    							System Hardware and Software Capacity Limits
    Issue  3   March 1996
    A-21
    1. The total of VDN, Station, an d Log in ID extensions cannot exceed 25,000.
    2,000 for G3rV3
    7,084 for G3rV3 for Simultaneous three-way Conf. Calls
    3,520 for G3rV3 for Simultaneous six-way Conf. Calls
    2. Simultaneous 3-way Conference Call=(483 / 3)* number PNs. Simultaneous 3-way Conference Call is
    limited by the number of Simultaneous
    3. Simultaneous 6-way Conference Call=(483 / 6)* number PNs.
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    CallVisor ASAI
    Active Station Controllin g Association NA NA/250 2,000/NA 6,000
    Call Controllers per Call NANA/1 1/NA 1
    Call Monitors per Call NA NA/14 14/NA 14
    Extension Controllers per Station Domain NA NA/2 2/NA 2
    Maximum Simultaneous Call Classifications NA NA/40 40/NA 100
    Number of ASAI Links NA NA/4 8/NA 8
    Notification Re quests
    1NA NA/50 170/NA 460
    Simultaneous Active Adjunct Controlled
    CallsNA NA/75 300/NA 3,000
    Switch to Adjunc t Associations NA NA/127 127/NA 127
    Conference Parties6666
    Simultaneous 3-way Conference Calls
    1,2161 161 483 3,542
    Simultaneous 6-way Conference Calls
    1,380 80 240 1,760
    Data Parameters
    Administered Connections NA/24 NA/24 128 128
    Permanent Switched Call NA NA NA NA
    Alphanumeric Dialing
    Ma xim um  E ntr ie s 50 50 200 1,2 50
    Cha rac te rs pe r En try 22 22 22 22
    Digital Data Endpoints75 75 800 5,000
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Dial Plan
    DID LDNs 8 8 8 20
    Extensions
    1500 500 290 0/ 35 00 21 ,87 5 
    						
    							System Parameters
    A-22Issue  3   Marc h 1996 
    1. Extensions inc lude stations, data end points, hunt groups, announcements, TEGs, VDNs, common
    shared extensions, and code calling IDs.
    2. The numbers shown in ‘‘Extension Number Portability’’ are Uniform Dialing Plan (UDP) entries.
    3. Used  for PCOL groups, c ommon shared extensions, access endpoints, administered TSCs, c ode
    calling IDs, VDNs, LDNs, hunt groups, announcements, and TEGs.
    4. The Number of Names =  number of stations +  attendant consoles +  trunk groups +  d igital data
    endpoints + miscellaneous extensions.
    Extension Number Portability2NA/240 NA/240 240 50,000
    Feature Dial Access Codes
    Numb er of Access Codes 70 70 70 70
    Numb er of Digits 1-3 1-3 1-3 1-4
    Integrated Directory Entries 204 207 1607/ 2407 10,000
    Maximum Extension Size 5 5 5 5
    Minimum Extension Size 1 1 1 1
    Miscellaneous Extensions
    3150 150 900 3317
    Names
    Number of Names
    4448/464 448/464 3,406/4,215 22,569
    Number of Characters in a Name 15 15 15 15
    Non -DID LDNs 50 50 50 66 6
    Prefix Extensions Yes Yes Yes Yes
    Trunk Dial Access Codes
    Number of Ac cess Codes 105 105 197 884
    Number of Digits 1-3 1-3 1-3/1-4 1-4
    Do Not Disturb (DND)
    DND Requests per System 200 200 1600/  2400 10,000
    Simultaneous Display Requests 10 10 10 10
    Facility Busy Indicators
    Buttons per Tracked Resource 100 100 100 100
    Num b e r o f In d i c a to rs (Sta tio n an d T ru nk
    Groups)450 450 2400/3600 2400
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1 
    						
