s
    and are unframed.
    The alarm relay can be connected to an external alarm device such as a
    buzzer. (This device must be purchased separately; it is not provided with the
    DBS Tl.)
    ProgrammingI
    FFI 8# 4# (4 or 5)# 4# 5# (0 or I)#
    f
    I
    4=Master Cabinet-O=Off (AIS relay does not close)
    5=Slave Cabinetl=On (AIS relay closes)
    Related ProgrammingOther Alarms Detection: 
    FFL 8# 4## 4/5# 2# 4# (0-15)#
    Other Alarms Recovery:
    FFl 8# # 4/5# 2# 5# (0-15)#
    Page 1-l 84DBS Manual - Issued 8/l/95DBS-70-400 
    						
    							Section 400-Programming
    Chapter 1. System Programming (FFI)
    Relay Reset
    Sofhwak Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: 
    FFl 8# 4# 4## 4# 6# (0 or I)#
    Slave Cabinet:FFl 8# 4## 5## 4#/ 6# (0 or l)#
    DescriptionDetermines whether the Tl alarm relay is cleared (opened) automatically or
    manually.l
    If cleared automatically, the relay is opened approximately one second
    after the alarm condition ceases.
    lIf cleared manually, the relay can be opened by entering the Alarm Relay
    Clear code:
    -First, enter the programming authorization code --
    #98 9999
    -Then enter one of the following codes:ON/OFF 
    #94 8 (for Master Cabinet)
    ON/OFF 
    #95 8 (for Slave Cabinet)
    Programming
    II
    FFl 8# 4## (4 or 5)# 4## 6# (0 or l)#f.
    4=Master CabinetO=Automatically cleared
    5=Slave Cabinetl=Must be manually cleared
    Related ProgrammingYellow Alarm Relay: 
    FFl 8# 4#I 4/5# 4# l# (0-15)#Red Alarm Relay: 
    FFl 8# 4# 4/5# 4#+ 2# (0-15)#Sync Loss Relay: 
    FFl 8# 4# 4/5# 4# 3# (0-15)#Frame 
    LossRelay: FFl 8# 4# 4/5# 4# 4# (0-15)#
    AIS Relay: FFl 8# 4# 4/5# 4## 5# (0- 15)#
    DBS-70-400DBS Manual - Issued 8/l/95Page l-l 85 
    						