Sharp Mx 4100n Owners Manual
Have a look at the manual Sharp Mx 4100n Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 615 Sharp manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2-110 COPIER Contents 2 * The size that is twice A0 size. Set the enlargement size and the original size. (1) Select the size system that you wish to use for multi-page enlargement. Touch the keys to display the screen that shows the desired group of sizes. 1st screen: Inch system 2nd screen: A system 3rd screen: B system (2) Select the enlargement size. (3) Select the size of the original to be used. A suitable original placement orientation (A) and the number of sheets of paper required for the enlarged image (B) are displayed based on the selected original size and enlargement size. Check the placement orientation and number of sheets. The combinations of original sizes and enlargement sizes shown in the table at left are possible for multi-page enlargement. An A size original cannot be enlarged to a B size, and a B size original cannot be enlarged to an A size. To print a borderline around the copy image, touch the [Border Print] key so that it is highlighted. 3 Place the original face down on the document glass in the orientation indicated in the screen. Ready to scan for copy. Copies will be delivered in 2 parts. OK OKCancelBorder Print Image Edit Multi-Page Enlargement 22x17 8½x1422x34 34x44 44x68 11x17 8½x11 Enlargement Size (Inch)Original SizeOriginal Orientation13 (2)(A)(1)(3) (B) 22 x 17 11 x 17, 8-1/2 x 14, 8-1/2 x 11 22 x 34 11 x 17, 8-1/2 x 14, 8-1/2 x 11 34 x 44 11 x 17, 8-1/2 x 14, 8-1/2 x 11 44 x 68 11 x 17 A2 A3, A4, A5 A1 A3, A4, A5 A0 A3, A4 A0 x 2* A3 B3 B4, B5 B2 B4, B5 B1 B4, B5 B0 B4 Enlargement size Original sizeInch system B system A system
2-111 COPIER Contents 4 Touch the [OK] key. You will return to the special modes screen. Touch the [OK] key to return to the base screen of copy mode. 5 Press the [COLOR START] key or the [BLACK & WHITE START] key. Copying will begin. If you have selected sort mode, change originals and press the [START] key. Repeat until all pages have been scanned and then touch the [Read-End] key. (For the second original and following originals, use the same [START] key as you did for the first original. To cancel scanning and copying... Press the [STOP] key ( ). The original must be placed on the document glass. Overlap of sections of image - There will be a margin around the edges of each copy. - Areas for overlapping the copies will be created at the leading and trailing edges of each copy. If an original size is selected first, a message will appear indicating the enlargement sizes that can be selected. If an enlargement size is selected first, a message will appear indicating the original sizes that can be selected. If a combination of settings is selected for which multi-page enlargement is not possible, invalid selection beeps will sound. The paper size, number of sheets required for the enlarged image, and the ratio are automatically selected based on the selected original size and enlargement size. (The paper size and ratio cannot be selected manually.) If no paper trays have the size of paper that was automatically selected, Load XXX paper will appear. Change the paper in one of the trays or the bypass tray to the indicated size of paper. To cancel the multi-page enlargement setting... Touch the [Cancel] key in the screen of step 2. Although the multi-page enlargement setting is canceled, the ratio selected automatically is kept valid. To return the ratio to 100%... To return the ratio setting to 100%, touch the [Copy Ratio] key to display the ratio menu and then touch the [100%] key. Original Orientation OK OKCancelBorder Print Image Edit Multi-Page Enlargement Original Size1322x17 8½x1422x34 34x44 44x68 11x17 8½x11 Enlargement Size (Inch)
2-112 COPIER Contents REVERSING THE IMAGE (Mirror Image) This feature is used to make a copy that is a mirror image of the original. 1 Place the original. Place the original face up in the document feeder tray, or face down on the document glass. 2 Select the special modes. (1) Touch the [Special Modes] key. (2) Touch the keys to switch through the screens. (3) Touch the [Image Edit] key. ☞[Image Edit] KEY (page 2-106) 3 Select Mirror Image. (1) Touch the [Mirror Image] key so that it is highlighted. (2) Touch the [OK] key. You will return to the special modes screen. Touch the [OK] key to return to the base screen of copy mode. 4 Press the [COLOR START] key or the [BLACK & WHITE START] key. Copying will begin. If you are using the document glass to copy multiple original pages, copying will take place as you scan each original. If you have selected sort mode, change originals and press the [START] key. Repeat until all pages have been scanned and then touch the [Read-End] key. (For the second original and following originals, use the same [START] key as you did for the first original. To cancel scanning and copying... Press the [STOP] key ( ). To cancel a mirror image setting... Touch the [Mirror Image] key in the screen of step 3 so that it is not highlighted. Original Mirror image copy OK Mirror Image B/W Reverse Multi-Page Enlargement Centering11x17 Full Bleed Photo Repeat OKSpecial Modes Image Edit (1)(2)
2-113 COPIER Contents COPYING 11 x 17 ORIGINALS WITH NO EDGE CUT-OFF (11 x 17 Full Bleed) This feature lets you copy an entire 11 x 17 (A3) size original at full size with no image cut-off at the edges. 12 x 18 (A3W) size paper is used, which is slightly larger than 11 x 17 (A3) size. 1 Place the original face down on the document glass. 2 Select the special modes. (1) Touch the [Special Modes] key. (2) Touch the keys to switch through the screens. (3) Touch the [Image Edit] key. ☞[Image Edit] KEY (page 2-106) 3 Select 11x17 Full Bleed. (1) Touch the [11x17 Full Bleed] key so that it is highlighted. (2) Touch the [OK] key. You will return to the special modes screen. Touch the [OK] key to return to the base screen of copy mode. 11 x 17 (A3) size original12 x 18 (A3W) full bleed copy OK Mirror Image B/W Reverse Multi-Page Enlargement Centering11x17 Full Bleed Photo Repeat Special Modes Image Edit OK (1)(2)
2-114 COPIER Contents 4 Place 12 x 18 (A3W) paper in the bypass tray. Pull out the extension tray, adjust the guides to the width of 12 x 18 (A3W) paper, and place the paper in the bypass tray. After loading the paper, configure the bypass tray settings as explained in MAKING COPIES USING THE BYPASS TRAY (page 2-40). 5 Press the [COLOR START] key or the [BLACK & WHITE START] key. Copying will begin. If you have selected sort mode, change originals and press the [START] key. Repeat until all pages have been scanned and then touch the [Read-End] key. (For the second original and following originals, use the same [START] key as you did for the first original.) To cancel scanning and copying... Press the [STOP] key ( ). The original must be placed on the document glass. The copy ratio is 100% when this function is used. The ratio cannot be changed. The staple, paper folding, and punch function cannot be used. To cancel 11x17 Full Bleed... Touch the [11x17 Full Bleed] key in the screen of step 3 so that it is not highlighted.
