    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 502
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-139 Add MCC Port Carriers 
    6
    Figure 6-55. TDM/LAN Bus Connections for Critical-Reliability EPN
    ICCB
    PORT CARRIER
    PORT CARRIER
    ICCA
    SLOT 02
    ICCBICCACABLES A AND B
    H600-204 G1
    B
    EXPANSIONCONTROL CARRIER
    SLOT 21
    PORT CARRIER
    SLOT 21
    REAR VIEW PORT CARRIER SLOT 21(ZAHF4)
    C
    SLOT 21
    D
    E
    J58890BB
    J58890BB SEE NOTE
    SEE NOTE
    SEE NOTE
    SEE NOTE TDM/LAN BUS TERMINATOR
    NOTE:TDM/LAN CABLE
    WP91716 L6
    TDM/LAN CABLE
    WP91716 L7
    TDM/LAN CABLE
    WP91716 L6
    TDM/LAN CABLE
    WP91716 L6INTERCARRIER
    J58890AF-1
    A
    J58890BB
    TDM/LAN BUS
    TERMINATOR
    ZAHF4
    J58890BB
    ON PORT CARRIER J58890BB-1, CONNECT TDM/LAN CABLE OR TDM/LAN TERMINATOR TO SLOT 02.
    ON PORT CARRIERS J58890BB-2 AND -3, CONNECT THE TDM/LAN CABLE OR TDM/LAN TERMINATOR
    TO SLOT 01.SLOT 21 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-140 Add MCC Port Carriers 
    6
    Table 6-11. TDM/LAN Cable Connections
    “J” Number Carrier Type LHS Slot RHS Slot
    J58890B-1 Port 21 02
    J58890B-2 Port 21 01
    J58890B-3 Port 21 01
    J58890AP PPN Control “A” or “B” 20 03
    J58890AF AC EPN Control “ A” 21 02
    J58890AF DC EPN Control “ A” 21 02 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-141 DEFINITY AUDIX Power Procedures 
    6
    DEFINITY AUDIX Power Procedures
    Power Down the AUDIX System
    A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut 
    d own the DEFINITY AUDIX System p rior to p owering  d own the system.
    1. Log  into the AUDIX System as craft
    . 
    2. Type reset system shutdown
    . Press 
    En te r onc e.
    NOTE:
    Do not p ress En t e r again. This will forc e the AUDIX to shutd own 
    immed iately, d rop p ing  all ac tive c alls on the AUDIX.
    3. The “ SHUTDOWN Comp leted ”  messag e ap p ears when the AUDIX is 
    suc c essfully shutd own. This takes ab out 2 minutes.
    4. The AUDIX System can now b e removed  for service.
    Power Up the AUDIX System
    nIf the AUDIX was removed  from the c ab inet:
    1. Re-install the AUDIX and  allow it to b oot up  automatic ally.
    2. Check for AUDIX System errors.
    nIf the AUDIX remained in the c ab inet b ut p ower was removed  from the 
    c ab inet:
    1. Power up  the c ab inet. The AUDIX reb oots automatic ally.
    2. Check for AUDIX System errors.
    nIf the AUDIX remained in the c ab inet and  the c ab inet was not powered 
    down:
    1. At the AUDIX c onsole, hold  the 
    crtl key and  typ e cc
    .
    2. Type 5
     at the p romp t. In ab out 2 minutes, the AUDIX b oots up .
    3. When the system initialization is c omp lete, log  in as craft
    .
    4. Check for AUDIX System errors. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-142 Installing an Integrated Channel Service Unit (ICSU) Module 
    6
    Installing an Integrated Channel
    Service Unit (ICSU) Module
    The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU 
    mod ule integ rated  with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 
    loop b ac k jac k when testing  the DS1 sp an. 
    Checking for required components
    The integ rated c hannel servic e unit (ICSU) p ac kag e c ontains:
    n120A CSU mod ule
    nCab le H600-383
    4-pair modular cord
    Group  2, 50-Foot (15.2 m) c able (standard )
    nCord  DW8A-DE
    4-p air mod ular c ord  to alarm c ontac ts
    nDS1 c irc uit p ac k
    The b asic  ICSU req uires a TN474E or TN777D or later suffix. The 
    enhanc ed  integ rated  c hannel servic e unit req uires a TN474F or TN777E or 
    later suffix.
    Installing the 120A CSU
    See Figure 6-56.  
