Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-113 Critical Reliability 5 Save Translations 1. Type save translation and press En te r to g et up g rad ed translations onto d isk. If the translations were c orrup ted d uring the up g rad e, the following error message displays when logging in: !WARNING: Translation c orrup tion d etec ted ; c all Luc ent Tec hnolog ies d istrib utor immed iately. NOTE: Th e save translation c ommand c annot func tion if the translation corruption message appears. See ‘‘Troubleshooting an Upgrade’’ on page B-1. Back Up Disk 1. Type backup disk and p ress En t e r to backup all changed files. 2. Type test stored-data long and press En t e r. This instructs the system to verify the c onsistenc y of the MSS files (on the d isk and removab le med ia). Return Replaced Equipment Return rep lac ed eq uip ment to Luc ent Tec hnolog ies ac c ord ing to the req uirements outlined in: BCS/Material Log istic s, MSL/Attend ed Stoc king Loc ations Method s and Proc ed ures for Basic Material Returns
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Multicarrier G2 Universal Module to R8r EPN 5-114 Critical Reliability 5
Adding or Removing Cabinet Hardware 6-1 Single-Mode Fiber Attenuators 6 DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 6 Adding or Removing Cabinet Hardware This c hapter c ontains information to ad d or remove c ab inet hard ware. To install ad junc t or p erip heral eq uipment, refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation for Ad junc ts and Perip herals . To add fib er optic c ab les to an existing system, refer to DEFINITY Enterp rise Communications Server Release 8 Installation and Test for Multicarrier Cabinets. Single-Mode Fiber Attenuators Attenuators may b e req uired when using sing le-mod e fib er. See the tab le b elow. A d ifferent value attenuator may b e req uired even thoug h the fib er sp an is b etween the same 2 c ab inets (loc al and remote c ab inet). Refer to DEFINITY Enterp rise Communic ations Server Release 8 Installation and Test for Multic arrier Cab inets for detailed fib er attenuator information. 106060718 5 d B attenuator 2 for eac h fib er c onnec tion 106060734 10 dB attenuator 2 for eac h fib er c onnec tion 106061021 15 dB attenuator 2 for eac h fib er c onnec tion
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-2 Add Circuit Packs 6 Add Circuit Packs When installing additional features or equipment, it may be necessary to install ad d itional c irc uit p ac ks. This is a general p roc ed ure to use when ad d ing features or eq uip ment that req uire add ing c irc uit pac ks. 1. Log onto the system and answer y to the Sup p ress Alarm Orig ination q uestion d uring log in. 2. Install the c irc uit p ac k into the c arrier. 3. Log off the system after the ad dition (and any req uired ad ministration) is complete. For information ab out ad ministering c irc uit p ac ks and other eq uip ment, refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-3 List of Circuit Packs 6 List of Circuit Packs Table 6-1 lists the c irc uit p ac ks sorted b y ap p aratus c od e, inc lud ing c irc uit p ac ks used in non-United States installations. Table 6-1. Circuit Packs and Circuit Modules Apparatus Code Name Type 631DA1 AC Power Unit Power 631DB1 AC Power Unit Power 644A1 DC Power Unit Power 645B1 DC Power Unit Power 649A DC Power Unit Power 6 7 6 B/ C D C Po w e r Su p p ly Po w e r 982LS Current Limiter Power CFY1B Current Limiter Power C PP1 M e m o r y Exp a n si o n C o n t r o l ED - 1 E5 4 6 (TN2169) (TN2170) (TN566) (TN567)DEFINITY AUDIX R3 System Port Assemb ly ED - 1 E5 4 6 (TN2208) (TN2170)Call Visor ASAI over the DEFINITY (LAN) Gateway R1Po r t Assemb ly J58890M1 (TN801)CallVisor ASAI/CallVisor PC/LAN over the DEFINITY LAN Gateway R2 Po r t Assemb ly TN417 Auxiliary Trunk Port TN419B Tone-Cloc k Control TN420B/C Tone Detec tor Servic e TN429B/C/D Direc t Inward /Outward Dialing (DIOD) Trunk Port TN433 Sp eec h Synthesizer Servic e TN436B Direc t Inward Dialing Trunk Port TN 4 3 7 Ti e Tr u n k - A u s t r a l i a Po r t Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-4 List of Circuit Packs 6 TN438B Central Offic e Trunk Port TN 4 3 9 Ti e Tr u n k Po r t TN447 Central Offic e Trunk Port TN457 Sp eec h Synthesizer Servic