Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-11 Administer Fiber Links A Duplicated Fiber Link Administration. Screen 6-2. Fiber Link Administration form (page 1 of 3) The following fields appear when Administration of PNC Duplication is enab led on the System-Parameters Customer-Op tions form: nFiber Link # — Disp lay-only field . From the c ommand line, enter a 1- to 3-d ig it numb er to uniq uely id entify a switc h c onnec tion in the system and its d up lic ate if ap prop riate. nIs one endpoint remoted via DS1 Converter Complex? — En t e r yes to sp ec ify that a DS1 c onverter c omp lex is used to remote one end p oint. If yes is entered , A-PNC and B-PNC DS1 Converter (DS1CONV) Attrib utes must b e ad ministered on Pag es 2 and 3 (resp ec tively) of the form. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of a c irc uit pac k in the first end p oint of the d up lic ate fib er link. End p oint-1’s d up lic ate along with End p oint-2’s d up lic ate make up the d up lic ate fib er link c alled the B-PNC link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in End p oint-1. The c irc uit p ac k typ e in Endp oint-1 (A-PNC) and End p oint-1 (B-PNC) must be the same. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of DS1 Converter c irc uit p ac k in the first endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with End p oint-2’s d uplic ate make up the d up lic ate fib er link c alled the B-PNC link. add fiber-link next Page 1 of 3 FIBER LINK ADMINISTRATION Fiber Link #: 1 Is one endpoint remoted via DS1 Converter Complex? yes ENDPOINT-1 ENDPOINT-2 (A-PNC) (A-PNC) Board Location: 01E01 Board Location: 02A01 Board Type: ei Board Type: ei DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574 ENDPOINT-1 ENDPOINT-2 (B-PNC) (B-PNC) Board Location: 01D01 Board Location: 02A02 Board Type: ei Board Type: ei DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-12 Administer Fiber Links A nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k in End p oint-1. The c irc uit p ac k typ e in Endp oint-1 (A-PNC) and End p oint-1 (B-PNC) must b e the same. This field is upd ated via the Chang e Circ uit-pac ks c ommand. nBoard Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of a c irc uit p ac k in the sec ond end p oint of the d up lic ate fiber link. Endpoint-2’s duplicate along with Endpoint-1’s duplicate make up the d up lic ate fib er link c alled the B-PNC link. nBoard Type — Disp lay-only field showing the typ e of c irc uit p ac k in End p oint-2. The c irc uit p ac k typ e in Endp oint-2 (A-PNC) and End p oint-2 (B-PNC) must be the same. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of DS1 Converter c irc uit pac k in the sec ond endpoint of the duplicate fiber link. Endpoint-2’s duplicate along with End p oint-1’s d uplic ate make up the d up lic ate fib er link c alled the B-PNC link. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k in End p oint-2. The c irc uit p ac k typ e in Endp oint-2 (A-PNC) and End p oint-2 (B-PNC) must b e the same. This field is upd ated via the Chang e Circ uit-pac ks c ommand. DS1C Converter Complex Administration for TN574 Circuit Packs. Screen 6-3. Fiber Link Administration form for TN574 Circuit Pack (DS1 Converter Complex Administration) (page 2 of 3) add fiber-link next Page 2 of 3 FIBER LINK ADMINISTRATION A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes no no no Passes Far-end Clock? yes yes yes yes Digital Data Compatible? yes yes yes yes Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs Framing Mode: esf esf esf esf DS1CONV-1 Line Compensation: 1 1 1 1 DS1CONV-2 Line Compensation: 1 1 1 1 Facility A Circuit ID: 09876543