    							System Hardware and Software Capacity Limits
    Issue  3   March 1996
    A-23
    1. One supervisor assist per split.
    2. Last Number Dialed Entries = Stations + Digital Data End p oints.
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Hunt Groups or Splits
    Announcements per Group 2 2 2 2
    Announcements per System 128 128 128 256
    Groups and/or Splits 12/24 12/24 99 255
    With Hospitality Parameter ReductionNA/5 NA/5 5 5
    Group Members per Group/Split 150 150 200 999
    Group Members per System 150 150 500 3,000
    Measured ACD Agents (Switch Limits)
    Ag ents Log g ed in per System 75 75 400 1023
    Logged-In Splits per Agent 3 3 3 3
    ACD Supervisor  Assist Per  System
    112/24 12/24 99 255
    Queue Slots per  Group 200 200 200 999
    Queue Slots per  System 200 200 1,000 10,000
    Intercom Translation Table (ICOM)
    Automatic/Manual and Dial ICOM
    Groups per System10 10 32 25 6
    Auto/Manual 16 16 32 256
    Dia l 16 16 32 25 6
    Members per ICOM group
    Aut o 32 32 32 32
    Dia l 32 32 32 32
    Members per System 320 320 1,024 8,192
    Last Number Dialed
    Entries per System
    2275 275 2,400/ 3,200 15,000
    Number of Digits 16 16 16 24
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Leave Word Calling (Switch-Based)
    1
    Messages Stored 450 450 2,000 2,000
    Messa g e s p er User 10 10 10 16 
    						
    							System Parameters
    A-24Issue  3   Marc h 1996 
    1. Leave Word Calling is available with G3s ABP only if the Voice Mail Application Sup port O ption is
    purchased.
    Remote Message Waiting Indicators
    Per Extension 80 80 80 80
    Per System 80 80 80 500
    Simultaneous Message Retrievers 60 60 60 400
    System-Wide Message Retrievers 10 10 10 10
    Malicious Call Trace
    Maximum Simultaneous Traces NA NA NA 16
    MLDN
    Via DID 8 8 8 20
    Via  CO 50 50 50 50
    Modem Pool Groups
    Mod e 2/Analog
    Group Members per System 64 64 160 2,016
    Number of Groups 2 2 5 63
    Members per Group 32 32 32 32
    Networking
    CAS Nodes NA/99 NA/99 99 99
    DCS Nodes
    BX.25 NA/20 NA/20 20 63
    ISDN PRI NA /63 NA/ 63 63 63
    Hyb rid NA/63 NA/63 63 63
    UDP Nodes NA/240 NA/240 240 999
    Paging
    Code Calling IDs 125 125 125 125
    Loudspeaker Zones 9 9 9 9
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1 
    						
    							System Hardware and Software Capacity Limits
    Issue  3   March 1996
    A-25
    1. Only port slots are included in this count. For example, there are 99 port slots per MCC EPN cabinet.
    One slot in the cabinet is already dedicated for the Tone/Clock b oard. Other service c ircuits may be
    required which would further reduce the number of port slots available. In G3 carriers, the 21st slot of
    MCC port carriers may be equip p ed  with service boards that do not require tip and ring connections.
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Partitions
    Atte n d an t P art iti on 1 1 1 1
    Extension Partition  Group 8 8 8 8
    Extension Partition 8 8 8 8
    Personal CO Lines (PCOL)
    PCOL Appearances 4 4 4 16
    PCOL Li ne s (Tru nk Gro u p s) 15 15 40 /2 00 10 0
    PCOL Trunks Per Trunk Group 1 1 1 1
    Port Circuit Pack Slots
    1
    Per Expansion Port Network (EPN)
    Multi-Carrier Cabinet (MCC) Simplex NA NA 99 99
    Multi-Carrier Cabinet (MCC) Duplex NA NA 98 98
    Single-Carrier Cabinet (SCC)
    Sim p le xNA NA 71 71
    Single-Carrier Cabinet (SCC) Duplex NA NA 70 70
    Small Cabinet Simplex
    (Upgrade only)NA NA 39 39
    Small Cabinet Duplex
    (Upgrade only)NA NA 38 38
    Per Processor Port  Network (PPN)
    Multi-Carrier Cabinet (MCC) Simplex NA NA 89 80
    Multi-Carrier Cabinet (MCC) Duplex NA NA 78 60
    Single-Carrier Cabinet (SCC)
    Sim p le xNA NA 64 NA
    Single-Carrier Cabinet (SCC) Duplex NA NA 56 NA
    Enhanced Single-Carrier Cabinet
    (ESCC) SimplexNA 70 NA NA
    Enhanced Single-Carrier Cabinet
    (ESCC) DuplexNA NA NA NA
    Compact Single-Carrier  Cabinet
    (CSCC) Simp lex10 NA NA NA 
    						
