System Hardware and Software Capacity Limits Issue 3 March 1996 A-21 1. The total of VDN, Station, an d Log in ID extensions cannot exceed 25,000. 2,000 for G3rV3 7,084 for G3rV3 for Simultaneous three-way Conf. Calls 3,520 for G3rV3 for Simultaneous six-way Conf. Calls 2. Simultaneous 3-way Conference Call=(483 / 3)* number PNs. Simultaneous 3-way Conference Call is limited by the number of Simultaneous 3. Simultaneous 6-way Conference Call=(483 / 6)* number PNs. Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 CallVisor ASAI Active Station Controllin g Association NA NA/250 2,000/NA 6,000 Call Controllers per Call NANA/1 1/NA 1 Call Monitors per Call NA NA/14 14/NA 14 Extension Controllers per Station Domain NA NA/2 2/NA 2 Maximum Simultaneous Call Classifications NA NA/40 40/NA 100 Number of ASAI Links NA NA/4 8/NA 8 Notification Re quests 1NA NA/50 170/NA 460 Simultaneous Active Adjunct Controlled CallsNA NA/75 300/NA 3,000 Switch to Adjunc t Associations NA NA/127 127/NA 127 Conference Parties6666 Simultaneous 3-way Conference Calls 1,2161 161 483 3,542 Simultaneous 6-way Conference Calls 1,380 80 240 1,760 Data Parameters Administered Connections NA/24 NA/24 128 128 Permanent Switched Call NA NA NA NA Alphanumeric Dialing Ma xim um E ntr ie s 50 50 200 1,2 50 Cha rac te rs pe r En try 22 22 22 22 Digital Data Endpoints75 75 800 5,000 Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Dial Plan DID LDNs 8 8 8 20 Extensions 1500 500 290 0/ 35 00 21 ,87 5
System Parameters A-22Issue 3 Marc h 1996 1. Extensions inc lude stations, data end points, hunt groups, announcements, TEGs, VDNs, common shared extensions, and code calling IDs. 2. The numbers shown in ‘‘Extension Number Portability’’ are Uniform Dialing Plan (UDP) entries. 3. Used for PCOL groups, c ommon shared extensions, access endpoints, administered TSCs, c ode calling IDs, VDNs, LDNs, hunt groups, announcements, and TEGs. 4. The Number of Names = number of stations + attendant consoles + trunk groups + d igital data endpoints + miscellaneous extensions. Extension Number Portability2NA/240 NA/240 240 50,000 Feature Dial Access Codes Numb er of Access Codes 70 70 70 70 Numb er of Digits 1-3 1-3 1-3 1-4 Integrated Directory Entries 204 207 1607/ 2407 10,000 Maximum Extension Size 5 5 5 5 Minimum Extension Size 1 1 1 1 Miscellaneous Extensions 3150 150 900 3317 Names Number of Names 4448/464 448/464 3,406/4,215 22,569 Number of Characters in a Name 15 15 15 15 Non -DID LDNs 50 50 50 66 6 Prefix Extensions Yes Yes Yes Yes Trunk Dial Access Codes Number of Ac cess Codes 105 105 197 884 Number of Digits 1-3 1-3 1-3/1-4 1-4 Do Not Disturb (DND) DND Requests per System 200 200 1600/ 2400 10,000 Simultaneous Display Requests 10 10 10 10 Facility Busy Indicators Buttons per Tracked Resource 100 100 100 100 Num b e r o f In d i c a to rs (Sta tio n an d T ru nk Groups)450 450 2400/3600 2400 Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1
