Home > NEC > Software > NEC Dsx 34b Manual

NEC Dsx 34b Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Dsx 34b Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 984
    							
    90xx-Utilities
    902x-Copy
    9021-Station Copy
    DSX Software ManualMaintenance Options: 9001-9211◆921
    Maintenance
    9001-9032
    902x-Copy
    9021-Station Copy
    Description
    Use this program to copy data from an extension to another extension or range of extensions.
    Options
    9021-01: Station Copy
    (Station Copy)
    This option allows you to copy station data from one extension to another extension or range of extensions. 
    The table below shows the programs you can copy.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    • Turn to the following page for help using 9021: Station Copy.
    Default
    • None
    9021 - Station Copy Program Options
    OptionStation ProgramOptionStation Program
    01
    2101-Type (Station Type)1132122-Ring Override
    022102-Access142123-BLF
    032103-Ringing152124-Soft Keys
    042104-Display162131-Lines
    052111-Features172132-Ringing
    062112-Speaker Control182133-Line Groups
    072113-Groups192141-Type (Mailbox Type)
    082114-Off Hook202142-Setup (Mailbox Setup)
    092115-Hunt/Over flow212143-Options (Mailbox Options)
    102116-Off Hook Signal222144-Auto-Attendant (Mailbox AA Options)
    112117-Call Logging232151-Assignment (Personal Speed Dial Bins)
    122121-Feature Keys
    1 2101-02: Names data is not copied 
    						
    							
    90xx-Utilities
    902x-Copy
    9021-Station Copy
    922◆Maintenance Options: 9001-9211 DSX Software Manual
    Using 9021-01: Station Copy
    To copy data from an extension to another extension or range of extensions: 1.
    Access option 9021-01. You see: Copy Program
    2.Press HOLD and select the option (01-23) corresponding to the station program yo\
    u want to copy.
    • You can dial the option number (01-23) or press Volume Up and Volume Down to scroll through the selections.
    3.Press HOLD. You  see: From Extension
    4.Enter the source extension number + HOLD. You  see: To Extension
    • This is the extension  from which the data will be copied.
    5.Enter the target extension number + HOLD. You  see: Thru Extension
    • This is the extension  to which the data will be copied.
    • If you are copying data to a range of extensions, this is the  first (lowest) extension in the range.
    6.Do one of the following.
    a.If copying data to a single extension, re-enter the extension you entered in step 5 above + HOLD.
    b.If copying data to a range of extensions, enter the highest (last) extension in the range + HOLD.
    7.When the copy has successfully completed, you see: Copy Complete 
    						
    							
    90xx-Utilities
    902x-Copy
    9022-Line Copy
    DSX Software ManualMaintenance Options: 9001-9211◆923
    Maintenance
    9001-9032
    9022-Line Copy
    Description
    Use this program to copy data from a line to another line or range of lines.
    Options
    9022-01: Line Copy
    (Line Copy)
    This option allows you to copy data from one line to another line or range of lines. The table below shows 
    the programs you can copy.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    • Turn to the following page for help using 9022: Line Copy.
    Default
    • None
    9022 - Line Copy Program Options
    OptionLine ProgramOptionLine Program
    01
    3101-Type (Line Type)173121-Settings (Caller ID)
    023102-Access83122-Groups (Caller ID)
    033103-Settings93131-Settings (Voice Mail)
    043111-Features103141-Dialing (Tie Line)
    053112-Termination113142-Line Access (Tie Line)
    063113-Ringing123143-Group Access (Tie Line)
    1 3101-02: Names data is not copied 
    						
    							
    90xx-Utilities
    902x-Copy
    9022-Line Copy
    924◆Maintenance Options: 9001-9211 DSX Software Manual
    Using 9022-01: Line Copy
    To copy data from a line to another line or range of lines: 1.
    Access option 9022-01. You see: Copy Program
    2.Press HOLD and select the option (01-12) corresponding to the line program you w\
    ant to copy.
    • You can dial the option number (01-23) or press Volume Up and Volume Down to scroll through the selections.
    3.Press HOLD. You  see: From Line
    4.Enter the source line number + HOLD. You  see: To Line
    • This is the line  from which the data will be copied.
    5.Enter the target line number + HOLD. You  see: Thru Line
    • This is the line  to which the data will be copied.
    • If you are copying data to a range of lines, this is the  first (lowest) line in the range.
    6.Do one of the following.
    a.If copying data to a single line, re-enter the line you entered in step 5 above + HOLD.
    b.If copying data to a range of lines, enter the highest (last) line in the ra\
    nge + HOLD.
    7.When the copy has successfully completed, you see: Copy Complete 
    						
