    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-11 Administer Fiber Links 
    A
    Duplicated Fiber Link Administration. 
    Screen 6-2. Fiber Link Administration form (page 1 of 3)
    The following fields appear when Administration of PNC Duplication
     is 
    enab led  on the System-Parameters Customer-Op tions form:
    nFiber Link #
     — Disp lay-only field . From the c ommand  line, enter a 1- to 
    3-d ig it numb er to uniq uely id entify a switc h c onnec tion in the system and 
    its d up lic ate if ap prop riate.
    nIs one endpoint remoted via DS1 Converter Complex?
     — En t e r  yes
     to 
    sp ec ify that a DS1 c onverter c omp lex is used  to remote one end p oint. If 
    yes
     is entered , A-PNC and  B-PNC DS1 Converter (DS1CONV) Attrib utes 
    must b e ad ministered  on Pag es 2 and  3 (resp ec tively) of the form.
    nBoard Location
     — Enter the c ab inet, c arrier, and  slot that id entifies the 
    p hysic al loc ation of a c irc uit pac k in the first end p oint of the d up lic ate fib er 
    link. End p oint-1’s d up lic ate along  with End p oint-2’s d up lic ate make up  the 
    d up lic ate fib er link c alled  the B-PNC link.
    nBoard Type
     — Disp lay-only field  showing  the typ e of c irc uit p ac k in 
    End p oint-1. The c irc uit p ac k typ e in Endp oint-1 (A-PNC) and  End p oint-1 
    (B-PNC) must be the same.
    nDS1CONV Board Location
     — Enter the c ab inet, c arrier, and  slot that 
    id entifies the p hysic al loc ation of DS1 Converter c irc uit p ac k in the first 
    endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with 
    End p oint-2’s d uplic ate make up  the d up lic ate fib er link c alled  the B-PNC 
    link.
    add fiber-link next   Page 1 of 3
    FIBER LINK ADMINISTRATION
    Fiber Link #: 1
    Is one endpoint remoted via DS1 Converter Complex? yes
    ENDPOINT-1 ENDPOINT-2
    (A-PNC) (A-PNC)
    Board Location: 01E01  Board Location: 02A01
    Board Type: ei  Board Type: ei
    DS1CONV Board Location: 01B01  DS1CONV Board Location: 02B01
    DS1CONV Board Type: TN574  DS1CONV Board Type: TN574
    ENDPOINT-1 ENDPOINT-2
    (B-PNC) (B-PNC)
    Board Location: 01D01  Board Location: 02A02
    Board Type: ei  Board Type: ei
    DS1CONV Board Location: 01C01  DS1CONV Board Location: 02C01
    DS1CONV Board Type: TN574  DS1CONV Board Type: TN574 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-12 Administer Fiber Links 
    A
    nDS1CONV Board Type
     — Disp lay-only field showing  the type of DS1 
    Converter c irc uit pac k in End p oint-1. The c irc uit p ac k typ e in Endp oint-1 
    (A-PNC) and  End p oint-1 (B-PNC) must b e the same. This field is upd ated  
    via the Chang e Circ uit-pac ks c ommand.
    nBoard Location
     — Enter the c ab inet, c arrier, and  slot that id entifies the 
    p hysic al loc ation of a c irc uit p ac k in the sec ond  end p oint of the d up lic ate 
    fiber link. Endpoint-2’s duplicate along with Endpoint-1’s duplicate make 
    up  the d up lic ate fib er link c alled  the B-PNC link.
    nBoard Type
     — Disp lay-only field  showing  the typ e of c irc uit p ac k in 
    End p oint-2. The c irc uit p ac k typ e in Endp oint-2 (A-PNC) and  End p oint-2 
    (B-PNC) must be the same.
    nDS1CONV Board Location
     — Enter the c ab inet, c arrier, and  slot that 
    id entifies the p hysic al loc ation of DS1 Converter c irc uit pac k in the sec ond  
    endpoint of the duplicate fiber link. Endpoint-2’s duplicate along with 
    End p oint-1’s d uplic ate make up  the d up lic ate fib er link c alled  the B-PNC 
    link.
    nDS1CONV Board Type
     — Disp lay-only field showing  the type of DS1 
    Converter c irc uit pac k in End p oint-2. The c irc uit p ac k typ e in Endp oint-2 
    (A-PNC) and  End p oint-2 (B-PNC) must b e the same. This field is upd ated  
    via the Chang e Circ uit-pac ks c ommand.
