Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-83 Critical Reliability 5 Figure 5-24. Location of P1 and P2 Connectors Prepare the New A and B Position Carriers 1. Insp ec t the new c arriers for any d amag e. Verify that the b ac kp lane pins are not b ent. 2. Plac e the exp ansion c ontrol c arrier on the floor so that the rear of the carrier faces up. 3.Install the CFY1 c urrent limiter (CURL) on the “ A” c arrier to the p in-field b loc k marked “ CURL.” The CURL is inserted with the c omponents on the left sid e as viewed from the rear. 4. At the rear c onnec tor p anel, d etermine whic h c onnec tors will have a c ab le attac hed , and install a 4B c ab le retainer on eac h of these c onnec tors. Figure Notes 1. Rear of Control Carrier 2. P2 Connec tor3. P1 Connec tor
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-84 Critical Reliability 5 Install the New A and B Position Carriers 1.Install the J58890AF Exp ansion Control Carrier in p osition “ A” b y lining up the p lastic alig nment tip s on the top rear of the c arrier with the sc rew holes in the c ab inet. These alig nment tip s will sup port the c arrier while the sc rews are b eing rep lac ed . Ensure that the p ower c ords are p rop erly p lac ed in the slots at the sid es of the c arrier. 2. Fasten the c arrier into p osition with 4 self-tap p ing sc rews saved from the removal of the old c arrier. !CAUTION: Carefully realig n the thread s on the self-tap ping sc rews b y turning them c ounterc loc kwise 1 turn b efore tig htening them to avoid stripping the threads out of the framework. 3. Behind the carrier in a “DEFINITY style” c abinet, replace the 2 sc rews saved from the removal of the old c arrier. 4. Install the J58890BB-3 p ort c arrier in p osition “ B” b y lining up the p lastic alig nment tip s on the top rear of the c arrier with the sc rew holes in the c ab inet. These alig nment tip s sup p ort the c arrier while the sc rews are b eing rep lac ed . Ensure the p ower c ords are p rop erly p lac ed in the slots at the sid es of the c arrier. 5. Fasten the c arrier into p osition with 4 self-tap p ing sc rews saved from the removal of the old c arrier. 6. Connec t the “ P2” and “ P1” (larg e and small) c onnec tors to the “ A” c arrier. Snap the c onnec tor loc k into p lac e to ensure the c onnec tion is p rop erly mad e. See Figure 5-25 . 7. Connec t the “ P1” (small) c onnec tor to the “ B” c arrier. To g et enoug h slac k in the c ab les, c ut the tie wrap hold ing the interc ab inet c ab les from the up rig ht in the area of the c arrier b eing installed. Snap the c onnec tor loc k into p lac e to ensure the c onnec tion is p rop erly mad e. 8. Connec t the 8 g round strap s from the “ D” c arrier to the new “ A” c arrier. See Figure 5-24 . These straps were left c onnec ted to the “ D” c arrier. 9. Connec t the 8 g round strap s from the “ C” c arrier to the new “ B” c arrier. These strap s were left c onnec ted to the “ C” c arrier. 10. Install the 8 g round strap s between the new “ A” and “ B” c arriers. These strap s were removed from the old c arriers. 11. For an AC-p owered exp ansion c ontrol c arrier, install the 2 new c arrier g round strap s. One strap c onnec ts g round p oint “ 1” to the A-c arrier frame (on the rig ht side), and the other c onnec ts g round p oint “ 8” to the A-c arrier frame (on the left sid e). NOTE: DC-p owered c arriers d o not use these c arrier g round strap s.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-85 Critical Reliability 5 12.Connec t the loose end of the TDM/LAN c ab le (b etween the “ A” and “ D” c arriers) to the p in-field b loc k marked “ TDM” on the rig ht sid e of the “ A” c arrier (see Figure 5-26 and Table 5-15). The other end remained c onnec ted to the “ D” c arrier when the old c arrier was removed . 13. Connec t the loose end of the TDM/LAN c ab le (b etween the “ B” and “ C” c arriers) to the p in-field b loc k marked “ TDM” on the rig ht sid e of the “ B” c arrier. The other end remained c onnec ted to the “ C” c arrier when the old carrier was removed . 14. Install the TDM/LAN c ab le b etween the “ A” and “ B” c arriers. The c ab le is c onnec ted to the “ A” and “ B” c arriers at the p in-field b loc ks marked “ TDM” on the left sid e of eac h c arrier. 15. On p ort c arrier J58890BB-1, c onnec t the TDM c ab le or the TDM terminator to Slot 02. On p ort c arriers J58890BB-2 and J58890BB-3, c onnec t the TDM c ab les or the TDM terminator to Slot 01. If the port c arrier has J58890BB-1 and J58890BB-2 p rinted on it, treat it as a J58890BB-1. Table 5-15. TDM/LAN Connections J Number Carrier Type LHS Slot RHS Slot J58890BB-1 Port 21 02 J58890BB-2 Port 21 01 J58890BB-3 Port 21 01 J58890AF EPN Control “ A” 21 02
