Have a look at the manual Panasonic Cpc+AII/B Digital Business System Release Notes Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Chapter 1. System Programming (FFl)Section 400-Programming Red Alarm Counter Software Version:WC-6 Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4# 3# 3# (019000)# Slave Cabinet:FFl 8# 4# 5# 3# 3# (O-9000)# DescriptionDetermines how many red alarms occur before a Red Alarm FF key is lit. The FF key lights when the counter exceeds the specified number within a 24-hour period. For instructions on programming Tl alarm keys, see the TI Reference Manual (Section 500). Programming FFl 8# 4# (4 or 5)# 3# 3# (O-9000)# ff1 4=Master CabinetNumber of Red Alarms that must occur 5=Slave Cabinetwithin a 24-hour period before a Red Alarm FF key is lit Default: 9000 Related ProgrammingRed Alarm Relay: FFl 8# 4# (4 or 5)# # 2# (0 or l)#Red Alarm Detection: FFl 8# 4# (4 or 5)# 2# l# (0 or l)#Red Alarm FF Key: FF5 (ExtPort)# (Key)# CONF (103# or 123#)#Page l-l 76 DBS Manual - Issued 8/l/95DBS-70-400
Section 400-ProgrammingChapter 1. System Programming (FFl) Loss of Signal Counter Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4# 3## 4# (O-9000)# Slave Cabinet:FFl 8# 4# 5# 3# 4#I (0-9000)# DescriptionDetermines how many instances of loss of signal must occur before a Signal Loss Alarm FF key is lit.Signal loss occurs when the incoming Tl signal is not received for more than 150 ms. The FF key lights when the counter exceeds the specified number within a 24-hour period. For instructions on programming Tl alarm keys, see the TI Reference h4anuai (Section 500). Programming FFl 8# 4#(4 or 5)# 3# 4#(0=9llOO)# 4=Master CabinetInstances of Signal Loss that must occur 5=Slave Cabinetwithin a 24-hour period before a Signal Loss Alarm FF key is lit Default: 9000 Related ProgrammingRed Alarm Relay: FFl 8# 4# (4 or 5)# 4# 2# (0 or l)#Red Alarm Detection: FFl 8# 4## (4 or 5)# 2# l# (0 or l)# DBS-70-400DBS Manual - Issued 8/l/95Page l-1 77
Chapter 1. System Programming (FFl)Section 400-ProgrammingSync Loss Counter Software Version:CPC-8 Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4# 3# 5# (O-9000)# Slave Cabinet:FFl 8# 4# 5# 3# 5# (019000)# DescriptionDetermines how many instances of sync loss must occur before a Sync Loss Alarm FF key is lit. The FF key lights when the counter exceeds the specified number within a 24-hour period. For instructions on programming Tl alarm keys, see the Tl Reference Manual (Section 500). Programming FFl 8# 4# (4 or 5)# 3# 5# (019000)# f/$ &Master CabinetInstances of Sync Loss that must occur 5=Slave Cabinetwithin a 24hour period before a Sync Loss Alarm FF key is lit Default: 9000 Related ProgrammingSync Loss Relay: FFl 8# # (4 or 5)# 4# 3# (0 or l)# Page 1-178DBS Manual - Issued 8/l/95DBS-70-400
Section 400-ProgrammingChapter 1. System Programming (FFl)Yellow Alarm Counter Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4# 3# 6# (O-9000)# Slave Cabinet:FFl 8# 4# 5# 3# 6# (0-9000)# DescriptionDetermines how many yellow alarms must occur before a Yellow Alarm FF key is lit. The FF key lights when the counter exceeds the specified number within a 24-hour period. For instructions on programming Tl alarm keys, see the TI Reference Manual (Section 500). Programming FFl 8# 4#(4 or 5)# 3# 6#(0-9000)# 4=Master CabinetNumber of Yellow Alarms that must 5=Slave Cabinetoccur within a 24-hour period before a Yellow Alarm FF key is lit Default: 9000 Related P ogrammingYellow Alarm Send: FFl 8# 4# (4 or 5)# l# 7# (0-15)#Yellow Alarm Detection: FFl 8# 4# (4 or 5)# 2# 2# (O-15)+/Yellow Alarm Recovery: FFl 8# 4# (4 or 5)# 2# 3# (0-15)#Yellow Alar-n-t Relay: FFl 8# 4## (4 or 5)# 4# l# (0-15)#Yellow Alarm FF Key: FF5 (ExtF’ort)# (Key)# CONF (107# or 127#)# DBS-70-400DBS Manual - Issued 8/l/95Page 1-179
Chapter 1. System Programming (FFl )Section 400-ProgrammingYellow Alarm Relay Software Version: CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4## 4## 4# l# (0 or l)# Slave Cabinet:FFl 8# 4# 5# 4# l# (0 or l)#DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in the event of yellow alarms. The alarm relay can be connected to an external alarm device such as a buzzer. (This device must be purchased separately; it is not provided with the DBS Tl.) The Yellow Alarm Detection address (FFl 8# 4# 4/5# 2# 2# 0-15#)determines how many yellow alarms occur before the relay closes. Programming FFl 8# 4# (4 or 5)# 4# l# (0 or l)# f 4=Master CabinetO=Off (Yellow Alarm relay does not close) 5=Slave Cabinetl=On (Yellow Alarm relay closesj Related, ProgrammingYellow Alarm Send: FFl 8# 4# (4 or 5j# l# 7# (0-15)#Yellow Alarm Detection: FFl 8# 4## (4 or 5)# 2# 2# (0-15)#Yellow Alarm Recovery:FF 1 8# 4# (4 or 5)# 2# 3# (0- lS)#Yellow Alarm Counter: FFl 8# 4#+ (4 or 5)# 3# 6# (0-15)#Yellow Alarm FF Key: FF5 (ExtPort)# (Key)# CONF (107# or 127#)# Page l-180DBS Manual - Issued 8/l/35DES-70-400