    							
    90xx-Utilities
    903x-Swap Ports
    9031-Station Swap
    DSX Software ManualMaintenance Options: 9001-9211◆925
    Maintenance
    9001-9032
    903x-Swap Ports
    9031-Station Swap
    Description
    Use this program swap two extensions. This swaps  all the programming between the two extensions, includ-
    ing the extension number and station name. With 9031-Station Swap, it is no longer necessary to install and 
    wire cross-connect blocks to easily swap two extensions.
    Options
    9031-01: Station Swap
    (Swap with Ext)
    This option allows you swap two extensions. This swaps  all the programming between the two extensions. If 
    the extension being swapped is a 2PGDAD Module Door Box port with the secondary port assigned, this 
    program will also swap the secondary port.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    • See below.
    Default
    • None
    Using 9031-01: Station Swap
    To swap two extensions:
    1.
    Access option 9031-01.
    2.Press TRANSFER and select the  first extension.
    3.Press HOLD and enter the second extension.
    4.Press HOLD again to make the swap. You see: Swap Complete!
    • You cannot swap an extension busy on a call. 
    						
    							
    90xx-Utilities
    903x-Swap Ports
    9032-Line Swap
    926◆Maintenance Options: 9001-9211 DSX Software Manual
    9032-Line Swap
    Description
    Use this program swap two line circuits. For example, if you swap line 1 with line 2, line 1 now uses the 
    telco circuit formerly assigned to line 2 and vise versa. With 9032-Line Swap, it is no longer necessary to 
    install and wire cross-connect blocks to easily swap two lines.
    Options
    9032-01: Line Swap
    (Swap with Ext)
    This option allows you swap two line circuits.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    • See below.
    Default
    • None
    Using 9032-01: Line Swap
    To swap two lines: 1.
    Access option 9032-01.
    2.Press TRANSFER and select the  first line extension number.
    3.Press HOLD and enter the second line extension number.
    4.Press HOLD again to make the swap. You see: Swap Complete! 
    						
    							
    90xx-Utilities
    904x-Backup/Restore
    9041-Backup
    DSX Software ManualMaintenance Options: 9001-9211◆927
    Maintenance
    9001-9032
    904x-Backup/Restore
    9041-Backup
    Description
    Use this option to back up (save) the system database to a CompactFlash Card plugged into the IntraMai\
    l 
    CompactFlash Card slot. You can then restore (load) the system database using  9042-Restore (page 928). 
    You can store the system database on the IntraMail CompactFlash Card or o\
    n a separate FAT16 or FAT32 
    formatted CompactFlash card. The entire system database uses about 500 Kbytes Of Compact Flash mem-
    ory. See your system’s  Hardware Manual for more and how to install a CompactFlash Card.
    Options
    9041-01: Backup to CompactFlash
    (Backup to CF)
    Use this option to back up the system database to a CompactFlash Card. You can use  9042-Restore 
    (page 928) to restore the saved data.
    F
    eatures
    •System Programming Backup and Restore  (page 335)
    Intr
    aMail Features
    • None
    Options
    •No (0) - Do not backup
    •
    Ye s (1) - Start backup
    Default
    • None
    Using 9041-01: Backup
    To backup your DSX system database: 1.
    Insert your CompactFlash card into the system’s IntraMail CompactFlash Card slot. • You can use your IntraMail CompactFlash for backup or a standard FAT16/FAT32 formatted card.
    • The DSX system database only takes up 500K Bytes of your CompactFlash Card memory.
    2.Access option 9041-01. You see: Backup to CF
    2.Press HOLD and do one of the following.
    a.
    Dial 1 (Yes) + HOLD to begin the backup.
    • During the backup: - You  see:
     Please Wait
    - The CPU Serial Port LED (DS-80/160) winks on (green).
    - The CompactFlash LED occasionally winks on (red).
    • When the backup completes (after about 1 minute), you see: 
    Backup Complete!
    b.Dial 0 (No) + SPEAKER to abort the backup. 
    						