2-115 COPIER Contents COPYING IN THE CENTER OF THE PAPER (Centering) This is used to center the copied image on the paper. This lets you place the image in the center of the paper when the original size is smaller than the paper size or when the image is reduced. Not using the centering functionUsing the centering function 1 Place the original. Place the original face up in the document feeder tray, or face down on the document glass. 2 Select the special modes. (1) Touch the [Special Modes] key. (2) Touch the keys to switch through the screens. (3) Touch the [Image Edit] key. ☞[Image Edit] KEY (page 2-106) 3 Select Centering. (1) Touch the [Centering] key so that it is highlighted. (2) Touch the [OK] key. You will return to the special modes screen. Touch the [OK] key to return to the base screen of copy mode. 4 Press the [COLOR START] key or the [BLACK & WHITE START] key. Copying will begin. If you are using the document glass to copy multiple original pages, copying will take place as you scan each original. If you have selected sort mode, change originals and press the [START] key. Repeat until all pages have been scanned and then touch the [Read-End] key. (For the second original and following originals, use the same [START] key as you did for the first original. To cancel scanning and copying... Press the [STOP] key ( ). OK Mirror Image B/W Reverse Multi-Page Enlargement Centering Photo Repeat Special Modes Image Edit 11x17 Full Bleed OK (1)(2)
2-116 COPIER Contents The image can be reduced when using the centering function, but not enlarged. When the original size or the paper size is displayed as a special size, this function cannot be used. To cancel centering... Touch the [Centering] key in the screen of step 3 so that it is not highlighted.
2-117 COPIER Contents REVERSING WHITE AND BLACK IN A COPY (B/W Reverse) This is used to reverse black and white in a copy to create a negative image. This function can only be used for black and white copying. Originals with large black areas (which use a large amount of toner) can be copied using Black/White Reverse to reduce toner consumption. 1 Place the original. Place the original face up in the document feeder tray, or face down on the document glass. 2 Select the special modes. (1) Touch the [Special Modes] key. (2) Touch the keys to switch through the screens. (3) Touch the [Image Edit] key. ☞[Image Edit] KEY (page 2-106) 3 Select B/W Reverse. (1) Touch the [B/W Reverse] key so that it is highlighted. (2) Touch the [OK] key. You will return to the special modes screen. Touch the [OK] key to return to the base screen of copy mode. 4 Press the [BLACK & WHITE START] key. Copying will begin. If you are using the document glass to copy multiple original pages, copying will take place as you scan each original. If you have selected sort mode, change originals and press the [BLACK & WHITE START] key. Repeat until all pages have been scanned and then touch the [Read-End] key. When using this function, the [COLOR START] key cannot be used. To cancel scanning and copying... Press the [STOP] key ( ). Originals B/W Reverse copy 11x17 Full Bleed OK Mirror Image B/W Reverse Multi-Page Enlargement Centering Photo Repeat Special Modes Image Edit OK (1)(2)
2-118 COPIER Contents When this function is selected, the Original Image Type setting for exposure adjustment automatically changes to Text. To cancel B/W reverse... Touch the [B/W Reverse] key in the screen of step 3 so that it is not highlighted.
2-119 COPIER Contents [Color Adjustments] KEY When the [Color Adjustments] key is touched in the 2nd special modes menu screen, the color adjustments menu screen opens. Color adjustments menu screen (1) [RGB Adjust] key ☞ADJUSTING RED/GREEN/BLUE IN COPIES (RGB Adjust) (page 2-120) (2) [Sharpness] key ☞ADJUSTING THE SHARPNESS OF AN IMAGE (Sharpness) (page 2-121) (3) [Suppress background] key ☞WHITENING FAINT COLORS IN COPIES (Suppress Background) (page 2-122)(4) [Color Balance] key ☞ADJUSTING THE COLOR (Color Balance) (page 2-124) (5) [Brightness] key ☞ADJUSTING THE BRIGHTNESS OF A COPY (Brightness) (page 2-126) (6) [Intensity] key ☞ADJUSTING THE INTENSITY OF A COPY (Intensity) (page 2-127) OK Suppress Background Intensity Sharpness BrightnessColor Balance RGB Adjust OKSpecial Modes Color Adjustments Special Modes 22 OK Image Edit Quick FileProof Copy Color Adjustments Slow Scan ModeOriginal CountMixed Size Original Stamp File(1) (2) (3) (4) (5) (6) When any of the functions on the color adjustments menu is selected, the Original Image Type setting for exposure adjustment automatically changes to Text/Prtd.Photo.