    DS1C Converter Complex Administration for TN574 Circuit Packs. 
    Screen 6-3. Fiber Link Administration form for TN574 Circuit Pack (DS1 Converter 
    Complex Administration) (page 2 of 3)
    add fiber-link next  Page 2 of 3
     FIBER LINK ADMINISTRATION
    A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
    DS1CONV Board Location: 01B01  DS1CONV Board Location: 02B01
    DS1CONV Board Type: TN574  DS1CONV Board Type: TN574
    DS1 CONVERTER FACILITIES
      ABC D
             Facility Installed? yes  no  no  no
           Passes Far-end Clock? yes  yes  yes  yes
        Digital Data Compatible? yes  yes  yes  yes
                    Line Coding: ami-zcs  ami-zcs ami-zcs ami-zcs
                   Framing Mode: esf esf esf esf
    DS1CONV-1 Line Compensation: 1 1 1 1
    DS1CONV-2 Line Compensation: 1 1 1 1
    Facility A Circuit ID: 09876543 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-13 Administer Fiber Links 
    A
    The following DS1 Converter Comp lex field s ap p ear on Pag e 2 when the Is one 
    endpoint remoted via a DS1 Converter Complex field is y
    .
    NOTE:
    When you ad minister DS1 Converter TN1654 c irc uit p ac ks, d ifferent field s 
    display.
    nDS1CONV Board Location
     — Enter the c ab inet, c arrier, and  slot that 
    id entifies the p hysic al loc ation of the c onverter c irc uit p ac k c onnec ted  to 
    the first end point of the fib er link. This is entered  on Pag e 1 and  d isp lays 
    on Pag e 2.
    nDS1CONV Board Type
     — Disp lay-only field showing  the type of DS1 
    Converter c irc uit pac k for the first end p oint. 
    nDS1CONV Board Location
     — Enter the c ab inet, c arrier, and  slot that 
    id entifies the p hysic al loc ation of the c onverter c irc uit p ac k c onnec ted  to 
    the sec ond end p oint of the fib er link.
    nDS1CONV Board Type
     — Disp lay-only field showing  the type of DS1 
    Converter c irc uit pac k for the sec ond  end point. This field  is up d ated via 
    the Chang e Circ uit-p ac ks c ommand .
    nFacility Installed
     — Enter yes
     in the B, C, and  D c olumns und er the DS1 
    Converter Fac ilities head ing  to ind ic ate that this DS1 fac ility is p hysic ally 
    installed . At least fac ility A must b e installed  within the c onverter c omp lex. 
    Default is yes
     for Fac ility A.
    nPasses Far-end Clock
     — Enter yes
     in the B, C, and  D c olumns und er 
    the DS1 Converter Fac ilities heading  to ind ic ate that this DS1 fac ility is 
    suitab le to b e used  as a c loc k sourc e. If the DS1 sig nal d oes not c ome 
    d irec tly from the far end c onverter c irc uit pac k or the network (suc h as 
    when the sig nal is c onverted  from d ig ital to analog and  then bac k to 
    digital), enter no
    .”  Default is yes
     for Fac ility A.
    This field  d etermines whether the DS1 c onverter c irc uit p ac k c an use 
    rec eive DS1 sig nal timing  to time the transmit fib er sig nal. This is 
    nec essary for p assing  timing  from a master PN to a slave PN ac ross a 
    Converter Comp lex.
    nDigital Data Compatible
     — Enter yes
     (d efault) in the B, C, and D 
    c olumns und er the DS1 Converter Fac ilities head ing  to ind ic ate that this 
    DS1 fac ility is suitab le for transmission of d ig ital d ata. At least Fac ility A 
    must b e suitab le for transmission of d ig ital d ata. If Customer Premises 
    Eq uip ment that alters d ig ital d ata exists on this fac ility (suc h as with a 
    channel exp ansion multip lexer), enter no
    . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-14 Administer Fiber Links 
    A
    nLine Coding
     — Enter the line c od ing  format, ami-zcs
     (d efault), or 
    ami-basic
    , b8zs
    , or hdb3
     in the A, B, C, and  D c olumns und er the DS1 
    Converter Fac ilities head ing  for eac h DS1 fac ility.
