Call Detail Recording (CDR) Issue 3 March 1996 3-337 1. Data is right justified and padded with blanks (spaces). 2. Data is right justified and padded with zeros. Table 3-27. CDR Data Format — 59 Character ASCII Character Position Data Field Description 01 Time-Hour (tens) 02 Time-Hour (units) 03 Time-Minute (tens) 04 Time-Minute (units) 05 Duration-Hour 06 Duration-Minute (tens) 07 Duration-Minute (units) 08 Duration-Minute (tenths) 09 Condition Code 10-12 Access Code Dialed 1 13-15 Access Code Used1 16-30 Dialed Number1 31-35 Calling Number1 36-50 Account Code1 51 FRL 52 IXC 53-55 Incoming Circuit ID 2 (tens, units, hundreds) 56-58 Outgoing Circuit ID 2 (tens, units, hundreds) 59 Carriage Return 60 Line Feed 61-63 Null
Feature Descriptions 3-338Issue 3 March 1996 Table 3-28. CDR Data Format — Printer ASCII Character Position Data Field Description 01 Time Hour- (tens) 02 Time Hour- (units) 03 Time Minute (tens) 04 Time Minute (units) 05 Space 06 Duration Hour 07 Duration Minute (tens) 08 Duration Minute (units) 09 Duration Minute (tenths) 10 Space 11 Condition Code 12 Space 13-15 Access Code Dialed 1 16 Space 17-19 Access Code Used 1 20 Space 21-35 Dialed Number 1 36 Space 37-41 Calling Number 1 42 Space 43-57 Account Code 1 58 Space 59-65 Authorization Cod e 66-69 Space 70 FRL 71 Space 72 IXC 73 Space Continued on next page
Call Detail Recording (CDR) Issue 3 March 1996 3-339 1. Data is right justified and padded with blanks (spaces). 2. Data is right justified and padded with zeros. 74-76 Incoming Circuit ID2(tens, units, hundreds) 77 Space 78-80 Outgoing Circuit ID 2(tens, units, hundreds) 81 Space 82 Feature Flag 83 Carriage Return 84 Line Feed Table 3-29. CDR Data Format — ISDN Printer ASCII Character Position Data Field Description 01 Time Hour- (tens) 02 Time Hour- (units) 03 Time Minute (tens) 04 Time Minute (units) 05 Space 06 Duration Hour 07 Duration Minute (tens) 08 Duration Minute (units) 09 Duration Minute (tenths) 10 Space 11 Condition Code 12 Space 13-15 IXC 1 Table 3-28. CDR Data Format — Printer — Continued ASCII Character Position Data Field Description Continued on next page
Feature Descriptions 3-340Issue 3 March 1996 1. Data is right justified and padded with blanks (spaces). 2. Data is right justified and padded with zeros. 16 Space 17-19 Access Code Used 1 20 Space 21-35 Dialed Number 1 36 Space 37-41 Calling Number 1 42 Space 43-57 Account Code1 58 Space 59-65 Authorization Cod e 1 66 Space 67-68 INS 1 (hundreds, tens) 69 Space 70 INS (units d i git) 71 Space 72 FRL 73 Space 74-76 Incoming Circuit ID 2 (tens, units, hundreds) 77 Space 78-80 Outgoing Circuit ID 2 (tens, units, hundreds) 81 Space 82 Feature Flag 83 Carriage Return 84 Line Feed Table 3-29. CDR Data Format — ISDN Printer — Continued ASCII Character Position Data Field Description
Call Detail Recording (CDR) Issue 3 March 1996 3-341 Table 3-30. CDR Data Format — Enhanced Printer ASCII Character Position Data Field Description 1-2 Time of Day-hours 3-4 Time of Day-minutes 5Space 6 Duration-hours 7-8 Duration-minutes 9 Duration-tenths of minutes 10 Spac e 11 Condition Code 12 Spa ce 13-16 IXC Code 1 17 Spa ce 18-21Trunk Ac cess Code Used 1 22 Spa ce 23-37 Dialed Number 1 38 Spa ce 39-43 Calling Number 1 44 Spa ce 45-59 Account Code 1 60 Spa ce 61-67 Authorization Code 1 68 Spa ce 69-71 ISDN NSV (1st and 2nd digits) 72 Spa ce 73 FRL 74 Spa ce 75-77 Incoming Circuit ID 2 (tens, units, hundreds) 78 Spa ce 79-81 Outgoing Circuit ID 2 (tens, units, hundreds) 82 Spa ce
Feature Descriptions 3-342Issue 3 March 1996 1. Data is right justified and padded with blanks (spaces). 2. Data is right justified and padded with zeros. 83 Feature Flags 84 Carriage Return 85 Line Feed Table 3-31. CDR Data Format — LSU-Expand ASCII Character Position Data Field Description 01 Time Hours (tens) 02 Time Hours (units) 03 Time Minutes (tens) 04 Time Minutes (units) 05 Space 06 Duration-Hours (units) 07 Duration-Minutes (tens) 08 Duration-Minutes (units) 09 Duration-Minutes (tenths) 10 Space 11 Condition Code 12 Space 13-15 Ac c ess Code Dialed 1 16-18 Ac c ess Code Used1 19 Space 20-34 Dialed Numb er 1 35 Space 36-39 Calling Number 1 Table 3-30. CDR Data Format — Enhanced Printer ASCII Character Position Data Field Description
