Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-139 Add MCC Port Carriers 6 Figure 6-55. TDM/LAN Bus Connections for Critical-Reliability EPN ICCB PORT CARRIER PORT CARRIER ICCA SLOT 02 ICCBICCACABLES A AND B H600-204 G1 B EXPANSIONCONTROL CARRIER SLOT 21 PORT CARRIER SLOT 21 REAR VIEW PORT CARRIER SLOT 21(ZAHF4) C SLOT 21 D E J58890BB J58890BB SEE NOTE SEE NOTE SEE NOTE SEE NOTE TDM/LAN BUS TERMINATOR NOTE:TDM/LAN CABLE WP91716 L6 TDM/LAN CABLE WP91716 L7 TDM/LAN CABLE WP91716 L6 TDM/LAN CABLE WP91716 L6INTERCARRIER J58890AF-1 A J58890BB TDM/LAN BUS TERMINATOR ZAHF4 J58890BB ON PORT CARRIER J58890BB-1, CONNECT TDM/LAN CABLE OR TDM/LAN TERMINATOR TO SLOT 02. ON PORT CARRIERS J58890BB-2 AND -3, CONNECT THE TDM/LAN CABLE OR TDM/LAN TERMINATOR TO SLOT 01.SLOT 21
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-140 Add MCC Port Carriers 6 Table 6-11. TDM/LAN Cable Connections “J” Number Carrier Type LHS Slot RHS Slot J58890B-1 Port 21 02 J58890B-2 Port 21 01 J58890B-3 Port 21 01 J58890AP PPN Control “A” or “B” 20 03 J58890AF AC EPN Control “ A” 21 02 J58890AF DC EPN Control “ A” 21 02
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-141 DEFINITY AUDIX Power Procedures 6 DEFINITY AUDIX Power Procedures Power Down the AUDIX System A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut d own the DEFINITY AUDIX System p rior to p owering d own the system. 1. Log into the AUDIX System as craft . 2. Type reset system shutdown . Press En te r onc e. NOTE: Do not p ress En t e r again. This will forc e the AUDIX to shutd own immed iately, d rop p ing all ac tive c alls on the AUDIX. 3. The “ SHUTDOWN Comp leted ” messag e ap p ears when the AUDIX is suc c essfully shutd own. This takes ab out 2 minutes. 4. The AUDIX System can now b e removed for service. Power Up the AUDIX System nIf the AUDIX was removed from the c ab inet: 1. Re-install the AUDIX and allow it to b oot up automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet b ut p ower was removed from the c ab inet: 1. Power up the c ab inet. The AUDIX reb oots automatic ally. 2. Check for AUDIX System errors. nIf the AUDIX remained in the c ab inet and the c ab inet was not powered down: 1. At the AUDIX c onsole, hold the crtl key and typ e cc . 2. Type 5 at the p romp t. In ab out 2 minutes, the AUDIX b oots up . 3. When the system initialization is c omp lete, log in as craft . 4. Check for AUDIX System errors.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-142 Installing an Integrated Channel Service Unit (ICSU) Module 6 Installing an Integrated Channel Service Unit (ICSU) Module The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU mod ule integ rated with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 loop b ac k jac k when testing the DS1 sp an. Checking for required components The integ rated c hannel servic e unit (ICSU) p ac kag e c ontains: n120A CSU mod ule nCab le H600-383 4-pair modular cord Group 2, 50-Foot (15.2 m) c able (standard ) nCord DW8A-DE 4-p air mod ular c ord to alarm c ontac ts nDS1 c irc uit p ac k The b asic ICSU req uires a TN474E or TN777D or later suffix. The enhanc ed integ rated c hannel servic e unit req uires a TN474F or TN777E or later suffix. Installing the 120A CSU See Figure 6-56.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-143 Installing an Integrated Channel Service Unit (ICSU) Module 6 Figure 6-56. 