System Hardware and Software Capacity Limits Issue 3 March 1996 A-23 1. One supervisor assist per split. 2. Last Number Dialed Entries = Stations + Digital Data End p oints. Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Hunt Groups or Splits Announcements per Group 2 2 2 2 Announcements per System 128 128 128 256 Groups and/or Splits 12/24 12/24 99 255 With Hospitality Parameter ReductionNA/5 NA/5 5 5 Group Members per Group/Split 150 150 200 999 Group Members per System 150 150 500 3,000 Measured ACD Agents (Switch Limits) Ag ents Log g ed in per System 75 75 400 1023 Logged-In Splits per Agent 3 3 3 3 ACD Supervisor Assist Per System 112/24 12/24 99 255 Queue Slots per Group 200 200 200 999 Queue Slots per System 200 200 1,000 10,000 Intercom Translation Table (ICOM) Automatic/Manual and Dial ICOM Groups per System10 10 32 25 6 Auto/Manual 16 16 32 256 Dia l 16 16 32 25 6 Members per ICOM group Aut o 32 32 32 32 Dia l 32 32 32 32 Members per System 320 320 1,024 8,192 Last Number Dialed Entries per System 2275 275 2,400/ 3,200 15,000 Number of Digits 16 16 16 24 Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Leave Word Calling (Switch-Based) 1 Messages Stored 450 450 2,000 2,000 Messa g e s p er User 10 10 10 16
System Parameters A-24Issue 3 Marc h 1996 1. Leave Word Calling is available with G3s ABP only if the Voice Mail Application Sup port O ption is purchased. Remote Message Waiting Indicators Per Extension 80 80 80 80 Per System 80 80 80 500 Simultaneous Message Retrievers 60 60 60 400 System-Wide Message Retrievers 10 10 10 10 Malicious Call Trace Maximum Simultaneous Traces NA NA NA 16 MLDN Via DID 8 8 8 20 Via CO 50 50 50 50 Modem Pool Groups Mod e 2/Analog Group Members per System 64 64 160 2,016 Number of Groups 2 2 5 63 Members per Group 32 32 32 32 Networking CAS Nodes NA/99 NA/99 99 99 DCS Nodes BX.25 NA/20 NA/20 20 63 ISDN PRI NA /63 NA/ 63 63 63 Hyb rid NA/63 NA/63 63 63 UDP Nodes NA/240 NA/240 240 999 Paging Code Calling IDs 125 125 125 125 Loudspeaker Zones 9 9 9 9 Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1
System Hardware and Software Capacity Limits Issue 3 March 1996 A-25 1. Only port slots are included in this count. For example, there are 99 port slots per MCC EPN cabinet. One slot in the cabinet is already dedicated for the Tone/Clock b oard. Other service c ircuits may be required which would further reduce the number of port slots available. In G3 carriers, the 21st slot of MCC port carriers may be equip p ed with service boards that do not require tip and ring connections. Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Partitions Atte n d an t P art iti on 1 1 1 1 Extension Partition Group 8 8 8 8 Extension Partition 8 8 8 8 Personal CO Lines (PCOL) PCOL Appearances 4 4 4 16 PCOL Li ne s (Tru nk Gro u p s) 15 15 40 /2 00 10 0 PCOL Trunks Per Trunk Group 1 1 1 1 Port Circuit Pack Slots 1 Per Expansion Port Network (EPN) Multi-Carrier Cabinet (MCC) Simplex NA NA 99 99 Multi-Carrier Cabinet (MCC) Duplex NA NA 98 98 Single-Carrier Cabinet (SCC) Sim p le xNA NA 71 71 Single-Carrier Cabinet (SCC) Duplex NA NA 70 70 Small Cabinet Simplex (Upgrade only)NA NA 39 39 Small Cabinet Duplex (Upgrade only)NA NA 38 38 Per Processor Port Network (PPN) Multi-Carrier Cabinet (MCC) Simplex NA NA 89 80 Multi-Carrier Cabinet (MCC) Duplex NA NA 78 60 Single-Carrier Cabinet (SCC) Sim p le xNA NA 64 NA Single-Carrier Cabinet (SCC) Duplex NA NA 56 NA Enhanced Single-Carrier Cabinet (ESCC) SimplexNA 70 NA NA Enhanced Single-Carrier Cabinet (ESCC) DuplexNA NA NA NA Compact Single-Carrier Cabinet (CSCC) Simp lex10 NA NA NA