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-86 Critical Reliability 5 Figure 5-25. TDM/LAN Connections for Critical Reliability Release 8 EPN Figure Notes 1. ZAHF4 TDM/LAN Terminator 2. TDM/LAN Cab le (WP91716 L6) 3. Slot 21 4.Inter-Carrier Cables (“A” and “B”) H600-204, G15. Slot 02 6. TDM/LAN Cable (WP91716 L7) 7. ICCA and ICCB Connec tors)
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-87 Critical Reliability 5 16.Install the front trim p lates; first on the “ A” c arrier, and then on the “ B” carrier. 17. Install the ICC c ab les (H600-204 G1) b etween c arriers “ A” and “ B.” Connec t the c ab les to the “ ICC” p in-field b loc k on b oth c arriers (see Figure 5-27 and Figure 5-28 and Table 5-16). Install the c able so that the d ark stripe is on the b ottom at b oth end s. !CAUTION: While installing the ICC c ab le c onnec tors, be c areful not to b end any b ac kp lane p ins. Doub le c hec k eac h c onnec tion to verify that the p ins are straig ht. 18. Install the p ower units (removed from G2 universal module) into the “ A” c arrier. There are 4 d ifferent p airs of p ower units availab le. They are the 631AR1 and 631BR1, the 631WA1 and 631WB1, the 631DA1 and 631DB1, and the 644A and 645B. Do not interc hang e the p hysic al loc ations of the units. Install the 631AR1, 631WA1, 631DA1 or 644A in the left sid e. Install the 631BR1, 631WB1, 631DB1 or 645B in the rig ht sid e. 19. If the exp ansion c ontrol c arrier c ontains a 631BR1, 631WB1, or 645B p ower unit, install the p reviously removed TN736 p ower unit in p ort slots “ 18” and “ 19” of the c arrier (ad jac ent to the 631BR1, 631WB1, or 645B). If the system c ontains neon messag e waiting , a TN752 or TN755 p ower unit must b e used . NOTE: The TN736 is not required when the 631DB1 or 645B p ower unit is used in the J58890AH c ontrol c arrier or the J58890BB-2 or J58890BB-3 p ort c arriers. It is req uired in the J58890BB-1 p ort c arrier reg ard less of whic h 631 p ower unit is p rovid ed . Use the TN752 or TN755 if the system is eq uip p ed with neon messag e waiting . 20. Connec t the p ower c ord s to the p ower units. The p ower c ords are the white c ab les eq uip p ed with p lug s that are run throug h the slots in the front of each carrier.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-88 Critical Reliability 5 Figure 5-26. ICC Connections for the Expansion Control Carrier Table 5-16. Intercarrier Cable Connections Connect ICC Cables From To Carrier Pin-Field Bloc k Carrier Pin-Field Bloc k EPN J58890AF ICCA ICCBJ58890BB ICCA ICCB Figure Notes 1. ICCA Connec tors 2. ICCB Connec tors3. CURL (Current Limiter) Connec tors
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-89 Critical Reliability 5 Figure 5-27. ICC Connections for the Port Carrier Figure Notes 1. ICCA Connec tors 2. ICCB Connec tors
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-90 Critical Reliability 5 Test the CURL 1. Plug the c ab inet p ower c ord into the ap p rop riate rec ep tac le. 2. At the power d istribution unit, set the main c irc uit b reaker to ON. 3.Unp lug the p ower c ord from the p ower unit “ B” (rig ht-hand side) in the “ A” carrier. 4. The fans must b e running . If not, c hec k the installation of the CURL. 5. Rec onnec t the p ower c ord to the power unit in the “ A” c arrier, then unp lug the p ower c ord from p ower unit “ B” (rig ht-hand sid e) in the “ B” c arrier. 6. The fans must b e running . If not, c hec k the installation of the CURL. 7. Rec onnec t the p ower c ord to the p ower unit in the “ B” c arrier. 8. At the power d istribution unit, set the main c irc uit b reaker to OFF. Install Circuit Packs 1. Install the new Release 8 c ontrol c irc uit p ac ks into c arriers “ A” and “ B.” Use the new d ec al and the annotated “ list c onfig uration all” (p rovid ed with the Release 8 translation card) as a guide. NOTE: Currently, b oth TN768 Tone Cloc k c irc uit p ac ks resid e in port slots of the universal mod ule b eing up grad ed . As p art of this step , reloc ate these c irc uit p ac ks to the “ TONE CLOCK” slot of c arrier “ A” and p ort slot “1” of carrier “B.” 2. For a d irec tly-c onnec ted c ritic al reliab ility Release 8 system with 2 p ort networks, ensure that the PPN and this EPN are b oth eq uip p ed with 2 TN776 or TN570 Expansion Interfac e c irc uit p ac ks. For a d irec tly-c onnec ted system with 3 p ort networks, ensure that the PPN and eac h EPN have 4 TN776s or TN570s.