Call Detail Recording (CDR) Issue 3 March 1996 3-343 1. Data is right justified and padded with blanks (spaces) 2. Data is right justified and padded with zeros. 40 Space 41-45 Ac c ount Code 1 46 Space 47-53 Authorization Code 1 54 Space 55-56 Time in Queue 1 57 Space 58 FRL 59 Space 60 Calling Number 1st digit 61 Space 62-63 Incoming Circuit ID 2 (tens, units) 64 Space 65 Feature Fla g 66 Space 67-68 Outgoing Circuit ID 2 (tens, units) 69 Space 70 Outgoing Circuit ID 2(hundreds) 71 Space 72 Incoming Circuit ID 2 (hundreds) 73 IXC 74 Carriage Return 75 Line Feed 76-78 Null Table 3-31. CDR Data Format — LSU-Expand ASCII Character Position Data Field Description
Feature Descriptions 3-344Issue 3 March 1996 1. Data is right justified and padded with blanks (spaces). 2. For a 4-digit dialing plan, this field records first four digits of calling number. 3. Data is right justified and padded with zeros. Table 3-32. CDR Data Format — LSU ASCII Character Position Data Field Description 01 Duration-Hours (units) 02 Duration-Hours (tens) 03 Duration-Minutes (units) 04 Duration-Minutes (tenths) 05 Condition Code 06-08 Access Code Dialed 1 09-11 Access Code Used1 12-26 Dialed Number1 27-30 Calling Number1, 2 (second through fifth digits for five-d igit dialing plan) 31-35 Account Code (First five Digits) 1 36-42 Authorization Code or sixth through twelfth Digits of Account Code1 43-44 Time in Queue or thirteenth and fourteenth digits of account code 1 45 FRL or fifteenth Digit of Account Code1 46 Calling Number (first digit of a five-digit calling number) 47-48 Incoming Circuit ID (tens, units) 49 Feature Flag 50-52 Outgoing Circuit ID 3 (tens, units, hundreds) 53 Incoming Circuit ID (hundreds) 54 IXC 55 Carriage Return 56 Line Feed 57-59 Null
Call Detail Recording (CDR) Issue 3 March 1996 3-345 1. Data is right justified and padded with blanks (spaces). 2. Data is right justifie d and padded with zeros. Table 3-33. CDR Data Format — ISDN LSU ASCII Character Position Data Field Description 01 Duration-Hours 02 Duration-Minutes (tens) 03 Duration-Minutes (units) 04 Duration-Minutes (tenths) 05 Condition Code 06-08 IXC 1 09-11 Access Code Used1 12-26 Dialed Number1 27-30 Calling Number1 (second through fifth digits for five-digit dialing plan) 31-35 Account Code (first five d i gits) 1 36-42 Authorization Cod e or sixth through twelfth Digits of Account Code1 43-44 INS or thirteenth and fourteenth Digits of Account Code1 45 INS (third Digit), FRL, or fifteenth Digit of Account Code1 46 Calling Number (first digit of five-digit calling number) 47-48 Incoming Circuit ID (tens, units) 49 Feature Flag 50-52 Outgoing Circuit ID 2 (tens, units, hundreds) 53 Incoming Circuit ID 2 (hund reds) 54 FRL 55 Carriage Return 56 Line Fee d 57-59 Null
Feature Descriptions 3-346Issue 3 March 1996 1. Contains the 1st 4 digits of the Callin g Number for a 4-digit dialing plan or the 2nd-5th digits for a 5-digit plan. 2. Data is right justified and padded with zeros. Table 3-34. CDR Data Format — Enhanced LSU ASCII Character Position Data Field Description 1 Duration-hours 2-3 Duration-minutes 4 Duration-tenths of minutes 5 Condition Code 6-9 IXC Code 10-12 Trunk Access Code Used 13-27 Dialed Numb er 28-31 Calling Number 1 32-35 Ac c ount Code (1st 4 digits) 36-42 Authorization Code or 6th-12th digits of Account Code 43-45 ISDN NSV 46 1st digit of a 5-digit Calling Numb er 47-48 In coming Circuit ID (tens, units) 49 Feature Flags 50-52 Outgoing Circuit ID 2 (tens, units, hundreds) 53 In coming Circuit ID 2 — 100ths digit 54 FRL 55 Carria ge Return 56 Line Feed 57 3 Null Characters (indicates end of record)