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-13 Administer Fiber Links A The following DS1 Converter Comp lex field s ap p ear on Pag e 2 when the Is one endpoint remoted via a DS1 Converter Complex field is y . NOTE: When you ad minister DS1 Converter TN1654 c irc uit p ac ks, d ifferent field s display. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of the c onverter c irc uit p ac k c onnec ted to the first end point of the fib er link. This is entered on Pag e 1 and d isp lays on Pag e 2. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k for the first end p oint. nDS1CONV Board Location — Enter the c ab inet, c arrier, and slot that id entifies the p hysic al loc ation of the c onverter c irc uit p ac k c onnec ted to the sec ond end p oint of the fib er link. nDS1CONV Board Type — Disp lay-only field showing the type of DS1 Converter c irc uit pac k for the sec ond end point. This field is up d ated via the Chang e Circ uit-p ac ks c ommand . nFacility Installed — Enter yes in the B, C, and D c olumns und er the DS1 Converter Fac ilities head ing to ind ic ate that this DS1 fac ility is p hysic ally installed . At least fac ility A must b e installed within the c onverter c omp lex. Default is yes for Fac ility A. nPasses Far-end Clock — Enter yes in the B, C, and D c olumns und er the DS1 Converter Fac ilities heading to ind ic ate that this DS1 fac ility is suitab le to b e used as a c loc k sourc e. If the DS1 sig nal d oes not c ome d irec tly from the far end c onverter c irc uit pac k or the network (suc h as when the sig nal is c onverted from d ig ital to analog and then bac k to digital), enter no .” Default is yes for Fac ility A. This field d etermines whether the DS1 c onverter c irc uit p ac k c an use rec eive DS1 sig nal timing to time the transmit fib er sig nal. This is nec essary for p assing timing from a master PN to a slave PN ac ross a Converter Comp lex. nDigital Data Compatible — Enter yes (d efault) in the B, C, and D c olumns und er the DS1 Converter Fac ilities head ing to ind ic ate that this DS1 fac ility is suitab le for transmission of d ig ital d ata. At least Fac ility A must b e suitab le for transmission of d ig ital d ata. If Customer Premises Eq uip ment that alters d ig ital d ata exists on this fac ility (suc h as with a channel exp ansion multip lexer), enter no .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-14 Administer Fiber Links A nLine Coding — Enter the line c od ing format, ami-zcs (d efault), or ami-basic , b8zs , or hdb3 in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility. When ami-zc s line c od ing is used , all-zero b ytes are p revented from b eing transmitted on the DS1 fac ility b ec ause a 1 is arb itrarily written into the sec ond p osition of eac h b yte. Thus, if no measures are taken to p revent it, ami-zc s line c oding results in data c orruption. The DS1CONV circuit pac k p rotec ts the p ac ket fac ility (one of up to four fac ilities d ynamic ally alloc ated b y the DS1CONV c irc uit pac k) from c orrup tion throug h a sp ec ial esc ap e mec hanism. When b 8zs line c od ing is used , it maintains DS1 fac ility’s ones-d ensity req uirements by enc od ing a zero d ata b yte into a sp ec ific uniq ue p attern of b ip olar violations on the DS1 line. The op p osite end rec og nizes this p attern and rep lac es it with a zero d ata b yte when the data is rec overed at the rec eiving end . NOTE: Note that althoug h the esf framing mod e and b 8zs line c od ing are the p referab le modes of op eration, you should c onfirm that the DS1 fac ilities sup p ort them b efore selec ting this line c oding . nFraming Mode — Enter the framing format, esf (d efault) or d4 , in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility. NOTE: The D4 format is sup p orted by the Converter c irc uit p ac ks, b ut b ec ause of p rob lems inherent with this format (sp ec ific ally, inability to frame on a b it stream that c ontains d ata that emulates the D4 framing pattern), its use is d isc ourag ed . nDS1CONV-1 Line Compensation — Enter the line c omp ensation (1 to 5 ) in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility c onnec ted to ENDPOINT-1 (see Table 6-15 ). The DS1 line sig nal is p re-eq ualized at the transmitter so that DS1 line p ulses are the c orrec t amp litud e and shap e when they reac h the Network Interfac e. The amount of eq ualization nec essary is d etermined b y the d istanc e to the Network Interfac e (when the end p oint supp lies a DSX-1 interfac e) and also b y the typ e of wiring used to c onnec t to the Network Interfac e. The typ es of wiring allowed are 22 g aug e ABAM (shield ed twisted p air) c ab le, 24 g aug e Premises Distrib ution System (PDS) wiring, and 26 g aug e PDS wiring .