e TN 4 5 8 Ti e Tr u n k- U . K . Po r t TN459B Direc t Inward Dialing Trunk Port TN464C/D/E/F DS1 Interfac e - T1, 24 Channel - E1, 32 Channel Port TN465/B/C Central Offic e Trunk Port TN467 Analog Line Port TN468B Analog Line Port TN479 Analog Line Port TN497 Tie Trunk - Italy Port TN553 Pac ket Data Line Port TN556B/C/D ISDN-BRI 4-Wire S/T-NT Interfac e Port TN570/B/C Exp ansion Interfac e Port TN572 Switc h Nod e Cloc k Control TN573/B Switc h Nod e Interfac e Control TN574 DS1 Converter - T1, 24 Channel Port TN722B DS1 Tie Trunk Port TN725B Sp eec h Synthesizer Servic e TN726/B Data Line Port TN735 MET Line Port TN742 Analog Line Port TN744/B Call Classifier Servic e TN744/C/D Call Classifier - Detec tor Servic e TN746/B Analog Line Port TN747/B Central Offic e Trunk Port TN748/B/C/D Tone Detec tor Servic e Table 6-1. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-5 List of Circuit Packs 6 TN750/B/C Announc ement Servic e TN753/B Direc t Inward Dialing Trunk Port TN754/B/C Dig ital Line 4-Wire DCP Port TN755/B Neon Power Unit Power TN756 Tone Detec tor Servic e TN758 Pooled Mod em Port TN760B/C/D/E Tie Trunk Port TN762/B Hybrid Line Port TN763B/C/D Auxiliary Trunk Port TN765 Proc essor Interfac e Control TN767B/C/D/E DS1 Interfac e - T1, 24 Channel Port TN768 Tone-Clock Control TN769 Analog Line Port TN771/D Maintenanc e/Test Servic e TN773 Processor Control TN775/B/C Maintenanc e Servic e TN776 Exp ansion Interfac e Port TN780 Tone-Clock Control TN786 Processor Control TN786B Proc essor Control TN787F/G/H/J/K Multimed ia Interfac e Servic e TN788B Multimed ia Voic e Cond itioner Servic e TN789 Radio Controller Control TN790/B Proc essor Control TN792 Dup lic ation Interfac e (DUPINT) Control TN793 Analog Line Port TN794 Network Control/Pac ket Interfac e (NetPkt) Control TN796B Proc essor Control Table 6-1. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-6 List of Circuit Packs 6 TN797 Analog CO Trunk and Line Comb o Port TN799 Control-LAN (C-LAN) Port TN802B IP Interfac e Assemb ly Port TNPRI/BRI PRI to BRI Converter Port TN1648/B System Ac c ess/Maintenanc e Control TN1650B 32-MB Memory Control TN1654 DS1 Converter - T1, 24 Channel/E1, 32 Channel Port TN1655 Pac ket Interfac e Control TN1657 Disk Drive Control TN2135 Analog Line Port TN2136 Dig ital Line 2-Wire DCP Port TN2138 Central Offic e Trunk Port TN2139 Direc t Inward Dialing Trunk Port TN2140/B Tie Trunk - Hung ary, Italy Port TN2144 Analog Line Port TN2146 Direc t Inward Dialing Trunk Port TN2147/C Central Offic e Trunk Port TN2149 Analog Line Port TN2180 Analog Line Port TN2181 Dig ital Line 2-Wire DCP Port TN2182/B Tone-Cloc k -Tone Detec tor and Call Classifier Control TN2183 Analog Line Port TN2184 DIOD Trunk Port TN2198 ISDN-BRI 2-Wire U Interfac e Port TN2199 Central Offic e Trunk Port TN2202 Ring Generator Power TN2211 Optic al Drive Control TN2224/B Digital Line, 24-Port, 2-Wire DCP Port Table 6-1. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-7 List of Circuit Packs 6 TN2305 ATM Interfac e (multimod e fib er) Port TN2306 ATM Interfac e (sing le-mod e fib er) Port TN2313 DS1 Interfac e Port UN330B Dup lic ation Interfac e Control UN331B Processor Control UN332/B/C Mass Storage/Network Control Control WP-90510 AC Power Sup p ly (Comp ac t Single-Carrier Cab inet) Power WP-91153 AC Power Sup p ly (Sing le-Carrier Cab inet) Power Table 6-1. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-8 Add the Fiber Optic Cable 6 Add the Fiber Optic Cable This c hapter d etails the installation of the fib er op tic c ab le using the DEFINITY fib er op tic p ass-thru kit for Multic arrier Cabinets (MCC) only. This kit (c omc od e 848029278) p rovid es the eq uip ment nec essary to install the fib er op tic c onnec tors and assoc iated c ab ling . Unpack and Inspect 1. Verify the equipment received. See Figure 6-1. Ac tual eq uip ment may vary in ap p earanc e and may ship in sep arate p ac kag es. 2. See Table 6-2 for a list of p art c omc od es. Figure 6-1. Fiber Pass-Thru Kit Equipment Figure Notes 1. Pass-thru Tool 2. SC-SC Fib er Op tic Ad apter 3. ST-SC Fib er Op tic Ad ap ter 4. Fiber Optic Cable5. Fib er Op tic Cab le Disc onnec t Lab el 6. I/O Connec tor Ad ap ter Brac ket 7. Cable Tie 8. Cable Tie Mount indapkit RPY 012398 1 2 3 4 5 6 7 8