120A Channel Service Unit Module !CAUTION: Do not p lug the 120A into any c irc uit p ac k other than a TN474F or TN777E or later release/vintag e. Do not c onnec t the 120A to any interfac e other than a network smart jac k. Be sure the DS1 c irc uit p ac k is set for 24-c hannel op eration (1.544 Mb p s). The 120A d oes not op erate with the 32-c hannel interfac e. A switc h on the c irc uit p ac k or ad ministration sets this op tion. !CAUTION: Always wear an anti-static wrist strap when installing a 120A mod ule. Do not touc h the external alarm c able when it is c onnec ted to the 120A. Static d isc harg e c an d amag e c onnec tor terminals and relays. 1. Unp lug the DS1 c irc uit p ac k from its slot. 2. Install a 4C retainer in the 50-p in p lug assoc iated with the DS1 c irc uit p ac k slot. 3.Plug the 120A’s 25-p air c onnec tor d irec tly into the p lug assoc iated with the DS1 c irc uit p ac k slot. 1. Rear of c arrier c ontaining DS1 c irc uit p ac k 2. 120A CSU 3. 4-p air c ord to network interfac e (H600-383)4. DW8A-DE 4-p air c ord to alarm c ontac ts (op tional) 5. To 25-p air c onnec tor on rear of c arrier c ontaining DS1 c irc uit pac k 16 17 18 19 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01AU X icsupic RBP 032896
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-144 Installing an Integrated Channel Service Unit (ICSU) Module 6 4. Sec ure the 4C retainer around the 120A. 5. Attac h the sup p lied H600-383 c able to the 120A and to the network smart jac k. This c ab le is d irec tional. To determine the end that c onnec ts to the 120A, p erform a c ontinuity test b etween pins 3 and 7. The end with this c ontinuity is the 120A end . The shield is g round ed only at the 120A end . Use the c ab le p rovid ed . If c ab ling other than that p rovided with the 120A is used , ob serve the following g uid elines: nUse 24-g aug e wire that p rovid es ind ividually shield ed , twisted p airs for transmit and rec eive sig nals. Use the c ab le b etween the network interfac e and the 120A. Ground the shield s of this c able only at the 120A end to avoid g round loop s. nCab ling b etween the network interfac e and 120A c an have no bridge taps. nIf using stand ard house riser c ab le for c onnec tions b etween the network interfac e and the 120A, maintain a 100-p air sep aration b etween the rec eive and transmit twisted p airs. nIf using stand ard house riser c ab le for c onnec tions b etween the network interfac e and the 120A, allow no more than 2 c ross c onnec ts to 110-typ e c ross c onnec t bloc ks. nNever use quad c ab le (untwisted two pair telep hone c ab le) in a DS1 line. nAvoid mixing wires of d ifferent g aug es in a DS1 line. 6. If using external alarm eq uip ment, attac h the sup p lied DW8 c ab le to the 120A and the external eq uip ment. The maximum length of this c ab le d ep end s on the alarm eq uip ment. 7. If a TN474F is used , make sure the c irc uit p ac k is set for 24-c hannel op eration. Set the switc h on the c irc uit p ac k as shown in Fig ure 2-1. 8. From the DS1 circuit-pack screen of the system administration console, set the line c omp ensation field to 0-133 feet (40.6 m). 9. Reset the 120A b y reseating the DS1 c irc uit p ac k. When you reinsert the DS1 c irc uit p ac k after installing a 120A CSU the 120A resets. The DS1 c irc uit p ac k initializes and tests the 120A. When initialization and testing is c omp lete, the g reen LED goes off. If the RED indic ator is OFF after the test, the ICSU is working . 10. If the c irc uits d o not p ass the self test, troub leshoot the 120A as instruc ted in Integ rated CSU Mod ule Installation and Op eration.