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-91 Critical Reliability 5 Interconnect Port Networks — Critical Reliability Fiber op tic c abling terminated to 9823A lig htwave transc eivers c an interc onnec t PNs up to 4,900 feet (1493 m) ap art. Fib er op tic c ab ling terminated to 9823B lig htwave transc eivers c an interc onnec t PNs up to 25,000 feet (7620 m) ap art. NOTE: These d istanc e limits are ap p roximate measurements of the ac tual fib er rig ht-of-way (not of the shortest linear d istanc e) b etween the 2 end points. NOTE: It is imp ortant to lab el every c ab le that you install. NOTE: Keep trac k of whic h fib er attac hes to whic h c onnec tor on eac h lig htwave transc eiver. This sec tion p rovides fig ures offering the sug gested way of making these c onnec tions. The c onnec tors on the lig htwave transc eivers are lab eled either “ TX” (transmit) or “ RX” (rec eive), while the fib ers attac hed to eac h c onnec tor are numb ered either “ 1” or “ 2.” A viab le fib er c onnec tion is only mad e when b oth fibers in eac h c ab le (“ 1” and “ 2” ) route from the “ TX” c onnec tor of a p ort network to the “ RX” c onnec tor of its ad jac ent p ort network. For an examp le, refer to Figure 5-29 on page 5-96 . NOTE: When finished , refer to Appendix A, ‘‘Fiber Link Administration’’ to ad minister the fiber links. Collocated Port Networks For a c ritic al reliab ility system with 1 c olloc ated EPN, use 2 fib er op tic c ables and 4 lig htwave transc eivers to direc tly c onnec t the networks. For a c ritic al reliab ility system with 2 c olloc ated EPNs, use 6 fib er op tic c ab les and 12 lig htwave transc eivers to d irec tly c onnec t the networks. NOTE: Based on floor-p lan c onsid erations, the leng th of these c ab les may vary. Twenty-foot (6.1 m) c ab les are normally ad eq uate for a Release 8 with 2 p ort networks. For collocated cabinets, the fiber optic cables should be routed directly from the PPN t o t h e EPN c ab inet. If a “ DEFINITY style” PPN c abinet is c olloc ated with another “ DEFINITY style” EPN c ab inet, route the c ab les up the c ab le tray and out the top of the PPN c ab inet. The c ab les are then run to the other c abinet, throug h the top of the c ab inet, and down the c ab le tray to the d esired c arrier level. If a “ DEFINITY style” PPN c ab inet is c olloc ated with either a small c ab inet, med ium c ab inet, or sing le-c arrier c ab inet stac k, route the c ab les down the c ab le tray and out the b ottom of the PPN c ab inet. The c ab les are then run to the EPN c ab inet and up the outside of the rear p anels to the d esired c arrier level.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-92 Critical Reliability 5 Fiber-Remoted Port Networks For a c ritic al reliab ility system with 1 fib er-remoted EPN, use 4 fib er op tic c ab les, 4 lig htwave transc eivers, and 4 lig htguid e interc onnec t units (p rovided b y the PSC). For a c ritic al reliab ility system with 2 fib er-remoted EPNs, use 12 fiber op tic c ab les, 12 lig htwave transc eivers, and 12 lig htg uid e interc onnec t units (p rovided b y the PSC). For fib er-remoted c ab inets, route the c ab les down the c ab le tray and out the b ottom of the c ab inet to the MDF to the lig htg uid e interc onnec t units. For Either 1 or 2 Collocated Expansion Port Networks 1. At c ontrol c arrier A of PPN c ab inet 1 (see Figure 5-28 throug h Figure 5-31): nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 1A01. nConnec t a fib er op tic c ab le to the transc eiver just installed . nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 2. Behind control carrier A of EPN c abinet 2: nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 2A01. nConnec t the other end of the fiber c ab le to the transc eiver just installed . nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. nAt the top of the c ab inet, c oil the surp lus fib er op tic c ab le and attac h it to the wall of the c able tray. 3. Behind control carrier B of PPN c abinet 1: nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 1B01. nConnec t a fib er op tic c ab le to the transc eiver just installed . nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. 4. Behind p ort c arrier B of EPN c ab inet 2: nInstall a lig htwave transc eiver on the c ab le c onnec tor at slot 2B02. nConnec t the other end of the fiber c ab le to the transc eiver just installed . nCarefully attac h the fib er op tic c ab le (with c ab le ties) to the wall of the c ab le tray at the b uilt-in c ab le tie p ositions. nAt the top of the c ab inet, c oil the surp lus fib er op tic c ab le and attac h it to the wall of the c able tray.