    							System Parameters
    A-26Issue  3   Marc h 1996 
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Recorded Announcements
    Analog Queue Slots per Announcement 50 50 150 300
    Analog Queue Slots per System 50 50 150 300
    Calls Connec ted per Announc ement
    Integrated Announcement or
    Auxiliary Trunk55 5255
    Ana lo g  Port s 5 5 5 12 8
    Channels per Integrated 
    Announcement Circuit Pack16 16 16 16
    Integrated Announcement Circuit Pack 1 1 1 1
    Integrated Announcement Recording
    Time (Minutes:Sec on ds)
    16 KB recording 8:32 8:32 8:32 8:32
    32 KB recording 4:16 4:16 4:16 4:16
    Integrated Queue Slots per System 50 50 50 300
    Re c ord e d  An no un c e men ts 128 128 128 25 6
    System Administration
    Administrable History File Entries 50 50 250 1,250
    Simultaneous Administration Command 1 1 1 5
    Simultaneous Maintenan ce Command 1 1 1 3
    Simultaneous SM Sessions 3 3 5 8
    Printer Queue Size 50 50 50 50
    Speech Synthesis Circuit Packs66 66
    Channels per Speech Circuit Pack 4 4 4 4 
    						
    							System Hardware and Software Capacity Limits
    Issue  3   March 1996
    A-27
    1. 24 1 Sim ul ta ne ou s C irc uit -Swi tch e d  Cal ls p e r p o rt network, except for G3s, where the maximum is 180.
    2. 512 time slots per port network.
    3. 483 time slots for Voice and Data p er port network. Even though an EPN is supported in G3sV2, giving
    a total of two port networks, G3sV2 is d esigned to support only 180 Simultaneous Circuit-S wit c h e d
    Calls.
    4. Only one PI board is supported in G3vs/G3s (both MCC and SCC), and therefore a total of four physical
    links, used for BX.25 or PRI, are available.
    In G3i, two PI boards can be supported in the MCC, and therefore a total of eight physical links (used
    for BX25 or PRI) are availa ble. Sin ce the SCC c an only supp ort one PI b oard, a total of four physical
    links (used for BX25 or PRI) are available in the SCC 286 an d Me dium config urations.
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Terminating Extension Groups (TEG)
    TEGs 32 32 32 32
    Users That May Share a TEG 4 4 4 4
    Time Slots
    Simultaneous Circuit Switched Calls
    1180 180 723 5,302
    Total Slots
    2512 512 15 36 11 ,26 4
    Time Slots for Voice and Data
    3483 483 14 49 10 ,60 4
    Time Slots per Port Network 512 512 512 512
    Tone Classifiers
    Call Classifier Boards NA/10 NA/10 10 50
    Call Progress/Touch Tone Receivers NA/80 NA/80 80 400
    Tone Detector Boards 10 20 20 50
    General Purpose Tone Detectors 20 40 40 100
    Touch-Tone Receivers 40 80 80 200
    Prompting TTR Queue Size NA NA 80 80
    TTR Queue Size 4 4 4 4
    Trunks
    DS1 Circuit Packs 8 8 30 166
    Queue Slots for Trunks 32/64 32/64 198 1,332
    PRI Interfaces via PI
    4NA/4 NA/4 8 NA
    PRI Interfaces via PKTINT NA/4 NA/4 NA/8 166 
    						
    							System Parameters
    A-28Issue  3   Marc h 1996 
    1. G3vs has the same software capacities for stations and trunks as G3s.  However, these software
    capacities are limited  by the cabinet hardware. A typical switch may have 20 to 50 stations with 10 to
    20 trunks. Station c apacities can be reached only by administration without hardware (AWOH). This
    includes extensions administered without hardware.
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Trunks (Continued)
    PRI Temporary Sig naling Connections
    TSCs in System NA/164 NA/164 656 4,256
    Call Associated TSCs NA/100 NA/100 400 4,000
    Non Call Associated  TSCs NA/64 NA/64 256 256
    Administered TSCs NA/32 NA/32 128 128
    Ringback Queue Slots 120 120 120 1,332
    Total PRI Interfaces (30) NA/4 NA/4 8 166
    Trunk Groups Hourly Measurements NA NA NA 75
    Trunk Groups in the System 16/32 16/32 99 666
    Trunk Memb ers in a Trunk Group 50/99 50/99 99 255
    Trunks in System (Including Remote
    Access)
    150/100 50/100 400 4,000
    With Hospitality Parameter
    ReductionNA/NA NA/NA 50 50
    Measured Trunks in System 50/100 50/100 400 2000 
    						