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-143 Installing an Integrated Channel Service Unit (ICSU) Module 
    6
    Figure 6-56. 120A Channel Service Unit Module
    !CAUTION:
    Do not p lug  the 120A into any c irc uit p ac k other than a TN474F or TN777E 
    or later release/vintag e. Do not c onnec t the 120A to any interfac e other than 
    a network smart jac k.
    Be sure the DS1 c irc uit p ac k is set for 24-c hannel op eration (1.544 Mb p s). 
    The 120A d oes not op erate with the 32-c hannel interfac e. A switc h on the 
    c irc uit p ac k or ad ministration sets this op tion. 
    !CAUTION:
    Always wear an anti-static  wrist strap when installing  a 120A mod ule. Do 
    not touc h the external alarm c able when it is c onnec ted  to the 120A. Static  
    d isc harg e c an d amag e c onnec tor terminals and  relays. 
    1. Unp lug  the DS1 c irc uit p ac k from its slot.
    2. Install a 4C retainer in the 50-p in p lug  assoc iated  with the DS1 c irc uit p ac k 
    slot.
    3.Plug  the 120A’s 25-p air c onnec tor d irec tly into the p lug  assoc iated  with 
    the DS1 c irc uit p ac k slot. 
    1. Rear of c arrier c ontaining  DS1 c irc uit p ac k
    2. 120A CSU
    3. 4-p air c ord  to network interfac e (H600-383)4. DW8A-DE 4-p air c ord  to alarm c ontac ts (op tional)
    5. To 25-p air c onnec tor on rear of c arrier c ontaining  
    DS1 c irc uit pac k
    16 17 18 19 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01AU X
    icsupic RBP 032896 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-144 Installing an Integrated Channel Service Unit (ICSU) Module 
    6
    4. Sec ure the 4C retainer around  the 120A.
    5. Attac h the sup p lied  H600-383 c able to the 120A and to the network smart 
    jac k. 
    This c ab le is d irec tional. To determine the end  that c onnec ts to the 120A, 
    p erform a c ontinuity test b etween pins 3 and  7. The end  with this 
    c ontinuity is the 120A end . The shield  is g round ed  only at the 120A end .
     Use the c ab le p rovid ed . If c ab ling  other than that p rovided  with the 120A 
    is used , ob serve the following  g uid elines:
    nUse 24-g aug e wire that p rovid es ind ividually shield ed , twisted  p airs 
    for transmit and  rec eive sig nals. Use the c ab le b etween the 
    network interfac e and  the 120A. Ground  the shield s of this c able 
    only at the 120A end to avoid  g round  loop s.
    nCab ling  b etween the network interfac e and  120A c an have no 
    bridge taps.
    nIf using  stand ard  house riser c ab le for c onnec tions b etween the 
    network interfac e and  the 120A, maintain a 100-p air sep aration 
    b etween the rec eive and  transmit twisted  p airs.
    nIf using  stand ard  house riser c ab le for c onnec tions b etween the 
    network interfac e and  the 120A, allow no more than 2 c ross 
    c onnec ts to 110-typ e c ross c onnec t bloc ks.
    nNever use quad  c ab le (untwisted  two pair telep hone c ab le) in a 
    DS1 line.
    nAvoid  mixing  wires of d ifferent g aug es in a DS1 line.
    6. If using  external alarm eq uip ment, attac h the sup p lied  DW8 c ab le to the 
    120A and  the external eq uip ment. The maximum length of this c ab le 
    d ep end s on the alarm eq uip ment.
    7. If a TN474F is used , make sure the c irc uit p ac k is set for 24-c hannel 
    op eration. Set the switc h on the c irc uit p ac k as shown in Fig ure 2-1.
    8. From the DS1 circuit-pack screen of the system administration console, 
    set the line c omp ensation field  to 0-133 feet (40.6 m).
    9. Reset the 120A b y reseating  the DS1 c irc uit p ac k.
    When you reinsert the DS1 c irc uit p ac k after installing  a 120A CSU the 
    120A resets. The DS1 c irc uit p ac k initializes and  tests the 120A. When 
    initialization and  testing  is c omp lete, the g reen LED goes off. If the RED 
    indic ator is OFF after the test, the ICSU is working .