    When ami-zc s line c od ing  is used , all-zero b ytes are p revented  from b eing  
    transmitted  on the DS1 fac ility b ec ause a 1 is arb itrarily written into the 
    sec ond  p osition of eac h b yte. Thus, if no measures are taken to p revent it, 
    ami-zc s line c oding results in data c orruption. The DS1CONV circuit pac k 
    p rotec ts the p ac ket fac ility (one of up to four fac ilities d ynamic ally 
    alloc ated  b y the DS1CONV c irc uit pac k) from c orrup tion throug h a sp ec ial 
    esc ap e mec hanism.
    When b 8zs line c od ing  is used , it maintains DS1 fac ility’s ones-d ensity 
    req uirements by enc od ing  a zero d ata b yte into a sp ec ific  uniq ue p attern 
    of b ip olar violations on the DS1 line. The op p osite end  rec og nizes this 
    p attern and  rep lac es it with a zero d ata b yte when the data is rec overed  at 
    the rec eiving  end .
    NOTE:
    Note that althoug h the esf framing  mod e and  b 8zs line c od ing are 
    the p referab le modes of op eration, you should  c onfirm that the DS1 
    fac ilities sup p ort them b efore selec ting  this line c oding .
    nFraming Mode
     — Enter the framing  format, esf
     (d efault) or d4
    , in the A, 
    B, C, and D c olumns und er the DS1 Converter Fac ilities head ing  for eac h 
    DS1 fac ility.
    NOTE:
    The D4 format is sup p orted by the Converter c irc uit p ac ks, b ut 
    b ec ause of p rob lems inherent with this format (sp ec ific ally, inability 
    to frame on a b it stream that c ontains d ata that emulates the D4 
    framing pattern), its use is d isc ourag ed .
    nDS1CONV-1 Line Compensation
     — Enter the line c omp ensation (1
     to 5
    ) 
    in the A, B, C, and  D c olumns und er the DS1 Converter Fac ilities head ing  
    for eac h DS1 fac ility c onnec ted to ENDPOINT-1 (see Table 6-15
    ).
    The DS1 line sig nal is p re-eq ualized  at the transmitter so that DS1 line 
    p ulses are the c orrec t amp litud e and  shap e when they reac h the Network 
    Interfac e. The amount of eq ualization nec essary is d etermined  b y the 
    d istanc e to the Network Interfac e (when the end p oint supp lies a DSX-1 
    interfac e) and  also b y the typ e of wiring  used  to c onnec t to the Network 
    Interfac e. The typ es of wiring  allowed  are 22 g aug e ABAM (shield ed  
    twisted  p air) c ab le, 24 g aug e Premises Distrib ution System (PDS) wiring, 
    and  26 g aug e PDS wiring . 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-15 Administer Fiber Links 
    A
    NOTE:
    The line eq ualization setting  d efaults to 2 and  remains in effec t until 
    c hang ed by administration. Bec ause inc orrec t eq ualizer settings 
    c ause a p otentially hig her error rate on the DS1 fac ility, it is 
    nec essary to p rovid e the c orrec t setting s b ased  on the d istanc e to 
    the Network interfac e.
    If it is a TN574 c irc uit p ac k, the default for all fac ilities is 1
    .
    nDS1CONV-2 Line Compensation
     — Enter the line c omp ensation (1
     to 5
    ) 
    in the A, B, C, and  D c olumns und er the DS1 Converter Fac ilities head ing  
    for eac h DS1 fac ility c onnec ted  to ENDPOINT-2 (see Tab le 6-15
    ). The DS1 
    line sig nal is p re-equalized  at the transmitter so that DS1 line p ulses are 
    the c orrec t amp litud e and  shape when they reac h the Network Interfac e. 
    The amount of eq ualization nec essary is d etermined  b y the d istanc e to 
    the Network Interfac e (when the end point sup p lies a DSX-1 interfac e) and  
    also b y the typ e of wiring  used to c onnec t to the Network Interfac e. The 
    types of wiring  allowed  are 22-gaug e ABAM (shield ed  twisted  p air) c ab le, 
    24-g aug e Premises Distrib ution System (PDS) wiring , and  26-g aug e PDS 
    wiring .
    nFacility A Circuit ID — Disp lays when the value in Facility 
    Installed
     for Fac ility A is yes
    . Enter up to 40 c harac ters to id entify the 
    c ab inet, c arrier, and  slot of the DS1 Converter c irc uit p ac k’s p hysic al 
    loc ation. 