    							
    90xx-Utilities
    904x-Backup/Restore
    9042-Restore
    928◆Maintenance Options: 9001-9211 DSX Software Manual
    9042-Restore
    Description
    Use this option to restore (load) the database previously backed-up (saved) on a CompactFlash Card using 
    9041-Backup (page 927). Note that you can store the system database on the IntraM\
    ail CompactFlash Card 
    or on a separate FAT16 or FAT32 formatted CompactFlash card. The entire system database uses about 500 
    Kbytes Of Compact Flash memory. See your system’s  Hardware Manual for more and how to install a Com-
    pactFlash Card.
    Options
    9042-01: Restore from CompactFlash
    (Restore from CF)
    Use this option to restore the system database previously saved to a CompactFlash Card using  9041-Backup 
    (page 927).
    F
    eatures
    •System Programming Backup and Restore  (page 335)
    Intr
    aMail Features
    • None
    Options
    •No (0) - Do not restore
    •
    Ye s (1) - Start restore
    Default
    • None
    Using 9042-01: Restore
    To restore your DSX system database: 1.
    Insert your CompactFlash card into the system’s IntraMail CompactFlash Card slot. • Use the same CompactFlash Card to which you previously backed up the site data.
    2.Access option 9042-01. You see: Restore from CF
    2.Press HOLD and do one of the following.
    a.Dial 1 (Yes) + HOLD to begin the restore.
    • The system will automatically restart with the restored data loaded.
    b.Dial 0 (No) + SPEAKER to abort the restore. 
    						
    							
    DSX Program List929
    DSX 
    Program List
    DSX Program List
    DSX Program List
    System Options: 1001-1702
    10xx-Configuration
    100x-System 1001-Version 1001-01: System Type
    1001-02: Software Version
    1001-03: DSP Version
    101x-ID 1011-Name 1011-01: System Name
    1011-02: Telephone Number
    Name Programming Chart
    102x-Time 1021-Set Time and Date 1021-01: System Time
    1021-02: System Date
    1022-Daylight Savings Time 1022-01: Automatic Daylight Savings Time Setting
    1023-Internet (Network Time Server [NTS]) 1023-01: Network Time Server Name
    103x-Programming 1031-Password Entry 1031-01: New Password
    11xx-CPU
    110x-I/O1101-RS232 Settings 
    						
    							
    DSX Program List
    930DSX Program List
    1101-01: Baud Rate
    1102-Modem Settings
    1103-USB Settings
    1104-Ethernet Setup 1104-01: System IP Address
    1104-02: System Subnet Mask
    1104-03: Default Gateway
    111x-Tones 1111-DTMF Setup 1111-01: Manual DTMF Tone On
    1111-02: Manual DTMF Tone Off
    1111-03: Speed Dial DTMF Tone On
    1111-04: Speed Dial DTMF Tone Off
    12xx-Slots
    120x-Stations1201-Type (Station Card Type) 1201-01: Card Type
    1202-Ports (Primary Station Ports) 1202-01: Primary Station Port Assignment
    1203-Secondary Station Ports 1203-01: Secondary Station Port Assignment
    121x-Lines 1211-Lines (Line Card Type) 1211-01: Card Type
    1212-Ports 1212-01: Line Port Assignment
    1213-T1/E1 Card Setup 1213-01: Number of PCM Channels
    1213-02: Clock Control
    1213-03: Transmit Pulse Amplitude
    1213-04: Framer Type
    1213-05: Zero Suppression
    1213-06: Loopback Mode
    13xx-Numbering
    130x-Dial Plan1301-Digits 1301-[01-10]: Function Type
    1301-[01-10]: Expected Number of Digits
    131x-Extensions 1311-Stations 1311-01: Station Extension Number
    1312-Voice Mail Ports 1312-01: Voice Mail Extension Number
    1313-Lines 1313-01: Line Extension Number
    1314-Ring Groups 1314-01: Ring Group Master Extension Number
    1315-UCD Groups 1315-01: UCD Group Master Extension Number
    14xx-COS (Class of Service)
    140x-Station1401-Features 
    						
    All NEC manuals Comments (0)