    							System Hardware and Software Capacity Limits
    Issue  3   March 1996
    A-29
    1. All BRI stations can be disp lay stations.
    2. In G3, ‘‘Station Button Capacity (units) ‘replaces’ Maximum Button Modules.’’
    The following examples show how these units can b e used. The assumption is that only three call
    appearances are assigned to the sets (except analog sets which have no call appearance).
    — Analog sets (for example, 7104A): G3r, 76 units; all other releases, 62 units.
    — Digital sets with 10 buttons (for example, 7403D): G3r, 124 units; all other releases, 102 
    units.
    — Digital sets with 34 buttons, without disp lay (for example, 7405D): G3r, 412 units; all other 
    releases, 342 units.
    — Digital sets with 34 buttons, with display (for example, 7405D): G3r, 568 units; all other 
    releases, 472 units.
    — 7406D Digital sets with display: G3r, 412 units; all other releases, 342 units.
    BRI sets wi th 17  bu ttons, with disp lay (for example, 7506D): G3r, 304 units; all other releases, 250
    units.The station button cap ac ity c an support all stations equip ped as 7406D digital sets with display. For
    examp le, a total of 342* 1200 + 410.4K units for the G3iV 1. 1-2 86 .
    Table A-1. Maximum System Parameters for G3V1 — continued
    ITEMG3vsV1 
    ABP/PBPG3sV1 
    ABP/PBPG3iV1/ 
    G3i-Global G3rV1
    Voice Terminals
    Associated Data Modules (such as
    DTDM s)75 75 800 5,00 0
    BRI Stations
    1NA 50 1,000 5,000
    Digital Stations 200 200 1,600 10,000
    Stations 200 200 1,600 10,000
    Station Button Capacity (K Units)
    2102.6 102.6 547.2 4120 
    						
    							System Parameters
    A-30Issue  3   Marc h 1996 
    1. 100,000 for G3rV3
    2. In the case of Single-Carrier Cabinets (SCC), only four BX.25 physical links are sup ported in G3sV2 and
    G3iV2.
    Table A-2. Maximum System Parameters for G3V1.1 or V2
    ITEMG3iV1.1-
    286G3vsV2 
    ABP/PBPG3sV2 
    ABP/PBPG3iV2-
    386 G3rV2
    Abbreviated Dialing (AD)
    AD Lists Per System 1,600 200 200 2,400 5,000
    AD List Entry Size 24 24 24 24 24
    AD Entries Per System
    110,000 2,000 2,000 12,000 50,000
    Enhanc ed List (System List) 1 NA/1 NA/1 1 1
    Maximum Entries 1,000 NA/1,000 NA/1,000 1,000 1,000
    Group Lists 100 100 100 100 1,000
    Maximum Entries 90 90 90 90 90
    Group Lists per Extension 3 3 3 3 3
    System List 11 111
    Maximum Entries 90 90 90 90 90
    Personal Lists 1,600 200 200 2,400 5,000
    Maximum Entries 10 10 10 10 10
    Personal Lists per Extension 3 3 3 3 3
    Applications Adjuncts
    CallVisor ASAI Adjuncts 8 NA/NA NA/4 8 8
    Asynchronous Links (RS-232) 5 5 5 5 10
    CDR Output Devices 2 2 2 2 2
    Journal:System Printer 2:1 2:1 2:1 2:1 2:1
    Property Management Systems 1 1 1 1 1
    BX.25 Physical Links
    284 4816
    Application Processors (such as
    3B2-MCS)11 117
    AUDIX Adjunc ts 1 1 1 1 8
    CMS Adjuncts 11 111
    CM Adjuncts
    ISDN Gateway 1 NA/1 NA/1 1 1
    BX.25 Processor Channels 64 64 64 64 128
    Hop Channels 6464 6464128 
    						