System Parameters A-26Issue 3 Marc h 1996 Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Recorded Announcements Analog Queue Slots per Announcement 50 50 150 300 Analog Queue Slots per System 50 50 150 300 Calls Connec ted per Announc ement Integrated Announcement or Auxiliary Trunk55 5255 Ana lo g Port s 5 5 5 12 8 Channels per Integrated Announcement Circuit Pack16 16 16 16 Integrated Announcement Circuit Pack 1 1 1 1 Integrated Announcement Recording Time (Minutes:Sec on ds) 16 KB recording 8:32 8:32 8:32 8:32 32 KB recording 4:16 4:16 4:16 4:16 Integrated Queue Slots per System 50 50 50 300 Re c ord e d An no un c e men ts 128 128 128 25 6 System Administration Administrable History File Entries 50 50 250 1,250 Simultaneous Administration Command 1 1 1 5 Simultaneous Maintenan ce Command 1 1 1 3 Simultaneous SM Sessions 3 3 5 8 Printer Queue Size 50 50 50 50 Speech Synthesis Circuit Packs66 66 Channels per Speech Circuit Pack 4 4 4 4
System Hardware and Software Capacity Limits Issue 3 March 1996 A-27 1. 24 1 Sim ul ta ne ou s C irc uit -Swi tch e d Cal ls p e r p o rt network, except for G3s, where the maximum is 180. 2. 512 time slots per port network. 3. 483 time slots for Voice and Data p er port network. Even though an EPN is supported in G3sV2, giving a total of two port networks, G3sV2 is d esigned to support only 180 Simultaneous Circuit-S wit c h e d Calls. 4. Only one PI board is supported in G3vs/G3s (both MCC and SCC), and therefore a total of four physical links, used for BX.25 or PRI, are available. In G3i, two PI boards can be supported in the MCC, and therefore a total of eight physical links (used for BX25 or PRI) are availa ble. Sin ce the SCC c an only supp ort one PI b oard, a total of four physical links (used for BX25 or PRI) are available in the SCC 286 an d Me dium config urations. Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Terminating Extension Groups (TEG) TEGs 32 32 32 32 Users That May Share a TEG 4 4 4 4 Time Slots Simultaneous Circuit Switched Calls 1180 180 723 5,302 Total Slots 2512 512 15 36 11 ,26 4 Time Slots for Voice and Data 3483 483 14 49 10 ,60 4 Time Slots per Port Network 512 512 512 512 Tone Classifiers Call Classifier Boards NA/10 NA/10 10 50 Call Progress/Touch Tone Receivers NA/80 NA/80 80 400 Tone Detector Boards 10 20 20 50 General Purpose Tone Detectors 20 40 40 100 Touch-Tone Receivers 40 80 80 200 Prompting TTR Queue Size NA NA 80 80 TTR Queue Size 4 4 4 4 Trunks DS1 Circuit Packs 8 8 30 166 Queue Slots for Trunks 32/64 32/64 198 1,332 PRI Interfaces via PI 4NA/4 NA/4 8 NA PRI Interfaces via PKTINT NA/4 NA/4 NA/8 166
System Parameters A-28Issue 3 Marc h 1996 1. G3vs has the same software capacities for stations and trunks as G3s. However, these software capacities are limited by the cabinet hardware. A typical switch may have 20 to 50 stations with 10 to 20 trunks. Station c apacities can be reached only by administration without hardware (AWOH). This includes extensions administered without hardware. Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Trunks (Continued) PRI Temporary Sig naling Connections TSCs in System NA/164 NA/164 656 4,256 Call Associated TSCs NA/100 NA/100 400 4,000 Non Call Associated TSCs NA/64 NA/64 256 256 Administered TSCs NA/32 NA/32 128 128 Ringback Queue Slots 120 120 120 1,332 Total PRI Interfaces (30) NA/4 NA/4 8 166 Trunk Groups Hourly Measurements NA NA NA 75 Trunk Groups in the System 16/32 16/32 99 666 Trunk Memb ers in a Trunk Group 50/99 50/99 99 255 Trunks in System (Including Remote Access) 150/100 50/100 400 4,000 With Hospitality Parameter ReductionNA/NA NA/NA 50 50 Measured Trunks in System 50/100 50/100 400 2000
System Hardware and Software Capacity Limits Issue 3 March 1996 A-29 1. All BRI stations can be disp lay stations. 2. In G3, ‘‘Station Button Capacity (units) ‘replaces’ Maximum Button Modules.’’ The following examples show how these units can b e used. The assumption is that only three call appearances are assigned to the sets (except analog sets which have no call appearance). — Analog sets (for example, 7104A): G3r, 76 units; all other releases, 62 units. — Digital sets with 10 buttons (for example, 7403D): G3r, 124 units; all other releases, 102 units. — Digital sets with 34 buttons, without disp lay (for example, 7405D): G3r, 412 units; all other releases, 342 units. — Digital sets with 34 buttons, with display (for example, 7405D): G3r, 568 units; all other releases, 472 units. — 7406D Digital sets with display: G3r, 412 units; all other releases, 342 units. BRI sets wi th 17 bu ttons, with disp lay (for example, 7506D): G3r, 304 units; all other releases, 250 units.The station button cap ac ity c an support all stations equip ped as 7406D digital sets with display. For examp le, a total of 342* 1200 + 410.4K units for the G3iV 1. 1-2 86 . Table A-1. Maximum System Parameters for G3V1 — continued ITEMG3vsV1 ABP/PBPG3sV1 ABP/PBPG3iV1/ G3i-Global G3rV1 Voice Terminals Associated Data Modules (such as DTDM s)75 75 800 5,00 0 BRI Stations 1NA 50 1,000 5,000 Digital Stations 200 200 1,600 10,000 Stations 200 200 1,600 10,000 Station Button Capacity (K Units) 2102.6 102.6 547.2 4120
System Parameters A-30Issue 3 Marc h 1996 1. 100,000 for G3rV3 2. In the case of Single-Carrier Cabinets (SCC), only four BX.25 physical links are sup ported in G3sV2 and G3iV2. Table A-2. Maximum System Parameters for G3V1.1 or V2 ITEMG3iV1.1- 286G3vsV2 ABP/PBPG3sV2 ABP/PBPG3iV2- 386 G3rV2 Abbreviated Dialing (AD) AD Lists Per System 1,600 200 200 2,400 5,000 AD List Entry Size 24 24 24 24 24 AD Entries Per System 110,000 2,000 2,000 12,000 50,000 Enhanc ed List (System List) 1 NA/1 NA/1 1 1 Maximum Entries 1,000 NA/1,000 NA/1,000 1,000 1,000 Group Lists 100 100 100 100 1,000 Maximum Entries 90 90 90 90 90 Group Lists per Extension 3 3 3 3 3 System List 11 111 Maximum Entries 90 90 90 90 90 Personal Lists 1,600 200 200 2,400 5,000 Maximum Entries 10 10 10 10 10 Personal Lists per Extension 3 3 3 3 3 Applications Adjuncts CallVisor ASAI Adjuncts 8 NA/NA NA/4 8 8 Asynchronous Links (RS-232) 5 5 5 5 10 CDR Output Devices 2 2 2 2 2 Journal:System Printer 2:1 2:1 2:1 2:1 2:1 Property Management Systems 1 1 1 1 1 BX.25 Physical Links 284 4816 Application Processors (such as 3B2-MCS)11 117 AUDIX Adjunc ts 1 1 1 1 8 CMS Adjuncts 11 111 CM Adjuncts ISDN Gateway 1 NA/1 NA/1 1 1 BX.25 Processor Channels 64 64 64 64 128 Hop Channels 6464 6464128