    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-9 Preliminary Procedures 
    3
    Check Software Release Letter
    1. Check the Software Release Letter that ac c omp anies the Release 8 
    removab le media. This letter c ontains the rec ommend ed  up g rade 
    proc edures. Always use the 
    Software Release Letter when up g rad ing  a 
    system. 
    2. If the letter is not inc lud ed  with the Release 8 removab le med ia, p erform 
    the following procedures. 
    Busyout Multimedia Interface Circuit Packs
    Perform this step  only if the system is hig h or c ritic al reliab ility and  c ontains 
    MMCH c irc uit p ac ks. Multimed ia-to-voic e station c alls are 
    not p reserved  on an 
    up g rad e. Failure to b usy-out the TN787 Multimed ia Interfac e c irc uit p ac ks will 
    result in unusab le TN787 and  TN788 Multimed ia Voic e Cond itioner p orts.
    1. Type display system-parameters customer-options
     and  p ress 
    En t e r. If 
    the MMCH op tion is set to y
    , c ontinue to step  2. If not, skip  to ‘‘Save 
    Translations and Announcements’’. 
    2. Type list configuration all
     and  p ress 
    En t e r. Loc ate all of the TN787 
    Multimed ia Interfac e c irc uit p ac ks.
    3. Type busyout board
      and press 
    En t e r  for eac h TN787. This 
    p revents any further multimed ia-to-voic e c onnec tions and  d rop s all ac tive 
    c onnec tions.
    Save Translations and Announcements
    1. Log  in at the manag ement terminal on the Release 5/6 system.
    2. If the system is d uplex, typ e status system
     and press 
    En t e r  to verify the 
    system is in the ‘‘ac tive/stand b y mode.
    3. Type save translation
     and press 
    En te r. This instruc ts the system to write all 
    translation information from memory to the translation c ard s.
    4. Chec k for translation errors before p roc eed ing  with the up g rad e. If errors 
    are d etec ted , refer to ‘‘No Translations After Upgrade’’
     in Appendix B, 
    ‘‘Troubleshooting  an Upgrade’’ to c orrec t the p rob lem. Do not c ontinue 
    until the errors are c orrec ted . 
    5. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type 
    display announcements
     and  p ress 
    En t e r.
    6. If administered  rec ord ed  announc ements are listed , typ e save 
    announcements
     and  p ress 
    En te r.
    7. Remove the translation c ard and  install the b ac kup  removab le media or 
    card. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-10 Release 5/6si to Release 8r 
    3
    Release 5/6si to Release 8r
    During  the wiring  of the PPN installation, lab el the MDF with the new PN numb er 
    of the Release 5/6si PPN. The STS software up g rad e assigns the next PN numb er 
    (after the hig hest numbered  PN in the Release 5/6si system) to the up g rad ed  
    Release 8r EPN.
    Required Tools
    The following tools and  items may b e req uired  d uring  the up g rad e:
    n1/4-inc h flat b lad e sc rewd river
    n1/4-inc h soc ket with ratc het (op tional)
    nLong -nose p liers to straig hten b ac kp lane p ins
    nStatic -p roof or orig inal c irc uit p ac k p ac kag ing  for transp orting  c irc uit 
    packs
    nLab els for id entifying  the p ort c irc uit p ac ks and  c ab les attac hed  to the 
    rear of c ab inets
    nRep air kit for b ac kp lane p ins (KS-22876 L2 or eq uivalent)
    nOne c op y of eac h of the following  manuals:
    — DEFINITY Enterp rise Communic ations Server Release 8 
    Maintenanc e for R8r
    — DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-11 Release 5/6si to Release 8r 
    3
    Required Hardware
    The eq uip ment in Table 3-2 must be on-site before the upgrade begins.
    Table 3-2. Required Hardware
    Equipment Description Quantity
    J58890N Expansion Control Cab inet 1
    106647985 TN775B Maintenance circ uit p ac k  1
    103281788 TN570 Exp ansion Interface circuit p ack Dep end s on reliab ility type 
    and numb er of PNs
    103281812 TN573B Switc hed  Nod e Interfac e c irc uit p ac k Dep end s on reliab ility type 
    and numb er of PNs
    407439975 or
    40759832520-Foot Multi-Mod e Fib er Op tic  Cable
    20-Foot Sing le-Mod e Fib er Op tic  Cable1 to 12
    106455348 or
    106455363 or
    1077318539823-A Lig htwave Transc eiver
    9823-B Lig htwave Transc eiver
    300A Lig htwave Transceiver2 to 12
    1
    2 to 121
    2 to 122
    1. For eac h fib er connec tion, 1 lig htwave transc eiver is installed  in 1 p ort network, and  a like transceiver
    in the adjacent p ort network. 4E transc eivers c annot b e reused. Add itional transceivers, ord ered
    sep arately, ship  loose with the EPN eq uip ment.
    2. The 300A is c onnec ted  using  2 fib er optic  c ables. 5, 10, or 15 dB attenuators may b e required . J58890to-O L1 Release 8 Removab le Med ia 2 or 4
    3
    3. Dep ending on the reliab ility type of the Release 8r system. Two removab le med ia are req uired for a
    stand ard reliability system; 4 for a hig h or c ritic al reliab ility system. 106689516 TN771D Maintenance Test c irc uit p ac k 1 or 2
    4
    4. Dep ending on the numb er of EPNs in a critic al reliab ility Release 8r system.846307817 Lower Rear Cover 1
    5
    5.Req uired  for the ‘‘B port cab inet of a c ritical reliab ility Release 8r EPN.  846307809 Ground Plate 1
    H600-248 G1 ICC Cab les 2
    6
    6. Req uired  for a c ritic al reliab ility Release 8r EPN.
    846408268 Earthq uake Front Panel (earthquake p rotec tion only) 1
    846408386 Earthq uake Ground  Plate (earthq uake p rotection only) 1 
    846408250 Stiffener (earthquake protec tion only) 1 
    846408243 Earthq uake Front Mounting  Ang le (earthq uake 
    p rotec tion only)1 
    106060718 5 d B attenuator (sing le-mod e fib er only) 2 for each fib er c onnec tion
    2
    106060734 10 dB attenuator (sing le-mod e fiber only) 2 for each fib er c onnec tion2
    106061021 15 dB attenuator (sing le-mod e fiber only) 2 for each fib er c onnec tion2 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-12 Release 5/6si to Release 8r 
    3
    Follow Routine Preventive Maintenance
    1. During  the up g rad e, follow routine p reventive maintenanc e p roc ed ures on 
    the system to b e up g rad ed . For more information, refer to the “ Preventive 
    Maintenanc e”  sec tion in 
    DEFINITY Enterp rise Communic ations Server 
    Release 8 Maintenanc e for R8r
    .
    Label Cables
    1. To make rec onnec ting  the c ab les simp ler and  more reliable, lab el every 
    c onnec tor c ab le assoc iated  with the system.
    Check Link Status
    1. Type display communication-interface links
     and  p ress En t e r. 
    2. Make note of all enab led links.
    3. Type status link
       and  p ress 
    En t e r.
    4. Chec k the following  items and  note whic h links are in-servic e. You will 
    need  this information after the up g rad e.
    nPPP li n k s
    nAud ix links
    nISDN
    nBX25
    nEthernet
    5. Repeat steps 3 and 4 for each enabled link.
    Disable TTI
    !CAUTION:
    If you d o not d isab le the TTI, the translations c an b e c orrup ted .
    1. Make sure the ISDN is in servic e. If not, attempt to b usy out and release 
    the ISDN D-c hannel/link. This will b ring  the ISDN trunks b ac k into servic e.
    2. Type change system-parameters features
     and press 
    En t e r. 
    3. On the sec ond  sc reen, set the Enabled?
     field  to n
     to d e-ac tivate the TTI 
    feature. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-13 Release 5/6si to Release 8r 
    3
    Shut Down DEFINITY LAN Gateway System
    !WARNING:
    Neg lec ting  to shut d own a DEFINITY LAN Gateway assemb ly b efore 
    p owering  d own the system c ab inet c an d amage the LAN Gateway d isk.
    1. Log  onto the DEFINITY LAN Gateway. See the DEFINITY Communic ations 
    System Generic  3 Installation, Ad ministration and  Maintenanc e of 
    CallVisor ASAI over the DEFINITY LAN Gateway
     for the p roc ed ure to log  
    on.
    2. When the main menu ap p ears, selec t 
    Maintenanc e.
    3. Select 
    Reset System from the Maintenanc e menu.
    4. Select 
    Sh u t d o w n from the Res et Sy ste m menu.
    5. Unseat the LAN Gateway assemb ly from its b ac kp lane c onnec tors.
    Shut Down DEFINITY AUDIX System
    1. If a DEFINITY AUDIX System resid es in the system to b e up g rad ed , shut 
    d own the AUDIX assemb ly and  allow the d isk to c omp letely sp in d own. 
    Refer to the ‘‘DEFINITY AUDIX Power Procedures’’
     at the end  of this 
    chapter.
    !WARNING:
    Neg lec ting  to shut d own an AUDIX assembly b efore p owering  d own 
    the system c ab inet where it resides c an damag e the AUDIX d isk.
    2. Unseat the AUDIX assemb ly from its b ac kp lane c onnec tors.
    Power Down Existing System
    1. At eac h PPN c ab inet p ower supp ly, set the main c irc uit b reaker to OFF.
    !CAUTION:
    Powering  d own the PPN will c ause imp ortant system d ata, suc h as 
    BCMS d ata, rec ord s of queued  ACD c alls, Automatic  Wakeup  
    req uests, and  Do Not Disturb  req uests to b e lost. Refer to DEFINITY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8r, 
    for information ab out p rep aring  the system for a p ower d own.
    2. At eac h EPN c ab inet p ower supp ly, set the main c irc uit b reaker to OFF. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-14 Release 5/6si to Release 8r 
    3
    Disconnect Power and Ground
    1. Disc onnec t the c ab inet p ower c ord s from the rear of eac h c ab inet.
    2. Disconnect the 10 AWG (#25) (2.6 mm
    2) c oup led b ond ing  c ond uc tor wire.
    3. Disc onnec t the 6 AWG (#40) (4.1 mm
    2) c ab inet g round  wire from the 
    g round  b ar in the c ab inet.
    Install Emergency Transfer Ground Wire
    !CAUTION:
    To avoid  c ontaminating  single-p oint g round , do not c onnec t the g round  
    strap  while the system is p owered  up .
    1. Connect a 10 AWG (#25) (2.6 mm2) wire either to pin 49 of the c onnec ting  
    b loc k or to p in 49 of the CAP (c ab le ac c ess p anel) assoc iated  with the 
    emergenc y transfer p anel.
    2. Route the other end  of the wire to an ap p roved  g round  and  c onnec t.
    Disconnect Equipment and Cables
    1. Disc onnec t all of the c onnec tor c ab les attac hing  to the PPN.
    2. Disc onnec t the PC from the TERM c onnec tor.
    3. Remove the g round  p late(s) from b etween all of the PPN c ab inets.
    4. Remove the top  and bottom rear c overs from all of the PPN c ab inets.
    Remove Circuit Packs
    1. Lab el eac h p ort c irc uit p ac k in the c ontrol c ab inet with its slot numb er.
    2. Remove all c irc uit p ac ks and  p ower units from the c ontrol c ab inet. Store 
    the c irc uit p ac ks in the static -p roof p ac kag ing .
    NOTE:
    If a TN756 tone-d etec tor/g enerator was removed  from the Release 
    5/6si, a new Release 8r tone c loc k (TN2182B) rep lac es this c irc uit 
    p ac k. The TN2182B Tone-Cloc k rep lac es the tone d etec tor c irc uits 
    on the TN756. A TN2182B eliminates the need for a TN748B. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-15 Release 5/6si to Release 8r 
    3
    Disconnect TDM/LAN Cables and ICC Cables
    1. Remove and  retain all of the TDM/LAN c ab les. 
    2. If the Release 5/6si system is stand ard  reliab ility, remove and  retain the 
    ICC c ab les.
    3. If the Release 5/6si system is duplicated, remove the ICC cables. They are 
    rep lac ed  with new ICC c ab les (H600-248 G1).
    Remove the Existing Control Cabinet
    Sinc e the c ontrol c ab inet is at the b ottom of the p ort network, d ismantle the 
    c ab inet stac k. Disc onnec t all the p ower, ground , TDM, ICC, and  c onnec tor 
    cables.
    1. Remove the c ab inet c lip b etween eac h c ab inet or front earthq uake p late 
    as p rovid ed .
    2. Remove the rear g round  p late.
    3. Remove the p ort c ab inets from the stac k.
    !CAUTION:
    A p ort c ab inet may weigh as muc h as 125 p ounds. Use lifting  
    p rec autions. 
    4.If the system is d up lic ated , remove the c ontrol c ab inet in p osition ‘‘B. It is 
    not reused.
    5. If the b asic  c ontrol c ab inet in p osition ‘‘A is earthq uake mounted , remove 
    and  retain the hard ware sec uring  the c ab inet to the floor.
    6. Remove the b asic  c ontrol c ab inet. It is not reused .
    Unpack and Install Expansion Control Cabinet
    1. Unp ac k and  insp ec t the J58890N Exp ansion Control Cab inet. 
    2. Position the exp ansion c ontrol c ab inet at the desired  loc ation.
    3. Reinstall the earthq uake mounting  hard ware, if req uired.
    Install Port Cabinets
    1. Rep lac e the p ort c ab inets into their p rop er p ositions. 
    NOTE:
    For a dup lic ated  Release 5/6si, the J58890M Control Cabinet c an b e 
    rep lac ed  b y a J58890H Port Cab inet in p osition ‘‘B. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-16 Release 5/6si to Release 8r 
    3
    Install Circuit Packs
    1.Rep lac e the c irc uit p ac ks and  power supp lies in p ort c ab inets “ C”  and  “ D”  
    if they were p reviously removed .
    2. Using  the lab el on the front of the c arrier and  the annotated  “ list 
    c onfig uration all”  (provid ed  with the Release 8r removab le med ia), install 
    the c ontrol c irc uit p ac ks into the new exp ansion c ontrol c ab inet.
    3. Install the p ort c irc uit p ac ks into the “ A”  c ab inet using  the lab el on the front 
    of the c arrier and  the annotated  “ list c onfig uration all”  as a g uide.
    NOTE:
    Sinc e the new Release 8r exp ansion c ontrol c arrier has 6 more p ort 
    slots than the removed  c ontrol c arrier, there should  b e no need  to 
    retranslate these c irc uit pac ks.
    4. For an EPN in a c ritic al reliab ility system, install a TN2182B Tone-Cloc k 
    and  a TN570 EI in slots “ 1”  and  “ 2”  of p ort c ab inet “ B.”  See Table 3-3
    .
    ’
    Change Cabinet Address Plugs
    If a d up lic ated  c ontrol c ab inet was removed from p osition “ B”  and  was not 
    rep lac ed  with a new p ort c ab inet, the up g rad ed  EPN’s p ort c ab inets oc c up y 
    d ifferent p ositions in the c ab inet stac k. 
    1. Behind  eac h p ort c abinet, find  the ad d ress p lug  attac hed  to 2 of the 6 
    b ac kp lane p ins to the rig ht of the p in-field b loc k for slot “ 00.”
    2. Chang e the loc ation of eac h p ort c ab inet ad d ress p lug  to reflec t the 
    c ab inet’s c urrent p osition. See Figure 3-1
    .
    Table 3-3. TN570 Expansion Interface Requirements
    Cabinet2 PNs w/o Critical 
    Reliability2 PNs w/Critical 
    Reliability3 PNs w/o Critical 
    Reliability3 PNs w/Critical 
    Reliability
    PPN 1 2 2 4
    EPN  1 1 2 2 4
    EPN  2 N / A N / A 2 4 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-17 Release 5/6si to Release 8r 
    3
    Figure 3-1. Cabinet Address Plug Location Figure Notes
    1. Ad dress Plug  (Shown Set to Carrier D)
    2. Carrier B Jump er Loc ation (Default)
    3. Carrier C Jumper Location
    4. Rig ht Edg e of Bac kp lane5. Rig ht Ed g e of Cabinet
    6. Bac kp lane Slot 00
    7. To Connec tor Panel 
    3
    45
    1
    6
    2
    7
    add_plug CJL 050906 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Upgrading R5si/R6si to R8r EPN and Adding Memory 
    3-18 Release 5/6si to Release 8r 
    3
    Install TDM/LAN Bus Terminators
    1. If the Release 5/6si PPN has only 1 c ab inet, install the 2 AHF110 TDM/LAN 
    b us terminators p er Figure 3-2
    .
    Figure 3-2. TDM/LAN Bus Terminators for Single-Carrier Cabinet EPN
    2. If the Release 5/6si PPN has more than 1 c abinet:
    a. Install the AHF110 TDM/LAN b us terminator in Slot 03 on the rig ht 
    sid e of the exp ansion c ontrol c ab inet as shown in Figure 3-3
    .
    b . Install the AHF110 TDM/LAN bus terminator on the top  p ort c ab inet, 
    at the end  of the daisy c hain of the b us. Figure Notes
    1.Control Cab inet (“ A”  Position)
    2. AHF110 TDM LAN/Bus Terminator 
    (Slot 18)3. AHF110 TDM LAN/Bus Terminator 
    (Slot 01) 
    						
    All Lucent Technologies manuals Comments (0)