Section 400-ProgrammingChapter 1. System Programming (FFl) Red Alarm Relay Software Version:C&-B Version 4.0 or higher.Address: Master Cabinet: FFl 8## 4# 4# 4#/ 2# (0 or l)# Slave Cabinet:FFl 8# 4#I 5## 4## 2# (0 or l)# DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in the event of red alan-ns. A red alarm indicates that a loss of frame (OOF) or loss of signal has continued for more than 2.5 seconds. The alarm relay can be connected to an external alarm device such as a buzzer.(This device must be purchased separately; it is not provided with the DBS Tl.) The Red Alarm Detection address (FFl 8# 4# 4/5# 2# l# 0-5#) determines how many red alarms occur before the relay closes. Programming I FF1 8# 4# (4 or 5)# 4# 2# (0 or I)# f I 4=Master CabinetO=Off (Red Alarm relay does not close) 5=Slave Cabinetl=On (Red Alarm relay closes) Related ProgrammingRed Alarrn Detection: FFl 8# 4## 4/5# 2# l# (0-15)#Red Alarm Counter: FFl 8# 4## 4/5# 3# 3# (0-9000)# DBS-70-400DBS Manual - Issued 8/l/95Page 1-181
Chapter 1. System PrOgrammIng (Wl)Sectlon 400~ProgrammingSync Loss Relay Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4## 4## 4#I 3# (0 or l)# Slave Cabinet:FFl 8W 4# 5# 4#I 3# (0 or l)# DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in the event of sync loss alarms, which result from clocking errors. The alarm relay can be connected to an external alarm device such as a buzzer.(This device must be purchased separately; it is not provided with the DBS Tl.) Programming FFI 8# 4# (4 or 5)# 4# 3# (0 or l)# f 4=Master CabinetO=Off (Sync Loss relay does not close) 5=Slave Cabinetl=On (Sync Loss relay closes) Related ProgrammingSync Loss Counter: FFl 8# 4# 4/5# 3# 5# (0-9000)# Page 1-182DBS Manual - Issued 8/l/95DBS-IO-400
Section 400-ProgrammingChapter 1. System Programming (FFI ) Frame Loss Relay Software Version:CPC-6 Version 4.0 or higherAddress:. Master Cabinet: FFl 8# 4## 4# 4#! 4# (0 or l)# Slave Cabinet:FFl 8# 4## 5# 4# 4## (0 or l)# DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in the event of frame loss alarms. The alarm relay can be connected to an external alarm device such as a buzzer. (This device must be purchased separately: it is not provided with the DBS Tl.) Programming FFI 8# 4# (4 or 5)# 4# 4# (0 or l)# f I 4=Master CabinetO=Off (Frame Loss relay does not close) 5=Slave Cabinetl=On (Frame Loss relay closes)I Related ProgrammingFrame Loss Counter: F?Fl 8# 4# 4/5# 3# l# (0-9000)# DBS-70-400DBS Manual - Issued 8/l/95Page l-l 83
Chapter 1. System Programming (FFl)Section 400-Programming AIS Relay Software Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4# 4# 5# (0 or l)# Slave Cabinet:FFl 8# 4# 5# 4# 5# (0 or I)# DescriptionDetermines whether the system closes the alarm relay on the Tl MDF card in the event of Alarm Indication Signals (AIS), which are comprised of all l’s and are unframed. The alarm relay can be connected to an external alarm device such as a buzzer. (This device must be purchased separately; it is not provided with the DBS Tl.) ProgrammingI FFI 8# 4# (4 or 5)# 4# 5# (0 or I)# f I 4=Master Cabinet-O=Off (AIS relay does not close) 5=Slave Cabinetl=On (AIS relay closes) Related ProgrammingOther Alarms Detection: FFL 8# 4## 4/5# 2# 4# (0-15)# Other Alarms Recovery: FFl 8# # 4/5# 2# 5# (0-15)# Page 1-l 84DBS Manual - Issued 8/l/95DBS-70-400
Section 400-Programming Chapter 1. System Programming (FFI) Relay Reset Sofhwak Version:CPC-B Version 4.0 or higherAddress: Master Cabinet: FFl 8# 4# 4## 4# 6# (0 or I)# Slave Cabinet:FFl 8# 4## 5## 4#/ 6# (0 or l)# DescriptionDetermines whether the Tl alarm relay is cleared (opened) automatically or manually.l If cleared automatically, the relay is opened approximately one second after the alarm condition ceases. lIf cleared manually, the relay can be opened by entering the Alarm Relay Clear code: -First, enter the programming authorization code -- #98 9999 -Then enter one of the following codes:ON/OFF #94 8 (for Master Cabinet) ON/OFF #95 8 (for Slave Cabinet) Programming II FFl 8# 4## (4 or 5)# 4## 6# (0 or l)#f. 4=Master CabinetO=Automatically cleared 5=Slave Cabinetl=Must be manually cleared Related ProgrammingYellow Alarm Relay: FFl 8# 4#I 4/5# 4# l# (0-15)#Red Alarm Relay: FFl 8# 4# 4/5# 4#+ 2# (0-15)#Sync Loss Relay: FFl 8# 4# 4/5# 4# 3# (0-15)#Frame LossRelay: FFl 8# 4# 4/5# 4# 4# (0-15)# AIS Relay: FFl 8# 4# 4/5# 4## 5# (0- 15)# DBS-70-400DBS Manual - Issued 8/l/95Page l-l 85