    Similarly, Fac ility B Circ uit ID, Fac ility C Circ uit ID, and  Fac ility D Circ uit ID 
    field s display for eac h of the DS1 Converter Fac ilities when yes
     is entered  
    in the c orresp ond ing  Fac ility Installed  field .
    Table 6-15. Distance to DSX-1 Interface (feet 
    Equalizer 
    Setting 22 AWG ABAM & 24 AWG PDS 26 AWG PDS
    1   1 to 133  0 to 90
    2 133 to 266  90 to 180
    3 266 to 399 180 to 270
    4 399 to 533 270 to 360
    5 533 to 655 360 to 450
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-16 Administer Fiber Links 
    A
    Duplicated DS1C Converter Complex Administration
    for TN574 Circuit Packs. 
    Screen 6-4. Fiber Link Administration form for TN574 Circuit Pack (Duplicated DS1 
    Converter Complex Administration) (page 3 of 3)
    Pag e 3 ap p ears when the Is one end p oint remoted  via a DS1 Converter Comp lex 
    field  is yes
     and d up lic ation is enab led .
    NOTE:
    When you ad minister DS1 Converter TN1654 c irc uit p ac ks, d ifferent field s 
    display.
    For field  d efinitions of the field s d isp layed  on p ag e 3 of the Fib er Link 
    Ad ministration form, refer b ac k to the p revious sec tion.
    add fiber-link next  Page 3 of 3
     FIBER LINK ADMINISTRATION
    B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
    DS1CONV Board Location: 01C01  DS1CONV Board Location: 02C01
    DS1CONV Board Type: TN574  DS1CONV Board Type: TN574
    DS1 CONVERTER FACILITIES
      ABC D
             Facility Installed? yes  no  no  no
           Passes Far-end Clock? yes  yes  yes  yes
        Digital Data Compatible? yes  yes  yes  yes
                    Line Coding: ami-zcs  ami-zcs ami-zcs ami-zcs
                   Framing Mode: esf esf esf esf
    DS1CONV-1 Line Compensation: 1 1 1 1
    DS1CONV-2 Line Compensation: 1 1 1 1
    Facility B Circuit ID: 01112343 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-17 Administer Fiber Links 
    A
    DS1 Converter Complex Administration for T1 TN1654 Circuit Packs. 
    Screen 6-5. Fiber Link Administration form for T1 TN1654 Circuit Pack (DS1 Converter 
    Complex Administration) (page 2 of 3) 
    The following uniq ue field s display when administering  a T1 TN1654 DS1 
    Converter.
    nBit Rate — Disp lays when the DS1 Converter c irc uit pac k is TN1654. 
    Enter either 1.544
     for d omestic  T1 op eration or 2.048
     for international E1 
    op eration. 
    NOTE:
    Sinc e one b it rate ap p lies for all fac ilities within the same DS1 
    Converter c omp lex, the Bit Rate
     field  d isp lays only und er 
    Fa c i l i t y A .
    nFacility Startup Idle Code— Disp lays when the DS1 Converter c irc uit 
    p ac k is TN1654. Enter 8 dig its, eac h d ig it must b e 0
     or 1
    . The sec ond  d ig it 
    must b e 1
    . Default is 11101000
    . You c an ad minister this field  on a p er 
    c irc uit p ac k basis. This is the id le c od e used when a TN1654 first 
    estab lishes a link on a T1/E1 fac ility. The initial id le c od e used  b y the 
    TN1654 is overwritten b y the c enter stag e switc h to an “ all ones”  p attern 
    onc e framing is estab lished  on that T1/E1 fac ility.
    nFraming Mode
     — For TN1654 with 1.544 Mb p s Bit Rate, this is a 
    d isp lay-only field .
    add fiber-link next  Page 2 of 3
     FIBER LINK ADMINISTRATION
    A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
    DS1CONV Board Location: 01B01  DS1CONV Board Location: 02B01
    DS1CONV Board Type: TN1654  DS1CONV Board Type: TN1654
    DS1 CONVERTER FACILITIES
      ABC D
             Facility Installed? yes  yes  no  no
    Bit Rate: 1.544
    Facility Startup Idle Code: 11101000
                    Line Coding: ami-zcs  ami-zcs ami-zcs ami-zcs
                   Framing Mode:
    DS1CONV-1 Line Compensation: 1 1 1 1
    DS1CONV-2 Line Compensation: 1 1 1 1
    Facility A Circuit ID: 09876543
    Facility B Circuit ID: 234567889 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-18 Administer Fiber Links 
    A
    Duplicated DS1 Converter Complex Administration for T1 TN1654 Circuit 
    Packs. 
    Screen 6-6. Fiber Link Administration form for E1 TN1654 Circuit Pack (DS1 Converter 
    Complex Administration) (page 2 of 3) 
    The following uniq ue field s d isplay when administering  a TN1654 DS1 Converter.
    nBit Rate — A d isp lay-only field  for TN1654 entered  on p ag e 3 of the form. 
    See p revious sec tion. 1.544
     ind ic ates d omestic  T1 op eration and  2.048
     
    indic ates international E1 op eration.
    DS1 Converter Complex Administration for E1 TN1654 Circuit Packs . 
    The following uniq ue field s display when administering  a E1 TN1654 DS1 
    Converter.
    nBit Rate — Disp lays when the DS1 Converter c irc uit pac k is TN1654. 
    Enter either 1.544
     for d omestic  T1 op eration or 2.048
     for international E1 
    op eration.
    NOTE:
    Sinc e one b it rate ap p lies for all fac ilities within the same DS1 
    Converter c omp lex, Bit Rate
     d isp lays only und er Fac ility A. To 
    ac tivate the d esired  Bit Rate, the tog g le switc h on the c irc uit p ac k 
    must b e set and  it must c orresp ond to the Bit Rate.
    nIdle Code MSB(1) ... LSB(8) — Disp lays when the DS1 Converter c irc uit 
    p ac k is TN1654. Enter 8 dig its, eac h d ig it must b e 0
     or 1
    . The sec ond  d ig it 
    must b e 1
    . Default is 11101000
    . You c an ad minister this field  on a p er 
    circuit pack basis.
    add fiber-link next  Page 2 of 3
     FIBER LINK ADMINISTRATION
    A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
    DS1CONV Board Location: 01B01  DS1CONV Board Location: 02B01
    DS1CONV Board Type: TN1654  DS1CONV Board Type: TN1654
    DS1 CONVERTER FACILITIES
      ABC D
             Facility Installed? yes  yes  yes  no
    Bit Rate: 2.048
    Facility Startup Idle Code: 11101000
                    Line Coding: hdb3 hdb3 hdb3 hdb3
    CRC? yes
    Line Termination:
    Facility A Circuit ID: 09876543
    Facility B Circuit ID: 234567889
    Facility C Circuit ID: 434566335 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-19 Administer Fiber Links 
    A
    nCRC — Disp lays when the DS1 Converter c irc uit p ac k is TN1654 and  the 
    Bit Rate is 2.048 Mb p s. Enter yes
     to rec eive a “ yellow 2”  alarm for E1 
    op eration. Default is no
    . You c an ad minister this field  on a p er c irc uit p ac k 
    b asis.
    nLine Termination
     — A d isp lay-only field  for DS1 Converter c irc uit p acks 
    that are TN1654 and  have a Bit Rate of 2.048 Mb p s. It id entifies fac ility 
    c onnec tions as CEPT 75 ohm c oaxial or 120 ohm CEPT twisted  p air.
    Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit 
    Packs. 
    See the p revious sec tions for sc reen layout and  field  d efinitions.
    Screen 6-7. Fiber Line Administration form for B-PNC DS1 Converter 
    (DS1CONV) Attributes
    add fiber-link next  Page 3 of 3
     FIBER LINK ADMINISTRATION
    B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
    DS1CONV Board Location: 01C01  DS1CONV Board Location: 02C01
    DS1CONV Board Type: TN1654  DS1CONV Board Type: TN1654
    DS1 CONVERTER FACILITIES
      ABC D
             Facility Installed? yes  yes  yes  no
    Bit Rate: 2.048
    Facility Startup Idle Code: 11101000
                    Line Coding: hdb3 hdb3 hdb3 hdb3
    CRC? yes
    Line Termination:
    Facility A Circuit ID: 0AABB01
    Facility B Circuit ID: 0CCDD02
    Facility C Circuit ID: 0EEFF03 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Fiber Link Administration 
    A-20 Administer Fiber Links 
    A 
    						