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-145 Installing an Integrated Channel Service Unit (ICSU) Module 6 Table 6-12 p rovid es the H600-383 c ab le p inouts. Table 6-13 p rovid es the c ab le leng ths for eac h c ab le g roup numb er. Table 6-12. H600-383 cable Pin Assignments Pin ColorChannel Service Unit DesignationNetwork Designation Function 1BK Line in 0 R1 RCV 2 Y Line in 1 T1 3 Shield 4 R Line out 0 R XMT 5 G Line out 1 T 7 Shield 7 Not assigned 8 Not assigned Table 6-13. H600-383 cable Lengths by Group Number Group Length Group Length 1 25 feet (7.7 m) 5 125 feet (38.1 m) 2 50 feet (15.2 m) 7 200 feet (71 m) 3 75 feet (22.9 m) 7 400 feet (122 m) 4 100 feet (30.5 m) 8 750 feet (198.1 m)
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-146 Installing a 3150/3170 Channel Service Unit 6 Installing a 3150/3170 Channel Service Unit 1. Install the CSU as shown in Figure 6-57. For some installations (suc h as a DS1 c onverter), use a Y-c ab le to c onnec t the DEFINITY System to the q uad c ab le. Table 6-14 shows the Y-c ab le lengths. Be sure to lab el all cables. Figure 6-57 shows a typ ic al c onnec tion from the H600-348 Quad c ab le to the CSU, through the H600-307 network c ab le, and to the network interfac e throug h the smart jac ks. The q uad c ab le p rovid es up to four c onnec tions using a 15-pin c onnec tor that p lug s into the DTE jac k on eac h CSU. The H600-348 q uad c ab le may req uire an ad ap ter c ab le. Figure 6-57. 3150/3170 Channel Service Unit Connections 1. H600-348 q uad c ab le 2. 15-p in male “ D” c onnec tors (to DTE jac ks on CSU) 3. Channel servic e unit (CSU) 4. H600-307 c ab le (RJ-48C to RJ-48C)5. Network interfac e 6. Smart jac k (if p rovid ed) 7. Cable A 8. Cable B9. Cab le C 10. Cab le D 3150csu RBP 062696 POWERAUX PORT COM PORT MODEM DTENETWORK POWERAUX PO RT C OM PORT M OD EM DTENETWORK POWERAUX PORT COM PORT MODEM DTENETWORK POWERAUX PORT COM PORT MODEM DTENETWORK
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-147 Installing a 3150/3170 Channel Service Unit 6 Figure 6-58. DS1 Converter Connections Using Double-Headed cable 1. Port c arrier 2. DS1 c onverter c onnec tor 3. 50-p air female c onnec tor to DEFINITY System 4. 14-Inc h (35.57 c m) “ Y” c ab le5. 50-Pin Male/50-p in female d ouble-headed c onnec tor c ab le 6. Quad c ab le (with 50-pin male c onnec tor) c onnec ts to the c hannel servic e unit. Table 6-14. “Y” cable Lengths (DS1 converter Only) Length (in/cm) Description Comcode 14/35.5 TN1754 to adjac ent exp ansion interfac e c irc uit p ac k or TN573B switc h nod e interfac e c irc uit p ac k in same c arrier 847245750 70/177.8 TN1754 to exp ansion interfac e c irc uit p ac k or switc h nod e interfac e in another c arrier847245778 14/35.5 TN1754 to fib er op tic transc eiver (DC-p owered c ab inets only). This c ab le is for interc ab inet c ab ling only.847245777 14/35.5 TN1754 to adjac ent TN570/B/C exp ansion interfac e c irc uit pack 847747741 cydf010 RPY 090597 20 1916 17 18 15 14 13 12 1110 09 08 07 06 05 04 03 02 01
DEFINITY Enterprise Communications Server Release 8.2 Upgrades and Additions for R8r 555-233-115 Issue 1 April 2000 Adding or Removing Cabinet Hardware 6-148 Installing a 3150/3170 Channel Service Unit 6