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-15 Administer Fiber Links A NOTE: The line eq ualization setting d efaults to 2 and remains in effec t until c hang ed by administration. Bec ause inc orrec t eq ualizer settings c ause a p otentially hig her error rate on the DS1 fac ility, it is nec essary to p rovid e the c orrec t setting s b ased on the d istanc e to the Network interfac e. If it is a TN574 c irc uit p ac k, the default for all fac ilities is 1 . nDS1CONV-2 Line Compensation — Enter the line c omp ensation (1 to 5 ) in the A, B, C, and D c olumns und er the DS1 Converter Fac ilities head ing for eac h DS1 fac ility c onnec ted to ENDPOINT-2 (see Tab le 6-15 ). The DS1 line sig nal is p re-equalized at the transmitter so that DS1 line p ulses are the c orrec t amp litud e and shape when they reac h the Network Interfac e. The amount of eq ualization nec essary is d etermined b y the d istanc e to the Network Interfac e (when the end point sup p lies a DSX-1 interfac e) and also b y the typ e of wiring used to c onnec t to the Network Interfac e. The types of wiring allowed are 22-gaug e ABAM (shield ed twisted p air) c ab le, 24-g aug e Premises Distrib ution System (PDS) wiring , and 26-g aug e PDS wiring . nFacility A Circuit ID — Disp lays when the value in Facility Installed for Fac ility A is yes . Enter up to 40 c harac ters to id entify the c ab inet, c arrier, and slot of the DS1 Converter c irc uit p ac k’s p hysic al loc ation. Similarly, Fac ility B Circ uit ID, Fac ility C Circ uit ID, and Fac ility D Circ uit ID field s display for eac h of the DS1 Converter Fac ilities when yes is entered in the c orresp ond ing Fac ility Installed field . Table 6-15. Distance to DSX-1 Interface (feet Equalizer Setting 22 AWG ABAM & 24 AWG PDS 26 AWG PDS 1 1 to 133 0 to 90 2 133 to 266 90 to 180 3 266 to 399 180 to 270 4 399 to 533 270 to 360 5 533 to 655 360 to 450 Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-16 Administer Fiber Links A Duplicated DS1C Converter Complex Administration for TN574 Circuit Packs. Screen 6-4. Fiber Link Administration form for TN574 Circuit Pack (Duplicated DS1 Converter Complex Administration) (page 3 of 3) Pag e 3 ap p ears when the Is one end p oint remoted via a DS1 Converter Comp lex field is yes and d up lic ation is enab led . NOTE: When you ad minister DS1 Converter TN1654 c irc uit p ac ks, d ifferent field s display. For field d efinitions of the field s d isp layed on p ag e 3 of the Fib er Link Ad ministration form, refer b ac k to the p revious sec tion. add fiber-link next Page 3 of 3 FIBER LINK ADMINISTRATION B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01 DS1CONV Board Type: TN574 DS1CONV Board Type: TN574 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes no no no Passes Far-end Clock? yes yes yes yes Digital Data Compatible? yes yes yes yes Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs Framing Mode: esf esf esf esf DS1CONV-1 Line Compensation: 1 1 1 1 DS1CONV-2 Line Compensation: 1 1 1 1 Facility B Circuit ID: 01112343
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-17 Administer Fiber Links A DS1 Converter Complex Administration for T1 TN1654 Circuit Packs. Screen 6-5. Fiber Link Administration form for T1 TN1654 Circuit Pack (DS1 Converter Complex Administration) (page 2 of 3) The following uniq ue field s display when administering a T1 TN1654 DS1 Converter. nBit Rate — Disp lays when the DS1 Converter c irc uit pac k is TN1654. Enter either 1.544 for d omestic T1 op eration or 2.048 for international E1 op eration. NOTE: Sinc e one b it rate ap p lies for all fac ilities within the same DS1 Converter c omp lex, the Bit Rate field d isp lays only und er Fa c i l i t y A . nFacility Startup Idle Code— Disp lays when the DS1 Converter c irc uit p ac k is TN1654. Enter 8 dig its, eac h d ig it must b e 0 or 1 . The sec ond d ig it must b e 1 . Default is 11101000 . You c an ad minister this field on a p er c irc uit p ac k basis. This is the id le c od e used when a TN1654 first estab lishes a link on a T1/E1 fac ility. The initial id le c od e used b y the TN1654 is overwritten b y the c enter stag e switc h to an “ all ones” p attern onc e framing is estab lished on that T1/E1 fac ility. nFraming Mode — For TN1654 with 1.544 Mb p s Bit Rate, this is a d isp lay-only field . add fiber-link next Page 2 of 3 FIBER LINK ADMINISTRATION A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01 DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes yes no no Bit Rate: 1.544 Facility Startup Idle Code: 11101000 Line Coding: ami-zcs ami-zcs ami-zcs ami-zcs Framing Mode: DS1CONV-1 Line Compensation: 1 1 1 1 DS1CONV-2 Line Compensation: 1 1 1 1 Facility A Circuit ID: 09876543 Facility B Circuit ID: 234567889
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-18 Administer Fiber Links A Duplicated DS1 Converter Complex Administration for T1 TN1654 Circuit Packs. Screen 6-6. Fiber Link Administration form for E1 TN1654 Circuit Pack (DS1 Converter Complex Administration) (page 2 of 3) The following uniq ue field s d isplay when administering a TN1654 DS1 Converter. nBit Rate — A d isp lay-only field for TN1654 entered on p ag e 3 of the form. See p revious sec tion. 1.544 ind ic ates d omestic T1 op eration and 2.048 indic ates international E1 op eration. DS1 Converter Complex Administration for E1 TN1654 Circuit Packs . The following uniq ue field s display when administering a E1 TN1654 DS1 Converter. nBit Rate — Disp lays when the DS1 Converter c irc uit pac k is TN1654. Enter either 1.544 for d omestic T1 op eration or 2.048 for international E1 op eration. NOTE: Sinc e one b it rate ap p lies for all fac ilities within the same DS1 Converter c omp lex, Bit Rate d isp lays only und er Fac ility A. To ac tivate the d esired Bit Rate, the tog g le switc h on the c irc uit p ac k must b e set and it must c orresp ond to the Bit Rate. nIdle Code MSB(1) ... LSB(8) — Disp lays when the DS1 Converter c irc uit p ac k is TN1654. Enter 8 dig its, eac h d ig it must b e 0 or 1 . The sec ond d ig it must b e 1 . Default is 11101000 . You c an ad minister this field on a p er circuit pack basis. add fiber-link next Page 2 of 3 FIBER LINK ADMINISTRATION A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01B01 DS1CONV Board Location: 02B01 DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes yes yes no Bit Rate: 2.048 Facility Startup Idle Code: 11101000 Line Coding: hdb3 hdb3 hdb3 hdb3 CRC? yes Line Termination: Facility A Circuit ID: 09876543 Facility B Circuit ID: 234567889 Facility C Circuit ID: 434566335
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-19 Administer Fiber Links A nCRC — Disp lays when the DS1 Converter c irc uit p ac k is TN1654 and the Bit Rate is 2.048 Mb p s. Enter yes to rec eive a “ yellow 2” alarm for E1 op eration. Default is no . You c an ad minister this field on a p er c irc uit p ac k b asis. nLine Termination — A d isp lay-only field for DS1 Converter c irc uit p acks that are TN1654 and have a Bit Rate of 2.048 Mb p s. It id entifies fac ility c onnec tions as CEPT 75 ohm c oaxial or 120 ohm CEPT twisted p air. Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit Packs. See the p revious sec tions for sc reen layout and field d efinitions. Screen 6-7. Fiber Line Administration form for B-PNC DS1 Converter (DS1CONV) Attributes add fiber-link next Page 3 of 3 FIBER LINK ADMINISTRATION B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES DS1CONV Board Location: 01C01 DS1CONV Board Location: 02C01 DS1CONV Board Type: TN1654 DS1CONV Board Type: TN1654 DS1 CONVERTER FACILITIES ABC D Facility Installed? yes yes yes no Bit Rate: 2.048 Facility Startup Idle Code: 11101000 Line Coding: hdb3 hdb3 hdb3 hdb3 CRC? yes Line Termination: Facility A Circuit ID: 0AABB01 Facility B Circuit ID: 0CCDD02 Facility C Circuit ID: 0EEFF03
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Fiber Link Administration A-20 Administer Fiber Links A