    10. If the c irc uits d o not p ass the self test, troub leshoot the 120A as instruc ted  
    in 
    Integ rated  CSU Mod ule Installation and  Op eration. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-145 Installing an Integrated Channel Service Unit (ICSU) Module 
    6
    Table 6-12 p rovid es the H600-383 c ab le p inouts. Table 6-13 p rovid es the c ab le 
    leng ths for eac h c ab le g roup  numb er.
    Table 6-12. H600-383 cable Pin Assignments
    Pin ColorChannel Service 
    Unit DesignationNetwork 
    Designation Function
    1BK Line in 0 R1 RCV
    2 Y Line in 1 T1
    3 Shield
    4 R Line out 0 R XMT
    5 G Line out 1 T
    7 Shield
    7 Not assigned
    8 Not assigned
    Table 6-13. H600-383 cable Lengths by Group Number
    Group Length Group Length
    1 25 feet (7.7 m) 5 125 feet (38.1 m)
    2 50 feet (15.2 m) 7 200 feet (71 m)
    3 75 feet (22.9 m) 7 400 feet (122 m)
    4 100 feet (30.5 m) 8 750 feet (198.1 m) 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-146 Installing a 3150/3170 Channel Service Unit 
    6
    Installing a 3150/3170 
    Channel Service Unit
    1. Install the CSU as shown in Figure 6-57. For some installations (suc h as a 
    DS1 c onverter), use a Y-c ab le to c onnec t the DEFINITY System to the 
    q uad  c ab le. Table 6-14
     shows the Y-c ab le lengths. Be sure to lab el all 
    cables. 
    Figure 6-57
     shows a typ ic al c onnec tion from the H600-348 Quad  c ab le to 
    the CSU, through the H600-307 network c ab le, and  to the network 
    interfac e throug h the smart jac ks. The q uad  c ab le p rovid es up  to four 
    c onnec tions using a 15-pin c onnec tor that p lug s into the DTE jac k on eac h 
    CSU. The H600-348 q uad  c ab le may req uire an ad ap ter c ab le.
    Figure 6-57. 3150/3170 Channel Service Unit Connections 
    1. H600-348 q uad  c ab le
    2. 15-p in male “ D”  c onnec tors (to DTE jac ks on CSU)
    3. Channel servic e unit (CSU)
    4. H600-307 c ab le (RJ-48C to RJ-48C)5. Network interfac e
    6. Smart jac k (if p rovid ed)
    7. Cable A
    8. Cable B9. Cab le C
    10. Cab le D
    3150csu RBP 062696
    POWERAUX PORT COM PORT MODEM
    DTENETWORK
    POWERAUX PO RT C OM PORT M OD EM
    DTENETWORK
    POWERAUX PORT COM PORT MODEM
    DTENETWORK
    POWERAUX PORT COM PORT MODEM
    DTENETWORK 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-147 Installing a 3150/3170 Channel Service Unit 
    6
    Figure 6-58. DS1 Converter Connections Using Double-Headed cable
    1. Port c arrier
    2. DS1 c onverter c onnec tor
    3. 50-p air female c onnec tor to DEFINITY System
    4. 14-Inc h (35.57 c m) “ Y”  c ab le5. 50-Pin Male/50-p in female d ouble-headed   
    c onnec tor c ab le
    6. Quad c ab le (with 50-pin male c onnec tor) c onnec ts 
    to the c hannel servic e unit.
    Table 6-14. “Y” cable Lengths (DS1 converter Only)
    Length 
    (in/cm) Description Comcode
    14/35.5  TN1754 to adjac ent exp ansion interfac e c irc uit p ac k or 
    TN573B switc h nod e interfac e c irc uit p ac k in same c arrier 847245750
    70/177.8 TN1754 to exp ansion interfac e c irc uit p ac k or switc h nod e 
    interfac e in another c arrier847245778
    14/35.5 TN1754 to fib er op tic  transc eiver (DC-p owered  c ab inets only). 
    This c ab le is for interc ab inet c ab ling only.847245777
    14/35.5 TN1754 to adjac ent TN570/B/C exp ansion interfac e c irc uit 
    pack 847747741
    cydf010 RPY 090597
    20 1916 17 18 15 14 13 12 1110
    09 08 07 06 05 04 03 02 01 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    Upgrades and Additions for R8r  555-233-115  Issue 1
    April 2000
    Adding or Removing Cabinet Hardware 
    6-148 Installing a 3150/3170 Channel Service Unit 
    6 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual