    16xx-Timers
    160x-Feature Timers
    1605-Control Timers
    DSX Software ManualSystem Options: 1001-1702◆681
    System
    1001-1702
    1605-04: Forced Program Exit Timer
    (Program Exit)
    Use this option to set the Forced Program Exit timer. If a telephone in the programming mode is inactive longer 
    than this interval, the system automatically cancels the programming mode and makes the telephone idle.
    Features
    • None
    Intr
    aMail Features
    • None
    Options
    •1-9999 seconds
    •
    0 for disabled
    Default
    •120 seconds
    1605-05: Backlight Idle Timer
    (Backlight Idle)
    Use this option to set how long an extension must be idle before it reverts to its idle backlight brightness setting.
    Features
    • Station Key Telephones  (page 325)
    Intr
    aMail Features
    • None
    Options
    •1-9999 seconds
    •
    0 for disabled
    Default
    •6 seconds 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1611-Incoming
    682◆System Options: 1001-1702 DSX Software Manual
    161x-COI (Analog Line) Timers
    1611-Incoming
    Description
    Use this program to adjust timers that affect incoming calls on the line (COIU) PCBs.
    Options
    1611-01: Minimum Ring Detect Timer
    (Ring Detect)
    Use this option to set the threshold for ring detection. If the ring sig\
    nal is longer than this interval, the system 
    interprets the signal as valid ringing. If the signal is equal to or shorter than this interval, the system ignores 
    the ringing. Be sure the value you enter is compatible with the local telco. If you set this value too short, the 
    system may detect line spikes and anomalies as ringing. If too long, the system may not properly in\
    terpret a 
    valid ringing signal.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •8-2040 mS
    Default
    •104 mS
    1611-02: Minimum Single Ring Detection Timer
    (Single Ring Min)
    The system uses this option to detect valid ringing signal from the connected telco or PBX. Valid single ring 
    must be longer than this interval. F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •8-2040 mS
    Default
    •1216 mS 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1611-Incoming
    DSX Software ManualSystem Options: 1001-1702◆683
    System
    1001-1702
    1611-03: Minimum Double Ring Detection Off Timer
    (Double Ring Min)
    The system uses this option to detect valid double ring from the connected PBX. Valid double ring must be 
    longer than this interval.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •8-2040 mS
    Default
    •288 mS 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1611-Incoming
    684◆System Options: 1001-1702 DSX Software Manual
    1611-04: Maximum Double Ring Detection Off Timer
    (Double Ring Max)
    The system uses this option to detect valid double ring from the connected PBX. Valid double ring must be 
    less than this interval.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •8-2040 mS
    Default
    •576 mS
    1611-05: Ringing Signal End Detection Timer
    (Ring Stop)
    Use this option to set the Ringing Signal End Detection time. If the rin\
    ging signal on a line call is interrupted 
    for longer than this interval, the system assumes ringing has stopped and terminates the call. Set \
    this option 
    for compatibility with the connected telco or PBX Centrex. If this interval is set to short, valid ringing will 
    be inadvertently cut off. If too long, the system will leave the call set up even after ringing has stopped. F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •64-16320 mS
    Default
    •6016 mS
    1611-06: Caller ID Detection Timer
    (CID Detect)
    Use this option to set the Caller ID Detection Timer. With DSP-based Caller ID, the Caller ID Detection 
    Timer is the amount of time between the  first and second ring bursts that the system can detect Caller ID dig-
    its. If this timer is set too long, the outside caller will hear ringing\
     followed by reorder tone. If set too short, 
    all the Caller ID digits may not be detected. This timer is only used with DSP-based Caller ID. This option 
    does not apply to COIU PCBs.
    F
    eatures
    •Caller ID  (page 63)
    Intr
    aMail Features
    • Caller ID and Voice Mail  (page 456)
    • Make Call  (page 525)
    Options
    •64-16320 mS
    Default
    •2944 mS 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1612-Outgoing
    DSX Software ManualSystem Options: 1001-1702◆685
    System
    1001-1702
    1612-Outgoing
    Description
    Use this program to adjust timers that affect outgoing calls on the line (COIU) PCBs.
    Options
    1612-01: DP Break Timer
    (Break Time)
    Use this timer to set the duration of the Dial Pulse Break signal (i.e.\
    , relay open). This is the “off” time in a 
    Dial Pulse digit. Set this timer for compatibility with the connected te\
    lco or PBX/Centrex. Keep in mind that 
    there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An 
    improper setting may cause misdialing.
    F
    eatures
    •Central Of fice Calls, Placing  (page 78)
    Intr
    aMail Features
    • None
    Options
    •4-1020 mS
    Default
    •60 mS
    1612-02: DP Make Timer
    (Make Time)
    Use this timer to set the duration of the Dial Pulse Make signal (i.e., relay closed). This is the “on” time in a 
    Dial Pulse digit. Set this timer for compatibility with the connected te\
    lco or PBX/Centrex. Keep in mind that 
    there are three components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An 
    improper setting may cause misdialing. F
    eatures
    •Central Of fice Calls, Placing  (page 78)
    Intr
    aMail Features
    • None
    Options
    •4-1020 mS
    Default
    •40 mS
    1612-03: DP Interdigit Timer
    (Interdigit Time)
    Use this timer to set the duration of the Dial Pulse Interdigit signal (\
    i.e., relay open time  between  each digit). 
    Set this timer for compatibility with the connected telco or PBX/Centrex. Keep in mind that there are three 
    components of a Dial Pulse digit: Make interval, Break interval and Interdigit interval. An improper setting 
    may cause misdialing.
    F
    eatures
    •Central Of fice Calls, Placing  (page 78)
    Intr
    aMail Features
    • None 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1612-Outgoing
    686◆System Options: 1001-1702 DSX Software Manual
    Options
    •100-9999 mS
    Default
    •800 mS
    1612-04: PBX/Centrex Flash Timer
    (Flash 1 Time)
    Use this timer to set the Flash interval. When a user  flashes a line (manually or in a Speed Dial number), the 
    system opens the line circuit for this interval. For accurate  flash function, be sure to set this interval for com-
    patibility with the connected telco or PBX/Centrex. If you set this interval too short, the telco may not 
    always register the  flash. If too long, inadvertent disconnects may occur.
    F
    eatures
    • Flash  (page 177)
    • Speed Dial  (page 315)
    Intr
    aMail Features
    • Centrex Transfer  (page 460)
    Options
    •16-4080 mS
    Default
    •800 mS
    1612-05: Flash Disconnect Timer
    (Flash 2 Time)
    This option is currently not implemented. F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •16-4080 mS
    Default
    •2496 mS
    1612-06: Ground Start Timer
    (Ground Time)
    Before the system can start a ground start line, the telco’s tip ground must be present for longer than this 
    interval. Set this interval for compatibility with the connected telco or PBX/Centrex. If you set this interval 
    too short, the system may inadvertently start a line it should not set up. If too long, the system may \
    not start 
    lines that are functioning normally. F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •16-4080 mS
    Default
    •800 mS 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1612-Outgoing
    DSX Software ManualSystem Options: 1001-1702◆687
    System
    1001-1702
    1612-07: Shunt Pause Timer
    (Shunt Pause)
    Use this option to set the Shunt Pause Timer (Dial Pulse Mute Timer) for the ATRU PCB. While dial pulsing 
    or doing a Flash, the ATRU PCB switches a low resistance shunt across tip and ring to maintain the correct 
    impedance on the line. When dialing or  flashing is complete, the ATRU PCB waits this interval before 
    releasing the shunt.
    This option does not apply to the COIU PCB.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •4-1020 mS
    Default
    •8 mS 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1613-Loop Control
    688◆System Options: 1001-1702 DSX Software Manual
    1613-Loop Control 
    Description
    Use this program to adjust timers that affect the loop on the line (COIU) PCBs.
    Options
    1613-01: Loop Current Detection Timer
    (Loop Detect)
    For loop start lines, loop current must be present for this interval before the system seizes the line. Set this 
    interval for compatibility with the connected telco or PBX/Centrex. If you set this interval too short, the sys-
    tem may inadvertently seize unstable lines. If too long, the system may not properly \
    seize a valid line.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •4-1020 mS
    Default
    •800 mS
    1613-02: Far End Disconnect Timer
    (Clear Signal)
    Use this option to set the loop disconnect interval for outside calls. If the system detects a loop current inter-
    ruption longer than this interval it assumes the telco has disconnected the line. It then returns the l\
    ine to idle.
    Set this interval for compatibility with the connected telco or PBX/Centrex. If you set the interval too short, 
    lines may not properly disconnect when the far end hangs up. If you set the interval too long, the system may 
    interpret momentary loop current interruptions as positive disconnect. F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •4-1020 mS
    Default
    •300 mS 
    						
    							
    16xx-Timers
    161x-COI (Analog Line) Timers
    1613-Loop Control
    DSX Software ManualSystem Options: 1001-1702◆689
    System
    1001-1702
    1613-03: Power Failure Recovery Detect Timer
    (Loop Recovery)
    Use this option to set the Power Failure Recovery Detect time. When the ATRU or COIU PCB recovers from 
    a power failure, it checks the power failure line for loop current for this interval. If loop current is detected, it 
    assumes the power failure telephone is still connected and does not tear down the call. If loop current is not 
    detected, the PCB switches the line out of the power failure mode.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •64-16320 mS
    Default
    •3008 mS 
    						
    							
    16xx-Timers
    162x-SLI (Analog Single Line) Timers
    1621-Incoming
    690◆System Options: 1001-1702 DSX Software Manual
    162x-SLI (Analog Single Line) Timers
    1621-Incoming
    Description
    Use this program to adjust the timers that affect incoming calls to analog single line telephones.
    Options
    1621-01: Minimum DP Break Timer
    (Minimum Break)
    Use this option to define the minimum amount of time the loop must be opened to properly decode\
     the dial 
    pulse digits sent from analog devices connected to single line PCBs.  Change this value only if the con-
    nected analog devices are set to dial at a rate other than 10 PPS.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •5-1275 mS
    Default
    •10 mS
    1621-02: Maximum DP Break Timer
    (Maximum Break)
    Use this option to de fine the maximum amount of time the loop must be opened to properly decode\
     the dial 
    pulse digits sent from analog devices connected to single line PCBs.  Change this value only if the con-
    nected analog devices are set to dial at a rate other than 10 PPS.
    F
    eatures
    • None
    Intr
    aMail Features
    • None
    Options
    •5-1275 mS
    Default
    •100 mS 
    						