    							Call Detail Recording (CDR)
    Issue  3   March 1996
    3-337
    1. Data is right justified and padded with blanks (spaces).
    2. Data is right justified and padded with zeros.
    Table 3-27. CDR Data Format — 59 Character
    ASCII Character 
    Position Data Field Description
    01 Time-Hour (tens)
    02 Time-Hour (units)
    03 Time-Minute (tens)
    04 Time-Minute (units)
    05 Duration-Hour
    06 Duration-Minute (tens)
    07 Duration-Minute (units)
    08 Duration-Minute (tenths)
    09 Condition Code
    10-12 Access Code Dialed
    1
    13-15 Access Code Used1
    16-30 Dialed Number1
    31-35 Calling Number1
    36-50 Account Code1
    51 FRL
    52 IXC
    53-55 Incoming Circuit ID
    2 (tens, units, hundreds)
    56-58 Outgoing Circuit ID
    2 (tens, units, hundreds)
    59 Carriage Return
    60 Line Feed
    61-63 Null 
    						
    							Feature Descriptions
    3-338Issue  3   March 1996 
    Table 3-28. CDR Data Format — Printer
    ASCII Character 
    Position Data Field Description
    01 Time Hour- (tens)
    02 Time Hour- (units)
    03 Time Minute (tens)
    04 Time Minute (units)
    05 Space
    06 Duration Hour
    07 Duration Minute (tens)
    08 Duration Minute (units)
    09 Duration Minute (tenths)
    10 Space
    11 Condition Code
    12 Space
    13-15 Access Code Dialed
    1
    16 Space
    17-19 Access Code Used
    1
    20 Space
    21-35 Dialed Number
    1
    36 Space
    37-41 Calling Number
    1
    42 Space
    43-57 Account Code
    1
    58 Space
    59-65 Authorization Cod e
    66-69 Space
    70 FRL
    71 Space
    72 IXC
    73 Space
    Continued on next page 
    						
    							Call Detail Recording (CDR)
    Issue  3   March 1996
    3-339
    1. Data is right justified and padded with blanks (spaces).
    2. Data is right justified and padded with zeros.
    74-76 Incoming Circuit ID2(tens, units, hundreds)
    77 Space
    78-80 Outgoing Circuit ID
    2(tens, units, hundreds)
    81 Space
    82 Feature Flag
    83 Carriage Return
    84 Line Feed
    Table 3-29. CDR Data Format — ISDN Printer
    ASCII Character 
    Position Data Field Description
    01 Time Hour- (tens)
    02 Time Hour- (units)
    03 Time Minute (tens)
    04 Time Minute (units)
    05 Space
    06 Duration Hour
    07 Duration Minute (tens)
    08 Duration Minute (units)
    09 Duration Minute (tenths)
    10 Space
    11 Condition Code
    12 Space
    13-15 IXC
    1
    Table 3-28. CDR Data Format — Printer — Continued  
    ASCII Character 
    Position Data Field Description
    Continued on next page 
    						
    							Feature Descriptions
    3-340Issue  3   March 1996 
    1. Data is right justified and padded with blanks (spaces). 
    2. Data is right justified and padded with zeros.
    16 Space
    17-19 Access Code Used
    1
    20 Space
    21-35 Dialed Number
    1
    36 Space
    37-41 Calling Number
    1
    42 Space
    43-57 Account Code1
    58 Space
    59-65 Authorization Cod e
    1
    66 Space
    67-68 INS
    1 (hundreds, tens)
    69 Space
    70 INS (units d i git)
    71 Space
    72 FRL
    73 Space
    74-76 Incoming Circuit ID
    2 (tens, units, hundreds)
    77 Space
    78-80 Outgoing Circuit ID
    2 (tens, units, hundreds)
    81 Space
    82 Feature Flag
    83 Carriage Return
    84 Line Feed
    Table 3-29. CDR Data Format — ISDN Printer — Continued  
    ASCII Character 
    Position Data Field Description 
    						
    							Call Detail Recording (CDR)
    Issue  3   March 1996
    3-341
    Table 3-30. CDR Data Format — Enhanced Printer
    ASCII Character 
    Position Data Field Description
    1-2 Time of Day-hours
    3-4 Time of Day-minutes
    5Space
    6 Duration-hours
    7-8 Duration-minutes
    9 Duration-tenths of minutes
    10 Spac e
    11 Condition Code
    12 Spa ce
    13-16 IXC Code
    1
    17 Spa ce
    18-21Trunk Ac cess Code Used
    1
    22 Spa ce
    23-37 Dialed Number
    1
    38 Spa ce
    39-43 Calling Number
    1
    44 Spa ce
    45-59 Account Code
    1
    60 Spa ce
    61-67 Authorization Code
    1
    68 Spa ce
    69-71 ISDN NSV (1st and 2nd digits)
    72 Spa ce
    73 FRL
    74 Spa ce
    75-77 Incoming Circuit ID
    2 (tens, units, hundreds)
    78 Spa ce
    79-81 Outgoing Circuit ID
    2 (tens, units, hundreds)
    82 Spa ce 
    						
    							Feature Descriptions
    3-342Issue  3   March 1996 
    1. Data is right justified and padded with blanks (spaces).
    2. Data is right justified and padded with zeros.
    83 Feature Flags
    84 Carriage Return
    85 Line Feed
    Table 3-31. CDR Data Format — LSU-Expand
    ASCII Character 
    Position Data Field Description
    01 Time Hours (tens)
    02 Time Hours (units)
    03 Time Minutes (tens)
    04 Time Minutes (units)
    05 Space
    06 Duration-Hours (units)
    07 Duration-Minutes (tens)
    08 Duration-Minutes (units)
    09 Duration-Minutes (tenths)
    10 Space
    11 Condition Code
    12 Space
    13-15 Ac c ess Code Dialed
    1
    16-18 Ac c ess Code Used1
    19 Space
    20-34 Dialed Numb er
    1
    35 Space
    36-39 Calling Number
    1
    Table 3-30. CDR Data Format — Enhanced Printer
    ASCII Character 
    Position Data Field Description 
    						
    							Call Detail Recording (CDR)
    Issue  3   March 1996
    3-343
    1. Data is right justified and padded with blanks (spaces)
    2. Data is right justified and padded with zeros.
    40 Space
    41-45 Ac c ount Code
    1
    46 Space
    47-53 Authorization Code
    1
    54 Space
    55-56 Time in Queue
    1
    57 Space
    58 FRL
    59 Space
    60 Calling Number 1st digit
    61 Space
    62-63 Incoming Circuit ID
    2 (tens, units)
    64 Space
    65 Feature Fla g
    66 Space
    67-68 Outgoing Circuit ID
    2 (tens, units)
    69 Space
    70 Outgoing Circuit ID
    2(hundreds)
    71 Space
    72 Incoming Circuit ID
    2 (hundreds)
    73 IXC
    74 Carriage Return
    75 Line Feed
    76-78 Null
    Table 3-31. CDR Data Format — LSU-Expand
    ASCII Character 
    Position Data Field Description 
    						
    							Feature Descriptions
    3-344Issue  3   March 1996 
    1. Data is right justified and padded with blanks (spaces).
    2. For a 4-digit dialing plan, this field records first four digits of calling number.
    3. Data is right justified and padded with zeros.
    Table 3-32. CDR Data Format — LSU
    ASCII Character 
    Position Data Field Description
    01 Duration-Hours (units)
    02 Duration-Hours (tens)
    03 Duration-Minutes (units)
    04 Duration-Minutes (tenths)
    05 Condition Code
    06-08 Access Code Dialed
    1
    09-11 Access Code Used1
    12-26 Dialed Number1
    27-30 Calling Number1, 2 (second through fifth digits for 
    five-d igit dialing plan)
    31-35 Account Code (First five Digits)
    1
    36-42 Authorization Code or sixth through twelfth Digits of 
    Account Code1
    43-44 Time in Queue or thirteenth and fourteenth digits of 
    account code
    1
    45 FRL or fifteenth Digit of Account Code1
    46 Calling Number (first digit of a five-digit calling number)
    47-48 Incoming Circuit ID (tens, units)
    49 Feature Flag
    50-52 Outgoing Circuit ID
    3 (tens, units, hundreds)
    53 Incoming Circuit ID (hundreds)
    54 IXC
    55 Carriage Return
    56 Line Feed
    57-59 Null 
    						
    							Call Detail Recording (CDR)
    Issue  3   March 1996
    3-345
    1. Data is right justified and padded with blanks (spaces).
    2. Data is right justifie d and padded with zeros.
    Table 3-33. CDR Data Format — ISDN LSU
    ASCII Character 
    Position Data Field Description
    01 Duration-Hours
    02 Duration-Minutes (tens)
    03 Duration-Minutes (units)
    04 Duration-Minutes (tenths)
    05 Condition Code
    06-08 IXC
    1
    09-11 Access Code Used1
    12-26 Dialed Number1
    27-30 Calling Number1 
    (second through fifth digits for five-digit dialing  plan)
    31-35 Account Code (first five d i gits)
    1
    36-42 Authorization Cod e or sixth through twelfth Digits of 
    Account Code1
    43-44 INS or thirteenth and fourteenth Digits of Account Code1
    45 INS (third Digit), FRL, or fifteenth Digit of Account Code1
    46 Calling Number (first digit of five-digit calling number)
    47-48 Incoming Circuit ID (tens, units)
    49 Feature Flag
    50-52 Outgoing Circuit ID
    2 (tens, units, hundreds)
    53 Incoming Circuit ID
    2 (hund reds)
    54 FRL
    55 Carriage Return
    56 Line Fee d
    57-59 Null 
    						
    							Feature Descriptions
    3-346Issue  3   March 1996 
    1. Contains the 1st 4 digits of the Callin g Number for a 4-digit dialing plan or the 2nd-5th
    digits for a 5-digit plan.
    2. Data is right justified and padded with zeros.
    Table 3-34. CDR Data Format — Enhanced LSU
    ASCII Character 
    Position Data Field Description
    1 Duration-hours
    2-3 Duration-minutes
    4 Duration-tenths of minutes
    5 Condition Code
    6-9 IXC Code
    10-12 Trunk Access Code Used
    13-27 Dialed  Numb er
    28-31 Calling Number
    1
    32-35 Ac c ount Code (1st 4 digits)
    36-42 Authorization Code or 6th-12th digits of Account Code
    43-45 ISDN NSV
    46 1st digit of a 5-digit Calling Numb er
    47-48 In coming Circuit ID (tens, units)
    49 Feature Flags
    50-52 Outgoing Circuit ID
    2 (tens, units, hundreds)
    53 In coming Circuit ID
    2 — 100ths digit
    54 FRL
    55 Carria ge Return
    56 Line Feed
    57 3 Null Characters (indicates end of record) 
    						